• Title/Summary/Keyword: bio-ceramics

Search Result 37, Processing Time 0.024 seconds

Wet Foam Stability from Colloidal Suspension to Porous Ceramics: A Review

  • Kim, Ik Jin;Park, Jung Gyu;Han, Young Han;Kim, Suk Young;Shackelford, James F.
    • Journal of the Korean Ceramic Society
    • /
    • v.56 no.3
    • /
    • pp.211-232
    • /
    • 2019
  • Porous ceramics are promising materials for a number of functional and structural applications that include thermal insulation, filters, bio-scaffolds for tissue engineering, and preforms for composite fabrication. These applications take advantage of the special characteristics of porous ceramics, such as low thermal mass, low thermal conductivity, high surface area, controlled permeability, and low density. In this review, we emphasize the direct foaming method, a simple and versatile approach that allows the fabrication of porous ceramics with tailored microstructure, along with distinctive properties. The wet foam stability is achieved under the controlled addition of amphiphiles to the colloidal suspension, which induce in situ hydrophobization, allowing the wet foam to resist coarsening and Ostwald ripening upon drying and sintering. Different components, like contact angle, adsorption free energy, air content, bubble size, and Laplace pressure, play vital roles in the stabilization of the particle stabilized wet foam to the porous ceramics. The mechanical behavior of the load-displacements curves of sintered samples was investigated using Herzian indentations testes. From the collected results, we found that microporous structures with pore sizes from 30 ㎛ to 570 ㎛ and the porosity within the range from 70% to 85%.

Varistor Application of Cr-doped ZnO-Sb2O3 Ceramics (Cr을 첨가한 ZnO-Sb2O3 세라믹스의 바리스터 응용)

  • Hong, Youn-Woo;Shin, Hyo-Soon;Yeo, Dong-Hun;Kim, Jin-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.11
    • /
    • pp.854-858
    • /
    • 2010
  • In this study, we have investigated the effects of Cr dopant on the sintering and electrical properties of ZnO-$Sb_2O_3$ (ZS) ceramics for varistor application. Spinel phases including $\alpha-$ and $\beta$-type was formed at ZS system and $\alpha$-spinel was stabilized by Cr doping in ZS system. Densification of ZS and ZSCr system was retarded to $1000^{\circ}C$ by the formation of spinel at $800^{\circ}C$. The morphology and its distribution of spinel phases in ZS system was homogeneous but disturbed by Cr doping. In ZSCr the densification of ZnO compared with ZS system was more retarded by low concentration of Zn interstitial defects induced by Cr doping in addition to the effect of spinel phase formation. The defects in each system were identified as attractive coulombic center (ZS: 0.13 eV, ZSCr: 0.12 eV) and singly charged oxygen vacancy $V_0^{\cdot}$ (ZSCr: 0.33 eV). In all ZS and ZSCr system have week varistor behavior by the formation of double Schottky barrier at grain boundary but its stability of barrier was very sensitive to sintering temperature.

Piezoelectric properties of Pb-free BNKT ceramics with $MnO_2$ addition ($MnO_2$첨가에 따른 무연 BNKT계의 압전특성)

  • Lee, Mi-Young;Ryu, Sung-Lim;Yoo, Ju-Hyun;Lee, Su-Ho;Jeong, Yeong-Ho;Chung, Kwang-Hyun;Hong, Jae-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.744-747
    • /
    • 2004
  • [ $0.96[Bio_{0.5}(Na_{0.84}K_{0.16})_{0.5}TiO_3]+0.04SrTiO_3+0.3wt%Nb_2O_5+0.2wt%La_2O_3+xwt%MnO_2$ ], were studied in order to develope the superior dielectric and piezoelectric properties of Lead-free Piezoelectric ceramics. With increasing amount of $MnO_2$ addition, density showed the maximum value of $5.79[gcm^3$] at 0.1wt% $MnO_2$ addition, and electromechanical coupling factor($k_p$) and dielectric constant decreased, and mechanical quality factor($Q_m$) increased and showed the maximum value of 161 at 0.3wt% $MnO_2$ addition.

  • PDF

In Vitro Reaction for Calcium Phosphate Ceramics

  • Ioku, Koji;Toya, Hiroyuki;Fujimori, Hirotaka;Goto, Seishi
    • The Korean Journal of Ceramics
    • /
    • v.6 no.3
    • /
    • pp.214-218
    • /
    • 2000
  • Hydroxyapatite (HA) and $\beta$-tricalcium phosphate ($\beta$-TCP) are bio-compatible materials with bones and teeth. HA has been widely applied as bone substitutes because of chemical stability in vivo, while $\beta$-TCP has higher resorbability than HA when the material is implanted in a bone defect. In the present study, both HA and $\beta$-TCP porous ceramics were soaked in the simulated body fluid in order to investigate the reaction between the materials and the fluid. After the soaking test, carbonate hydroxyapatite was formed on HA surface at 1 week, and then the amount of precipitates increased with increasing period of the soaking test. While $\beta$-TCP was not dissolved in the fluid, carbonate hydroxyaopatite was also formed on $\beta$-TCP surface after 12 weeks, and the amount of precipitates was less than that on HA. In vitro behavior of HA was similar to that in vivo, but in vitro behavior of $\beta$-TCP was not similar to that in vivo.

  • PDF

Trends on development of new ceramics for automobile (자동차용 뉴세라믹스의 개발동향)

  • 김병호
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.9 no.4
    • /
    • pp.5-14
    • /
    • 1987
  • 세라믹스는 내열성, 고온강도, 내creep성, 내식성, 내마모성이 우수하며 경량이라는 점등, 금속재료 나 유기고분자재료와 비교화여 구조재료로서 이용하기 위한 많은 우수한 성질을 구비하고 있다. 따라서 세라믹스를 고효율 열기관, 정밀기계 가공부품, 생체재료(Bio-ceramics) 등의 신분야 즉, 금속재료나 유기고 분자재료로는 기대할 수 없는 가혹한 사용조건하에서 구조재료로의 이용이 기 대되고 있으며 엔진부품, 치골재료, seal재 등 일부에서는 실용화 되고 있기도 한다. 그러나 세 라맥스재료는, 강도는 실온에서도 금속재료에 필적하는 것이 얻어지고 있으나 인성(toughness)이 낮고 깨지기 쉬우며 안정성 및 신뢰성이 결핍되어 있어 사용상 큰 문제점으로 되어있다. 따라서 세계선진각국에서는 세라믹재료의 신뢰성을 높이기 위해 세라믹스의 고강도, 고인성화에 관한 연구가 활발히 진행되고 있다. 필자는 세라미엔진부품에 이용되고 있거나 가까운 장래에 이용이 가능한 각종 부품들에 대해 소개하고 세라믹엔진의 실용화를 위한 최근의 연구동향을 정리하여 소개하고자 한다.

  • PDF

Recent Developments in Synthesis of Colloidal Quantum Dots (콜로이드 양자점 합성의 다양한 연구 개발 동향)

  • Jung, Jae-Yong;Hong, Jong-Pal;Kim, Young-Kuk
    • Journal of Powder Materials
    • /
    • v.25 no.4
    • /
    • pp.346-354
    • /
    • 2018
  • Over the last decade, the study of the synthesis of semiconductor colloidal quantum dots has progressed at a tremendous rate. Colloidal quantum dots, which possess unique spectral-luminescent characteristics, are of great interest in the development of novel materials and devices, which are promising for use in various fields. Several studies have been carried out on hot injection synthesis methods. However, these methods have been found to be unsuitable for large-capacity synthesis. Therefore, this review paper introduces synthesis methods other than the hot injection synthesis method, to synthesize quantum dots with excellent optical properties, through continuous synthesis and large capacity synthesis. In addition, examples of the application of synthesized colloid quantum dots in displays, solar cells, and bio industries are provided.

A Study on the Preparation and Properties of Hydroxyapatite Bioceramics (Hydroxyapatite Bioceramics의 합성 및 물성에 관한 연구)

  • 이석곤;고형열;이구종;최상흘
    • Journal of the Korean Ceramic Society
    • /
    • v.26 no.2
    • /
    • pp.171-178
    • /
    • 1989
  • In order to develope hydroxyapatite ceramics which has mechanical strength as bio-implant materials and get the basic data for the study and application of biocompatibility, hydroxyapatite was synthesized at Ca/P=1.67~1.75, pH 7~11 by precipitation method. Using prepared powders, the sintered body, fluorine substituted body and the porous body was formed and their properties were investigated. The sample obtained in condition of Ca/P=1.67, pH 7 and sintering at 1,15$0^{\circ}C$ was decomposed to $\beta$-tricalcium phosphate, and co-existed with hydroxyapatite. Hydroxyapatite synthesized at pH 11 was not easily decomposed to $\beta$-tricalcium phosphate at sintering process. The substitution of a small amount of fluorine for hydroxyapatite prevented hydroxyapatite from being decompsed to $\beta$-tricalcium phosphate. Hydroxyapatite ceramics which substited of 10% fluorine was prepared at 1,15$0^{\circ}C$, and the valueof bending strength for this body were found to be 112MPa.

  • PDF

Ecotoxicity Assessment for Livestock Waste Water Treated by a Low Impact Development(LID) Pilot Plant (파일럿 규모의 LID공법을 적용한 축산폐수 처리수에 대한 생태독성 평가)

  • Park, Da Kyung;Chang, Soon-Woong;Choi, Hanna
    • Korean Journal of Environmental Biology
    • /
    • v.35 no.4
    • /
    • pp.662-669
    • /
    • 2017
  • This study evaluated the ecotoxicological properties of livestock waste water treated by a LID (Low Impact Development) system, using a mixture of bio-reeds and bio-ceramics as suitable bed media for a subsequent treatment process of a livestock wastewater treatment plant. The relationship between the pollutant reduction rate and the ecotoxicity was analyzed with the effluents from the inlet pilot plant, with vegetated swale and wetlands and the batch type of an infiltration trench. Each pilot plant consisted of a bio process using bio-reeds and bio-ceramics as bed media, as well as a general process using general reeds and a bed as a control group. The results indicated that, after applying the HRT 24 hour LID method, the ecotoxicity was considerably lowered and the batch type pilot plant was shown to be effective for toxicity reduction. The LID method is expected to be effective for water quality management, considering ecotoxicity by not only as a nonpoint source pollution abatement facility but also, as a subsequent treatment process linked with a livestock manure purification facility. It is necessary to take the LID technic optimization study further to apply it as a subsequent process for livestock wastewater treatment.

Cracking Behavior Under Contact Stress in Densely Coated Porous Engineering Ceramics (치밀층으로 코팅된 다공성 엔지니어링 세라믹스에서의 접촉응력에 의한 균열 거동)

  • Kim, Sang-Kyum;Kim, Tae-Woo;Kim, Do-Kyung;Lee, Kee-Sung
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.8 s.279
    • /
    • pp.554-560
    • /
    • 2005
  • The engineering ceramic needs the properties of high strength, hardness, corrosion-resistance and heat-resistance in order to withstand thermal shock or applied nonuniform stresses without failure. The densely coated porous ceramics can be used for machine component, electromagnetic component, bio-system component and energy-system component by their high-performances from superior coating properties and light-weight characteristics due to the structure including pore by itself. In this study we controlled the porosity of silica and alumina, $8.2\~25.4\%$ and $23.4\~36.0\%$, respectively, by the control of sintering temperature and starting powder size. We made bilayer structures, consisting of a transparent glass coating layer bonded to a thick substrate of different porous ceramics by a thin layer of epoxy adhesive, facilitated observations of crack initiation and propagation. The elastic modulus mismatch could be controlled using different porous ceramics as the substrate layer. Then we applied 150 N force using WC sphere with a radius of 3.18 mm by Hertzian indentation. As a result, the crack initiation in the coating layer was delayed at lower porosity in the substrate layer, and the damage in the coating layer was relatively smaller at the bilayer structure coated on higher elastic substrate.

Reconstruction of upper anterior by implant using customized zirconia abutment and all ceramics: a clinical report (맞춤형 지르코니아 지대주와 완전도재관을 이용한 상악 전치부 임플란트 보철 수복)

  • Kim, Ja-Yeong;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.81-92
    • /
    • 2014
  • It is so hard to obtain optimal anterior esthetics in the implant prosthesis. This is not only because of hard and soft tissue problem such as alveolar bone resorption and interdental papilla loss but also because of prosthetic limitation related to marginal exposure of metal abutment and metal ceramics and low transillumination. In this case, guided soft tissue healing is obtained using a long term provisional restoration with soft and hard tissue augmentation or immediate implantation. Then, this healed tissue is transferred to final master model using a customized impression coping and the implant is restored with a customized zirconia abutment and a all ceramics. This case presents satisfying result esthetically and functionally.