The Evaluation of TrueX Reconstruction Method in Low Dose (저선량에서의 TrueX 재구성 방법에 의한 유용성 평가)

  • Oh, Se-Moon;Kim, Kye-Hwan;Kim, Seung-Jeong;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.83-87
    • /
    • 2011
  • Purpose: Recently in diagnostics area PET/CT is using a variety of areas including oncology, as well as in cardiology, neurology, etc. While increasing in the importance of PET/CT, there are various researches in the image quality related to reconstruction method. We compared and tested Iterative 2D Reconstruction Method with True X Reconstruction method by Siemens through phantom experiment, so we can see increasing of clinical usefulness of PET/CT. Materials and Methods: We measured contrast ratio and FWHM due to evaluating images on dose and experiment using Biograph 40 True Point PET/CT (Siemens, Germany). Getting a result of contrast ratio and FWHM, we used NEMA IEC PET body phantom (Data Spectrum Corp.) and capillary tube. We used the current TrueX and the previous Iterative 2D algorithm for all images which have 10 minutes long. Also, a clinical suitability of parameter for Iterative 2D and a recommended parameter by Siemens for True X are applied to the experiment. Results: We tested FWHM using capillary tube. As a result, TrueX was less than Iterative 2D. Also, the differences of FWHM get bigger in low dose. On the other hand, we tested contrasts ratio using NEMA IEC PET body phantom. As a result, TrueX was better aspect than Iterative 2D. However, there was no difference in dose. Conclusion: In this experiment, TrueX get higher results of contrast ratio and spatial resolution than Itertive 2D through experiment. Also, in the reconstruction result through TrueX, TrueX had better aspect of resolution than Iterative 2D in low dose. However, contrast ratio had no specific difference. In other words, TrueX reconstruction method in PET/CT had higher clinical value in use because TrueX can reduce exposure of patient and had a better quality of screen.

  • PDF

A Study on Compensation for Imaging Qualities Having Artifact with the Change of the Center Frequency Adjustment and Transmission Gain Values at 1.5 Tesla MRI (1.5 Tesla 기기에서 중심주파수 조정과 송 신호강도(Transmission Gain)값 변화에 따른 인공물이 있는 자기공명영상의 질 보상에 관한 연구)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Park, Cheol-Soo;Lee, Sun-Yeob;Lee, Han-Joo
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.244-252
    • /
    • 2009
  • The purpose of this study is to compensate for susceptibility and a ferromagnetic body artifact using CFA and TGV on MR Imaging. A total of 30 patients (15 men and 15 women, mean age: 45 years) were performed on head and neck diseases. MR Unit used a 1.5T superconducting magnet (GE medical system, High Density). This study have investigated by changing with CFA and TGV (70, 90, 110, 130, 150) searching for compensation values about susceptibility and a ferromagnetic body artifact in 60 kg standards of body weight (p<0.05). As a quality results, Image qualities were obtained at different score from CFA and TGV (70, 90, 110, 130, $150=3.23{\pm}0.35$, $4.31{\pm}0.02$ $4.23{\pm}0.21$, $5.12{\pm}0.25$, $7.13{\pm}0.72$, $8.31{\pm}0.01$, $5.21{\pm}0.15$, $6.14{\pm}0.08$, $5.23{\pm}0.72$, $5.91{\pm}0.06$, p<0.05). Absolute CNRs (TG, CNRpre, CNRpost) were acquired with (70:$-1.44{\pm}0.11$, $-2.7{\pm}0.04$, 90:$-2.18{\pm}0.42$, $-4.41{\pm}0.43$, 110:$-2.89{\pm}0.43$, $-5.23{\pm}0.02$, 130:$-2.34{\pm}0.05$, $-5.26{\pm}0.01$, 150: $-2.09{\pm}0.08$, $-3.87{\pm}0.12$, p<0.05). In conclusions, this study could be compensated for metal and flow artifacts surrounding the tissues having artifact by changing CFA and TGV.

  • PDF

Characterization of a new commercial strain 'Guseol' by intra-specific hyphal anastomosis in Pleurotus ostreatus (계통간 교잡에 의한 느타리 품종 '구슬'의 육성 및 그 특성)

  • Yoo, Young-Bok;Kim, Eun-Jung;Kong, Won-Sik;Jang, Kab-Yeul;Shin, Pyung-Gyun
    • Journal of Mushroom
    • /
    • v.10 no.3
    • /
    • pp.109-114
    • /
    • 2012
  • To develop new variety of oyster mushroom, 63 intra-specific hybrids between the strain Suhan and #Nongi201 were developed using hyphal anastomosis technique in 2004. The Po2008-275 hybrid between the dikaryon strain 04-154(Suhan x #Nongi201) and the monokaryon strain derived from ASI2487 were developed using hyphal anastomosis in 2008. The Po2008-275 was shown the best cultural characteristics, selected to be a new variety and named as 'Guseol'. The new commercial strain, 'Guseol' had dark grey pilei and grows well under spring and autumn conditions in Korea. The fruiting bodies of 'Guseol' were of an excellent quality in that not only the stipe was thick and long but also the pileus was small and hard. The optimum temperatures for mycelial growth and fruiting body development were $25{\sim}30^{\circ}C$ and $10{\sim}16^{\circ}C$, respectively. Time period required for the initiation of the first fruiting body was about 3 to 5 days depending on the temperatures. The shape of fruiting body was thin funnel shape. Fruiting body production per box($43{\times}43{\times}12cm$) was about $1545{\pm}400.9g$ which was almost 137% quantity compared to that of parental strain 04-154. Relatively low temperature incubation ($11^{\circ}C$) resulted in the development of better quality of 'Guseol' mushrooms. When two different media including potato dextrose medium and mushroom complete medium were compared, the mycelial growth of this mushroom were much faster in mushroom complete medium. Similar results were observed with other variety '#Chunchu2'. Analysis of the genetic characteristics of the new commercial strain 'Guseol' showed a major DNA profile as that of the parental 04-154 when primer URP 1, primer URP 2 and primer URP 5 were used, but different to '#Chunchu2' that was used as a control. This new variety of the dark grey oyster mushroom had smart and high quality image that corresponds well to "health food". We therefore expect that this new strain will satisfy the consumers demand for variety and excellent mushrooms.

The Evaluation of Lateral Scatter Ray of Gamma Camera (Gamma Camera에 있어 측면 선란선의 영향에 대한 평가)

  • Kim, Jae-Il;Lee, Eun-Byeol;Cho, Seong-Wook;Noh, Kyeong-Woon;Kang, Keon-Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.46-50
    • /
    • 2018
  • Purpose Generally, a collimator that installed in front of detector set a direction of gamma ray and remove a scatter ray. By the way, a lateral or oblique scatter ray is detected into crystal through collimator. At this study, we will evaluate a mount of count and spectrums of lateral scatter ray. Materials and Methods We used the SKY LITE (philips, netherlands) as a gamma camera, and $^{99m}Tc$, 1.11 GBq point source as a phantom. we put this point source at backside 50 cm of detector. After acquiring this for 1 min, we turned a detector next 10 degrees. Likely this, we acquired images at every 10 degrees from $0^{\circ}$ to $360^{\circ}$, analyzed images and spectrums. In case of patient study, we choose a 3 phase bone scan patient who had a hand disease, because scatter rays from body would detect on crystal. After acquiring blood flow and blood pool images, we analyzed images and spectrums. Additional, we put a lead gown on patient's hand, body. And then we compared and evaluated 3 type blood pool images (non lead gown, lead gown on a hand and on body). Results In case of phantom study, scatter ray counts at backside ($270^{\circ}-90^{\circ}$) are same with a background count. By the way, counts of scatter ray of oblique side ($0^{\circ}-50^{\circ}$, $220^{\circ}-270^{\circ}$) are 100-600 cps, furthermore, counts at frontside are over 4 Mcps. In case of patient study, a counts of hand blood pool scan are 1510 cps. But counts of hand with lead gown on hands and on body are each 1554 cps, 1299 cps. Conclusion Therefore, even though there is a collimator in front of detector, lateral scatter rays detect on crystal and affect to images and spectrums. Especially, if there is a high activity source at outside of detector when we examine low activity organs like hands or foot, we have to shield and remove the source at outside for a good image.

A Kinematic Analysis on Lateral Break-Fall of Security Nartial Arts (경호무도 측방낙법의 운동학적 분석)

  • Kim, Yong-Hak;Lee, Sae-Hwan
    • Korean Security Journal
    • /
    • no.24
    • /
    • pp.53-66
    • /
    • 2010
  • This study aims to analyze kinematic variables regarding lateral break-fall quantitatively that can protect the body, prevent the injury and minimize the impact. To this end, three Hapkido, judo athletes of H University with experience of over 5 years were selected. Test was conducted through three dimensional image analysis by checking the time and order the subjects reach a mat. In this study, lateral break-fall was repeated five times and among them, the best movement was selected. The picture shot with high-speed camera was analyzed by using KWON3D ver. 3.1 program through three dimensional coordinate calculation based on DLT method and smoothing process of data. Study results were as follows. 1. With respect to time variables shown in lateral break-fall of A, B, C athletes, there is small difference in temporal variables and in the order the body reaches a mat. With respect to average value, hand is ($0.94{\pm}0.20$), elbow ($0.97{\pm}0.17$), hip ($0.97{\pm}0.18$), back ($0.98{\pm}0.18$), and shoulder ($1.04{\pm}0.16$). Time variable the body reaches a mat in lateral break-fall is in hand, elbow, hip, back and shoulder. 2. With respect to moving distance variables shown in lateral break-fall of A, B, C athletes, hand is ($34.33{\pm}34.59$), elbow ($52.00{\pm}26.06$), hip ($70.00{\pm}15.72$), back ($153.67{\pm}17.93$), and should ($130.67{\pm}29.02$). The fact that this study contributed to improving security martial arts technique and protecting the body by understanding the principle of lateral break-fall movement is of significance. In addition, the fact that this study provided systematic basic data for improving security martial arts technique is significant.

  • PDF

A Research of Standards for Radiopharmaceutical Doses in Pediatric Nuclear Medicine (소아 핵의학 검사 시 사용되는 방사성의약품의 양 산출 기준 조사)

  • Do, Yong-Ho;Kim, Gye-Hwan;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.47-50
    • /
    • 2009
  • Purpose: Presently, any exact standard of radiopharmaceutical doses in pediatric nuclear medicine doesn't exist in the universe. So hospitals are following by manual of vial kit or guidelines of America and Europe based on recommended adult doses adjusted for body mass (MBq/kg) or body surface area (MBq/$m^2$). However, especially for children younger than 1 year and heavier than 50 kg, it's hard to estimate exact dosage for those children. Materials and Methods: In order to obtain objective data of multipliers for pediatric studies, we surveyed 4 major hospitals in Korea. After receiving feedbacks, we changed dosage to multiplier. And we compared multipliers of Korea to America's and Europe's. Results: Most hospitals in Korea are following by body mass formula (MBq/kg). On the other hand, standards don't include proper factors for a child younger than 1 year and heavier than 50 kg. Multipliers for 3 kg children who are injected lower doses than needed are America:0.12, Europe:0.09, Korea:0.05, multipliers for 30 kg children who are injected proper doses are America:0.58, Europe:0.51, Korea:0.45 and multipliers for 60 kg children who are injected more doses than needed are America:0.95, Europe:0.95, Korea:0.91. Conclusions : Through the survey, when calculating doses for children, usually output doses are based on adult doses adjusted for body mass (MBq/kg) but research has shown that standards of all of the compared standards don't reflect exact multipliers for children younger than 1 year and heavier than 50 kg. Therefore, we should give an effort to reduce needless radiation exposure in children by establishing a proper doses standard and also developing better image reconstruction software.

  • PDF

F-18-FDG Whole Body Scan using Gamma Camera equipped with Ultra High Energy Collimator in Cancer Patients: Comparison with FDG Coincidence PET (종양 환자에서 초고에너지(511 keV) 조준기를 이용한 전신 F-18-FDG 평면 영상: Coincidence 감마카메라 단층 촬영 영상과의 비교)

  • Pai, Moon-Sun;Park, Chan-H.;Joh, Chul-Woo;Yoon, Seok-Nam;Yang, Seung-Dae;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.65-75
    • /
    • 1999
  • Purpose: The aim of this study is to demonstrate the feasibility of 2-[fluorine-18] fluoro-2-deoxy-D-glucose (F-18-FDG) whole body scan (FDG W/B Scan) using dual-head gamma camera equipped with ultra high energy collimator in patients with various cancers, and compare the results with those of coincidence imaging. Materials and Methods: Phantom studies of planar imaging with ultra high energy and coincidence tomography (FDG CoDe PET) were performed. Fourteen patients with known or suspected malignancy were examined. F-18-FDG whole body scan was performed using dual-head gamma camera with high energy (511 keV) collimators and regional FDG CoDe PET immediately followed it Radiological, clinical follow up and histologic results were correlated with F-18-FDG findings. Results: Planar phantom study showed 13.1 mm spatial resolution at 10 cm with a sensitivity of 2638 cpm/MBq/ml. In coincidence PET, spatial resolution was 7.49 mm and sensitivity was 5351 cpm/MBq/ml. Eight out of 14 patients showed hypermetabolic sites in primary or metastatic tumors in FDG CoDe PET. The lesions showing no hypermetabolic uptake of FDG in both methods were all less than 1 cm except one lesion of 2 cm sized metastatic lymph node. The metastatic lymph nodes of positive FDG uptake were more than 1.5 cm in size or conglomerated lesions of lymph nodes less than 1cm in size. FDG W/B scan showed similar results but had additional false positive and false negative cases. FDG W/B scan could not visualize liver metastasis in one case that showed multiple metastatic sites in FDG CoDe PET. Conclusion: FDG W/B scan with specially designed collimators depicted some cancers and their metastatic sites, although it had a limitation in image quality compared to that of FDG CoDe PET. This study suggests that F-18-FDG positron imaging using dual-head gamma camera is feasible in oncology and helpful if it should be more available by regional distribution of FDG.

  • PDF

Characterization of a new commercial strain 'Goni' by intra-specific hyphal anastomosis in Pleurotus ostreatus (계통간 교잡에 의한 백색느타리 품종 '고니'의 육성 및 그 특성)

  • Yoo, Young Bok;Lee, Sang Cheol;Kim, Eun Jung;Kong, Won Sik;Jang, Kab Yeul;Shin, Pyung Gyun
    • Journal of Mushroom
    • /
    • v.7 no.3
    • /
    • pp.130-134
    • /
    • 2009
  • To develop new white variety of Oyster mushroom, all white varieties which have been collected and kept in the lab were revived and screened their cultural characteristics. 84 intra-specific Oyster mushroom hybrids between the white-colored mutants Suhan and Wonhyeong were developed using hyphal anastomosis technique in 2007. The Po2007-63 ($2842-7{\times}0205-7$) was shown the best cultural characteristics, selected to be a new variety and named as 'Goni'. The new commercial strain, 'Goni' has white pilei and grows well under spring and autumn conditions in Korea. The fruiting bodies of 'Goni' are of an excellent quality in that not only the stipe is thick and long but also the pileus is small and hard. The optimum temperatures for mycelial growth and fruiting body development were $25-30^{\circ}C$ and $10-16^{\circ}C$, respectively. Time period required for the initiation of the first fruiting body is about 3 to 5 days depending on the temperatures. The shape of fruiting body is thin funnel shape. Fruiting body production per bottle was about $91{\pm}13$ g which is almost 97% quantity compared to that of other variety 'Miso'. Relatively low temperature incubation ($11^{\circ}C$) resulted in the development of better quality of 'Goni' mushrooms. When two different media including potato dextrose medium and mushroom complete medium were compared, the growth of mushroom were much faster in mushroom complete medium at $20-25^{\circ}C$, but not at $25^{\circ}C$. Similar results were observed with other variety 'Miso'. Analysis of the genetic characteristics of the new commercial strain 'Goni' showed a major DNA profile as that of the parental Suhan when primer URP 1 was used, but different to 'Miso' that was used as a control. When screens were performed with primer URP 2, DNA patterns were similar both to that of the parents and 'Miso'. This new variety of the white Oyster mushroom has a clean and fresh image that corresponds well to "health food". We therefore expect that this new strain will satisfy the consumers demand for variety and excellent mushrooms.

  • PDF

A Study on Sensibility Evaluation of Ceramic Surface: Comparison between Tactility and Visual Tactility (세라믹 표면의 감성 평가 연구: 촉감과 시각적 촉감의 비교를 중심으로)

  • Kim, Jihyun;Song, Min Jeong
    • Science of Emotion and Sensibility
    • /
    • v.19 no.2
    • /
    • pp.101-112
    • /
    • 2016
  • Selecting appropriate materials can be significantly important to make different image in the product and also give distinguished express to the users. A material for the ceramic product surface consists of the combination between a glaze and a body, and each attribution of materials and the way of the combination creates different texture and color. This study analyzes the difference between visually and tactually sensibility of ceramic surface to through the simulating both visual and tactual stimulation by verbal evaluation method. Totally 13 adjectives are selected from homepage of local and global ceramic product brand. And totally 12 ceramic samples are created with the consideration of color, glossiness and roughness. These 12 samples are the combination between four ceramic bodies (White porcelain, Celadon_c, Sancheong and Black soil) and three glazes (Transparent, Celadon_g, Black glaze). The respondents of first survey were asked to rub, touch and hold before evaluating the sensibility of ceramic surface and other respondents of second survey were asked to evaluate visual images of 9 samples which showed meaningfully difference from first survey. The surface which scored the highest sensibility with the first survey was 'pure' on a surface of White porcelain body with Transparent glaze, and the lowest was also 'pure' on a surface of Black soil body with Transparent glaze. The highest score in the second survey was the same result as the first survey, but the lowest scored 'casual' and the surface was Black soil body with Celadon glaze. By the comparison with two survey results, not every sensibility is same result shown as the first survey and the second survey, but the tactile sensibilities such as 'artistic', 'luxurious', 'sensuous', 'romantic' and 'mysterious' can be experienced by via visual materials of ceramic surfaces.

Building the Process for Reducing Whole Body Bone Scan Errors and its Effect (전신 뼈 스캔의 오류 감소를 위한 프로세스 구축과 적용 효과)

  • Kim, Dong Seok;Park, Jang Won;Choi, Jae Min;Shim, Dong Oh;Kim, Ho Seong;Lee, Yeong Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.76-82
    • /
    • 2017
  • Purpose Whole body bone scan is one of the most frequently performed in nuclear medicine. Basically, both the anterior and posterior views are acquired simultaneously. Occasionally, it is difficult to distinguish the lesion by only the anterior view and the posterior view. In this case, accurate location of the lesion through SPECT / CT or additional static scan images are important. Therefore, in this study, various improvement activities have been carried out in order to enhance the work capacity of technologists. In this study, we investigate the effect of technologist training and standardized work process processes on bone scan error reduction. Materials and Methods Several systems have been introduced in sequence for the application of new processes. The first is the implementation of education and testing with physicians, the second is the classification of patients who are expected to undergo further scanning, introducing a pre-filtration system that allows technologists to check in advance, and finally, The communication system called NMQA is applied. From January, 2014 to December, 2016, we examined the whole body bone scan patients who visited the Department of Nuclear Medicine, Asan Medical Center, Seoul, Korea Results We investigated errors based on the Bone Scan NMQA sent from January 2014 to December 2016. The number of tests in which NMQA was transmitted over the entire bone scan during the survey period was calculated as a percentage. The annual output is 141 cases in 2014, 88 cases in 2015, and 86 cases in 2016. The rate of NMQA has decreased to 0.88% in 2014, 0.53% in 2015 and 0.45% in 2016. Conclusion The incidence of NMQA has decreased since 2014 when the new process was applied. However, we believe that it will be necessary to accumulate data continuously in the future because of insufficient data until statistically confirming its usefulness. This study confirmed the necessity of standardized work and education to improve the quality of Bone Scan image, and it is thought that update is needed for continuous research and interest in the future.

  • PDF