• Title/Summary/Keyword: bathroom

Search Result 397, Processing Time 0.03 seconds

Study on Convergence Technique through the Flow Analytical Study inside the Faucet for Bathroom (욕실수전 내부에서의 유동 해석 연구를 통한 융합 기술연구)

  • Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.2
    • /
    • pp.37-42
    • /
    • 2015
  • Nowadays, as the environmental pollution becomes severe on the earth, the water resource which can be used practically is dried up because of the natural disaster. And so, this is the time to be necessary to have the method for saving the water resource. This study investigates the distributions of velocity and temperature by the flow analysis inside the faucet models for bathroom. Model 3 has the most uniform distribution of temperature after mixing among all models. As model 3 has the smallest velocity distribution and the biggest space to mix by comparing the other models, it is seen to have the most influence on the discharged velocity of water and save the water. As the space of various configuration inside faucet model for bathroom is made by using the result of this study, it is thought to utilize at the development of this model in which more mixing becomes and the water can be saved. And it is possible to be grafted onto the convergence technique at design and show the esthetic sense.

A Study on the Surface Contamination Level and Spatial Dose Rate Measured from NM Patients-Only Bathroom (핵의학과 전용화장실에서 측정된 표면오염도 및 공간선량율에 대한 연구)

  • Moon, Jae-Seung;Jeong, Hyi-Il;Jeong, Hae-Seong;Sin, Min-Yong;Kim, Su-Geun;Park, Dae-Seong;Kim, Hyun-Ki;Kim, Hwa-San;Lee, Hyung-Nam;Ahn, Byeong-Pil;Lee, Dong-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.38-43
    • /
    • 2012
  • Purpose: Patients injected with FDG use the bathroom that Measured surface contamination level and spatial dose rate. This study about the effect that result affects workers in same part. Materials and Methods: Group1 is St. Vincent' s hospital's 60case. Group 2 is Bucheon St. Mary's hospital's 50case. Last case is lower the average daily number of patients than group 2. Measured time is 8:00, 10:00, 13:00, 15:00 and 17:00. Measured part is 4 point of toilet, basin and wastepaper basket, also measured accumulation dose of toilet during 3 month. Hospitals is installed PET/CT ware surveyed on presence of bathroom that used only by patient and worker has been using the bathroom. Results: The highest average surface contamination level of toilet is group1($8.38{\pm}4.56$), but the highest spatial dose rate is group3. Cumulative exposure dose measured by TLD during 3months is St.Vincent's hospital 0.78 mSv and Bucheon St.Mary's hospital 0.37 mSv. And result of survey is 16.12% worker using the bathroom. Conclusions: The more daily number of patient, the higher surface contamination level of bathroom. Especially, wastepaper basket's surface contamination level is exceed the reference value $4Bq/cm^2$. Based on This survey, Bathroom require special attention and proper decontamination.

  • PDF

Usage Pattern and User's Satisfaction with Village Community Center for Space Planning - Focused on 25 Village Community Centers in Hwasoon Province - (농촌 마을회관의 공간계획을 위한 이용실태 및 이용자 만족도에 관한 조사연구 - 전남 화순군 25개 마을회관을 중심으로 -)

  • Moon, In-Young;Kim, Mi-Hee
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.2
    • /
    • pp.193-200
    • /
    • 2014
  • This study aimed to evaluate how users are satisfied with village community center. It will develope and determine a most detailed design and requirements to maximizing for user's convenience. The study conducted interview survey using questionnaire based on universal design principles, to users of village centers that are in possible of cooperation of 25 village centers in Haw Soon district, Jeonnam province and used 160 cases to the analysis. The conclusion of this study is as follows. First, users showed most satisfaction about LDK space and dissatisfaction about design, stair/slope, entrance, and bathroom. Specially, users are dissatisfied with curtains at room and handralis at entrance. In terms of design, users about the indoor-outdoor environment as a whole was unsatisfactory. Second, survey on actual needs space scrutinized bathroom, kitchen, and stair/slope according to priority. In result of these surveys, user's satisfaction with village community center and actual needs space show needed improvements on bathroom and stair/slope space urgently.

Empirical Evaluation of Optimal User-Centered LED Lighting Environments in Residential Bathrooms

  • Lee, Jeongmin;Choi, Kyungah;Suk, Hyeon-Jeong
    • Science of Emotion and Sensibility
    • /
    • v.16 no.3
    • /
    • pp.305-310
    • /
    • 2013
  • This user-centered research aims to empirically evaluate color temperature (K) and illuminance (lx) of residential bathroom lightings to determine the most optimal lighting conditions for productive task performance as well as for satisfying users' emotional needs. Using 3 LED lighting fixtures, 4 types of lighting contexts were investigated; main lighting, task lighting, shower lighting, and bath lighting. Two lightings were installed parallel to the vertical edges of the main bathroom mirror to be used as main and task lighting, while another fixture was installed above the bathtub to be used for shower and bathing. For each lighting context, subjects (N=54) were instructed to perform a few tasks during which time the users were exposed to different lighting conditions with color temperature ranging from 2700 K ~ 6500 K and illuminance ranging from 100 lx ~ 700 lx. Upon completing the given tasks, subjects were asked to evaluate the lighting conditions and their applicability for performing the given tasks. Based on the user evaluations, the most optimal lighting conditions for the different lighting scenarios are as follow: 1) 3500 K ~ 4300 K and 150 lx for main lighting, 2) 3500 K ~ 4300 K and 500 lx ~ 700 lx for task lighting, and 3) 2700 K ~ 3500 K and 100 lx ~ 150 lx for shower/bath lighting. These results can be used to adjust the lighting standards suggested by KS, as well as be utilized by both engineers and designers in designing new types of user-centered bathroom lightings.

  • PDF

A study on the Process of Spatial Transfiguration for the Japanese-Western Eclectic Houses in Taegu province (대구지역 일.양절충식 주거의 공간 변화과정에 관한 연구)

  • 윤재웅
    • Journal of the Korean housing association
    • /
    • v.5 no.2
    • /
    • pp.15-28
    • /
    • 1994
  • This study is to analyze the transfiguration of the plan of the Japanese-Western eclectic houses in the process of the change in the living style and modernization. Twenty four Japanese-Western eclectic houses. which were located in Teagu Province and constructed during the period from the end of 19th century to the year 1945. were surveyed and analized about the original plans and the process of their spatial tranfituration. The results of this study are as follews 1) In the original plans. the bathroom, toilet and entrance hall in the residential space and HUSMA(wooden sliding doors) for separation of the rooms had been installed. 2) After the Liberation. the rooms of the residential space had been transfigured from TADAMI. JASHIKI. kitchen and toilet etc. to ONDOL. ANBANG. kitchen and toilet etc of the Korean traditional style. From 1980's they composed of living room, dining room and entrance hall of the Western-style. 3) From the liberation to 1960's. each room of residential space had been transtigured greatly form the Japanese style into the Korean style. Thus as the entrance hall. bathroom and TADAMI has been disappeared. DNDOL and MARU reappeared. Since 1980's bathroom diningroom and entrance hall ef the Western-style have recomposed in their residential space. But ANBANG is still used as a major living space in the surveyed houses.

  • PDF

The Survey on Residential Conditions and the Needs based on Universal Interior Design Features of the Elderly in U.S.A. - Focused on the Elderly Who Want to Age in Place in Columbia Missouri - (유니버설 디자인 관점에서 본 미국노인들의 주거실태 및 요구 - 미조리주 콜럼비아 재가노인들을 대상으로 -)

  • Park, Jung-A
    • Korean Journal of Human Ecology
    • /
    • v.19 no.6
    • /
    • pp.1127-1137
    • /
    • 2010
  • This study explored ways of changing a detached house which has older residents to a universal design home. This study investigated the residential conditions based on the universal design features and the need of universal design for aging in place. For this study, 153 residents who were living in single detached houses in Columbia, MO, were surveyed using written questionnaires and interviews. Primary findings of residential conditions were showed according to each spaces such as entrance, interior hallway, master bedroom, bathroom and kitchen. The major results are as follows: 1)It was confirmed that major spaces for daily living such as a bedroom, bathroom, kitchen and laundry facilities needed to be on the ground floor. 2)The most dangerous spaces in house were stairs to the upper or lower floors and the bathroom, 3)The need for modification based on universal design were high in order to facilitate aging in place. 4) Finally, elderly people in their seventies had especially strong needs through modification compared to the elderly people in their sixties who had plans to relocate.

A Study on the Mechanical Ventilation System of Bathroom in Apartment House (공동주택 화장실의 기계 환기시스템에 관한 연구)

  • 함진식
    • Journal of the Korean housing association
    • /
    • v.12 no.3
    • /
    • pp.141-148
    • /
    • 2001
  • To design mechanical ventilation for bathroom of apartment houses where air supply and exhaust are taken into consideration, mock-ups of ventilation systems, widely used in bathroom of apartment houses with an area of 100$\textrm{m}^2$, were made and installed in a laboratory. These ventilation mock-ups were available for control of air supply and exhaust, and the sizes of supply openings were 40cm${\times}$1cm, 40cm${\times}$3cm, and 40cm${\times}$5cm. They were installed at five positions, spaced 45cm at a height of 5cm from the floor. The exhaust fan was designed for its operating voltage to be set to five steps(100V, 130V, 150V, 180V and 220V) in order to control its air flow rates. When the size and position of each supply opening were changed with the wind velocity of the exhaust fan set to the step 5, the ventilation rates were measured and analyzed by the concentration decay method of tracer gas method, in order to present an efficient mechanical ventilation system. The results of the study revealed that the ventilations rates would increase in the presence of supply openings, compared to the absence of supply openings, and that the larger the size of the supply opening, the more the ventilation rates. Therefore, it was found necessary to take air supply into consideration.

  • PDF

A Study on Evaluation of Residential Environments and Residential Alterations for Physically Disabled Women (여성지체장애인 가정의 주택 개조 실태 및 거주자의 물리적 주거환경 평가에 관한 연구)

  • 최재순;권오정;이의정
    • Journal of the Korean Home Economics Association
    • /
    • v.39 no.11
    • /
    • pp.1-14
    • /
    • 2001
  • In order to develop a manual of residential alterations for the physically disabled, this case study was accomplished to analyze and evaluate residential environments and residential alterations for physically disabled women. Twenty-nine physically disabled women in Seoul and Kyunggi areas were the subjects of this study. With the evaluation checklist on physical environments of their housing, data on general characteristics of wall, floor, and all features and equipments and spaces of bedroom, kitchen, bathroom, living mom, entrance and balcony were gathered. Also, data on residential alterations were gathered through personal interviews. The data were collected from July 18th to July 25th in 2000. Frequency, percentage, and mean were used to analyze the data. In kitchen, small space, hee space under the sink and heights of the lower cabinets were not properly provided. In bathroom, door width, direction of opening door, adjustable height of shower, level difference, clear space for wheelchair user, and storage place were not appropriate to the disabled. Kitchen and bathroom showed high frequencies of alteration. But most of the subjects were not satisfied with the alterations of their housing. They also wanted to alter these two spaces in the future. In order to after their housing effectively appropriate information of the residential alterations was needed. If a guide or manual book for residential alterations was provided, the physically disabled people will more easily after their housing for safe and independent life.

  • PDF

An Experimental Study on the Noise Characteristics of Water Supply and Drain Installations Varied with Water Suppling Pressure in Apartment Bathroom (급수압 변화에 따른 대변기와 세면기의 급배수 소음 특성에 관한 실험적 연구)

  • Lee, Tai-Gang;Ko, Kwang-Pil;Choi, Eun-Suk;Kim, Hang;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.3 s.120
    • /
    • pp.226-234
    • /
    • 2007
  • This study aims to evaluate noise emission from water supply and drain installations in apartment bathroom. These noise were one of the most annoying noise sources in apartment houses. Especially, drain plumbing system have used bellow bathroom ceiling, it was very discomfort to hear the noise in bellow apartment. Noise of closets and faucets were measured which were main noise source, then these noise were evaluate and analyzed the emitting characteristics varying the supplying water pressure. As increasing the water pressure, also total noise level of the water supplying stool noise and faucet noise were increased. Especially the water closet showed remarkably the increasing noise level in middle and high frequency bandwidth, while the noise level of faucets increased in $50\;Hz{\sim}250\;Hz$ of low frequency bandwidth. Vortex closet were favorable to syphon closet, and lever faucet were favorable to conventional lavatory faucet on reducing the noise. Above these results could be used in basic data establishing KS (Korean Standard) for evaluation and rating procedure and measures reducing these noise.

Evaluation of the Adhesion Stability According to the Backfilling Area of the Tile back of the Bathroom of an Apartment House (공동주택 욕실의 타일배면 뒤채움 피착면적에 따른 부착안정성 평가)

  • Kim, Bum Soo;Song, Je Young;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.14-15
    • /
    • 2021
  • Recently, the size of tiles used for bathroom walls in apartment houses is gradually increasing in size. The problem is that when these large-sized tiles are attached by the sticking method, due to the nature of the method, there is a concern about the stability of the attachment to the part (pupil) where the tile and the adhesive are not attached. The problem is serious as it leads to lawsuits in the outbreak court. In addition, it is urgent to verify the adhesion stability of the sticking method because secondary damage occurs due to a safety accident caused by the falling of the tile. Ministry of Land, Infrastructure and Transport [Investigation of defects in apartment houses, calculation of repair cost and defect determination criteria] ① The tile adhesion strength is 0.39N/mm2 or more and ② It is specified to fill 80% or more of the base area of the tile backside, but this is currently trendy. It is considered that large-sized tiles need to be verified from multiple angles, and as part of that, we intend to verify the adhesion stability according to the area to be attached to large-sized tiles.

  • PDF