• Title/Summary/Keyword: base leakage

Search Result 161, Processing Time 0.025 seconds

Beamforming Optimization for Multiuser Two-Tier Networks

  • Jeong, Young-Min;Quek, Tony Q.S.;Shin, Hyun-Dong
    • Journal of Communications and Networks
    • /
    • v.13 no.4
    • /
    • pp.327-338
    • /
    • 2011
  • With the incitation to reduce power consumption and the aggressive reuse of spectral resources, there is an inevitable trend towards the deployment of small-cell networks by decomposing a traditional single-tier network into a multi-tier network with very high throughput per network area. However, this cell size reduction increases the complexity of network operation and the severity of cross-tier interference. In this paper, we consider a downlink two-tier network comprising of a multiple-antenna macrocell base station and a single femtocell access point, each serving multiples users with a single antenna. In this scenario, we treat the following beamforming optimization problems: i) Total transmit power minimization problem; ii) mean-square error balancing problem; and iii) interference power minimization problem. In the presence of perfect channel state information (CSI), we formulate the optimization algorithms in a centralized manner and determine the optimal beamformers using standard convex optimization techniques. In addition, we propose semi-decentralized algorithms to overcome the drawback of centralized design by introducing the signal-to-leakage plus noise ratio criteria. Taking into account imperfect CSI for both centralized and semi-decentralized approaches, we also propose robust algorithms tailored by the worst-case design to mitigate the effect of channel uncertainty. Finally, numerical results are presented to validate our proposed algorithms.

Self-Aligned $n^+$ -pPolysilicon-Silicon Junction Structure Using the Recess Oxidation (Recess 산화를 이용한 자기정렬 $n^+$ -p 폴리실리콘-실리콘 접합구조)

  • 이종호;박영준;이종덕;허창수
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.6
    • /
    • pp.38-48
    • /
    • 1993
  • A recessed n-p Juction diode with the self-aligned sturcture is proposed and fabricated by using the polysilicon as an n$^{+}$ diffusion source. The diode structure can be applicable to the emitter-base formation of high performance bipolar divice and the n$^{+}$ polysilicone mitter has an important effect on the device characteristics. The considered parameters for the polysilicon formation are the deposition condition. As$^{+}$ dose for the doping of the polysilicon and the annealing condition using RTP system. The vertical depth profiles of the fabricated diode are obtained by SIMS and the electrical characteristics are analyzed in terms of the ideality factor of diode (n), contact resistance and reverse leakage current. In addition, n$^{+}$-p junction diodes are formed by using the amorphous silicon (of combination of amorphous and polysiliocn) instead of polysilicon and their characteristics are compared with those of the standard sample. The As$^{+}$ dose for the formation of good junction is about 1~2${\times}10^{16}cm^{2}$ at given RTA conditions (1100.deg. C, 10sec).

  • PDF

The Effect of Acid Treatment Time for Ni Plating on the Joint of α-Al2O3 and Ni Metal (α-Al2O3와 Ni 금속 접합을 위한 Ni 무전해 도금시 산처리의 영향)

  • YI, EUNJEONG;AN, YONGTAE;CHOI, BYUNGHYUN;JI, MIJUNG;HWANG, HAEJIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.3
    • /
    • pp.306-310
    • /
    • 2016
  • In Na-base Battery for ESS, ${\alpha}-Al_2O_3$ and metal bonding was used to prevent direct reaction between electrolyte and electrode. The hard metal was metalized at $1600^{\circ}C$ in a flowing hydrogen gas for high bonding strength. In this study, instead of hard metal metalizing, Ni was plated on ${\alpha}-Al_2O_3$ by electroless Ni plating technique and then bonded with metal. To enhance the bonding strength, surface of ${\alpha}-Al_2O_3$ was treated with $H_3PO_4$. The effects of strength and leakage of joining as a function of acid treatment time on ${\alpha}-Al_2O_3$ are described.

Current Gain Enhancement in SiGe HBTs (SiGe HBT의 Current Gain특성 향상)

  • 송오성;이상돈;김득중
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.4
    • /
    • pp.367-370
    • /
    • 2004
  • We fabricated SiGe BiCMOS devices, which are important for ultra high speed RF IC chips, by employing $0.35\mu{m}$ CMOS process. To meet with the requirement of low noise level with linear base leakage current at low VBE region, we try to minimize polysilicon/ silicon interface traps by optimizing capping silicon thickness and EDR(emitter drive-in RTA) temperature. We employed $200\AA$and $300\AA$-thick capping silicon, and varied the EDR process condition at temperature of $900-1000^\circ{C}$, and time of 0-30 sec at a given capping silicon thickness. We investigated current gain behavior at each process condition. We suggest that optimum EDR process condition would be $975^\circ{C}$-30 sec with $300\AA$-thick capping silicon for proposed $0.35\mu{m}$-SiGe HBT devices.

  • PDF

Properties of Recessed Polysilicon/Silicon($n^{+}$) - Silicon(P) Junction with Process Condition (공정조건에 따른 함몰된 다결정실리콘/실리콘($n^{+}$) - 실리콘(p) 접합의 특성)

  • 이종호;최우성;박춘배;이종덕
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.05a
    • /
    • pp.152-153
    • /
    • 1994
  • A recessed $n^{+}$-p junction diode with the serf-aligned structure is proposed and fabricated by using the polysilicon as an $n^{+}$ diffusion source. The diode structure can be applicable to the emitter-base formation of high performance bipolar device and the $n^{+}$ polysilicon emitter has an important effect on the device characteristics. The considered parameters for the polysilicon formation are the deposition condition $As^{+}$ dose for the doping of the polysilicon, and the annealing using RTP system. The vertical depth profiles of the fabricated diode are obtained by SIMS. The eleotrical characteristics are analyzed in trims of the ideality factor of diode (n), contact resistance arid reverse leakage current. The $As_{+}$ dose for the formation of good junction is current. The $As^{+}$ dose for the formation of goodjunctions is about 1∼2${\times}$$10^{16}$$cm^{-2}$ at given RTA condition ($1100^{\circ}C$, 10 sec). The $n^{+}$-p structure is successfully applied to the self-aligned bipolar device adopting a single polysilicon technology.

  • PDF

Seismic fragility evaluation of the base-isolated nuclear power plant piping system using the failure criterion based on stress-strain

  • Kim, Sung-Wan;Jeon, Bub-Gyu;Hahm, Dae-Gi;Kim, Min-Kyu
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.561-572
    • /
    • 2019
  • In the design criterion for the nuclear power plant piping system, the limit state of the piping against an earthquake is assumed to be plastic collapse. The failure of a common piping system, however, means the leakage caused by the cracks. Therefore, for the seismic fragility analysis of a nuclear power plant, a method capable of quantitatively expressing the failure of an actual piping system is required. In this study, it was conducted to propose a quantitative failure criterion for piping system, which is required for the seismic fragility analysis of nuclear power plants against critical accidents. The in-plane cyclic loading test was conducted to propose a quantitative failure criterion for steel pipe elbows in the nuclear power plant piping system. Nonlinear analysis was conducted using a finite element model, and the results were compared with the test results to verify the effectiveness of the finite element model. The collapse load point derived from the experiment and analysis results and the damage index based on the stress-strain relationship were defined as failure criteria, and seismic fragility analysis was conducted for the piping system of the BNL (Brookhaven National Laboratory) - NRC (Nuclear Regulatory Commission) benchmark model.

Clinical Analysis and Surgical Results of Skull Base Meningiomas (뇌기저부 수막종의 임상분석 및 수술성적)

  • Kim, Young Wook;Jung, Shin;Kim, Jae Sung;Lee, Jung Kil;Kim, Tae Sun;Kim, Jae Hyoo;Kim, Soo Han;Kang, Sam Suk;Lee, Je Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.11
    • /
    • pp.1437-1444
    • /
    • 2000
  • Objectives : Traditionally intracranial meningiomas are regarded as benign and curable tumors. About half of all intracranial meningiomas locate in the skull base region. However, surgical removal of these tumors may be challenging and require special considerations. Here general aspects of skull base meningiomas including clinical presentation, surgical approaches, complications and their recurrence rate are discussed based on our experiences. Methods : A retrospective analysis of 61 consecutive patients with skull base meningioma among 210 patients of meningioma between 1989 and 1998 were done. Results : There were 41 women and 20 men ranging from 13 to 74 years(mean 52 years). These tumors were divided into seven categories according to location : olfactory groove(n=9), sphenoid ridge(n=16), cavernous sinus(n =2), tuberculum sellae(n=8), tentorium(n=13), cerebellopontine angle(n=12), and foramen magnum meningiomas (n=1). Surgical approaches were selected on the basis of the tumor attachment, size and extension on preoperative radiologic findings. Total removal(Simpson grade I and II) was achieved in 50 cases(82%), and subtotal removal (Simpson grade III) in 11 patients(18%). According to WHO classification, there were 52 of cases of benign meningioma( 86%), 6 atypical cases(10%), and 3 malignant cases(5%). The most common postoperative complications were CSF leakage(23.0%) and cranial nerve injury(8.2%). Three patient died related with tumor(one was due to surgical complication and the other two due to recurrence) but three patients died from other systemic causes. Mean follow-up period was 51.7 months after surgery. Recurrence occurred in six patients(10.9%) ; three with tentorial meningioma, two with sphenoid ridge, and one in cerebellopontine angle. Conclusion : With advances in neuroradiology and microsurgical techniques, the surgical outcome of miningiomas has been markedly improved with acceptable morbidity and mortality rates. Overall, our surgical results of skull base meningiomas is comparable to other reports. Therefore, with the appropriate operative strategy and techniques, these tumors can be completely removed and good surgical results can be expected.

  • PDF

INFLUENCES OF DRY METHODS OF RETROCAVITY ON THE APICAL SEAL (치근단 역충전와동의 건조방법이 폐쇄성에 미치는 영향)

  • Lee, Jung-Tae;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.166-179
    • /
    • 1999
  • Apical sealing is essential for the success of surgical endodontic treatment. Root-end cavity is apt to be contaminated with moisture or blood, and is not always easy to be dried completely. The purpose of this study was to evaluate the influence of dry methods of retrocavity on the apical seal in endodontic surgery. Apical seal was investigated through the evaluation of apical leakage and adaptation of filling material over the cavity wall. To investigate the influence of various dry methods on the apical leakage, 125 palatal roots of extracted human maxillary molar teeth were used. The clinical crown of each tooth was removed at 10 mm from the root apex using a slow-speed diamond saw and water spray. Root canals of the all the specimens were prepared with step-back technique and filled with gutta-percha by lateral condensation method. After removing of the coronal 2 mm of filling material, the access cavities were closed with Cavit$^{(R)}$. Two coats of nail polish were applied to the external surface of each root. Apical three millimeters of each root was resected perpendicular to the long axis of the root with a diamond saw. Class I retrograde cavities were prepared with ultrasonic instruments. Retrocavities were washed with physiologic saline solution and dried with various methods or contaminated with human blood. Retrocavities were filled either with IRM, Super EBA or composite resin. All the specimens were immersed in 2% methylene blue solution for 7 days in an incubator at $37^{\circ}C$. The teeth were dissolved in 14 ml of 35% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data were analysed statistically using one-way ANOVA and Duncan's Multiple Range Test. To evaluate the influence of various dry methods on the adaptation of filling material over the cavity wall, 12 palatal roots of extracted human maxillary molar teeth were used. After all the roots were prepared and filled, and retrograde cavities were made and filled as above, roots were sectioned longitudinally. Filling-dentin interface of cut surfaces were examined by scanning electron microscope. The results were as follows: 1. Cavities dried with paper point or compressed air showed less leakage than those dried with cotton pellet in Super EBA filled cavity (p<0.05). However, there was no difference between paper point- and compressed air-dried cavities. 2. When cavities were dried with compressed air, dentin-bonded composite resin-filled cavities showed less apical leakage than IRM- or Super EBA-filled ones (p<0.05). 3. Regardless of the filling material, cavities contaminated with human blood showed significantly more apical leakage than those dried with compressed air after saline irrigation (p<0.05). 4. Outer half of the cavity showed larger dentin-filling interface gap than inner half did when cavities were filled with IRM or Super EBA. 5. In all the filling material groups, cavities contaminated with blood or dried with cotton pellets only showed larger defects at the base of the cavity than ones dried with paper points or compressed air.

  • PDF

Dual-Band Feedforward Linear Power Amplifier Using Equal Group Delay Signal Canceller (동일 군속도 지연 상쇄기를 이용한 이중 대역 Feedforward 선형 전력 증폭기)

  • Choi, Heung-Jae;Jeong, Yong-Chae;Kim, Hong-Gi;Kim, Chul-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.7
    • /
    • pp.839-846
    • /
    • 2007
  • In this paper, the first attempt to design a novel structure of dual-band feedforward linear power amplifier(FFW LPA) was presented. Up to now, primary technical difficulty has been the extension of the conventional signal canceller to the dual-band operation. Therefore, we propose the design technique of the dual-band equal group delayed carrier canceller, the dual-band equal group delayed intermodulation distortion(IMD) canceller and the dual-band FFW LPA. The operation frequency bands of the implemented dual-band FFW LPA are digital cellular($f_0=880$ MHz) and IMT-2000($f_0=2.14$ GHz) band, which are separated about 1.26 GHz. With the high power amplifier of 120 W PEP for commercial base-station application, IMD cancellation loop shows 20.45 dB and 25.04 dB loop suppression at each band of operation for 100 MHz. From the adjacent channel leakage ratio(ACLR) measurement with CDMA IS-95A 4FA and WCDMA 4FA signal, we obtained 16.52 dB improvement at the average output power of 41.5 dBm for digital cellular band, and 18.59 dB improvement at the average output power of 40 dBm for IMT-2000 band simultaneously.

THE EFFECT OF INTRACANAL BASE TO PROTECT THE CERVICAL LEAKAGE OF BLEACHING AGENTS (표백제의 치경부 누출을 방지하기 위한 근관 내 이장재의 효과)

  • Kwon, Su-Mi;Hwang, Su-Jin;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.144-152
    • /
    • 2000
  • Intracoronal bleaching is currently disregarded by many clinicians because of the potential consequence of cervical resorption. To prevent this complication it is recommended that intra coronal barrier materials be placed over the root canal obturation and sodium perborate be used with water rather than with hydrogen peroxide. The purpose of this study was to evaluate the amount of the hydrogen peroxide penetration according to the difference in intracanal base materials and sodium perborate preparation. Fifty extracted intact premolars were instrumented, and filled with gutta-percha. And then the outer surface of the teeth was sealed with wax exposing the CEJ. The prepared teeth were placed in plastic tubes containing 1.5ml distilled water with their entire root submerged into the solution, The teeth were divided into the following five groups. In the first two groups gutta-percha was removed without placement of barrier, and then water or superoxole(30% $H_2O_2$) with sodium perborate were used respectively for bleaching. In the other three groups, after removal of gutta-percha, an intracanal isolating barrier(ZPC, IRM, Fuji II LC) was placed and then bleached with sodium perborate and superoxole. The bleaching procedure was performed 4 times with 1 week interval. The results were as follows : 1. All the groups showed a tendency of increasing penetration amount with increasing treatment times(P<0.05). 2. After the 1st and 2nd treatments, there was no significant difference in microleakage among the groups. 3. After the 3rd bleaching with superoxole and sodium perborate, there was no significant difference in microleakage between gutta-percha alone group and gutta-percha with ZPC, Fuji II LC barrier group. But significant difference was found between IRM barrier group and other groups(P<0.01). 4. After the 4th bleaching with superoxole and sodium perborate, there was no significant difference between gutta-percha alone group and gutta-percha with barrier groups. 5. After the 4th treatment, the group bleached with sodium perborate and water without barrier showed lower hydrogen peroxide penetration than that of other groups(P<0.01).

  • PDF