• Title/Summary/Keyword: auto ignition

Search Result 147, Processing Time 0.023 seconds

Measurement and Prediction of Combustion Properties of Styrene (스티렌의 연소특성치 측정 및 예측)

  • Ha, Dong-Myeong;Na, Byeong-Gyun
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.4
    • /
    • pp.70-76
    • /
    • 2013
  • For the safe handling of styrene, this study was investigated the explosion limits of styrene in the reference data. The flash points and AITs(auto-ignition temperatures) by ignition delay time were experimented. As a results, the lower and upper explosion limits of styrene recommended 0.9 Vol.% and 8.0 Vol.%, respectively. The lower flash points of styrene by using closed-cup tester were experimented $29^{\circ}C{\sim}31^{\circ}C$. The lower flash points of styrene by using open cup tester were experimented $32^{\circ}C{\sim}36^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for styrene. The experimental AIT of styrene was $460^{\circ}C$.

Application of Water Mist System for a Power Transformer Room -Cooling Characteristics (Part 2) (변압기실 화재에 대한 미분무수 소화시스템의 적용 -냉각특성을 중심으로(Part 2))

  • Choi Byung-Il;Han Yong-Shik;Kim Myung-Bae
    • Fire Science and Engineering
    • /
    • v.19 no.4 s.60
    • /
    • pp.37-41
    • /
    • 2005
  • The present study describes the cooling performance of two kinds of water mist systems used in fire extinguishment. The cooling is necessary for the prevention of an auto re-ignition of the power transformer. A heat source for such the re-ignition is the accumulated thermal energy in the dielectric oil from the transformer core. Because of the weight of the real core, reduced-scale experiments are carried out. A similarity analysis Is also performed to determine the discharge time of the water mist systems from the experimental results. The discharge time to prevent the re-ignition in the real-scale transformer is estimated about 12 hour from the similarity analysis of the reduced-scale experiments.

A Study on Estimation of Lower Explosive Limits of Alcohol Compounds (알코올화합물의 폭발하한계 추산에 관한 연구)

  • Dong-Myeong Ha;Yong-Chan Choi;Haejin Oh;Su-kyung Lee
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2002.11a
    • /
    • pp.291-296
    • /
    • 2002
  • Flammable compounds are indispensible in domestic as well as in industrial fields as fuel, solvent and raw materials. The fire and explosion properties necessary for safe storage, transport, process design and operation of handling flammable substances are lower explosive limits(LEL), upper explosive limits(UEL), flash point, fire point, AIT(auto ignition temperature), MIE(minimum ignition energy), MOC(minimum oxygen concentration) and heats of combustion.

  • PDF

The Development of Automatic Correction Algorithm for the Knocking Threshold in Spark Ignition Engine (스파크 점화기관에서의 노킹판단 기준값의 자동수정 알고리즘 개발)

  • 강성현;장광수;서정인;전광민
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.7
    • /
    • pp.32-41
    • /
    • 1999
  • In this study, a new knocking control algorithm was developed using the knock threshold value auto-correction algorithm. This algorithm uses the Fast Fourier Transform9FFT) method by measuring cylinder block vibration signals of a 1498 cc four-cylinder spark ignition engine. The experimental results show the proposed knock control algorithm provides improved performance compared to existing methods. The results also show that the proposed FFT algorithm provides real-time adjustment of the knock threshold value.

  • PDF

Chemical Mechanism Reduction and Validation of Methyl Butanoate by Automatic Reduction Procedure (Methyl Butanoate의 상세 화학 반응 메커니즘 자동 축소화를 통한 기초 반응 메커니즘의 생성 및 검증)

  • Lee, Youngjae;Huh, Kang Y.
    • Journal of the Korean Society of Combustion
    • /
    • v.21 no.3
    • /
    • pp.16-23
    • /
    • 2016
  • In this study, skeletal mechanisms are produced by directed relation graph with specified threshold value and sensitivity analysis based on species database from the directed relation graph. Skeletal mechanism is optimized through the elimination of unimportant reaction steps by computational singular perturbation importance index. Reduction is performed for the detailed mechanism of methyl butanoate consisting of 264 species and 1219 elementary reactions. Validation shows acceptable agreement for auto-ignition delays in wide parametric ranges of pressure, temperature and equivalence ratio. Methyl butanoate has been proposed as a simple biodiesel surrogate although the alkyl chain consists of four carbon atoms. The resulting surrogate mechanism for n-heptane and MB consists of 76 species and 226 reaction steps including those for NOx.

TRANSIENT FLAMELET MODELING FOR COMBUSTION PROCESSES OF HSDI DIESEL ENGINES

  • Kim, H.J.;Kang, S.M.;Kim, Y.M.;Lee, J.H.;Lee, J.K.
    • International Journal of Automotive Technology
    • /
    • v.7 no.2
    • /
    • pp.129-137
    • /
    • 2006
  • The representative interactive flamelet(RIF) concept has been applied to numerically simulate the combustion processes and pollutant formation in the HSDI diesel engine. In order to account for the spatial inhomogeneity of the scalar dissipation rate, the eulerian particle flamelet model using the multiple flamelets has been employed. The vaporization effects on turbulence-chemistry interaction are included in the present RIF procedure. the results of numerical modeling using the rif concept are compared with experimental data and with numerical results of the widely-used ad-hoc combustion model. Numerical results indicate that the rif approach including the vaporization effect on turbulent spray combustion process successfully predicts the ignition delay characteristics as well as the pollutant formation in the HSDI diesel engines.

Thermal Stability and Critical Ignition Temperature of RPF (RPF의 열적 안정성과 한계발화온도)

  • Lim, Woo-Sub;Choi, Jae-Wook
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.99-104
    • /
    • 2008
  • It is important to understand thermal characteristic as a method to estimate the new materials, because spontaneous ignition characterized by causing combustion in the low temperature without ignition source. If can not find out the thermal characteristics of materials, it is frequent that causes of fires could not be found. The danger level of spontaneous ignition material should be estimated and by closely studying its thermal characteristic. However, RPF(Refuse Paper & Plastic Fuel) is a solid matter and getting increasesa year by year because it is an economy profit as alternative energy for limited fossil fuels. Some time RPF occur a fire in the cases of its production process and conservation. Therefore study for thermal stability and critical ignition temperature of RPF was so imperative that the experiment by means of Bombe Calorimeter, TG-DTA, MS80, SIT-II, and Wire Basket Test was implemented. As a result, RPF had a caloric value 26.4-28.3 MJ/kg, and its initial pyrolysis temperature was $192^{\circ}C$ at heating rate 2 K/min. With the result of analysis by MS 80 which is an instrument measuring microscopic calory, pure RPF not containing water has higher caloric value than RPF containing 20% water. Also, SIT-II which is an instrument of insulated auto-ignition was ignited by $118.5^{\circ}C$. This temperature is lower than that of Wire Basket Test. The critical ignition temperature was calculated by Frank-Kamenetskii equation can cause ignition at $80^{\circ}C$ when conserved in the height of 10 m by the standard of infinity slab.

노말프로판올의 자연발화온도와 발화지연시간의 관계

  • 하동명;최용찬;한종근;김한돌;신용범;정세훈;이문선;윤준혁;류정열
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2003.10a
    • /
    • pp.154-159
    • /
    • 2003
  • 화학공장과 제조업 등의 사업장에서 발생하는 화재 및 폭발은 설비와 건물의 파괴뿐만 아니라 사업장의 근로자와 인근 주민에 대한 인명 피해까지 초래하는 경우가 많으므로 공정 안전을 위해 화재 및 폭발 분야의 연구에 많은 관심을 가져야 한다. 방화(Fire Protection) 및 방폭(Fire Protection)에 관련되는 특성치로 MSDS의 5번째 항목인 폭발화재시대처방법(Fire-fighting Measures)에서는 폭발(연소)한계(Explosive Limit 혹은 Flammability Limit), 인화점(Flash Point), 최소발화온도(AIT: Auto-ignition Temperature)가 제시되고 있다.(중략)

  • PDF

Professional Engineer Yard: Understanding of Engine Variable Valve Train Technology and Trend (기술사마당: 엔진 가변 밸브 기구 이해 및 개발동향)

  • Kim, Do-Wan
    • Journal of the Korean Professional Engineers Association
    • /
    • v.44 no.4
    • /
    • pp.39-43
    • /
    • 2011
  • To cope with recent high gas prices and global warming phenomenon, the latest gasoline engine technologies are focusing on direction injection, downsizing by turbo charging, variable compression ratio, controlled auto Ignition to enhance fuel efficiency and satisfy emission regulations. The variable valve train technology will be a basement for these innovative technologies in internal combustion engines and is supposed to play a key role to improve low thermal efficiency and pumping loss in gasoline engine caused by low compression ratio and throttled operation respectively.

  • PDF

A Study on the Spontaneous Ignition Characteristics of Wood Pellets related to Change in Flow Rate (공기유량의 변화에 대한 우드펠릿의 자연발화 특성에 관한 연구)

  • Kim, Hyeong-Seok;Choi, Yu-Jung;Choi, Jae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.590-596
    • /
    • 2019
  • Uses of fossil fuels like coal and oil increases with industrial development, and problems like abnormal climate come up as greenhouse gas increases. Accordingly, studies are actively conducted on eco-friendly renewable energy as a replacement for the main resources, and especially, wood pellets with high thermal efficiency are in the limelight as an alternative fuel in thermal power stations and gas boilers. However, despite a constant increase in their usage, few studies are conducted on their risks like fire and spontaneous combustion. Thus, this study found the auto-ignition temperature and critical ignition temperature of wood pellets with a change in flow rate in a thermostatic bath, using a sample vessel with 20 cm in length, 20 cm in height and 14 cm in thickness to predict their ignition characteristics. Consequently, at the flow rate of 0 NL/min, as the core temperature of the sample increased to higher than the ambient temperature, they ignited at $153^{\circ}C$, when the critical ignition temperature was $152.5^{\circ}C$. At the flow rates of 0.5 NL/min and 1.0 NL/min, it was $149.5^{\circ}C$, and at the flow rate of 1.5 NL/min, it was $147.5^{\circ}C$. Consequently, at the same storage, the more the flow rate, the lower the critical ignition temperature became.