• Title/Summary/Keyword: building fire safety

Search Result 637, Processing Time 0.032 seconds

An Experimental Study on the Estimation for the Flow Coefficient of Elevator Hoistway (엘리베이터 승강로의 유량계수 산정에 관한 실험 연구)

  • Kim, Hak-Joong
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.43-48
    • /
    • 2012
  • Recently, evacuation safety of building resident become the major concern, as the building has been higher and more complicated. Required evacuation time using stairway is longer in high-rise buildings, moreover it is impossible for the disabled to evacuate by using stairway. For this reason the study on the effectiveness of using elevator for evacuation is progressing. This study shows the flow coefficient of hoistway when elevator is moving. The results of this study can be used for the study of elevator piston effect as basic data. Experiments were performed in 5 different hoistways at 3-story and 2-story buildings. According to the result of flow coefficient experiments, average flow coefficient is 0.954. Considering the $4{\sigma}$ to guarantee 99.99 % reliance, it is 0.86. This result is 3.6 % bigger than 0.83 that Klote and Tamura suggested. It represents that the maximum critical pressure is decreased about 7 % on the same condition of elevator and elevator shaft. When the smoke control performance of high-rise building is evaluated, the result is significant economically by applying a more realistic and less value of elevator piston effect.

The Study on the Effect of Elevator Movement on the Pressure Difference between Vestibule and Living room in High-rise Buildings (초고층 건축물에서 엘리베이터 구동이 부속실과 화재실 간 차압형성에 미치는 영향연구)

  • Park, Younggi;Hong, Kibea;Ryou, Hong Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.85-91
    • /
    • 2018
  • Recently, there have been a lot of casualties due to fires in high-rise buildings. The toxic gases and smokes generated by fires in high-rise buildings spread rapidly through the elevator shaft and stairwell, due to the stack effect, and can cause critical casualties. To reduce the number of casualties, smoke control systems have been introduced. Smoke control systems play an essential role in preventing the spread of smoke in high-rise buildings and securing the evacuation route. Also, in high-rise buildings, evacuation by an elevator is considered to be indispensable. However, the pressure field in the shaft is strongly disturbed when the elevator is moving and this can affect the performance of the smoke control system. Therefore, in this study, we experimentally and numerically analyzed the effect of elevator movement on the pressure difference between the vestibule and living room by building a model using the sandwich pressurization method based on the performance based design. To consider the leakage areas in high-rise buildings, e.g. the windows, fire door and elevator, the National Fire Safety Codes and area ratio were used. The elevator speed in the model building was varied between 20 m/s and 100 m/s corresponding to a real elevator speed of 7 m/s~17 m/s. As a result, the relationship between the pressure difference and elevator speed was found to be ${\Delta}P=40{\cdot}{\exp}$(-Ves /-104.7)-23.735. This result can be used to take into consideration the effect of elevator movement when designing smoke control systems.

A Study on the Effects of an Increase in the Height of Ship's Accommodation Area on Safe Evacuation in Emergency Situation (선박 거주구역의 높이가 피난안전에 미치는 영향에 대한 연구)

  • Kim, Won-Ouk;Kim, Jong-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.1
    • /
    • pp.69-73
    • /
    • 2011
  • Unlike land fires, Fires on board a ship are not likely to be extinguished by skilled human resources using a variety of fire fighting equipments, but have to be brought under control on board a ship itself despite of difficult task. There are more cases of deaths from suffocation by smoke than from an increased temperature by heat in fires on board ships, because crew fail to secure a sufficient visibility range enough to escape from the scene of a fire or to leave the ship as early as possible. On the assumption that the height of ship's accommodation area increases from 2.0m to 2.3m comparable to the height of apartments on the ground in Korea, behaviors of fire smokes between the cases of 2.0m and 2.3m heights were compared and analyzed. Based on the blue print of the existing Training Ship "Hanbada", a new blueprint with the 30 cm height adjustment was additionally created. FDS (Fire Dynamic Simulator), which was created by the NIST in the United States and is the most widely distributed simulator for fires, was used to conduct a simulation and predict results. The results of simulation on the basis of temperature of $60^{\circ}C$ showed a safe evacuation period of time at the position 10m apart from the scene of a fire to increase by 55.8 seconds, when the height of ship's accommodation area increased from 2.0m to 2.3m. The results of simulation on the basis of visibility range of 6m showed the safe evacuation periods of time at the positions 10m, 20m and 30m apart from the scene of a fire to increase by 27.1 seconds, 109.2 seconds and 73.3 seconds, respectively, as the height of ship's accommodation area increased from 2.0m to 2.3m. This means that crew can escape more safely from a scene of fires on board when the height of ship's accommodation area is increased and equal to the height of living room in a building on land.

A Study on the Character and Walking Velocity of Crowd Going up Stairs (계단에서 올라가는 군집보행의 속도에 관한 조사 및 특성에 관한 연구)

  • Park, Jae-Sung
    • Fire Science and Engineering
    • /
    • v.25 no.1
    • /
    • pp.72-77
    • /
    • 2011
  • The effort of transferring some parts of urban functions to the underground space is growing trend among modem cities because of the limit of horizontal land use, the rise of land value, the diversification of human desire, etc. Thus, the basement of building and the subway station have deepened. It calls our attention to safety about evacuation from the underground space to the ground. Until now, the study about crowding walk in stairs has been progressed, focusing on the crowding walk that is going down the stairs, and there is no study about crowding walk that is going up the stairs. This study measured walking pace by crowd density that is going up the stairs in the subway station stairs making one-way movement of crowd. The actual survey showed that the mathematical relation 'V=0.638-0.0949p' determines going up walking velocity at a gradient of $23^{\circ}$, and the mathematical relation will be 'V=0.597-0.1067p' at a gradient of $30^{\circ}$, when it is converted, based on the average walking velocity of crowd by the slope of the stairs which is recommended by Architectural Institute of Japan.

A Study on the Development of the Response Resource Model of Hazardous and Noxious Substances Based on the Risks of Marine Accidents in Korea (위험도에 기반한 HNS 방제자원 모델 개발에 관한 연구)

  • Lee, Eun-Bang;Yun, Jong-Hwui;Chung, Sang-Tae
    • Journal of Navigation and Port Research
    • /
    • v.36 no.10
    • /
    • pp.857-864
    • /
    • 2012
  • Reviewing the statistics of harbor shipment of hazardous and noxious substance and the past spill accidents of HNS enabled us to assess the potential risks of transportation of HNS through the major harbors in Korea. Ulsan, Yeosu, Daesan port are relatively evaluated high risk in fire, health and environment disaster. Through the analysis of domestic preparedness to HNS accidents, the supplement of expertise resource to respond the vulnerability of the explosion, the fire and the physiological hazard, is required. Based on this risk assessment and review of the advanced case of Japan in building up HNS response system, a resource model at a national level was proposed which differentiates the sea areas for the proper allocation of resources to respond effectively to HNS accidents in the future.

Disaster Management and Disaster Medical Improvement in Underground Space (서울시 지하공간 재난관리 및 재난의료 개선방안)

  • Bae, Yoonshin;Park, Jihye
    • Journal of the Society of Disaster Information
    • /
    • v.7 no.2
    • /
    • pp.110-122
    • /
    • 2011
  • In this study, the disaster management and disaster medical improvement was described in underground space(specifically underground shopping center) in case of fire disaster occurred. Firstly, statue and system was discussed concerning building law, safety, fire services, refuge. The underground in Seoul management is classified as to space and form and management agent is different according to the type form. Because the difficulty of emergency rescue arises due to individual management system unified system needs to be established and improvement of facility management agent is necessary. For the patient to be transfer on the ground, corporation between command head quarter and emergency rescue team are essential. And disaster information and emergency medical information are also need to be considered. Therefore, effective countermeasures for emergency saving is urgent considering distribution of medical institution and medical treatment.

A Study on the Consciousness Survey for the Establishment of Safety Village in Disaster (재난안전마을 구축을 위한 의식조사 연구)

  • Koo, Wonhoi;Baek, Minho
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.3
    • /
    • pp.238-246
    • /
    • 2018
  • Purpose: The purpose of this study is to examine the directions for establishing a disaster safety village in rural areas where damage from a similar type of disaster occurs repeatedly by conducting the consciousness survey targeting at experts and disaster safety officials in a local government. Method: The risks of disaster in rural areas were examined and the concept and characteristics of disaster safety village which is a measure on the basis of Myeon (township) among the measures of village unit were examined in order to carry out this study. In addition, opinion polling targeting at officials-in-charge in the local government and survey targeting at experts in disaster safety and building village were conducted. Based on the findings, the directions for establishing a disaster safety village that fitted the characteristics of rural areas were examined. Result: The officials-in-charge in the local government answered that rural areas have a high risk of storm and flood such as heavy snowing, typhoon, drought, and heavy rain as well as forest fire, and it is difficult to draw voluntary participation of farmers for disaster management activities due to their main duties. They also replied that active support and participation of residents in rural areas are necessary for future improvement measures. The experts mostly replied that the problem of disaster safety village project is a temporary project which has low sustainability, and the lack of connections between the central government, local governments and residents was stressed out as the difficulties. They said that measures to secure the budget and the directions of project promotion system should be promoted by the central government, local governments and residents together. Conclusion: The results of this study are as follows. First, a disaster safety village should be established in consideration of the disaster types and characteristics. Second, measures to secure the budget for utilizing the central government fund as well as local government fund and village development fund should be prepared when establishing and operating a disaster safety village in rural areas. Third, measures to utilize a disaster safety village in rural areas for a long period of time such as the re-authorization system should be prepared in order to continuously operate and manage such villages after its establishment. Fourth, detailed measures that allow residents of rural areas to positively participate in the activities for establishing a disaster safety village in rural areas should be prepared.

Causal Relationship between the Risk-inducing Factors and Safety Inspection and Accident Reduction in Small Construction Sites (소규모 건설현장에서 위험유발요인과 안전점검이 재해 저감 대책에 미치는 인과 관계)

  • Moon, Pil-jae;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.2
    • /
    • pp.55-70
    • /
    • 2020
  • This study aims to identify the influence of risk-inducing factors and safety inspection on the measures of reducing accidents among workers of building structures in small construction sites. The result can be summarized as follows: First, as for the influence of risk-inducing factors on human factors, preparation for work, disintegrating molds, taking follow-up measures, and keeping records, have statistically significant influences. Therefore, it can be said that safety inspection has a partial mediating effect in the relationship between risk-inducing factors and human factors. Second, as for the influence of risk-inducing factors on facility factors, preparation for work, and taking follow-up measures influenced significantly. This indicates that safety inspection has a partial mediating effect in the relationship between risk-inducing factors and facility factors. Third, as for the influence of risk-inducing factors on management factors, the installation of shores and risk assessment are found to have significant effects. This shows that safety inspection has a partial mediating effect in the relationship between risk-inducing factors and management factors. Fourth, the influence of risk-inducing factors on work factors was significant only in the installation of shores. This indicates that safety inspection has a completely mediating effect in the relationship between risk-inducing factors and work factors. Finally, in the relationship between risk-inducing factors and accident reduction measures, preparation for work, installation of shores, and taking follow-up measures showed significantly positive influences. In contrast, keeping records has a significant negative influence. Thus, safety inspection has a partial mediating effect in the relationship between risk-inducing factors and management factors.

Installation Standards of Urban Deep Road Tunnel Fire Safety Facilities (도심부 대심도 터널의 방재시설 설치 기준에 관한 연구(부산 승학터널 사례를 중심으로))

  • Lee, Soobeom;Kim, JeongHyun;Kim, Jungsik;Kim, Dohoon;Lim, Joonbum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.727-736
    • /
    • 2021
  • Road tunnel lengths are increasing. Some 1,300 tunnels with 1,102 km in length had been increased till 2019 from 2010. There are 64 tunnels over 3,000 m in length, with their total length adding up to 276.7 km. Safety facilities in the event of a tunnel fire are critical so as to prevent large-scale casualties. Standards for installing disaster prevention facilities are being proposed based on the guidelines of the Ministry of Land, Infrastructure and Transport, but they may be limited to deep underground tunnels. This study was undertaken to provide guidelines for the spacing of evacuation connection passages and the widths of evacuation connection doors. Evacuation with various spacing and widths was simulated in regards to evacuation time, which is the measure of safety, using the evacuation analysis simulation software EXODUS Ver.6.3 and the fire/smoke analysis software SMARTFIRE Ver.4.1. Evacuation connection gates with widths of 0.9 m and 1.2 m, and spacings of 150 m to 250 m, were set to every 20 m. In addition, longitudinal slopes of 6 % and 0 % were considered. It was determined to be safe when the evacuation completion time was shorter than the delay diffusion time. According to the simulation results, all occupants could complete evacuation before smoke spread regardless of the width of the evacuation connection door when the longitudinal slope was 6 % and the interval of evacuation connection passage was 150 m. When the evacuation connection passage spacing was 200 m and the evacuation connection gate width was 1.2 m, all occupants could evacuate when the longitudinal slope was 0 %. Due to difference in evacuation speed according to the longitudinal slope, the evacuation time with a 6 % slope was 114 seconds shorter (with the 190 m connection passage) than with a 0 % slope. A shorter spacing of evacuation connection passages may reduce the evacuation time, but this is difficult to implement in practice because of economic and structural limitations. If the width of the evacuation junction is 1.2 m, occupants could evacuate faster than with a 0.9 m width. When the width of a connection door is 1.2 m with appropriate connection passage spacing, it might provide a means to increase economic efficiency and resolve structural limitations while securing evacuation safety.

Measuring Visual Attention Processing of Virtual Environment Using Eye-Fixation Information

  • Kim, Jong Ha;Kim, Ju Yeon
    • Architectural research
    • /
    • v.22 no.4
    • /
    • pp.155-162
    • /
    • 2020
  • Numerous scholars have explored the modeling, control, and optimization of energy systems in buildings, offering new insights about technology and environments that can advance industry innovation. Eye trackers deliver objective eye-gaze data about visual and attentional processes. Due to its flexibility, accuracy, and efficiency in research, eye tracking has a control scheme that makes measuring rapid eye movement in three-dimensional space possible (e.g., virtual reality, augmented reality). Because eye movement is an effective modality for digital interaction with a virtual environment, tracking how users scan a visual field and fix on various digital objects can help designers optimize building environments and materials. Although several scholars have conducted Virtual Reality studies in three-dimensional space, scholars have not agreed on a consistent way to analyze eye tracking data. We conducted eye tracking experiments using objects in three-dimensional space to find an objective way to process quantitative visual data. By applying a 12 × 12 grid framework for eye tracking analysis, we investigated how people gazed at objects in a virtual space wearing a headmounted display. The findings provide an empirical base for a standardized protocol for analyzing eye tracking data in the context of virtual environments.