• Title/Summary/Keyword: carbon dioxide absorber

Search Result 27, Processing Time 0.023 seconds

Evaluations of the Acoustics Characteristics of Cellulose Absorbers (셀룰로오즈 흡음재의 음향적 특성 평가)

  • Yeon, Joon-Oh;Kim, Kyoung-Woo;Yang, Kwan-Seop
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.5
    • /
    • pp.456-462
    • /
    • 2013
  • Eco-friendly material applied to building would be one of the materials which is must developed for global environmental conservation and reduction of carbon dioxide. For development of eco-friendly material, a cellulose absorber has been developed with waste paper through adjustment of various mix proportions. The developed cellulose absorber has been tested for its acoustic properties such as absorption coefficient and dynamic stiffness. The absorption coefficient was evaluated by developing six samples and using impedance tube and reverberation chamber. As a result of the evaluation, 0.64(NRC) was secured in absorption coefficient and 4.7 $MN/m^3$ was indicated in dynamic stiffness. Also, for practical use of developed absorbers as inner heartwood in drywall, comparison test of sound reduction index was performed with existing glass wool absorbers and constructed drywall of gypsum board. The results have shown 55 dB(Rw) of sound reduction index in glass-wool wall and 46 dB(Rw) in cellulose.

A Study for Carbon dioxide Removal Process Using Methanol Solvent in DME Manufacture Process (DME 생산공정에서 메탄올을 이용한 이산화탄소 제거 공정 연구)

  • Cho, Duhee;Rho, Jaehyun;Kim, Dong Sun;Cho, Jungho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1502-1511
    • /
    • 2013
  • In this study, simulation works have been performed for the modeling of $CO_2$ removal process contained in the DME production process through an absorber-stripper system using methanol aqueous solution. Aspen Plus release 7.3 in AspenTech company was utilized as a simulation tool and PC-SAFT modeling equation of state was used as a thermodynamic model. Fitting parameters built-in PC-SAFT model was determined by regressing experimental data, predicted results using PC-SAFT model were compared with experimental data in order to verify the exactness of the thermodynamic model. Optimization works have been performed to reduce the utility consumptions using solvent circulation rate, column operating pressure and feed stage location as manipulated variables.

Critical review on Active Technologies to Regulate the Levels of Carbon Dioxide and Oxygen for Kimchi Packaging (김치포장 내부의 이산화탄소 및 산소 제어를 위한 포장 기술 고찰)

  • Jeong, Suyeon;Lee, Hyun-Gyu;Lee, Jung-Soo;Yoo, SeungRan
    • Journal of the Korean Society of Food Culture
    • /
    • v.34 no.2
    • /
    • pp.233-239
    • /
    • 2019
  • This paper presents a literature review on the active technologies to regulate the levels of carbon dioxide and oxygen in Kimchi packaging. In this study, laser-etched pouches and $O_2$ scavengers were used for Kimchi packaging, and the efficiency of each packaging technique to regulate the $CO_2$ and $O_2$ levels inside Kimchi packages was investigated. When Kimchi was packaged with a laser-etched pouch, the $CO_2$ concentration in the sample with a high gas transmission rate was less than that in other pouches (p<0.05), and a low $CO_2$ level had little effect on the expansion of the package volume. Kimchi treated with an $O_2$ absorber exhibited a significantly lower (p<0.05) $O_2$ concentration inside the packages relative to the control. A low $O_2$ concentration inside the Kimchi package effectively inhibited the growth of total aerobic bacteria and lactic acid bacteria, as well as yeasts and molds on Kimchi. These results suggest that $O_2$ absorbers have a positive effect on the microbial quality of Kimchi. Therefore, packaging in a laser-etched pouch and the use of an $O_2$ scavenger could provide a novel packaging material for regulating the $CO_2$ and $O_2$ levels during Kimchi packaging.

Post-combustion CO2 capture with potassium L-lysine (Potassium L-lysine을 이용한 연소 후 이산화탄소 포집)

  • Lim, Jin Ah;Yoon, Yeo Il;Nam, Sung Chan;Jeong, Soon Kwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4627-4634
    • /
    • 2013
  • Carbon dioxide is one of the main causes of global warming. In order to develop a novel absorbent, the characteristics of amino acid salts solution as a solvent for $CO_2$ capture in continuous process were investigated. The cost of $CO_2$ capture is almost 70% of total cost of CCS (carbon dioxide capture and storage). In the carbon dioxide capture process, process maintenance costs consist of the absorbent including the absorption, regeneration, degradation, and etc. It is very important to study the characteristics of absorbent in continuous process. In this study, we have investigated the properties of potassium L-lysine (PL) for getting scale-up factors in continuous process. To obtain optimum condition for removal efficiency of $CO_2$ in continuous process by varying liquid-gas (L/G) ratio, concentration of $CO_2$ and absorbent (PL) were tested. The stable condition of absorber and regenerator (L/G) ratio is 3.5. In addition, PL system reveals the highest removal efficiency of $CO_2$ with 3.5 of L/G and 10.5 vol% $CO_2$ ($1.5Nm^3/h$).

Performance Analysis of Upgrading Process with Amine-Based CO2 Capture Pilot Plant

  • Kwak, No-Sang;Lee, Junghyun;Lee, Dong Woog;Lee, Ji Hyun;Shim, Jae-Goo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.1
    • /
    • pp.33-38
    • /
    • 2018
  • This study applied upgrades to the processes of a 10 MW wet amine $CO_2$ capture pilot plant and conducted performance evaluation. The 10 MW $CO_2$ Capture Pilot Plant is a facility that applies 1/50 of the combustion flue gas produced from a 500 MW coal-fired power plant, and is capable of capturing up to 200 tons of $CO_2$. This study aimed to quantitatively measure efficiency improvements of post-combustion $CO_2$ capture facilities resulting from process upgrades to propose reliable data for the first time in Korea. The key components of the process upgrades involve absorber intercooling, lean/rich amine exchanger efficiency improvements, reboiler steam TVR (Thermal Vapor Recompression), and lean amine MVR (Mechanical Vapor Recompression). The components were sequentially applied to test the energy reduction effect of each component. In addition, the performance evaluation was conducted with the absorber $CO_2$ removal efficiency maintained at the performance evaluation standard value proposed by the IEA-GHG ($CO_2$ removal rate: 90%). The absorbent used in the study was the highly efficient KoSol-5 that was developed by KEPCO (Korea Electric Power Corporation). From the performance evaluation results, it was found that the steam consumption (regeneration energy) for the regeneration of the absorbent decreased by $0.38GJ/tonCO_2$ after applying the process upgrades: from $2.93GJ/ton\;CO_2$ to $2.55GJ/tonCO_2$. This study confirmed the excellent performance of the post-combustion wet $CO_2$ capture process developed by KEPCO Research Institute (KEPRI) within KEPCO, and the process upgrades validated in this study are expected to substantially reduce $CO_2$ capture costs when applied in demonstration $CO_2$ capture plants.

Degradation of Monoethanolamine during Continuous Operation of a Laboratory Scale CO2 Absorption System (실험실 규모 이산화탄소 흡수장치의 연속운전시 모노에탄올아민 열화 특성)

  • Kang, Ji-A;Woo, Wongu;Lim, Ho-Jin
    • Journal of Environmental Science International
    • /
    • v.25 no.3
    • /
    • pp.385-393
    • /
    • 2016
  • Oxidative and thermal degradation of alkanolamines for a promising $CO_2$ capture technology of absorption might cause decrease in $CO_2$ capture efficiency and formation of hazardous byproducts. In this study, characteristics of a representative absorbent of monoehtanolamine (MEA) were examined for a long term operation using a laboratory scale absorption system. An $CO_2$ absorption system with ID 56 mm and absorption zone height 100 cm was developed for the characterization. Absorption solution of 30 wt% MEA was circulated at 100 mL/min to treat air with 15% $CO_2$ and 1 ppm NO at 10 L/min. Temperatures of absorber and stripper were maintained at $40^{\circ}C$ and $120^{\circ}C$, respectively. For the course of 5 weeks continuous operation, MEA concentration was decreased approximately by 70% and $CO_2$ removal efficiency was dropped from 95% to 65%. Ionic byproducts of $NH_4{^+}$, $NO_2{^-}$, and $NO_3{^-}$ were accumulated up to 48 g/mL, 0.2 g/mL, and 1.5 g/mL, respectively, tracking the variation of MEA concentration. Formation of various organic byproducts were also observed.

Current Status of Tree Height Estimation from Airborne LiDAR Data

  • Hwang, Se-Ran;Lee, Im-Pyeong
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.3
    • /
    • pp.389-401
    • /
    • 2011
  • Most nations around the world have expressed significant concern in the climate change due to a rapid increase in green-house gases and thus reach an international agreement to control total amount of these gases for the mitigation of global warming. As the most important absorber of carbon dioxide, one of major green-house gases, forest resources should be more tightly managed with a means to measure their total amount, forest biomass, efficiently and accurately. Forest biomass has close relations with forest areas and tree height. Airborne LiDAR data helps extract biophysical properties on forest resources such as tree height more efficiently by providing detailed spatial information about the wide-range ground surface. Many researchers have thus developed various methods to estimate tree height using LiDAR data, which retain different performance and characteristics depending on forest environment and data characteristics. In this study, we attempted to investigate such various techniques to estimate tree height, elaborate their advantages and limitations, and suggest future research directions. We first examined the characteristics of LiDAR data applied to forest studies and then analyzed methods on filtering, a precedent procedure for tree height estimation. Regarding the methods for tree height estimation, we classified them into two categories: individual tree-based and regression-based method and described the representative methods under each category with a summary of their analysis results. Finally, we reviewed techniques regarding data fusion between LiDAR and other remote sensing data for future work.

A Study on Diesel Engine Performance with Ar and $CO_2$ Addition (Ar과 $CO_2$ 첨가에 따른 디젤기관의 성능에 관한 연구)

  • 정영식;이상만;채재우
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.4
    • /
    • pp.93-99
    • /
    • 1997
  • The re quest to develop the engines that are able to run without air or with very little oxygen condition is raised with the interest of ocean science or the mines. This research had already be gun before the world war II, but had been stagnant owing to the appearance of nuclear power. Recycle diesel engines have ability to run under the above mentioned condition the recycle diesel engine recirculates exhaust gases into intake port and consumes additional oxygen supplied by oxygen tank. Carbon dioxide is controlled by the absorber. The combustion and emission characteristics of recycle diesel engines are quite different with conventional one because the working fluids of recycle diesel engines consist of Ar, $CO_2$ and $O_2$ as well as $N_2$. Recycle diesel engine is therefore different with general diesel engine from the viewpoint of intake air composition. It is required to investigate the effect of intake composition in the combustion and emission to know recycle diesel engine. In this study, NOx concentration, smoke and cylinder pressure are measured with the variation of Ar and $CO_2$ Reduces show that the addition of Ar reduces NOx but increases smoke. Otherwise $CO_2$ reduces smoke and NOX simultaneously. Only $CO_2$ increases the ignition delay and both gases increase fuel consumption Ar addition is superior to $CO_2$ addition for the performance of recycle diesel engine system but $CO_2$ has the avantage with respect to emission.

  • PDF

A Study on the Thermodynamic Analysis and the Computer Simulation for the $CO_2$ and $H_{2}S$ Capture Process Using Methanol as a Solvent (메탄올 용매를 이용한 이산화탄소와 황화수소 포집공정의 열역학적 해석 및 전산모사에 관한 연구)

  • Cho, Jung-Ho;Lee, Ji-Hwan
    • Clean Technology
    • /
    • v.14 no.4
    • /
    • pp.287-292
    • /
    • 2008
  • In this study, computer simulation works have been performed for the capture process of the $CO_2$ and $H_{2}S$ gases contained in the effluent stream using methanol aqueous solution. In order to increase the solubilities of the $CO_2$ and $H_{2}S$ in the methanol aqueous stream, the operating pressure of the absorber was raised to 30 bar and the feeding temperature of the solvent was lowered to $-20^{\circ}C$ by using refrigeration cycle. NRTL liquid activity coefficient model was used to estimate the liquid phase nonidealities for methanol and water. Soave-Redlich-Kwong equation of state was used for the vapor phase nonidealities. Henry's law option was also used to calculate the solubilities of the supercritical noncondensible gases into the methanol aqueous solvent stream.

  • PDF

Adiabatic Performance of Layered Insulating Materials for Bulk LH2 Storage Tanks (대용량 액체 수소 저장탱크를 위한 다층단열재의 단열성능 분석)

  • KIM, KYEONGHO;SHIN, DONGHWAN;KIM, YONGCHAN;KARNG, SARNG WOO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.6
    • /
    • pp.642-650
    • /
    • 2016
  • One of the most feasible solution for reducing the excessive energy consumption and carbon dioxide emission is usage of more efficient fuel such as hydrogen. As is well known, there are three viable technologies for storing hydrogen fuel: compressed gas, metal hydride absorption, and cryogenic liquid. In these technologies, the storage for liquid hydrogen has better energy density by weight than other storage methods. However, the cryogenic liquid storage has a significant disadvantage of boiling losses. That is, high performance of thermal insulation systems must be studied for reducing the boiling losses. This paper presents an experimental study on the effective thermal conductivities of the composite layered insulation with aerogel blankets($Cryogel^{(R)}$ Z and $Pyrogel^{(R)}$ XT-E) and Multi-layer insulation(MLI). The aerogel blankets are known as high porous materials and the good insulators within a soft vacuum range($10^{-3}{\sim}1$ Torr). Also, MLI is known as the best insulator within a high vacuum range(<$10^{-6}{\sim}10^{-3}$ Torr). A vertical axial cryogenic experimental apparatus was designed to investigate the thermal performance of the composite layered insulators under cryogenic conditions as well as consist of a cold mass tank, a heat absorber, annular vacuum space, and an insulators space. The composite insulators were laminated in the insulator space that height was 50 mm. In this study, the effective thermal conductivities of the materials were evaluated by measuring boil-off rate of liquid nitrogen and liquid argon in the cold mass tank.