• Title/Summary/Keyword: center loss

Search Result 3,766, Processing Time 0.028 seconds

Change of Germination Rate for Chili Pepper and Chinese Cabbage Seed in Relation to Packaging Materials and Storage Conditions over 10 Years (보관용기 및 저장조건에 따른 고추 및 배추종자의 10년간 발아율 추이)

  • Soh, Eun Hee;Lee, Woo Moon;Park, Kee Woong;Choi, Keun Jin;Yoon, Moo Kyoung
    • Horticultural Science & Technology
    • /
    • v.32 no.6
    • /
    • pp.864-871
    • /
    • 2014
  • Seed viability is affected by storage conditions and rapid loss of viability in storage is the major cause for low germination. This study was carried out to examine the effect of packaging materials and storage temperature on seed germination rate over 10 years in two species (Capsicum annuum L. and Brassica rapa L. ssp. pekinensis) and determine effective storage conditions for maintaining seed viability. Seeds were packaged in aluminum poly pouches under vacuum, polyethylene bottles, and paper bags containing silica gel and stored under one of two controlled conditions ($15^{\circ}C$, RH 40% or $5^{\circ}C$, RH 30%) or at ambient condition. Seed germination was recorded at 6-month intervals for 10 years. The seeds of both species showed no decline in viability until 6.5 years at 15 or $5^{\circ}C$, irrespective of packaging materials. However, under ambient conditions, the seeds of chili pepper and Chinese cabbage in paper bags lost viability after 4 and 5 years, respectively. By contrast, seeds of both species in vacuum-aluminum poly pouches exhibited a 99% germination rate after 6 years under ambient conditions. Pepper seeds in the vacuum-aluminum poly pouches maintained a 93% germination rate after 10 years in ambient conditions. These results indicated that a special seed storage facility for maintaining viability of chili pepper and Chinese cabbage seed might not be essential and seed testing would not be necessary for 10 years, if chili pepper and Chinese cabbage seeds were packed in ambient/vacuum-aluminum poly pouches or $5^{\circ}C$/vacuum-aluminum poly pouches.

Effects of Dietary Silkworm Droppings on Quality Characteristics of Pork Loin (잠분(蠶糞) 급여가 돈육의 품질 특성에 미치는 영향)

  • Lee Jeong-Ill;Lee Jung-Dong;Ha Young-Joo;Jung Jae-Doo;Lee Jin-Woo;Lee Jae-Ryung;Kwack Suk-chun;Kim Doo-Hwan;Do Chang-Hee
    • Food Science of Animal Resources
    • /
    • v.25 no.2
    • /
    • pp.175-188
    • /
    • 2005
  • This study investigated the effects of silkworm droppings (SWD) added diet feeding on quality characteristics of pork loin meat Pigs were divided into 7 treatment groups (10 pigs/group) and subjected to one of seven treatment diets $(0,\;1\%,\;2\%\;and\; 3\%\;SWD\;for\;4 weeks,\;1\%\;2\%\;3\%$ SWD for 8 weeks, SWD diets; total fed diets) before slaughter. Pork loin were collected from the animals (110kg body weight) slaughtered at a commercial slaughterhouse. Pork loin meat were packaged aerobically and then stored at $4^{\circ}C$ for 2, 5, 8, or 12 days. Samples were analyzed for general composition, texture characteristics and physico-chemical properties. pH value was not significantly different between the control and SWD treatment groups. pH of control and SWD treatment groups were increased as the storage period passed General composition, cooking loss and texture was not significantly different between the control and SWD treatment groups. WHC of SWD treatment group was higher than that of control group. WHC of control and SWD treatment groups were significantly decreased as the storage period passed (p<0.05). Meat and fat color (CIE $L^{\ast}$, $a^{\ast}$, $b^{\ast}$) were no significant differences between the control and SWD treatment groups. $L^{\ast}$ and $b^{\ast}$ value of meat color were decreased as the storage period passed There was a not significantly difference in shear force value among control and SWD treatment groups. Shear force value was decreased significantly during storage in all treatment groups. In all results, dietary SWD-supplementation was not affected in general components, texture characteristics and physico-chemical properties. It is suggested that dietary SWD-supplementation could produce of high quality pork.

Recent updated diagnostic methods for esophageal motility disorders (식도의 운동장애에 관한 최신지견)

  • Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.11-16
    • /
    • 2004
  • Classification of esophageal motility disorders not yet finalized and is still ongoing as the new disorders are reported, and the existing classification is changed or removed. In terms of radiology, the primary peristalsis does not exist, and the lower end of the esophagus show the smooth, tapered, beak-like appearance. The esophageal motility disorder, which mostly occurs in the smooth muscle area, show the symptoms of reduction or loss (hypomotility) or abnormal increase (hypermotility) of peristalsis of the esophagus. It is important to understand the anatomy and physiology of the esophagus for the appropriate radiological method and diagnosis. Furthermore, the symptom of the patient and the manometry finding must be closely referred for the radiological diagnosis. The lower esophageal sphincter can be normally functioning and open completely as the food moves lower. Sperandio M et al. argues that the name diffuse esophageal spasm must be changed to distal esophageal spasm (DES) as most of the spasm occurs in the distal esophagus, composed of the smooth muscle. According to Ott et al., usefulness of barium method for diagnosing the esophageal motility disorder is Achalasia 95%, DES 71% and NEMD 46%, with the overall sensitivity of 56%. However, excluding the nutcracker esophagus or nonspecific disorder which cannot be diagnosed with the radiological methods, the sensitivity increases to 89%. Using videofluoroscopy and 5 time swallows, the average sensitivity was over 90%. In conclusion, the barium method is a simple primary testing method for esophageal motility test. Using not only the image but also the videofluoroscopy with good knowledge of the anatomy and physiology, it is believed that the method will yield the accurate diagnosis.

  • PDF

Development of Heat Exchanger for Fermentation Heat Utilization from Waste Woody Biomass (목질계 폐바이오메스의 발효열이용 열교환기의 개발)

  • Cho, Nam-Seok;Choi, Tae-Ho;Kim, Hong-Eun;Lee, Suk-Ho;Lee, Chung-Koo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.94-104
    • /
    • 2009
  • It is urgently required to develop the production of fermentation-heat energy from the waste agricultural and forest biomass and its effective heat exchanging system for the supply of warm water to rural households and greenhouses. In this study 3 helical-type and 1 plate-type heat exchangers using 3 different waste biomasses [e.g. hardwood (HW) sawdust (100%), softwood (SW) sawdust : HW sawdust (50 : 50) and HW sawdust : grass (90 : 10)] were applied in order to find out the best heat recovery system. The heat exchanger was basically considered to improve the overall heat recovery efficiency, to minimize heat loss and to simplify manufacturing, assembling and breaking up the fermenting beds. The helical-type heat exchanger (HX-H3) installed in fermenting bed of HW sawdust : grass (90 : 10) showed relatively higher temperature profiles, in particular mid- and upper-parts than lower and surface parts during 45-day fermentation process. The maximum temperature was ranged from $40^{\circ}C$ to $65^{\circ}C$ with average $60^{\circ}C$. The water temperature of tank outlet was ranged to $33{\sim}48^{\circ}C$ during whole measuring periods. By the way plate-type one (HX-P) installed in same biomass compositional fermenting bed showed $64.5{\sim}76.5^{\circ}C$ at center part, and $43{\sim}56^{\circ}C$ and $42{\sim}58^{\circ}C$, water tank and tank outlet temperatures, respectively, during 100 day measurement. It could be concluded that the plate-type heat exchanger (HX-P) provides not only the effective heating for the rural households and greenhouses, but also having the best heat recovery performance, easy manufacturing, assembling and breaking up the systems.

Characteristics of a planar Bi-Sb multijunction thermal converter with Pt-heater (백금 히터가 내장된 평면형 Bi-Sb 다중접합 열전변환기의 특성)

  • Lee, H.C.;Kim, J.S.;Ham, S.H.;Lee, J.H.;Lee, J.H.;Park, S.I.;Kwon, S.W.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.154-162
    • /
    • 1998
  • A planar Bi-Sb multijunction thermal converter with high thermal sensitivity and small ac-dc transfer error has been fabricated by preparing the bifilar thin film Pt-heater and the hot junctions of thin film Bi-Sb thermopile on the $Si_{3}N_{4}/SiO_{2}/Si_{3}N_{4}$-diaphragm, which functions as a thermal isolation layer, and the cold junctions on the dielectric membrane supported with the Si-substrate, which acts as a heat sink, and its ac-dc transfer characteristics were investigated with the fast reversed dc method. The respective thermal sensitivities of the converter with single bifilar heater were about 10.1 mV/mW and 14.8 mV/mW in the air and vacuum, and those of the converter with dual bifilar heater were about 5.1 mV/mW and 7.6 mV/mW, and about 5.3 mV/mW and 7.8 mV/mW in the air and vacuum for the inputs of inside and outside heaters, indicating that the thermal sensitivities in the vacuum, where there is rarely thermal loss caused by gas, are higher than those in the air. The ac-dc voltage and current transfer difference ranges of the converter with single bifilar heater were about ${\pm}1.80\;ppm$ and ${\pm}0.58\;ppm$, and those of the converter with dual bifilar heater were about ${\pm}0.63\;ppm$ and ${\pm}0.25\;ppm$, and about ${\pm}0.53\;ppm$ and ${\pm}0.27\;ppm$, respectively, for the inputs of inside and outside heaters, in the frequency range below 10 kHz and in the air.

  • PDF

Death Recognition, Meaning in Life and Death Attitude of People Who Participated in the Death Education Program (죽음교육 프로그램 참여자의 죽음인식, 생의 의미 및 죽음에 대한 태도)

  • Kang, Kyung-Ah;Lee, Kyung-Soon;Park, Gang-Won;Kim, Yong-Ho;Jang, Mi-Ja;Lee, Eun
    • Journal of Hospice and Palliative Care
    • /
    • v.13 no.3
    • /
    • pp.169-180
    • /
    • 2010
  • Purpose: This study was to identify the death recognition, meaning in life, and death attitude of participants in the death education program. Methods: A survey was conducted, and 205 data were collected. Descriptive statistics, ${\chi}^2$-test, ANOVA, and Duncan test were used. Results: 1) The followings were the characteristics of death recognition shown by the participants. Over half of the participants said that they had given some thoughts on their deaths, that they had agreeable view on death acceptance, and that diseases and volunteer works made them think about their deaths. Moreover, suffering, parting with family and concerns for them, etc. were the most common reasons for the difficulty of accepting death. As for 'the person whom I discuss my death with', spouse, friend, and son/daughter were the most chosen in this order. Lastly, the funeral type that most of the participants desired was cremation. 2) The means of meaning in life and death attitude were $2.92{\pm}0.29$ and $2.47{\pm}0.25$, respectively. There were significant differences between health status, meaning in life and death attitude. 3) A significant positive corelationship was found between meaning in life and death attitude (r=0.190, P=0.001). Conclusion: For an effective death education program that would fit each individual's situation, an educational content that can make a person understand the meaning of his or her life and death, includes knowledge to lessen the fear and anxiety of death, and helps a person heal from the loss of a family member is absolutely necessary.

Community Dwellers' Perception of Past Life Recollection and Preparation for Death (서울시 일 지역 주민의 인생회고 및 죽음준비 인식)

  • Kang, Kyung-Ah;Lee, Kyung-Soon;Park, Gang-Won;Kim, Yong-Ho;Jang, Mi-Ja;Lee, Eun
    • Journal of Hospice and Palliative Care
    • /
    • v.14 no.2
    • /
    • pp.81-90
    • /
    • 2011
  • Purpose: This study is to understand how community members perceive past life recollection and preparation for death. Methods: Using a questionnaire, we surveyed 160 adult residents of one of the districts (gu) in Seoul, Korea. Descriptive statistics were used. Results: Participants chose their 30s and 40s as the most difficult time in their lives. The most painful experience was "an illness of a family member", followed by "trouble with a spouse", and "trouble with children". As for the most difficult social experience, "sense of loss in life" was ranked the highest. Personally, the happiest time was "accomplishment of a goal", while it was "happiness through children" in family relationship and "contribution to society through my career" in social life. As for the most regrettable experience, personally "having lived without purpose" was the highest, "not meeting my parents' expectation more" in family relationship; "not providing sufficient education" in relationship with children; "not having an occupation that I wanted" in work life, and "lack of social skills" in social life. More than 87% of the surveyed showed a positive attitude about the system of the do not resuscitate (DNS) order. For a situation where participants were supposed to have an incurable disease, "I want to be notified of the true condition" and "I want to write a will and advanced directives" ranked high, receiving more than 3.1 points out of 4. Conclusion: These results demonstrate the need for death education to provide people with an opportunity to accept their regrettable experiences in the past as part of their life. Also, this study suggests the importance of writing advanced directives for people to prepare for "death with dignity" how it can help their decision to be better respected.

Physicochemical and Sensory Properties of Pan Bread Made with Various Amounts of Squeezed Perilla Leaf Juice (깻잎착즙액을 이용하여 제조한 식빵의 이화학적 및 관능적 특성)

  • Oh, Suk-Tae;Kim, Kee-Hyuk;Kim, Won-Mo;Lee, Gyu-Hee
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.7
    • /
    • pp.833-840
    • /
    • 2017
  • For wide application of perilla leaf, which has various healthy functions and can be easily cultured across Korea, the physicochemical and sensory properties of pan bread made with various amounts of squeezed perilla leaf juice (SPLJ) were analyzed. When dough characteristics were analyzed by using farinograph, consistency and dough development time were not significantly different between the control and bread dough made with various amounts of SPLJ, whereas dough stability time increased with increasing SPLJ amount. Expansion rate of dough decreased with increasing SPLJ amount. The volume, specific volume, and baking loss rate of pan bread made with various SPLJ amounts decreased with increasing SPLJ amount. Pan bread crumb colors became thickened and greenish with increasing SPLJ amount. For physical properties of pan bread made with various SPLJ amounts, springiness and cohesiveness decreased with increasing SPLJ amount, whereas brittleness, chewiness, and hardness increased with increasing SPLJ amount. In the sensory strength analysis, pore uniformity and soft texture decreased with increasing SPLJ amount, whereas crumb color (dark greenish), perilla leaf odor, perilla leaf taste, and chewing texture increased with increasing SPLJ amount. In the overall acceptance analysis, 1.5% SPLJ was the most preferred with a score of 7.10. However, statistical differences between 1.5% and 1.0% SPLJ were not detected at P<0.05. In the partial least squares analysis, consumers liked bread with a green crumb color, perilla leaf odor, perilla leaf taste, and soft and chewing texture. In conclusion, physicochemical properties of pan bread made with SPLJ were less desirable than those of the control; however, consumer acceptance of pan bread made with 1.5% SPLJ was shown the highest. Therefore, methods for increasing physicochemical properties of pan bread made with SPLJ need to be developed for wide application of perilla leaf.

Identification of Tumor Suppressor Loci on the Short Arm of Chromosome 16 in Primary Small Cell Lung Cancers (원발성 소세포폐암에서 염색체 16번의 단완에 위치한 종양억제유전자좌의 확인)

  • Kee, Hyun Jung;Shin, Ju Hye;Chang, Joon;Chung, Kyung Young;Shin, Dong Hwan;Kim, Young Sam;Chang, Yoon Soo;Kim, Sung Kyu;Kwak, Seung Min;Kim, Se kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.6
    • /
    • pp.597-611
    • /
    • 2003
  • Background : Loss of the short arm of chromosome 16 is a frequent event in various cancers, which suggests the presence of tumor suppressor gene(s) there. To map precise tumor suppressor loci on the chromosome arm for further positional cloning efforts, we tested 23 primary small cell lung cancers. Method : The DNAs extracted from paraffin embedded tissue blocks with primary tumor and corresponding control tissue were investigated. Twenty polymorphic microsatellite markers located in the short arm of chromosome 16 were used in the microsatellite analysis. Results : We found that six (26.1%) of 23 tumors exhibited LOH in at least one of tested microsatellite markers. Two (8.7%) of 6 tumors exhibiting LOH lost a larger area in chromosome 16p. LOH was observed in five common deleted regions at 16p. Among those areas, LOH between D16S668 and D16S749 was most frequent (21.1%). LOH was also observed at four other regions, between D16S3024 and D16S748, D16S405, D16S420, and D16S753. Six of 23 tumors exhibited shifted bands in at least one of the tested microsatellite markers. Shifted bands occurred in 3.3% (15 of 460) of the loci tested. Conclusion : Our data demonstrated that at least five tumor suppressor loci might exist in the short arm of chromosome 16 and that they may play an important role in small cell lung cancer tumorigenesis.

A Study of Quality Control of Nuclear Medicine Counting System and Gamma Camera (핵의학 계측기기 및 감마카메라의 정도관리 연구)

  • 손혜경;김희중;정해조;정하규;이종두;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.103-112
    • /
    • 2001
  • Purpose: The purpose of this study was to investigate the current status of performing nuclear medicine quality control in korea and to test selected protocols of quality control of nuclear medicine counting system and gamma camera. Materials and Methods: Fifty three hospitals were included to investigate the current status of nuclear medicine quality control in korea. The precision of dose calibrator and thyroid uptake system was measured with Tc-99m 35.52 MBq for 2 minuets and Tc-99m 5.14 MBq for 10 sec every one minute, respectively. The sensitivity of CeraSPECT$^{TM}$ with low energy high resolution parallel hole collimator was measured using two cylindrical phantoms with 15 cm in diameter and 12 cm and 30 cm in heights containing Tc-99m. The correction factor for sensitivity of CeraSPECT$^{TM}$ was calculated using phantom data. The system planar sensitivity, uniformity, count rate and spatial resolution were measured for Varicam gamma camera with low energy high resolution parallel hole collimator using 140 keV centered 20% energy window, 256$\times$256 or 512$\times$512 matrix sizes. Results: The quality control of dose calibrator and well counter were showed poor performance status. On the other hand, The quality control of gamma camera and other systems were showed relatively good performance status. The results of precision of dose calibrator and thyroid uptake system was $\pm$1.4%(<$\pm$5%) and chi^2=29.7(>16.92), respectively. It showed that the sensitivity of CeraSPECT$^{TM}$ was higher in center slices compared with the edge slices. After correction of nonuniform sensitivities for patient data, it showed better results compare with prior to correction. System planar sensitivity of Varicam gamma camera was 4.39 CPM/MBq. The observed count rate at 20% loss was 102,407 counts/sec (head 1), 113,427 counts/sec (head 2), when input count rate was 81,926 counts/sec (head 1), 90,741 counts/sec (head 2). The spatial resolution without scatter medium were 8.16 mm of FWHM and 14.85 mm of FWTM. The spatial resolution with scatter medium were 8.87 mm of FWHM and 18.87 mm of FWTM. Conclusion: It is necessary to understand the importance of quality control and to perform quality control of nuclear medicine devices.vices.

  • PDF