• Title/Summary/Keyword: causes for failure

Search Result 1,097, Processing Time 0.028 seconds

Piping Failure Analysis In Domestic Nuclear Safety Piping System (국내 안전등급 배관에 대한 손상사례 분석)

  • Choi, Sun-Yeong;Choi, Young-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.617-621
    • /
    • 2003
  • The purpose of this paper is to analyze piping failure trend of safety pipings In domestic nuclear power plants. First, database for the piping failure was constructed with 105 data fields. The database includes plant population data, event data, and service history data. 7 kinds of piping failures in domestic NPPs were investigated. Among the 7 cases, detailed root causes were investigated for 3 cases. The first one is pipe wall thinning in main feedwater pipings of Westinghouse 3 loop type plants. The root cause of the wall thinning was flow accelerated corrosion near welding area. The next one is leak event in chemical and volume control system(CVCS) due to vibration. Some cracks occurred in socket welding area. The events showed that the integrity or socket weld is very vulnerable to vibration. The last one is also a leak event in primary sampling line in Korean standard reactor due to thermal fatigue. Although the structural integrity was not maintained by the events, there was no effect on nuclear safety in the above 3 piping failure eases.

  • PDF

Failure Analysis of Carburized Gears by Microstructural Observation (침탄처리된 기어의 미세 조직학적 손상 원인분석)

  • Chun, Hae Dong;Chang, Sung Ho;Kim, Kyung Wook;Kuk, Youn Ho
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.27 no.4
    • /
    • pp.191-201
    • /
    • 2014
  • The gear was made of SNC815 case-carburized, quench hardened and tempered steel. The gears were failed far earlier than the expected service life used in the industrial site. Causes of the failed gear were analyzed by microstructure observation. By the SEM and micro structure examinations, the damaged surfaces had been weared and failed by fatigue. Through microscope observation on the damaged surface, it was found that the cause of failure was determined by external overloading and the initial stage of the damage was closely related to complex contact fatigue failure. The overload and contact fatigue contributed to the early failure cause.

A Study on Railway Electric Traction Protection System (전철용 보호계전기 시스템에 관한 연구)

  • Lee, Hee-Yong;Kim, Wang-Gon;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1390-1395
    • /
    • 2004
  • Recently, the load increasement and new regenerative systems of electrified railway system make it a difficult to distinguish between the load current and fault current. The failure of traction system perhaps causes over-current to flow. The high current can collapse other railway systems. If failures of the traction system takes place, the failures are detected and protected lest it should provoke high current flow. The over current from such a traction system failure permit to charge high tension voltage and produces high temperature arc, voltage instability, current cutting, and break down railway systems. The traction system failures detect and the system has to immediately cut off from over-current flow. To isolate the failure, the system can distinguish failure current from current flows. It forces us to adapt such as a new intelligent protection system. The protective system in traction system play a role of detecting and isolating failure points. In this paper, we proposed intelligent algorithm for discriminating normal and abnormal situation instead of the system being operated abnormally.

  • PDF

Characteristic Analysis of Suspension Insulators for Distribution Line (배전용 현수애자의 특성분석)

  • 김찬영;김주용;송일근;이병성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.3
    • /
    • pp.259-264
    • /
    • 2000
  • The paper provides the characteristic analyses of porcelain suspension insulators. The comparisons of characteristics were made as a function of failed and unfailed insulators which had ben used in the fields. This paper also describes the failure modes occurred in the fields. The aging of cement corrosion of metal breaking of shed puncture in the head and separation of glaze are different failure modes for porcelain suspension insulators. Among these failure modes the puncture breaking and glaze problems were major concerns in this research. The cracks porosities of porcelain and micro-crystals on the graze were the causes of these failures. These results were confirmed by conducting various failure analyses.

  • PDF

Failure Forecasting Technology of Electronic Control System Using Automobile Input/Output Signal Detection (자동차의 입출력 신호 검출을 통한 전자제어 시스템의 고장예측기술)

  • Lee, J.S.;Son, I.M.
    • Journal of Power System Engineering
    • /
    • v.13 no.1
    • /
    • pp.59-64
    • /
    • 2009
  • Electronic control system of the engine is composed of various sensors and actuators, This paper is concerned with fault analysis for the stable operation of it. We suggest the technology that can systematically and reliably analyze fault causes of sensors and actuators by using the fault generating program. In results, we can acquire the systematic road map of occurring faults as well as the valuable information related to the operations of sensors and actuators. These results should be very useful to get the classification of fault causes, develop an electronic control system of engine, and review control strategies of it.

  • PDF

Analysis of Event in Domestic Bridge Failures (국내 교량구조물의 사고사례분석)

  • Kim, Young-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.2
    • /
    • pp.103-111
    • /
    • 2002
  • The objective of this study is to collect and classify bridge failures that occurred in domestic from 1974 through 2001 and to draw the engineering informations by analyzing the principal causes and the trends of the bridge failures. Total 45 failures of bridge were obtained and analyzed based on the factors such as time of failures, modes of failures, classification of materials of failed elements, types of failed elements, distribution of failure cases with respect to the highway grades. The critical problems of bridge failures are associated with the construction deficiencies, external causes, maintenance deficiencies, and design deficiencies. Since the study of failures in bridges would enhance the design and construction of safe bridges in the future, it would be needed to create data bases at the national level and to alter the related codes with identifying potential deficiencies from past failures data.

Alternative techniques for failure of conventional inferior alveolar nerve block

  • Lee, Choi Ryang;Yang, Hoon Joo
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.19 no.3
    • /
    • pp.125-134
    • /
    • 2019
  • Successful local anesthesia in dental treatment is the most important prerequisite for pain control of patients. However, unlike that in the maxilla, it is difficult to administer local anesthesia in the mandible, and the success rate of conventional inferior alveolar nerve block (IANB) is only 80-85%. It is attributed to various causes such as anatomical variations, extreme anxiety, and technical errors; thus, various alternatives have been devised to improve this. We will analyze the causes of failure in conventional IANB and examine various alternatives that can be applied in these cases.

Evolution of concrete encased - CFST column: A comprehensive review on structural behavior and performance characteristics

  • Namitha Raveendran;Vasugi K
    • Steel and Composite Structures
    • /
    • v.51 no.6
    • /
    • pp.619-645
    • /
    • 2024
  • In the construction industry, composite structures have revolutionized traditional design principles, opening innovative possibilities. The Concrete Encased - Concrete Filled Steel Tubular (CE-CFST) column stands out as a distinctive composite structure, offering structural stability and resilience for various engineering applications. Comprising Reinforced Concrete (RC) and Concrete Filled Steel Tubular (CFST) components, CE-CFST columns are valued for their inherent properties, including ductility and rigidity, CE-CFST is commonly used in the construction of bridges, high-rise buildings, and more. This article aims to provide a concise overview of the evolutionary development of CE-CFST columns and their performance in structural applications. Through a comprehensive review, the study delves into the behaviour of CE-CFST columns under different scenarios. It examines the influences of key parameters such as size, infills, cross section, failure causes, and design codes on the performance of CE-CFST columns, highlighting their enhanced functionality and future potential. Moreover, the review meticulously examines previous applications of CE-CFST columns, offering insights into their practical implementation.

FMEA Measures for Service Failure Management (서비스 실패 관리를 위한 FMEA 이용 방안)

  • Kim, Hyun Jung;An, Qin Rui;Kim, Soo Wook
    • Journal of Korean Society for Quality Management
    • /
    • v.42 no.1
    • /
    • pp.43-61
    • /
    • 2014
  • Purpose: This study identifies preventive measures for VOC management by analyzing the causes and effects of factors that contribute to high risk service failure using FMEA on KORAIL VOC data. Methods: Two research methods were used. First, a Risk Priority Number (RPN) was assigned to each KORAIL VOC based on Failure Mode and Effect Analysis (FMEA). Second, multiple regression analysis was run with RPN factors that include severity, occurrence, and detection as the independent variables and customer dissatisfaction as the dependent variable. Results: Multiple regression analysis showed that RPN factors including severity, occurrence, and detection had significantly positive relationship with customer dissatisfaction. Based on these results, an FMEA was performed on VOC categories with high RPN for railroad stations including platform, ticketing, ticket verification, parking, and escalator, and VOC categories with high RPN for trains including entrance doors, cafes, air quality, announcement, and ticket verification. Conclusion: This study has practical implications to service failure management. A priority order using FMEA was established for the list of customer dissatisfactions that should be addressed to actively manage service failure, and strategies for tackling this priority list are offered.

Automatic classify of failure patterns in semiconductor fabrication for yield improvement (수율 향상을 위한 반도체 공정에서의 불량 유형 자동 분류)

  • 한영신;최성윤;김상진;황미영;이칠기
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2003.11a
    • /
    • pp.147-151
    • /
    • 2003
  • Yield enhancement in semiconductor fabrication is important. Even though DRAM yield loss may be attributed to many problems, the existence of defects on the wafer is one of the main causes. When the defects on the wafer form patterns, it is usually an indication for the identification of equipment problems or process variations. In this paper describes the techniques to automatically classify a failure pattern using a fail bit map.

  • PDF