• Title/Summary/Keyword: bone exposure

Search Result 384, Processing Time 0.024 seconds

Relationships between Intakes of Soybean Food, Dietary Isoflavone and Osteoporosis Incidence among Postmenopausal Women in Daejeon City (대전시 일부 폐경 후 여성의 두류 및 식이 이소플라본 섭취와 골다공증간의 관계 연구)

  • Woo, Soon-Sun;Kim, Sun-Hyo
    • Journal of the Korean Society of Food Culture
    • /
    • v.24 no.6
    • /
    • pp.588-596
    • /
    • 2009
  • To determine the relationships between soybean food intake, dietary isoflavone intake, and osteoporosis incidence, questionnaire surveys, bone mineral density measurements, and dietary surveys by food record were performed with 19 postmenopausal women ($57.6{\pm}7.3$ yrs of age) in Daejeon city. The subjects were divided into two groups: an 'osteoporosis group' (OG, n=10) and a 'normal group' (NG, n=9). Mean age, height, and body weight were similar between the two groups but BMI was higher in OG than in NG. Mean age at menarche was not different between the two groups. However, mean number of childbirths was greater in OG than in NG and mean total period of lactation was shorter in OG. Mean exercise time per week was similar between the two groups, and mean time of sunlight exposure tended to be shorter in OG. Mean daily intake of calcium was lower in OG whereas sodium intake was higher in OG. Mean daily intakes of total soybean food (OG: $203.8{\pm}84.6\;g/d$, NG: $285.0{\pm}146.3\;g/d$) and total dietary isoflavone (OG: $29.1{\pm}14.3\;mg/d$, NG: $38.3{\pm}23.1\;mg/d$) were not different between the two groups. However, greater intakes of soybean food and dietary isoflavone were associated with higher bone mineral density, respectively. The above results indicate that osteoporosis incidence tends to be influenced by BMI, maternal factors, dietary nutrient intakes, soybean food intakes, and dietary isoflavone intakes in postmenopausal women; although no significant differences in soybean food and dietary isoflavone intake were found between the two groups. This tendency implies that greater intakes of soybean food and dietary isoflavone lead to lower incidence of osteoporosis in postmenopausal women.

Prolonged Exposure to Lipopolysaccharide Induces NLRP3-Independent Maturation and Secretion of Interleukin (IL)-1β in Macrophages

  • Hong, Sujeong;Yu, Je-Wook
    • Journal of Microbiology and Biotechnology
    • /
    • v.28 no.1
    • /
    • pp.115-121
    • /
    • 2018
  • Upon sensing of microbial infections or endogenous danger signals in macrophages, inflammasome signaling plays a significant role in triggering inflammatory responses via producing interleukin (IL)-$1{\beta}$. Recent studies revealed that active caspase-1, a product of the inflammasome complex, causes maturation of inactive pro-IL-$1{\beta}$ into the active form. However, the underlying mechanism by which this leaderless cytokine is secreted into the extracellular space remains to be elucidated. In this study, we demonstrated that prolonged lipopolysaccharide (LPS) treatment to macrophages could trigger the unexpected maturation and extracellular release of IL-$1{\beta}$ through a nucleotide-binding oligomerization domain-like receptor family, pyrin domain-containing 3 (NLRP3)-independent manner. Short-term treatment (less than 6 h) of LPS induced robust production of the IL-$1{\beta}$ precursor form inside cells but did not promote the maturation and secretion of IL-$1{\beta}$ in bone marrow-derived macrophages or peritoneal macrophages. Instead, prolonged LPS treatment (more than 12 h) led to a significant release of matured IL-$1{\beta}$ with no robust indication of caspase-1 activation. Intriguingly, this LPS-triggered secretion of IL-$1{\beta}$ was also observed in NLRP3-deficient macrophages. In addition, this unexpected IL-$1{\beta}$ release was only partially impaired by a caspase-1 and NLRP3 inflammasome inhibitor. Collectively, our results propose that prolonged exposure to LPS is able to drive the maturation and secretion of IL-$1{\beta}$ in an NLRP3 inflammasome-independent manner.

Development and use of Supporting Device for Patellar X-ray Imaging (슬개골 엑스선 영상 촬영을 위한 보조기구의 개발과 활용)

  • Rhee, Do-Byung;Seo, Seung-Jun;Choi, Hyun-Woo;Lee, Sang-Hun;Kim, Jong-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.4
    • /
    • pp.165-171
    • /
    • 2020
  • In this study, it focuses on the development of radiographic devices for patellar imaging. On the previous X-ray examination of patella and patellofemoral joint, it analyzed the problems which could affect the results: unstable patients' pose, radiation exposure, and deterioration of image quality. The purpose of the research is to propose a future use of a developed device with an explanation of the process, function, and advantage of the device including the methods. The device is developed to focus on the diagnosis of the longitudinal and longitudinal fractures of the patella and patella/femoral joint, displacement such as dislocation, bone formation, stenosis of the patella/femorla joint, and cartilage wear. Due to the patient's anxious posture, it caused a shaking image, overlapping structures, and etcs, these factors challenge to diagnose accurately. In addition, the existing Settegast method and Hughston method, which are most frequently performed in the hospital field, are not suitable for the presence or absence of features or dislocation due to the heavy load on the patella of the patient. The developed device requires patients in a lying position and placing only their leg on the device, it increases the conveniences of the examination and decreases unnecessary radiation exposure of the patient except the patellar examination area. Moreover, one of the systems in the device fixes the detector, where the patients no longer need to hold the detector nor be in unstable posture, but describes the structure of the patella/femoral joint more clearly. Hoping the device will apply to more patients.

Evaluation of the relationship between upper incisor exposure and cephalometric variables in Korean young adults

  • Han, Sung-Hoon;Lee, Eon-Hwa;Cho, Jin-Hyoung;Chae, Jong-Moon;Kim, Sang-Cheol;Chang, Na-Young;Kang, Kyung-Hwa
    • The korean journal of orthodontics
    • /
    • v.43 no.5
    • /
    • pp.225-234
    • /
    • 2013
  • Objective: The purpose of this study was to classify Korean young adults into 3 groups on the basis of upper incisor exposure rates (UIERs) and to compare the skeletal, dental, and soft tissue variables. Methods: Samples were obtained from 127 students at the College of Dentistry, Wonkwang University in South Korea. Facial photographs of frontal posed smiles and lateral cephalograms of the subjects were taken. The subjects were divided into 3 groups on the basis of UIERs and 20 measurements were compared among the 3 groups. The correlations between the variables were determined. Results: Male and female subjects showed significant differences in the group distribution. Male subjects showed higher frequencies of low smiles, and female subjects showed higher frequencies of high smiles. The vertical height of the anterior alveolar process of the maxilla directly correlated with the UIER. However, the UIER showed no significant correlation with the vertical height of the anterior basal bone or the inclination of the upper incisor axis. In female subjects, the upper central incisor clinical crown length showed an inverse correlation with the UIER. However, this variable showed no significant correlation with the UIER in male subjects. Conclusions: The UIER was directly correlated with the levator muscle activity of the upper lip and inversely correlated with the upper lip thickness, yet there was no correlation between the UIER and upper lip length at rest.

Role of Selenium in Alteration of Erythrocyte Parameters in Bovine Fluorosis

  • Han, Bo;Yoon, Soon-Seek;Wu, Pei-Fu;Han, Hong-Ryul;Liang, Li-Cheng
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.6
    • /
    • pp.865-871
    • /
    • 2006
  • Signs of dental discolouration, difficulty in mastication, bony exostosis and debility were observed in cattle from Qingtongxia Ningxia, China where fluoride concentration in drinking water, soil, fodder, serum, bone, teeth, haircoat and urine were significantly higher than the corresponding health site. The problem of fluorosis in beef cattle is attributable to water containing toxic levels of fluoride. The objective of this paper was therefore to evaluate the influence of fluoride on erythrocyte parameters in cattle under high fluoride and low selenium conditions, as well as the protective efficacy of selenium exposure in feedstuff for bovine endemic fluorosis. Sixteen 6 to 7 year-old high fluoride beef cattle were randomly allotted into two groups each with eight cows: high fluoride control group, and supplemented with 0.25 mg/kg selenium per day for 83 days respectively. In addition, eight 6 to 7 year-old normal control beef cattle were selected from a non-high fluoride site. Blood samples were collected on day 0, 30 and 83 for erythrocyte parameters analysis and scanning electronic microscopy. The results indicated that erythrocytes, hemoglobin, packed cell volume values and $Na^+-K^+$ ATPase activity from affected cattle on the high fluoride site were significantly reduced during the period as compared with the corresponding samples of normal control cattle, a great number of echinocytes were present in peripheral blood, and subsequent anaemia. However, affected cattle exposed to selenium revealed increasable erythrocyte parameters, the extent of elevation in these values being dependent on the duration of supplementation with selenium. These findings suggest that fluoride exposure can cause erythrocyte damage, whereas selenium supplementation can antagonize fluoride-induced generation of free radicals and cumulative effects of lipid peroxidation in erythrocytes. Selenium supplementation may help to alleviate the possible hazards associated with bovine endemic fluorosis.

Effects of $CoCl_2$ on Osteogenic Differentiation of Human Mesenchymal Stem Cells

  • Moon, Yeon-Hee;Son, Jung-Wan;Moon, Jung-Sun;Kang, Jee-Hae;Kim, Sun-Hun;Kim, Min-Seok
    • International Journal of Oral Biology
    • /
    • v.38 no.3
    • /
    • pp.111-119
    • /
    • 2013
  • Objective. To investigate the effects of the hypoxia inducible factor-1 (HIF-1) activation-mimicking agent cobalt chloride ($CoCl_2$) on the osteogenic differentiation of human mesenchymal stem cells (hMSCs) and elucidate the underlying molecular mechanisms. Study design. The dose and exposure periods for $CoCl_2$ in hMSCs were optimized by cell viability assays. After confirmation of $CoCl_2$-induced HIF-$1{\alpha}$ and vascular endothelial growth factor expression in these cells by RT-PCR, the effects of temporary preconditioning with $CoCl_2$ on hMSC osteogenic differentiation were evaluated by RT-PCR analysis of osteogenic gene expression, an alkaline phosphatase (ALP) activity assay and by alizarin red S staining. Results. Variable $CoCl_2$ dosages (up to $500{\mu}M$) and exposure times (up to 7 days) on hMSC had little effect on hMSC survival. After $CoCl_2$ treatment of hMSCs at $100{\mu}M$ for 24 or 48 hours, followed by culture in osteogenic differentiating media, several osteogenic markers such as Runx-2, osteocalcin and osteopontin, bone sialoprotein mRNA expression level were found to be up-regulated. Moreover, ALP activity was increased in these treated cells in which an accelerated osteogenic capacity was also verified by alizarin red S staining. Conclusions. The osteogenic differentiation potential of hMSCs could be preserved and even enhanced by $CoCl_2$ treatment.

Versatile midfacial degloving approach in oral and maxillofacial surgery

  • Anunay, Pangarikar;Umamaheswari, G.;Prachi, Parab;Suresh, Kumar;Devarathnamma, M.V.
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.4
    • /
    • pp.192-198
    • /
    • 2019
  • Objectives: Oral and maxillofacial surgeons must gain mastery of various approaches to the midface due to the increasing incidence, complexity, and severity of presenting midfacial fractures. Unlike in the case of other body parts, the need to preserve facial aesthetics makes it more difficult for the surgeon to select an approach for managing the facial injuries. The midfacial degloving (MFD) approach is a combination of intraoral and intranasal incisions made to access the midface without any external incision. The aim of the present study was to evaluate the efficacy of MFD in maxillofacial surgery and to assess its advantages and complications. Materials and Methods: The MFD approach was used in five cases, with three cases treated with open reduction and internal fixation and two cases operated on for posttraumatic deformity. Nasal dorsum augmentation was completed in three cases and nasal osteotomy was performed in one case. The bicoronal flap technique was combined with MFD for frontal bone augmentation in one case. The intraoperative time required for flap completion and the ease of performing the planned procedures were noted. Postoperative evaluation was done for reduction, aesthetics, function, and complications. Results: Access was excellent for performing all planned procedures. Average time spent for flap elevation and exposure of the midface was 63 minutes. Complications like postoperative swelling, infraorbital nerve paresthesia, and intranasal crusting were all transient. No long-term complications like stenosis of the nose, sneer deformity, or weakness of the facial muscles were noticed. Additionally, no complications were noted when MFD was combined with bicoronal flap. Conclusion: Though the MFD approach is technically demanding and takes more time than other facial approaches, it should be learned and applied by maxillofacial surgeons in selective cases, as it provides complete exposure of the midface without facial scarring.

Radiation Dose Comparison according to Different Organ Characteristics at Same Scan Parameters Using CareDose 4D: An Adult and Pediatric Phantom Evaluation (CareDose 4D 사용 시 동일한 스캔조건에서 조직기반설정을 다르게 적용함에 따른 선량 비교: 성인과 소아팬텀 연구)

  • Kong, Hyo-Geum;Lee, Ki-Baek
    • Journal of radiological science and technology
    • /
    • v.42 no.4
    • /
    • pp.271-277
    • /
    • 2019
  • CareDose 4D which is the Siemens's Automatic Exposure Control (AEC) can adjust the level of radiation dose distribution which is based on organ characteristic unlike other manufacturer's AEC. Currently, a wide scan range containing different organs is sometimes examined at once (defined as one scan). The purpose of this study was to figure out which organ characteristic option is suitable when one scan method is utilized. Two types of anthropomorphic phantoms were scanned in the same range which were from frontal bone to carina level according to three different organ characteristics such as Thorax, Abdomen, and Neck. All scans and image reconstruction parameters were equally applied and radiation dose were compared. Radiation dose with Thorax organ characteristic was lower than that with Neck. Also, that with Abdomen oran characteristic was lower than Thorax. There were significant differences in radiation dose according to different organ characteristics at the same parameters (P<0.05). Usage of Neck organ characteristic had a result of the highest radiation dose to all phantom. On the other hand, utilization of Abdomen organ characteristic showed the lowest radiation dose. As a result, it is desirable to set appropriate organ characteristic according to examined body part when you checkup patients. Also, when you implement one scan method, selection of Abdomen-based organ characteristic has reduced more radiation dose compared with two different organ characteristic.

A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS (공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구)

  • Park Cheol;Lim Ju-Hwan;Cho In-Ho;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

Study of External Radiation Expose Dose on Hands of Nuclear Medicine Workers (핵의학 종사자에서 손 부위의 외부 피폭선량 연구)

  • Park, Jun-Chul;Pyo, Sung-Jae
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.141-149
    • /
    • 2012
  • The aims of this study are to assess external radiation exposed doses of body and hands of nuclear medicine workers who handle radiation sources, and to measure radiation exposed doses of the hands induced by a whole body bone scan with high frequency and handling a radioactive sources like $^{99m}Tc$-HDP and $^{18}F$-FDG in the PET/CT examination. Skillful workers, who directly dispense and inject from radiation sources, were asked to wear a TLD on the chest and ring finger. Then, radiation exposed dose and duration exposed from daily radiation sources for each section were measured by using a pocket dosimeter for the accumulated external doses and the absorbed dose to the hands. In the survey of four medical institutions in Incheon Metropolitan City, only one of four institutions has a radiation dosimeter for local area like hands. Most of institutions uses radiation shielding devices for the purpose of protecting the body trunk, not local area. Even some institutions were revealed not to use such a shielding device. The exposed doses on the hands of nuclear medicine workers who directly handles radioactive sources were approximately twice as much as those on the body. The radiation exposure level for each section of the whole body bone scan with high frequency and that of the PET/CT examination showed that radiation doses were revealed in decreasing order of synthesis of radioactive medicine and installation to a dispensing container, dispensing, administering and transferring. Furthermore, there were statistically significant differences of radiation exposure doses of the hands before and after wearing a syringe shielder in administration of a radioactive sources. In this study, although it did not reach the permissible effective dose for nuclear medicine, the occupational workers were exposed by relatively higher dose level than the non-occupational workers. Therefore, the workers, who closely exposed to radioactive sources should be in compliance with safety management regulations, and take actions to maximally reduce locally exposed dose to hands monitoring with ring TLD.