• Title/Summary/Keyword: base Isolation

Search Result 486, Processing Time 0.026 seconds

Isolation and Characterization of Major Glycosphingolipid from Rice Bran Extract (쌀겨 추출물로부터 스핑고당지질의 분리와 구조결정)

  • Mitsutake, Susumu;Okada, Tadashi;Kang, Byoung-Won
    • Applied Biological Chemistry
    • /
    • v.50 no.1
    • /
    • pp.72-76
    • /
    • 2007
  • In order to examine the biofunctions of glycosylceramide which is representative of sphingolipid, monoglycosylceramide (cerebroside) was isolated from rice bran extract. Crude glycosylceramides were isolated in large quantities and promptly by flash system column chromatography from rice bran extract, and purified by normal-phase HPLC using an evaporative light-scattering detector. One major cerebroside was obtained by HPLC used as an eluent consisting of chloroform, methanol and water (99:11:1, v/v/v), and the constituents were analyzed by MALDI/TOF-MS, FAB-MS, GC and 600 MHz $^1$H-NMR. The component sugar was estimated to be glucose. In the ceramide, the fatty acid component consist was 2-hydroxy arachidic acid. The long-chain base component was sphinga-4,8-dienine.

A Study on Dynamic Characteristics of Rotating Transmission Using PD Control (PD 제어기를 이용한 회전전동장치의 동특성에 관한 연구)

  • Kim J.K.;Kim J.T.;Kim T.H.;Oh T.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.715-720
    • /
    • 2005
  • The rotating transmission is made up of belts, mass disks and gears. This precise piece of equipment is controlled electro-mechanically by the mote. and operation program. The control strategy and the transmission can be changed by belts' stiffness and change of the mass and gear. This transmission can be modeled as a rigid body, and also finds broad application in such diverse fields as machine tools, the cruise control system in automobiles, and control in the attitude and gimbals of spacecraft. The study of the rotating transmission excited by its base motion is not only able to predict the rotational performance, but obtain the fundamental data for vibration isolation. In this thesis, we studied the response abilities such as steady overshoot, undershoot and ect. and the response velocities such as rising time, settling time, and ect. in the rotating transmission through PD control experiment.

  • PDF

Evaluation of Floor Impact Sound Performance according to the installation of Ceiling and Wall (천장 및 벽구성 방법에 따른 바닥충격음 특성평가)

  • Kim, Kyoung-Woo;Choi, Hyun-Jung;Yang, Kwan-Seop;Lee, Seung-Eon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.261-264
    • /
    • 2004
  • Impact sounds, such as those created by footsteps, the dropping of an object or the moving of furniture, can be a source of great annoyance in residential buildings. The character and level of impact noise generated depends on the object striking the floor, on the basic structure of the floor, and on the floor covering. This study base on the evaluate of isolation performance of impact sound according to the installation of ceiling and wall. In this test, we measured the reduction of impact sound in the case of inserting absorption materials, increasing of the thickness of air layer and using anti-vibration rubber in ceiling, install of absorption materials in wall. The results of this study show that treatment of ceiling and wall have some reduction of the light weight impact sound and heavy weight impact sound.

  • PDF

Seismic Response of Arch Structure with Base Isolation Device Depending on Installation Angle (면진장치 설치각도에 따른 아치구조물의 지진응답)

  • Kim, Gee-Cheol;Lee, Joon-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.1
    • /
    • pp.25-32
    • /
    • 2022
  • The seismic behaviors of the arch structure vary according to the rise-span ratio of the arch structure. In this study, the rise-span ratio (H/L) of the example arch structure was set to 1/4, 1/6, and 1/8. And the installation angle of the seismic isolator was set to 15°, 30°, 45°, 60° and 90°. The installation angles of the seismic isolator were set by analyzing the horizontal and vertical reaction forces according to the rise-span ratio of the arch structure. Due to the geometrical and dynamic characteristics of the arch structure, the lower the rise-span ratio, the greater the horizontal reaction force of the static load, but the smaller the horizontal reaction force of the dynamic load. And if the seismic isolator is installed in the direction of the resultant force of the reaction forces caused by the seismic load, the horizontal seismic response becomes small. Also, as the installation angle of the seismic isolator increases, the hysteresis behavior of the seismic isolator shows a plastic behavior, and residual deformation appears even after the seismic load is removed. In the design of seismic isolators for seismic response control of large space structures such as arch structures, horizontal and vertical reaction forces should be considered.

First Report of Soft Rot Induced by Dickeya dadantii on Euphorbia hypogaea in Korea

  • Ismaila Yakubu;Ji Ho Song;Yun Ju Lee;Min A Son;Su Hyeon Han;Hyun Gi Kong
    • Research in Plant Disease
    • /
    • v.30 no.1
    • /
    • pp.95-98
    • /
    • 2024
  • In a survey conducted in March 2023, Euphorbia hypogaea plants cultivated within greenhouses in Yongin, Korea exhibited water-soaked areas near the stem base, close to the soil. Subsequent isolation from diseased E. hypogaea led to the identification of a bacterial strain, designated as CBNUMPBL-103. The isolate was identified as Dickeya dadantii through sequencing of the 16s rRNA and phylogenetic analysis. The pathogenicity of the isolate was confirmed by inoculating it into healthy E. hypogaea, resulting in the manifestation of similar symptoms observed during the survey. The re-isolated strain recovered from inoculated plants showed a similar morphology with the inoculated strain. This is the first documentation of D. dadantii causing soft rot of E. hypogaea in Korea.

Isolation and Characterization of Zymomonas mobilis DNA Fragments Showing Promoter Activity in Escherichia coli (Escherichia coli에서 Promoter 활성을 보이는 Zymomonas mobilis DNA 조각의 분리와 분석)

  • Kim, Eun-Joon;Yoon, Ki-Hong;M.Y. Pack
    • Microbiology and Biotechnology Letters
    • /
    • v.17 no.6
    • /
    • pp.600-605
    • /
    • 1989
  • For the purpose of isolation of the Zymomonas mobilis DNA fragments showing promoter activity in Escherichia coli, a promoter screening vector, PCMT215 was constructed by transferring a promoterless chloramphenicol acetyltransferase (CAT) gene of pYEJ001 into pMT21 which contains $\beta$-lactamase gene and multiple cloning sites. A library of Z, mobilis Sau3AI DNA fragments was constructed in E. coli using the newly constructed pCMT215. Fourteen clones showing resistance to chloramphenicol ranging in concentration from 30 to 750 $\mu$g/$m\ell$ were selected. From five clones of them, the Z. mobilis DNA fragments expressing CAT gene of the recombinant plasmids were sequenced and then sites of transcriptional initiation were identified. The nucleotide sequences of the cloned DNA shared AT rich regions, poly A's or T's stretches and palindromic regions. The positions of transcriptional initiation for CAT gene occurred at more than one site spaced over by 4 to 190 base pairs on the cloned fragments in E. coli.

  • PDF

Evaluation of Site-Specific Seismic Amplification Characteristics in Plains of Seoul Metropolitan Area (서울 평야 지역에 대한 부지 고유의 지진 증폭 특성 평가)

  • Sun, Chang-Guk;Yang, Dae-Sung;Chung, Choong-Ki
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.4 s.44
    • /
    • pp.29-42
    • /
    • 2005
  • Total 350 borehole profiles were selected from the database of borehole logs in Seoul, for the site-specific seismic evaluation at two 4km${\times}$4km plain areas. Equivalent-linear site response analyses for the selected 350 sites were conducted based on shear wave velocity (Vs) Profiles, which were determined from the N-Vs correlation established using borehole seismic testing results in the inland areas of Korea. Most sites were categorized as site classes C and D based on the mean Vs to 30 m in depth (Vs30) ranging from 250 to 550 m/s. The she periods of the plains in Seoul ranging between 0.1 and 0.4 sec were significantly lower than those of the western US, from which the site coefficients in Korea were derived. For plains in Seoul, the site coefficients, Fa's and Fv's specified in the Korean seismic design guide, underestimate the ground motion in short-period (0.1-0.5 sec) band and overestimate the ground motion in mid-period (0.4-2.0 sec) band, respectively, because ol the differences in the geotechnical conditions between Seoul and the western US, although the Fa's in several sites overestimate the motion due to the base Isolation effect resulted from the soft layer in soil deposit.

Improvement of Insulation System for LNG Storage Tank Base Slab (LNG 저장탱크 바닥판 단열 시스템 개선)

  • Lee, Yong-Jin;Lho, Byeong-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.141-147
    • /
    • 2010
  • Liquefied natural gas(LNG) is natural gas that has been converted temporarily to liquid form for ease of storage and transport it. Natural gas is the worlds cleanest burning fossil fuel and it has emerged as the environmentally preferred fuel of choice. In Korea, the demand of this has been increased since the first import from the Indonesia in 1986. LNG takes up about 1/600th the volume of natural gas in the gaseous state by cooling it to approximately $-162^{\circ}C(-260^{\circ}F)$. The reduction in volume therefore makes it much more cost efficient to transport and store it. Modern LNG storage tanks are typically the full containment type, which is a double-wall construction with reinforced concrete outer wall and a high-nickel steel inner tank, with extremely efficient insulation between the walls. The insulation will be installed to LNG outer tank for the isolation of cryogenic temperature. The insulation will be installed in the base slab, wall and at the roof. According to the insulation's arrangement, the different aspects of temperature transmission is shown around the outer tank. As the result of the thermal & stress analysis, by the installing cellular glass underneath the perlite concrete, the temperature difference is greatly reduced between the ambient temperature and inside of concrete wall, also reducing section force according to temperature load.

Comparison of Quantitative Relationship between Real-Time PCR and Acid Fast Bacilli Staining for Diagnosis of Pulmonary Tuberculosis (폐결핵 진단을 위한 실시간중합효소연쇄반응과 AFB 염색진단검사의 정량적 연관성 비교)

  • Jung, Taewon;Kim, Sang-Ha;Kim, Sunghyun;Choi, Jae-Sun;Kim, Young-Kwon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.4
    • /
    • pp.335-341
    • /
    • 2020
  • This study investigates the association of the AFB stain with the cycle threshold (Ct) value of the Cobas TaqMan MTB test (CTM test, Roche Diagnostics, Basel, Switzerland), and it establishes the base data for semi-quantitative identification of M. tuberculosis by the Ct value. CTM test were simultaneously conducted on 8,389 specimens submitted to the Samsung Medical Center from January 2015 to December 2015, and the results were analyzed and compared retrospectively investigates the association of the AFB stain with the Ct value of the CTM test, and it establishes the base data for semi-quantitative identification of M. tuberculosis by the Ct value. The Ct values for 135 positive specimens of the CTM were inversely correlated with the AFB stain (rs=-0.545, P<0.01). When the Ct value of the CTM test and the time to positivity (TTP) of the mycobacteria cultures were verified based on the AFB stain, they were found to have a positive correlation (rs=0.136, P<0.01). The negative correlation between the CTM test and the AFB stain grade was demonstrated. The clinical significance was verified by applying these criteria to the clinical results. The semi-quantitative criteria of this study can be used to facilitate the rapid isolation of patients with active tuberculosis and infection control in the hospital.

Isolation and Characterization of PERV-C env from Domestic Pig in Korea

  • Park, Sung-Han;Bae, Eun-Hye;Park, Sang-Min;Park, Jin-Woo;Lim, Mi-Suk;Jung, Yong-Tae
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.10
    • /
    • pp.1735-1740
    • /
    • 2008
  • Clone PERV-C (A3) env was isolated from the genomic DNA of domestic pig (Sus scrofa domesticus) in Korea to investigate the molecular properties of PERV-C. The nucleic acid homologies between the PERV-MSL (type C) reference and the PERV-C(A3) clone was 99% for env, but a single base pair deletion was found in the transmembrane (TM) region of the env open reading frame. To examine the functional characteristics of truncated PERV-C env, we constructed a replication-incompetent retroviral vector by replacing the env gene of the pCL-Eco retrovirus vector with PERV-C env. A retroviral vector bearing PERV-C/A chimeric envelopes was also created to complement the TM defect. Our results indicated that truncated PERV-C env was not infectious in human cells as expected. Interestingly, however, the vector with the PERV-C/A envelope was able to infect 293 cells. This observation suggests that recombination within PERV-C TM could render PERV-C infectious in humans. To further characterize PERV-C/A envelopes, we constructed an infectious molecular clone by using a PCR-based technique. This infectious molecular clone will be useful to examine more specific regions that are critical for human cell tropism.