• Title/Summary/Keyword: bone screw fixation

Search Result 180, Processing Time 0.024 seconds

Bone Cement-Augmented Short Segment Fixation with Percutaneous Screws for Thoracolumbar Burst Fractures Accompanied by Severe Osteoporosis

  • Jung, Hyun Jin;Kim, Seok Won;Ju, Chang Il;Kim, Sung Hoon;Kim, Hyen Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.4
    • /
    • pp.353-358
    • /
    • 2012
  • Objective : The purpose of this study was to determine the efficacy of bone cement-augmented short segment fixation using percutaneous screws for thoracolumbar burst fractures in a background of severe osteoporosis. Methods : Sixteen patients with a single-level thoracolumbar burst fracture (T11-L2) accompanying severe osteoporosis treated from January 2008 to November 2009 were prospectively analyzed. Surgical procedures included postural reduction for 3 days and bone cement augmented percutaneous screw fixation at the fracture level and at adjacent levels without bone fusion. Due to the possibility of implant failure, patients underwent implant removal 12 months after screw fixation. Imaging and clinical findings, including involved vertebral levels, local kyphosis, canal encroachment, and complications were analyzed. Results : Prior to surgery, mean pain score (visual analogue scale) was 8.2 and this decreased to a mean of 2.2 at 12 months after screw fixation. None of the patients complained of pain worsening during the 6 months following implant removal. The percentage of canal compromise at the fractured level improved from a mean of 41.0% to 18.4% at 12 months after surgery. Mean kyphotic angle was improved significantly from $19.8^{\circ}$ before surgery to 7.8 at 12 months after screw fixation. Canal compromise and kyphotic angle improvements were maintained at 6 months after implant removal. No significant neurological deterioration or complications occurred after screw removal in any patient. Conclusion : Bone cement augmented short segment fixation using a percutaneous system can be an alternative to the traditional open technique for the management of selected thoracolumbar burst fractures accompanied by severe osteoporosis.

Ten technical aspects of baseplate fixation in reverse total shoulder arthroplasty for patients without glenoid bone loss: a systematic review

  • Reinier W.A. Spek;Lotje A. Hoogervorst;Rob C. Brink;Jan W. Schoones;Derek F.P. van Deurzen;Michel P.J. van den Bekerom
    • Clinics in Shoulder and Elbow
    • /
    • v.27 no.1
    • /
    • pp.88-107
    • /
    • 2024
  • The aim of this systematic review was to collect evidence on the following 10 technical aspects of glenoid baseplate fixation in reverse total shoulder arthroplasty (rTSA): screw insertion angles; screw orientation; screw quantity; screw length; screw type; baseplate tilt; baseplate position; baseplate version and rotation; baseplate design; and anatomical safe zones. Five literature libraries were searched for eligible clinical, cadaver, biomechanical, virtual planning, and finite element analysis studies. Studies including patients >16 years old in which at least one of the ten abovementioned technical aspects was assessed were suitable for analysis. We excluded studies of patients with: glenoid bone loss; bony increased offset-reversed shoulder arthroplasty; rTSA with bone grafts; and augmented baseplates. Quality assessment was performed for each included study. Sixty-two studies were included, of which 41 were experimental studies (13 cadaver, 10 virtual planning, 11 biomechanical, and 7 finite element studies) and 21 were clinical studies (12 retrospective cohorts and 9 case-control studies). Overall, the quality of included studies was moderate or high. The majority of studies agreed upon the use of a divergent screw fixation pattern, fixation with four screws (to reduce micromotions), and inferior positioning in neutral or anteversion. A general consensus was not reached on the other technical aspects. Most surgical aspects of baseplate fixation can be decided without affecting fixation strength. There is not a single strategy that provides the best outcome. Therefore, guidelines should cover multiple surgical options that can achieve adequate baseplate fixation.

Straight-Forward versus Bicortical Fixation Penetrating Endplate in Lumbosacral Fixation-A Biomechanical Study

  • Karakasli, Ahmet;Acar, Nihat;Uzun, Bora
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.2
    • /
    • pp.180-185
    • /
    • 2018
  • Objective : Many lumbosacral fixation techniques have been described to offer a more screw-bone purchase. The forward anatomical fixation parallel to the endplate is still the most preferred method. Literature revealed little knowledge regarding the mechanical stability of lumbosacral trans-endplate fixation compared to the traditional trans-pedicular screw fixation method. The aim of this study is to assess the pull-out strength of lumbosacral screws penetrating the end plate and comparing it to the conventional trans-pedicular screw insertion method. Methods : Eight lumbar and eight sacral vertebrae, with average age 69.4 years, Left pedicles of the 5th lumbar vertebrae were used for trans-endplate screw fixation, group 1A, right pedicles were used for anatomical trans-pedicular screw fixation, group 1B. In the sacral vertebrae, the right side S1 pedicles were used for trans-endplate fixation, group 2A, left side pedicles were used for anatomical trans-pedicular screw fixation, group 2B. The biomechanical tests were performed using the axial compression testing machine. All tests were applied using 2 mm/min traction speed. Results : The average pull-out strength values of groups 1A and 1B were $403.78{\pm}11.71N$ and $306.26{\pm}17.55N$, respectively. A statistical significance was detected with p=0.012. The average pull-out strength values of groups 2A and 2B were $388.73{\pm}17.03N$ and $299.84{\pm}17.52N$, respectively. A statistical significance was detected with p=0.012. Conclusion : The trans-endplate lumbosacral fixation method is a trustable fixation method with a stronger screw-bone purchase and offer a good alternative for surgeons specially in patients with osteoporosis.

Posterior Atalntoaxial Fusion with C1 Lateral Mass Screw and C2 Pedicle Screw Supplemented with Miniplate Fixation for Interlaminar Fusion : A Preliminary Report

  • Yoon, Sang-Mok;Baek, Jin-Wook;Kim, Dae-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.2
    • /
    • pp.120-125
    • /
    • 2012
  • Objective : To investigate the feasibility of C1 lateral mass screw and C2 pedicle screw with polyaxial screw and rod system supplemented with miniplate for interlaminar fusion to treat various atlantoaxial instabilities. Methods : After posterior atlantoaxial fixation with lateral mass screw in the atlas and pedicle screw in the axis, we used 2 miniplates to fixate interlaminar iliac bone graft instead of sublaminar wiring. We performed this procedure in thirteen patients who had atlantoaxial instabilities and retrospectively evaluated the bone fusion rate and complications. Results : By using this method, we have achieved excellent bone fusion comparing with the result of other methods without any complications related to this procedure. Conclusion : C1 lateral mass screw and C2 pedicle screw with polyaxial screw and rod system supplemented with miniplate for interlaminar fusion may be an efficient alternative method to treat various atlantoaxial instabilities.

Early Failure of Cortical-Bone Screw Fixation in the Lumbar Spinal Stenosis (요추부 협착에서의 피질골 궤도 나사못 고정의 초기 실패 사례에 대한 고찰)

  • Kwon, Ji-Won;Kim, Jin-Gyu;Ha, Joong-Won;Moon, Seong-Hwan;Lee, Hwan-Mo;Park, Yung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.5
    • /
    • pp.405-410
    • /
    • 2020
  • Purpose: Pedicle screw insertion has been traditionally used as a surgical treatment for degenerative lumbar spine disease. As an alternative, the cortical-bone trajectory screw allows less invasive posterior lumbar fixation and excellent mechanical stability, as reported in several biomechanical studies. This study evaluated the clinical and radiological results of a case of early failure of cortical-bone screw fixation in posterior fixation and union after posterior decompression. Materials and Methods: This study examined 311 patients who underwent surgical treatment from 2013 to 2018 using cortical orbital screws as an alternative to traditional pedicle screw fixation for degenerative spinal stenosis and anterior spine dislocation of the lumbar spine. Early fixation failure after surgery was defined as fixation failure, such as loosening, pull-out, and breakage of the screw on computed tomography (CT) and radiographs at a follow-up of six months. Results: Early fixation failure occurred in 46 out of 311 cases (14.8%), screw loosening in 46 cases (14.8%), pull-out in 12 cases (3.9%), and breakage in four cases (1.3%). An analysis of the site where the fixation failure occurred revealed the following, L1 in seven cases (15.2%), L2 in three cases (6.5%), L3 in four cases (8.7%), L4 in four cases (8.7%), L5 in four cases (8.7%), and S1 in 24 cases (52.2%). Among the distal cortical bone screws, fixation failures such as loosening, pull-out, and breakage occurred mainly in the S1 screws. Conclusion: Cortical-bone trajectory screw fixation may be an alternative with comparable clinical outcomes or fewer complications compared to conventional pedicle screw fixation. On the other hand, in case with osteoporosis and no anterior support structure particularly at L5-S1 fusion sites were observed to have result of premature fixation failures such as relaxation, pull-out, and breakage.

Biomechanical Comparative Study for Osteosynthesis of Pauwels Type III Femoral Neck Fractures: Conventional Devices versus Novel Fixed Angle Devices

  • Dae-Hyun Park;Young-Chae Seo;Yong-Uk Kwon;Soo-Hwan Jung;Seung-Jin Yoo
    • Hip & pelvis
    • /
    • v.34 no.1
    • /
    • pp.35-44
    • /
    • 2022
  • Purpose: Osteosynthesis has been recommended for treatment of Pauwels type III femoral neck fractures in young patients. However, no implant of choice has been reported so far. This study was conducted in order to compare the fixation stability of two conventional fixation methods with three different novel fixed angle devices in this type of fracture. Materials and Methods: A total of 25 composite femurs (4th Generation Saw bone; Pacific Research Laboratories, USA) corresponding to human bone were used. Pauwels type III fracture type was uniformly reproduced. Specimens were fixed with a cannulated screw, cannulated screw with cable, and Intertan nail, dynamic hip screw, and IKEY nail. Measurement of failure loads and the rotational change of the femoral head fragment was performed for evaluation of fixation stability. Results: All implants were compared with cannulated screw and dynmaic hip screw. No meaningful improvement was observed for the cannulated screw with cable compared with the cannulated screw and dynamic hip screw. Meaningful improvement in load-to-failure and y-rotation and z-rotation was observed for both the Intertan nail and IKEY nail compared with the cannulated screw. However, compared with the dynamic hip screw, only the IKEY nail showed improvement in the same profile but the Intertan nail did not. Conclusion: Among novel fixed angle devices, meaningful improvement was observed for the IKEY nail compared with conventional implants. Strengths of this implant include biomechanical stability and simplicity of surgical technique, indicating that it may be another good option for osteosynthesis of Pauwels type III femoral neck fractures.

Is All Anterior Oblique Fracture Orientation Really a Contraindication to Anterior Screw Fixation of Type II and Rostral Shallow Type III Odontoid Fractures?

  • Cho, Dae-Chul;Sung, Joo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.6
    • /
    • pp.345-350
    • /
    • 2011
  • Objective : It is debatable whether an anterior oblique fracture orientation is really a contraindication to anterior odontoid screw fixation. The purpose of this study was to investigate the feasibility of anterior odontoid screw fixation of type II and rostral shallow type III fracture with an anterior oblique fracture orientation. Methods : The authors evaluated 16 patients with type II and rostral shallow type III odontoid fracture with an anterior oblique fracture orientation. Of these 16 patients, 8 (group 1) were treated by anterior odontoid screw fixation, and 8 (group 2) by a posterior C1-2 arthrodesis. Results : Of the 8 patients in group 1, seven patients achieved solid bone fusion (87.5%), and one experienced screw back-out of the C-2 body two months after anterior screw fixation. All patients treated by posterior C1-C2 fusion in group 2 achieved successful bone fusion. Mean fracture displacements and fracture gaps were not significantly different in two groups. (p=0.075 and 0.782). However, mean fracture orientation angles were $15.3{\pm}3.2$ degrees in group 1, and $28.6{\pm}8.1$ degrees in group 2 (p=0.002), and mean fragment angulations were $3.2{\pm}2.1$ degrees in group 1, and $14.8{\pm}3.7$ degrees in group 2 (p=0.001). Conclusion : Even when the fracture lines of type II and rostral shallow type III fractures are oriented in an anterior oblique direction, anterior odontoid screw fixation can be feasible in carefully selected patients with a relatively small fracture orientation angle and relatively small fragment angulation.

Removal of broken syndesmotic screw with minimal bone defects in Korea: a case report

  • Min Gyu Kyung;Chulhee Park
    • Journal of Trauma and Injury
    • /
    • v.36 no.3
    • /
    • pp.265-268
    • /
    • 2023
  • Ankle fractures with syndesmotic injuries often require fixation, where metal screw fixation is a popular method. However, as the patient begins weight-bearing, most syndesmotic screws tend to loosen or break, and removal of such screws has been challenging for the surgeons, as the available techniques require predrilling or trephination and are associated with risks of bone damage. This study presents a case with technical tip for the removal of broken tricortical-fixed non-cannulated syndesmotic screws. It implements the generation of a small cortical window in the medial distal tibia and the use of pliers to engage the screw tip and remove through the medial side. The technique presented in the current study overcomes these limitations and facilitates minimal bone damage and reduced exposure to radiation.

The influence of screw type and osseointegration ratio on stress distribution in two different endosseous implants

  • Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.3
    • /
    • pp.348-357
    • /
    • 2000
  • The purpose of this study is to examine the effect of partial osseointegration situation on bone loading patterns around two different free-standing screw shaped implants (Nobel Biocare, Gothenburg, Sweden and Degussa-Huls, Hanau, German). Two dimensional axisymmetric Finite element models of two implants(10mm length and 4mm diameter) were created according to different bone quantity, quality and osseointegration ratio in maxilla and mandible bone. At the same time uni-cortical and hi-cortical fixation were analyzed. Generally, full bond case showed less stress than partial bond case in overall area and mandibular model showed less amount of stress than that of maxilla model. Maximum stress of the Branemark implant is higher than that of ANKYLOS regardless of bonding ratio at crestal and apex region. However, more stress concentration was noted in ANKYLOS implant at screw body area especially in mandible. The effect of bicortical fixation on crestal bone stress reduction is dramatical in mandible however, there was no significant effect in maxillary case. The effect of partial bond on stress distribution was more significant at screw body and apex region than in crestal region. Partial bond cases demonstrated greater stress accumulation in trabecular bone than cortical bone. It is concluded that the more accurate model of implant and bone which affects stress and strain distribution is needed to mimic in vivo behavior of implants.

  • PDF

The Results and Complications of the C1-C2 Transarticular Screw Fixation Methods (축추-환추간 경관절 나사못 고정술 치료의 결과 및 합병증)

  • Choi, Jun-Woong;Yoon, Seung-Hwan;Park, Hyung-Chun;Park, Hyeon-Seon;Kim, Eun-Young;Ha, Yoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.3
    • /
    • pp.201-206
    • /
    • 2005
  • Objective: To evaluate the accuracy and safety of C1-C2 transarticular screw insertion, we retrospectively review surgical records and postoperative radiological findings. Methods: From January 2001 to October 2003, the C1-C2 transarticular screw fixation and posterior wiring with iliac bone grafts was performed in 16 patients. 6 patients had rheumatoid arthritis which caused cervical instability, 3 patients had os odontoideum, 3 patients had type 2 odontoid process fracture, 3 patients had traumatic transverse ligament injury and 1 patients who had been managed with C1-C2 wire fixation had psoriatic arthritis. Results: Osseous fusion was documented in 15 patients(93.8%). Only one patient was recorded screw loosening because of postoperative infection. One patient had only one screw placed because of abnormal anatomical structure, one patients was breakage of a Kirschner wire, and one screw was medial location to lateral mass of C1, but clinical results was excellent and radiological instability was not noted. Conclusion: The author's experience demonstrates that C1-C2 transarticular screw fixation with wired bone graft is a safe procedure with higher fusion rate but precaution is needed to avoid the neural damage, vertebral artery injury, and hardware failure.