• 제목/요약/키워드: capacitance measurement method

Search Result 138, Processing Time 0.03 seconds

Properties of $TiO_2-V_2O_5$ Ceramics Prepared by Sol-Gel Method (솔젤법으로 제작한 $TiO_2-V_2O_5$ 세라믹스의 물성)

  • You, Do-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1255-1260
    • /
    • 2007
  • [ $TiO_2-V_2O_5$ ] sol was prepared using sol-gel method. Sol changed to gel with hydrolysis and polymerization. DTA properties of gel powder had endothermic reaction due to evaporation of propanol about $80^{\circ}C$, had exothermic reaction due to combustion of propanol about $230^{\circ}C$ and had exothermic reaction due to combustion of alkyl group about $350^{\circ}C$. Crystalline properties of gel powder retained amorphous phase at $50^{\circ}C$, retained anatase phase from $400^{\circ}C\;to\;600^{\circ}C$ and had all rutile phase over $700^{\circ}C$ at 0.01mole $V_2O_5$ additive. The capacitance of thin films increased with increasing heat treatment temperature and thin films had best properties at $700^{\circ}C$. The capacitance of thin films increased a lot with decreasing measurement frequency.

The Analysis of DC and AC Current Crowding Effects Model in Bipolar Junction Transistors Using a New Extraction Method (새로운 측정방법을 이용한 바이폴라 트랜지스터에서의 직류 및 교류 전류 편중 효과에 관한 해석)

  • 이흥수;이성현;김봉렬
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.8
    • /
    • pp.46-52
    • /
    • 1994
  • DC and AC current crowding effects for microwave and high speed bipolar transistors are investigated in detail using a new and accurate measurement technique based on Z-parameter equationa. Using the new measurement technique dc and ac current crowding effects have been explained clearly in bipolar junction transistors. To model ac crowding effects a capacitive element defined as base capacitance (C$_b$), called ac crowding capacitance is added to base resistance in parallel thereby treating the base resistance(R$_b$) as base impedance Z$_b$. It is shown that base resistance decreases with increasing collector current due to dc current crowding and approaches to a certain limited value at high collector current due to current crowding and approaches to a certain limited value at high collector currents regardless of the emitter size. It is also observed that due to ac current crowding base capacitance increases with increasing collector current. To quantigy the ac crowding effects for SPICE circuit simulation the base capacitance(C$_b$) including the base depletion and diffusion components has been modeled with an analytical expression form.

  • PDF

Measurement of Geometric Errors in a Miniaturized Machine Tool Using Capacitance Sensors (정전용량센서를 이용한 소형공작기계의 기하학적 오차측정)

  • Kweon S.H.;Lee J.H.;Liu Y.;Lim C.B.;Yang S.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1733-1736
    • /
    • 2005
  • Many studies have been carried out to produce 3D features in the size range between $10{\mu}m\~10,000{\mu}m$, called Meso-scale. If these miniaturized systems have high relative accuracy and good volumetric utilization, it is possible to manufacture more complex and accurate shapes with various materials as well as there are advantages of reducing energy, space and resources. Due to imperfect components and misalignment in assembly, it is necessary to assess the accuracy of the miniaturized system itself to obtain high relative accuracy. Laser interferometers are widely used to measure geometric errors called as quasi-static errors. For miniaturized system, however, it is difficult to install the required accessories such as optics and the measuring range is limited because of the size of the system and also this method is very expensive. Moreover, it is impossible to measure each error component simultaneously. A new system to measure simultaneously multiple geometric errors is proposed using capacitance sensors. Each error was measured using capacitance sensors and a measurement algorithm was mathematically derived. The experiments show that the proposed measurement system can be used effectively to assess the accuracy of miniaturized system at a low cost.

  • PDF

An Improved Technique for Fault Location Estimation Considering Shunt Capacitance on Transmission Line

  • Kim Hyun-Houng;Jeong Yun-Won;Lee Chan-Joo;Park Jong-Bae;Shin Joong-Rin
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.295-301
    • /
    • 2006
  • This paper presents a new two-terminal numerical algorithm for fault location estimation using the synchronized phasor in time-domain. The proposed algorithm is also based on the synchronized voltage and current phasor measured from the PMUs (Phasor Measurement Units) installed at both ends of the transmission lines. In this paper, the algorithm is given without shunt capacitance and with shunt capacitance using II -model and estimated using DFT (Discrete Fourier Transform) and LES (Least Error Squares Method). The algorithm uses a very short data window and classification for real-time transmission line protection. To verify the validity of the proposed algorithm, the Electro-Magnetic Transient Program (EMTP) and MATLAB are used.

Effect of Capacitance Error on the A/D conversion Accuracy (커패시턴스 오차가 아날로그 디지털 변환의 정확도에 미치는 영향)

  • Lee, Yun-Tae;Kim, Chung-Gi;Gyeong, Jong-Min
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.5
    • /
    • pp.57-61
    • /
    • 1985
  • The e(lect of capacitance error on the A/D conversion accuracy in the A/D converter using binary-weighted capacitor array was scruntized. Besides the Monte-Carlo method considering the inter-capacitance ratios as random variables, " correlation approach" con-sidering the correlation coefficient between capacitances is proposed in this paper. Bt was observed by the measurement of capacitances of monolithic MO5 capacitors that the correla-tion coefficient between capacitors decreases as the capacitor size incrrases. It was also verified that the parallel connection of unit capacitors and the common centroid layout scheme signi(icantly increase the inter-capacitance correlation coefficients.

  • PDF

A New Small Signal Modeling of RE MOSFETs including Charge Conservation Capacitances

  • Ickjin Kwon;Minkyu Je;Lee, Kwyro;Hyungcheol Shin
    • Proceedings of the IEEK Conference
    • /
    • 2000.07b
    • /
    • pp.957-960
    • /
    • 2000
  • A novel extraction method of high frequency small-signal model parameters for MOSFETS is proposed. From S-parameter measurement, this technique accurately extracts the model parameters including the charge conservation capacitance parameters. To consider charge conservation, nonreciprocal capacitance is considered. The modeled parameters fit the measurements very well without any optimization.

  • PDF

Development of a Real-Time Soil Moisture Meter using Oscillation Frequency Shift Method

  • Kim, Ki-Bok;Lee, Nam-Ho;Lee, Jong-Whan;Lee, Seoung-Seok;Noh, Sang-Ha
    • Agricultural and Biosystems Engineering
    • /
    • v.2 no.2
    • /
    • pp.63-68
    • /
    • 2001
  • The objective of this study was to develop a real-time soil moisture meter using RF impedance. The impedance suchas capacitance and resistance (or conductance) was analyzed using parallel cylinder type capacitance probe(C-probe) and Q-meter (HP4342). The capacitance and conductance of soil increased as volumetric water content increased. The 5 MHz of modified Colpitts type crystal oscillator was designed to detect the capacitance change of the C-probe with moist soil. A third order polynomial regression model was proposed to describe the relationship between RF impedance and volumetric water content. The prototype real time moisture meter consisted of the C-probe, sample container, oscillator, frequency counter and related signal processing units. The calibration equation for measurement of volumetric moisture content of soil was developed and validated. The correlation coefficient and root mean square error between measured volumetric water content by oven method and predicted values by prototype moisture meter for unknown soil samples were 0.984 and 0.032$cm^3$$cm\^3$, respectively.

  • PDF

Implementation of apparatus for detecting Ringer's solution exhaustion using electrostatic capacitance variation (정전용량변화를 이용한 링거액소진감지장치의 구현)

  • Kim, Cheong-Worl
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Electrostatic capacitance measurement method in a fine hose was proposed, in which two ring-type electrodes were disposed on the hose in the direction of fluid flow instead of the conventional face-to-face electrodes. With the proposed electrode structure, we realized a Ringer's solution exhaustion detector for an IV(invasive vein) injection set. On a 4 mm-diameter hose of IV set, we disposed two ring-type electrodes of 10 mm width at a distance of 5 mm each other and obtained 0.72 pF and 2.51 pF for air and 10 % dextrose Ringer's solution in the hose, respectively. The capacitance between the two electrodes varied with the hose-wraparound coverage of electrode as well as the width of electrode and the distance between the electrodes. For hose-wraparound electrode coverage of 75 %, the capacitance varied from 0.62 pF to 1.98 pF with the Ringer's solution level between the two electrodes. A charge amplifier converted the capacitance. variation into electric signal and a comparator was used to detect whether Ringer's solution was exhausted or not. The result was delivered to a host using a RF transmitter with 320 MHz carrier frequency.