• 제목/요약/키워드: bridge-abutment system

검색결과 47건 처리시간 0.022초

임상가를 위한 특집 3 - 심하게 흡수된 치조제를 가진 환자에서 CAD/CAM을 이용한 임플란트 고정성 보철치료 (Implant fixed prosthetic treatment using CAD/CAM system in a patient with severe alveolar resorption)

  • 최유성
    • 대한치과의사협회지
    • /
    • 제50권3호
    • /
    • pp.126-139
    • /
    • 2012
  • Loss of dentition can lead to not only compromised esthetics and functions of the patient, but also alveolar bone resorption. Bone grafting with prosthetic reconstruction of the gingiva can be selected for the treatment, and it provides many benefits as prosthetic gingival reconstruction does not require a complicated surgical process and is available within a short period of time, with stable clinical results. However, conventional porcelain fused to metal prosthesis has certain limits due to its size, and deformation after several firing procedures. In this clinical report, the author would like to introduce a patient with severe alveolar resorption who was treated with gingiva-shaped zirconia/titanium CAD/CAM implant fixed prosthesis for esthetic and functional rehabilitation. Clinical reports Clinical report 1, 2 : A case of loss of anterior dentition with atrophied alveolar bone. Implant retained zirconia bridge applied with Procera implant bridge system to simulate the gingiva. Upper structure was fabricated with zirconia all ceramic crown. Clinical report 3, 4 : A case of atrophied maxillary alveolus was reconstructed with fixed implant prosthesis, a CAD/CAM designed titanium structure covered wi th resin on its surface. Anterior dentition was reconstructed with zirconia crown. Conclusion and clinical uses. All patients were satisfied with the outcome, and maintained good oral hygiene. Zirconia/titanium implant fixed prosthesis fabricated by CAD/CAM system was highly accurate and showed adequate histological response. No critical failure was seen on the implant fixture and abutment overall. Sites of severe alveolar bone loss can be rehabilitated by implant fixed prosthesis with CAD/CAM system. This type of prosthesis can offer artificial gingival structure and can give more satisfying esthetics and functions, and as a result the patients were able to accept the outcome more fondly, which makes us less than hard to think that it can be a more convenient treatment for the practitioners.

교량공사를 중심으로 한 범용 프로젝트 관리를 위한 전산 입력 자료 모형 구축 (A Study on A Computerized Input Data Model for A General -Purpose Project Management)

  • Park, Hongtae
    • 한국재난정보학회 논문집
    • /
    • 제12권1호
    • /
    • pp.19-31
    • /
    • 2016
  • 본 연구는 범용 프로젝트 관리 및 운영을 위해 범용 프로젝트 관리 전산시스템에 적용할 수 있는 초기 전산관리용 데이터베이스를 구축하였다. 본 연구에서 제시한 데이터베이스 구축 모형은 시설요소, 구조요소, 공사요소, 자원요소의 조직정보분류체계를 근거로 2교대 3경간의 교량공사를 조직분류체계, 활동, 자원별 활동의 계층으로 표현하여 구축하였다. 본 연구에서 구축된 데이터베이스 모형은 향후 범용 프로젝트 관리 및 운영을 위해서 매우 체계적이고 과학적인 관리로 활용할 수 있을 것으로 사료된다.

보철물 조건에 따른 Periotest수치의 실험적 평가 (IN VITRO EVALUATION OF PERIOTEST VALUES UNDER VARIOUS CONDITIONS OF PROSTHESES)

  • 한중석
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.793-800
    • /
    • 1997
  • Periotest(Siemens, Germany) has been used to test mobility of the implants clinically, however the effects of target materials and connection methods on the PTVs(Periotest Values) have not been evaluated. Periotest has been regarded as a reliable and objective tool to test implant and natural teeth mobility clinically, however this instrument showed different PTVs under various test conditions. This in vitro study was designed to compare PTVs of different veneering materials and prosthodontic designs (single and bridge restorations). To compare the effects of veneering materials on PTVs, 1 mm thickness of five different testing materials (porcelain, type III gold alloy, pure titanium, composite resin, acrylic resin) were placed on the resin block. Three full length of 13 mm Mark II implant fixtures were embedded into autopolymerizing resin block to fabricate single and bridge restorations. To evaluate effects of the connection method in single restorations, PTVs of screw retained(UCLA type) and cementation type(Cera-One system) were compared. Finally, to test reliability of PTVs of the final restorations, screw retained three unit short span PFM bridges were fabricated on the standard and Estheti-Cone abutments. All testing components were tightened with torque controller and PTVs of all specimens were measured 15 times for statistical analysis with SAS program. Following conclusions were made within the limit of this in vitro study. 1. PTVs of type III gold alloy, grade II titanium, composite resin veneering materials showed no significant differences, however acrylic resin and porcelain showed significant differences (P<0.05). 2. Single tooth restorations showed consistent PTVs as long as proper torque force was applied. 3. PTVs of bridge type prostheses was inconsistent regardless of abutment types. 4. PTVs of the prostheses showed higher scores and standard deviations than those of abutments regardless types of connection (P<0.05).

  • PDF

교량에서의 세굴깊이 산정 및 산정치와 실측치의 비교분석 (Estimation of Scour Depth at Bridnges and Comparative Analysis between Estimated and Measured Scour Depths)

  • 윤용남;이재수;호정석
    • 한국수자원학회논문집
    • /
    • 제30권5호
    • /
    • pp.477-485
    • /
    • 1997
  • 최근에 국내외적으로 발생한 교각과 교대에서의 세굴로 인한 교량의 붕괴는 보다 나은 세굴깊이 산정방법에 대한 필요성을 강조하고 있다. 본 논문에서는 미국 연방고속도로국에서 발간한 HEC-18에서 제시하는 절차를 바탕으로 1차원 모형인 WSPRO 모형과 HEC-2 모형, 그리고 2차원 모형인 TABS-MD 모형을 사용하여 남한강에 위치하고 있는 남한강교에 대한 수리분석을 비교하였다. 본 연구에서는 또한 1차원 및 2차원 모형으로부터 구한 수리량을 사용하여 산정한 세굴깊이를 비교하였다. 이와 동시에 홍수를 전후하여 음향측심기인 Fathometer(DE-719C)를 사용하여 현장실측을 수행하였다. 교량에서의 예측한 세굴깊이와 측정된 세굴깊이를 또한 비교하였다. 본 연구의 결과 실험실과 현장조건사이의 차이 때문에 산정된 세굴깊이와 실측된 세굴깊이 간에는 많은 차이를 보이고 있다. 또한 되메움현상 때문에 최대세굴깊이를 정확히 측정하기가 어렵다. 따라서 첨두 홍수시 사용할 수 있는 세굴측정장비의 개발과 국내 하천에 적합한 경험식을 개발하는 것이 시급하다고 본다.

  • PDF

BIOMECHANICS OF ABUTMENTS SUPPORTING REMOVABLE PARTIAL DENTURES UNDER UNILATERAL LOADING

  • Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Jeong-Taek;Roh, Hyun-Ki;Kim, Hyo-Jin;Lee, Seok-Hyung;Lee, Joo-Hee
    • 대한치과보철학회지
    • /
    • 제45권6호
    • /
    • pp.753-759
    • /
    • 2007
  • Statement of problem. In distal extension removable partial denture, the preservation of health of abutment teeth is very important, but abutment teeth are subjected to unfavorable stress under unilateral loading specially. Purpose. The purpose of this study was to investigate the biomechanical effects of mandibular removable partial dentures with various prosthetic designs under unilateral loading, using strain gauge analysis. Material and methods. Artificial teeth of both canines were anchored bilaterally in a mandibular edentulous model made of resin. Bilateral distal extension removable partial dentures with splinted and unsplinted abutments were fabricated. Group 1: Clasp-retained mandibular removable partial denture with unsplinted abutments Group 2: Clasp-retained mandibular removable partial denture with splinted abutments by 6-unit bridge. Group 3: Bar-retained mandibular removable partial denture Strain gauges were bonded on the labial plate of the mandibular resin model, approximately 2 mm dose to the abutments. Two unilateral vertical experimental loadings (30N and 100N) were applied subsequently via miniature load cell that were placed at mandibular left first molar region. Strain measurements were performed and simultaneously monitored from a computer connected to data acquisition system. For within-group evaluations, t-test was used to compare the strain values and for between-group comparisons, a one-way analysis of variance (ANOVA) was used and Tukey test was used as post hoc comparisons. Results. The strain values of group 1 and 2 were tensile under loadings. In contrast, strain values of group 3 were compressive in nature. Strain values increased as the applied load in increased from 30N to 100N (p<.05) except for right side in group 1. Under 30N loading, in left side, group 1 showed higher strain values than groups 2 and 3 in absolute quantity (p<.05). And group 2 showed higher strain values than group 1 (p<.05). In right side, group 1 and 2 showed higher strain values than group 3 in absolute quantity (p<.05). Under 100N loading in left side, group 1 showed higher strain values than groups 2 and 3 in absolute quantity (p<.05). And group 2 showed higher strain values than group 1 (p<.05). In right side, group 1 and 2 showed higher strain values than group 3 in absolute quantity (p<.05). Under 30N loading, group 2 and 3 showed higher strain values in right side than in left side. Under 100N loading, right side strain values were higher than left side ones for all groups. Conclusion. Splinting of two isolated abutments by bridge reduced the peri-abutment strain in comparison with unsplinted abutments under unilateral loading. Bar-retained removable partial denture showed the lowest strain of three groups, and compressive nature.

COMPARATIVE ACCURACY OF THE SPLINTED AND UNSPLINTED IMPRESSION METHODS FOR INTERNAL CONNECTION

  • Choi, Jung-Han;Kim, Chang-Whe;Jang, Kyung-Soo;Lim, Young-Jin
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.352-362
    • /
    • 2005
  • Statement of problem. Accurate impression is essential to success of implant prostheses. But there have been few studies about the accuracy of fixture-level impression techniques in internal connection implant systems. Purpose. The purpose of this study was to compare the accuracy of two fixture-level impression techniques in two conditions (parallel and divergent) and to assess the effect of tightening sequences and forces on stresses generated on superstructures in internal connection implant system (Astra Tech). Material and methods. Two metal master frameworks made from two abutments (Cast-to Abutment ST) each and a corresponding, passively fitting, dental stone master cast with four fixture replicas (Fixture Replica ST) were fabricated. Ten dental stone casts for each impression techniques (direct unsplinted & splinted technique) were made with vinyl polysiloxane impressions from the master cast. Strain gauges for each framework were fixed midway between abutments to measure the degree of framework deformation on each stone cast. Pairs of strain gauges placed opposite each other constituted one channel (half Wheatstone bridge) to read deformation in four directions (superior, inferior, anterior, and posterior). Deformation data were analyzed using one-way ANOVA and the Tukey test at the .01 level of significance. And the effect of tightening sequences (right-to-left and left-to-right) and forces (10 Ncm and 20 Ncm) were assessed with ten stone casts made from parallel condition by the splinted technique. Deformation data were analyzed using paired t-test at the .01 level of significance. Conclusions. Within the limitations of this study, the following conclusions could be drawn. 1. Frameworks bent toward the inferior side on all casts made by both direct unsplinted and splinted impression techniques in both parallel and divergent conditions. 2. There was no statistically significant difference of accuracy between the direct unsplinted and splinted impression techniques in both parallel and divergent conditions (P>.01). 3. There was no statistically significant difference of stress according to screw tightening sequences in casts made by the splinted impression technique in parallel condition (P>.01). 4. Greater tightening force resulted in greater stress in casts made by the splinted impression technique in parallel condition (P<.01).

다양한 CAD/CAM 시스템으로 제작된 3 본 고정성 가공의치 지르코니아 코어의 변연 및 내면 적합도 평가 (Marginal and internal fitness of three-unit zirconia cores fabricated using several CAD/CAM systems)

  • 허중보;김우식;김하영;김종은;이정렬;김영수;전영찬;신상완
    • 대한치과보철학회지
    • /
    • 제49권3호
    • /
    • pp.236-244
    • /
    • 2011
  • 연구 목적: 본 연구는 다양한 CAD/CAM 시스템에 의해 제작된 지르코니아를 이용한 3-unit 브릿지 코어의 적합도를 "Replica Technique"으로 측정하여 기존 제품들의 내면 및 변연 적합도를 평가해 각 시스템의 적합 특성을 알아보고 임상 적용에 참고 자료로 활용하고자 시행하였다. 연구 재료 및 방법: 상악 좌측 제1소구치를 결손치로 하고 상악 좌측 견치, 상악 좌측 제2소구치를 지대치로 하는 3-unit 고정성 가공의치를 구현한 티타늄 모형을 제작하고, 40개의 실험 모형을 제작하였다. 각 모형을 10개씩 분류하고 Cerasys$^{(R)}$ (C군), Dentaim$^{(R)}$ (D군), KaVo Everest$^{(R)}$ (K군), $Lava^{TM}$ (L군)시스템으로 각각 지르코니아 코어를 제작하였다. 제작된 코어는 각 지대치마다 내면에 16개의 점을 선택하고 "Replica Technique"을 이용하여 각 포인트의 간극을 측정하였고 부위별 측정치를 비교, 평가하였다. Two-way ANOVA와 Dunnett T3 analysis를 이용하여 통계 분석하였다(${\alpha}$=.05). 결과: 모든 시스템에서 변연의 외부보다 내부에서 조금 더 큰 간극을 보이는 특징을 보였다. K군의 경우 전반적인 적합도는 우수하였으나 절단부위의 간극이 아주 크게 나타나는 특징을 보였고, C군의 경우 변연부위의 간극은 K군와 비교하여 크지만(P<.05) 전반적인 내면 간극이 다른 시스템에 비해 균일한 특징을 보였다. 축벽의 간극에서는 모든 시스템, 모든 절단부위에서 $100\;{\mu}m$ 미만의 우수한 적합도를 보였다. L군와 C군의 경우 변연의 외측부와 내측부의 간극차이가 적었으나 KaVo Everest$^{(R)}$와 Dentaim$^{(R)}$의 경우 마진 내측이 외측보다 간극이 큰 특징을 보였다(P<.05). 변연과 내면적합도로 나누어 분석하였을 때 K군과 C군이 D군과 L군보다 상대적으로 더 좋은 변연 및 내면 적합도를 보였고(P<.05) 두 지대치 중 견치가 제2소구치보다 더 좋은 적합도를 보였다(P<.05). 결론: 대부분의 시스템에서 변연 부위의 적합도는 임상적으로 허용 가능한 범위에 있었다. 변연 간극과 내면 간극 모두에서 지대치 중에 견치에서보다 제2소구치에서 더 큰 간극을 나타내었다. 또한 대부분의 시스템에서 축벽보다는 교합면 쪽 간극이 상대적으로 크게 형성되었다.