Purpose : This study proposes the keyhole method in order to improve the time resolution of the proton resonance frequency(PRF) MR temperature monitoring technique. The values of Root Mean Square (RMS) error of measured temperature value and Signal-to-Noise Ratio(SNR) obtained from the keyhole and full phase encoded temperature images were compared. Materials and Methods : The PRF method combined with GRE sequence was used to get MR temperature images using a clinical 1.5T MR scanner. It was conducted on the tissue-mimic 2% agarose gel phantom and swine's hock tissue. A MR compatible coaxial slot antenna driven by microwave power generator at 2.45GHz was used to heat the object in the magnetic bore for 5 minutes followed by a sequential acquisition of MR raw data during 10 minutes of cooling period. The acquired raw data were transferred to PC after then the keyhole images were reconstructed by taking the central part of K-space data with 128, 64, 32 and 16 phase encoding lines while the remaining peripheral parts were taken from the 1st reference raw data. The RMS errors were compared with the 256 full encoded self-reference temperature image while the SNR values were compared with the zero filling images. Results : As phase encoding number at the center part on the keyhole temperature images decreased to 128, 64, 32 and 16, the RMS errors of the measured temperature increased to 0.538, 0.712, 0.768 and 0.845$^{\circ}C$, meanwhile SNR values were maintained as the phase encoding number of keyhole part is reduced. Conclusion : This study shows that the keyhole technique is successfully applied to temperature monitoring procedure to increases the temporal resolution by standardizing the matrix size, thus maintained the SNR values. In future, it is expected to implement the MR real time thermal imaging using keyhole method which is able to reduce the scan time with minimal thermal variations.
Kim, Ji Hyun;Nam, Ki Chang;Kim, Hojun;Nam, Yeon Gyo;Kim, You Jin;jo, Eun hye;Kwon, Bum Sun
Journal of Biomedical Engineering Research
/
v.42
no.3
/
pp.86-93
/
2021
Purpose: The purpose of this study is to find out the cognizance of medical device safety information (MDSI) monitoring in the hospital and oriental hospital workers, and the different aspect of MDSI between oriental medical devices and medical devices. Methods: The survey was performed both in the oriental medicine hospital and general hospital. The survey had 16 items; 2 items basic questions, 5 items in the awareness of MDSI, 5 items in the education of MDSI, 4 items in the necessity of defining oriental medical devices and differences between general and oriental medical devices. A total of 120 hospital worker were participated; 60 oriental medicine hospital workers and 60 general hospital workers. They had worked in the oriental medicine or general hospital associated with 'Medical Device Safety Monitoring Center, Dongguk University Ilsan Hospital' in 2019 and 2020. Results: The cognizance of MDSI was high both in oriental medicine hospital and general hospital workers and there were no significant differences between oriental medicine and general hospital workers. When we divided the hospital workers into the senior workers who had worked for over 3 years and junior workers for less than 3 years, the senior workers had higher awareness of MDSI than junior workers. However, the cognizance of education of MDSI was high which was not different between senior and junior workers. Both hospital workers thought that it was necessary to define oriental medicine device legally and the oriental medical device might have low risk and less side effect than medical device. Conclusion: The cognizance of MDSI was high and there was no significant differences between oriental medicine and general hospital workers. Because the senior hospital workers had higher recognition of MDSI, we need to provide the continuous education program for junior hospital workers. Although oriental medical device are thought to be safer than medical device, we need to have a legal definition.
Kim, Jong Won;Huh, Up;Song, Seunghwan;Sung, Sang Min;Hong, Jung Min;Cho, Areum
Journal of Chest Surgery
/
v.52
no.6
/
pp.392-399
/
2019
Background: The surgical strategies for carotid endarterectomy (CEA) vary in terms of the anesthesia method, neurological monitoring, shunt usage, and closure technique, and no gold-standard procedure has been established yet. We aimed to analyze the feasibility and benefits of CEA under regional anesthesia (RA) and CEA under general anesthesia (GA). Methods: Between June 2012 and December 2017, 65 patients who had undergone CEA were enrolled, and their medical records were prospectively collected and retrospectively reviewed. A total of 35 patients underwent CEA under RA with cervical plexus block, whereas 30 patients underwent CEA under GA. In the RA group, a carotid shunt was selectively used for patients who exhibited negative results on the awake test. In contrast, such a shunt was used for all patients in the GA group. Results: There were no cases of postoperative stroke, cardiovascular events, or mortality. Nerve injuries were noted in 4 patients (3 in the RA group and 1 in the GA group), but they fully recovered prior to discharge. Operative time and clamp time were shorter in the RA group than in the GA group (119.29±27.71 min vs. 161.43±20.79 min, p<0.001; 30.57±6.80 min vs. 51.77±13.38 min, p<0.001, respectively). The hospital stay was shorter in the RA group than in the GA group (14.6±5.05 days vs. 18.97±8.92 days, p=0.022). None of the patients experienced a stroke or restenosis during the 27.23±20.3-month follow-up period. Conclusion: RA with a reliable awake test reduces shunt use and decreases the clamp and operative times of CEA, eventually resulting in a reduced length of hospital stay.
Lee, Yeong Ju;You, Hee Sang;Lee, Song Hee;Lee, So Lip;Lee, Han;Sung, Ho Joong;Kang, Hee Gyoo;Hyun, Sung Hee
Korean Journal of Clinical Laboratory Science
/
v.53
no.4
/
pp.326-332
/
2021
Swabs are useful and common sampling tools in various research fields, such as medicine, ecology, biotechnology, forensic medicine, and pollutant monitoring systems. Collection reagents are one of the essential components in sampling. It is important to develop a sample collection kit and designate an appropriate storage temperature because samples need to be stored for a long time. The purpose of this study was to identify the effects of three collection reagents and three storage temperatures on the recovery of living bacteria without media. We selected Escherichia coli and Staphylococcus aureus as representative environmental bacteria. Distilled water (DW), phosphate buffered saline (PBS), and Tris-EDTA (TE) buffer were used as collection reagents and stored at 22℃, 4℃, and -70℃ after sampling. The results of using each collection reagent and storage temperature on the bacteria were compared using relative light units (RLU) and the number of colony forming units (CFU). When using -70℃ storage temperature and the TE buffer, the number of living bacteria and the RLU values remained constant. It is therefore recommended that the sample be stored at -70℃ immediately after collection and a TE buffer solution be used as the collection reagent.
Kim, So Eun;Lee, Jae Baek;Jin, Young Ho;Yoon, Jae Chol;Jo, Si On;Jeong, Tae Oh
Journal of The Korean Society of Clinical Toxicology
/
v.17
no.1
/
pp.38-41
/
2019
Procalcitonin (PCT) is commonly employed in medical practice as a diagnostic biomarker of bacterial infection and also as a monitoring biomarker for antimicrobial therapy. There have been a few published reports concerning elevated PCT levels in people with acute liver injury caused by an overdose of acetaminophen. We report here on a case of PCT elevation in an adolescent with acute acetaminophen poisoning without any bacterial infection or liver injury. A 15-year-old girl had deliberately ingested 20 tablets of 650 mg acetaminophen (13 g) and she presented to our emergency department. The PCT level on admission was elevated to 65.64 ng/mL (reference range: 0-0.5 ng/mL). Her PCT level on the second day peaked up to 100 ng/mL and then it gradually decreased. There was no evidence of liver injury or infection on the computed tomography examination and other lab tests. The patient regained her good health and was discharged on the sixth day of hospitalization.
The increase in the need for a 24 hour monitoring of biological signals has been accompanied by an increasing interest in wearable systems that can register ECG at any time and place. ECG-monitoring clothing is a wearable system that records heart function continuously, but there have been difficulties in making accurate measurements due to motion artifacts. Although various factors may cause noise in measurements due to motion, the variations in the body surface and clothing during movements that cause eventual the shifting and displacement of the electrodes is particularly noteworthy. Therefore, this study used biomedical body mapping and a motion-capture system to measure and analyze the changes in the body surface and garment during movements. It was deduced that the area where the friction and separation between the garment and skin is the lowest would be the appropriate location to place the ECG electrodes. For this study, 5 male and 5 female in their 20s were selected as subjects, and through their selected body movements, the changes in the garment and skin were analyzed using the motion-capture system. As a result, the area below the chest circumference and the area below the shoulder blades were proposed as the optimal location of electrode for ECG monitoring.
Park, Young-Sang;Kwon, Oeon;Cho, Hyun-Sung;Son, Jaebum
Journal of Biomedical Engineering Research
/
v.41
no.1
/
pp.55-61
/
2020
Recently, there have been many research on fever management using u-healthcare technology. Especially, fever of infants requires continuous monitoring of body temperature by parents. For infants between 4 weeks and under 5 years old, it is recommended to use an electronic thermometer or chemical thermometer in the axilla, or to use an infrared thermometer. However, in order to overcome the reality of not being able to waste significant time on continuous monitoring, there have been demands of patch type thermometers with the internet of things (IoT) and wireless communication technologies. Existing IoT thermometers are difficult to attach to infants' body because they do not take into account its size, and their interoperability is not guaranteed because they do not comply with standards in communication. Therefore, in this study, a patch-type thermometer with a diameter of 20 mm and a weight of 2.9 g was developed to manage the fever of infants, while it communicates wirelessly with Bluetooth Low Energy (BLE) communication protocol and complies with IEEE 11073 PHD(Personal Health Device) at the same time. We verified its performance under the requirements of thermometers regulated by the Korean Ministry of Food and Drug Safety.
The CA(carbohydrate antigen)19-9 is complex protein that can be used as an important marker which aids the clinical diagnosis and prognosis of various pancreaticobiliary tumors. However, it was also reported that there were some CA19-9 positive patients with benign disease as using RIA method. The purpose of this study is to evaluate the clinical usefulness of serum level of CA19-9 with RIA(radioimmuno assay), CIA(chemiluminescence immuno assay), and conventional liver function tests. The correlation between CIA and RIA in CA19-9 of pancreatobiliary disease was 0.9833(P<0.01). Also, the correlations between CIA and RIA in CA19-9 of benign and malignant pancreaticobiliary tumor patients was 0.8714(P<0.01) and 0.9727(P<0.01) respectively. The correlation between CA19-9 and ALP was 0.5140(P<0.01) and CEA was 0.3385(P<0.05) as using CIA. The measurement of serum CA19-9 levels by CIA method may be useful in differentiating patients with malignant disease from those with benign disease in pancreaticobiliary tumors.
Journal of the Korean Society for Nondestructive Testing
/
v.25
no.4
/
pp.268-273
/
2005
The spirometer is a medical device that measures the instantaneous velocity of the respiratory gas flow capacity. It is used for testing the condition of the lung and patient monitoring. It measures the absolute capacity difference that includes the flow capacity signal. In this paper, by using an ultrasound sensor that reduce+ the error caused by the inertia and pressure it has improved the transmission and receiving signal. This has enabled patients with weak respiratory to use the spirometer. Also, by using the ARM 920T Processor, a precise and prompt detection system was implemented.
Yoon, Hee Nam;Hwang, Su Hwan;Jung, Da Woon;Lee, Yu Jin;Jeong, Do-Un;Park, Kwang Suk
Journal of Biomedical Engineering Research
/
v.35
no.6
/
pp.211-218
/
2014
The objective of this research is to develop an automatic algorithm based on electrocardiogram (ECG) to estimate slow-wave sleep (SWS). An algorithm is based on 7 indices extracted from heart rate on ECG which simultaneously recorded with standard full night polysomnography from 31 subjects. Those 7 indices were then applied to independent component analysis to extract a feature that discriminates SWS and other sleep stages. Overall Cohen's kappa, accuracy, sensitivity and specificity of the algorithm to detect 30s epochs of SWS were 0.52, 0.87, 0.70 and 0.90, respectively. The automatic SWS detection algorithm could be useful combining with existing REM and wake estimation technique on unattended home-based sleep monitoring.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.