• Title/Summary/Keyword: astigmatic axis

Search Result 17, Processing Time 0.024 seconds

Changes of Corrective Astigmatism Values Depending on Position of Circle of Least Confusion in Astigmatic Refining Test Using Cross Cylinder (크로스실린더를 이용한 난시정밀검사에서 검사 전 최소착란원 위치에 따른 난시교정값의 변화)

  • Kim, Sang-Yeob;Lee, Min Jae;Lee, Kang Cheon;Lee, Tae Hui;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.349-354
    • /
    • 2015
  • Purpose: To investigate the changes of corrective values of astigmatism caused by the position of circle of least confusion on retina in refining astigmatic test using cross cylinder. Methods: 62 subjects (115 eyes) aged $22.24{\pm}2.48$ years participated for this study. After astigmatic test using a radial chart, refining test was performed using a cross cylinder in a condition of maximum plus to maximum visual acuity (MPMVA). Astigmatic refining test was repeatedly performed in each condition of which S+0.75 D, S+0.50 D, S+0.25 D, S-0.25 D, S-0.50 D, and S-0.75 D are added to spherical lenses of MPMVA. The measured values were compared with the values in MPMVA condition. Results: As compared with values in condition of MPMVA, change of astigmatic axis was increased with add the power of (+) spherical lenses and (-) spherical lenses. In same spherical condition, change of astigmatic axis was decreased with increment of astigmatic power (p<0.05). The corrective power of astigmatism was reduced with increment of (+) spherical lenses (p<0.05), and was raised with increment of (-) spherical lenses compared with the power in MPMVA condition. In case of adding (+) spherical lenses, difference of astigmatic power increased with increment of corrective astigmatism power in same test condition. Conclusions: In order to obtain a proper values for corrective astigmatism, position of circle of least confusion should be accurately adjusted before the performing an astigmatism's refining test.

Clinical Study on Measurement Accuracy of Astigmatic Components (난시성분의 측정 정확도에 관한 임상적 연구)

  • Yoo, Jong-Sook;Sung, A-Young;Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.1
    • /
    • pp.63-69
    • /
    • 2006
  • Clinical evaluation by Astigmatic Components of autorefractors was performed to examine validity and accuracy compared with subjective refraction. The mean cylindrical powers of Astigmatic Components of Subjective Refraction, Closed-view and Open-view were found to be $-0.689{\pm}0.516D$, $-0.691{\pm}0.530D$, $-0.470{\pm}0.507D$, respectively. The Difference of cylindrical Components between Subjective Refraction and Closed, Open-view were found to be $0.002{\pm}0.191D$, $0.015{\pm}0.137D$, respectively. Approximately 85% of Closed-view and Open-view autorefractor measurements were within ${\pm}20^{\circ}$ range of the difference of cylindrical axis with subjective refraction. The mean $J_0$ Components of Astigmatic Components of subjective refraction, Closed-view and Open-view were found to be $-0.155{\pm}0.332D$, $-0.004{\pm}0.178D$, $-0.001{\pm}0.156D$, respectively. The mean $J_{45}$ Components of Astigmatic Components, Closed-view and Open-view were found to be $-0.023{\pm}0.227D$, $-0.026{\pm}0.172D$, $-0.014{\pm}0.182D$, respectively. Both of the Closed-view and Open-view refractor showed available accuracy in measuring astigmatic components.

  • PDF

Loss of Corrected Visual Acuity According to Different Meridional Visual Acuity in Astigmatic Eyes (난시안에서 주경선 간 시력차이와 교정시력의 손실)

  • Jo, Na Young;Kim, Sang-Yeob;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.77-81
    • /
    • 2016
  • Purpose: This study was performed to investigate the difference of meridional visual acuity and the loss of corrected visual acuity (VA) in order to emphasis the importance of astigmatic correction. Methods: 64 subjects (122 eyes) aged $22.75{\pm}2.36years$ participated in this study. After full correction of astigmatic refractive error, VA was measured in which the direction of the slit filter was matched with astigmatic axis and $90^{\circ}$ to the astigmatic axis. Results: 52 eyes showed no difference in VA between the two direction. However 70 eyes had difference VA between them. 14 out of 52 eyes and 24 out of 70 eyes had under 1.0 in monocular VA. The astigmatic degree was higher in the existence of VA difference between the two direction than non-existence. The difference is higher with under 1.0 monocular VA. Monocular VA is closely related to the focal line having better VA in the principal focal line. Glasses replacement period was analyzed as 6~12 months for the preservation of better VA. Conclusions: The final glasses prescription has to be given with full correction because continued under-correction for astigmatism causes meridional VA difference.

A Study on the Accommodative Astigmatism of Near Vision (근거리 주시 시 조절성 난시에 대한 연구)

  • Lee, Hark-Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.327-331
    • /
    • 2011
  • Purpose: The purpose of this study was an accurate grasp of the astigmatic change due to eyes accommodation on near vision and suggested problems occurring accommodative astigmatism using near glasses. Methods: 154 subjects(308eyes) from 20 to 40 years selected for this study who had many opportunity of near vision. First, far vision corrective refraction measured using the phoropter, and then both eyes opened simultaneously for maintaining the function of binocular put away dot chart 40 cm. One eye was fogging and the other eye measured near vision astigmatism axis and degrees astigmatism using cross cylinder, and then compared with far astigmatism. Results: Increased degree of astigmatism persons on near vision more than decreased or did not changed degree of astigmatism persons, which could affect visual acuity more than 0.75 diopters in 30 eyes with an increase of 9.7% of total subjects. Direct astigmatism and oblique astigmatism were increased on near vision. Astigmatic axes were rotated base in direction on both eyes and 66.9% of subjects were more than ${\pm}$5$^{\circ}$ rotation. Due to the rotation axis of astigmatism, residual astigmatism is expected to occur and expect to adversely affect the eyes. Conclusions: Long-term using the glasses without correction of increased astigmatic and rotated axis on near vision should occur new residual astigmatism and increase the asthenopia also. Considered to be taken astigmatic change on near vision during near refraction examination.

A Correlation between Axis-Rotation and Corneal Astigmatism in Toric Soft Contact Lens Fitting (토릭소프트렌즈 피팅 시 축 회전과 각막난시와의 상관관계)

  • Park, Hyung Min;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.189-198
    • /
    • 2014
  • Purpose: The present has analyzed the correlation between the direction of lens and the amount of rotation upon soft toric contact lens fitting after classifying the corneal astigmatism. Methods: Soft toric contact lens was fitted on 114 with-the-rule astigmatic eyes with total astigmatism of at least -0.75 D in their 20s and 30s according to the fitting guideline of the manufacturer and the correlation between the astigmatic degree and the rotational direction/amount of rotation was analyzed by when keeping the eyes on the front and by changing the direction of gaze. As for re-orientation movement. The speed of lens re-orientation and total amount of lens rotation was compared and analyzed by corneal astigmatism after mis-location of lens of $45^{\circ}$ to temporal and nasal direction, respectively. Results: The positive correlations were shown between corneal astigmatism and the direction of lens rotation and between corneal astigmatism and the amount of lens rotation. Meanwhile, the amount of lens rotation was different by the direction of gaze however, there was no correlation with corneal astigmatism. The speed of lens re-orientation was fastest in the group of high astigmatic degree when the lens was mis-located to both temporal and nasal directions. Conclusions: For optimal axis stabilization of toric soft lens, it is proposed that the adjustment of fitting guideline considering corneal astigmatism is necessary since the current fitting guideline is only based on total astigmatism.

Association between astigmatism and amblyopia.

  • Sapkota, Kishor;Kim, Douk Hoon
    • Journal of Korean Clinical Health Science
    • /
    • v.10 no.1
    • /
    • pp.1553-1558
    • /
    • 2022
  • Purpose: The aim of this study was to determine the association between stigmatism and amblyopia. Methods: It was a hospital based, cross-sectional retrospective study conducted in Nepal Eye Hospital. Medical record of amblyopic children aged 13 years or younger from were reviewed. Children with amblyopic eyes due to simple astigmatism were included. Relation between depth of amblyopia with magnitude and types of astigmatism, orientation of axis was determined. Out of 139 amblyopic eyes of 82 children, 93 were simple myopic astigmatism and remaining 42 were simple hyperopic astigmatism. Results: Mean age of patients was 7.38±2.61 years. Visual acuity improved by at least one line in Snellen chart in 4/5th of eyes after astigmatic correction. Moderate amblyopia was found to be present in 45% eyes while severe amblyopia in 16% of eyes. With the rule astigmatism was found to be present in 88% eyes. Mean astigmatism was 2.47±0.98D and majority of eyes (67.7%) had high astigmatism. Depth of amblyopia was not associated with magnitude of astigmatism (p > 0.05) but number of lines improved with astigmatic correction was correlated with the magnitude of astigmatism (p < 0.001). Risk of amblyopia is more in high myopic astigmatism. Conclusion: Presenting age of amblyopic children was late in Nepal. Depth of amblyopia was not associated with magnitude of astigmatism.

A Study on the Relationship between the Disc of Least Confusion and Corrected Vision of Astigmatism (난시안의 최소착락원과 교정시력과의 관계 연구)

  • Kim, Jung-Hee;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.51-57
    • /
    • 2008
  • Purpose: This study has been conducted to know how the size and position of the circle of least confusion has an influence on the vision for minimization of asthenopia when astigmatism is corrected and appropriated prescription to provided clear vision life. Methods: The method of the study has been worked on 68 students (136 eyes) of man and woman enrolled in university of Gyeong-gi-do aged 20 to 40, who have myopic astigmatism in order to know how the corrected vision changes according to the size and position of the circle of least confusion of astigmatism, the vision has been tested by giving the vision whose astigmatic power of 0.25D and 0.50D was just reduced, low correcting the astigmatic power into 0.50D, and at the same time inserting additionally spherical power -0.25D, all under a condition that the corrected vision after completely corrected astigmatism, and the axis of astigmatism was not changed. Results: The average vision was 1.047 when the astigmatic power was fully corrected, and in low correction of 0.25D, it was 0.914, and in low correction of 0.50, it was 0.772. It has been learned that the bigger the circle of least confusion was the bigger the range of vision reduction and the corrected vision in astigmatism has correlation with the size of the circle of least confusion. It has been examined that the average vision according to position of the circle of least confusion in astigmatism was 1.047 when the astigmatic power was completely corrected and focused on the retina with state of point, and in case that the astigmatic power was 0.50D of state of low correction, that is, the circle of least confusion was focused before retina, it was 0.828, and it was also 0.826 when the astigmatic power is low corrected with 0.50D and the circle of least confusion was focused on the retina. Explained briefly, It has been examined that in case that the state of low correction of the astigmatic power was same, the vision reduction was less in the image of the circle of least confusion focused upon the retina than in the image of its being focused before the retina. Conclusions: In case that the refractive power of cylindrical lens is reduced in test of wearability in astigmatism, there needs surely an adjustment of spherical lens that can place the circle of least confusion on the retina.

  • PDF

Effect of Visual acuity for Change of Astigmatism axis in Myopic astigmatism (근시성 난시안에서 난시축 변화가 시력에 미치는 영향)

  • Choi, Jun-Gyu;Kim, Bo-Yun;Lee, Eun-Hee
    • Journal of Digital Convergence
    • /
    • v.13 no.12
    • /
    • pp.285-290
    • /
    • 2015
  • The purpose of this study is to compare the status of eyesight according to the change of astigmatism axis in myopic astigmatism and to minimize errors in making astigmatic glasses based on accurate optometry and prescription. The subjects were 93 males and females(186 eyes) who have myopic astigmatism without any ocular disease or systemic disease. We performed comparative analysis on the status of visual acuity according to the change of astigmatism axis to 5, 10 and 15 degree in corrected eyesight 1.0. The direct astigmatism was the most common astigmatism type among the 186 eyes. After all subjects were perfectly corrected into 1.0, the change of astigmatism axis affected eyesight; The results suggested that the more change was made in astigmatism axis, the worse their eyesight would become. The main astigmatism type was changed from direct astigmatism to inverse astigmatism as age increased. The change of the astigmatism axis resulted in failing of corrected eyesight. Therefore, the convergence of examination and correction for astigmatism strength and axis is necessary when conducting refraction inspection for astigmatism.

Cause Analysis in Decrease of Body Stability According to The Induced Astigmatic Blur (유발된 난시성 흐림에 의한 신체 안정성 감소의 원인분석)

  • Kim, Sang-Yeob;Yu, Dong-Sik;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.259-264
    • /
    • 2016
  • Purpose: To establish the cause of decrease in body stability and to analyze the effects on sensory organs maintaining static balance according to the induced astigmatic blur. Methods: Twenty subjects (10 males, 10 females; mean age, $23.40{\pm}2.70years$) were participated in this study. To induce myopic simple astigmatism, the axis directions of cylindrical lenses were placed $180^{\circ}$ on both eyes (with-the-rule), $90^{\circ}$ on both eyes (against-the-rule), and $45^{\circ}$ on both eyes (oblique). Cylindrical lenses of +0.50, +1.00, +1.50, +2.00, +3.00, +4.00, and +5.00 D were used to increase astigmatic blur in each astigmatism types. General stability (ST) and sway power (SP) in frequencies by each sensory organs were analyzed using the TETRAX biofeedback system. Results: ST in the all astigmatism types were raised with increase of astigmatic blur compared to full corrected condition, but a significant difference only showed in the induced oblique astigmatism. According to the results of correlation analysis between ST and SP in the each frequencies with increase of astigmatic blur, the causes of increased ST in the induced oblique astigmatism showed to have a high correlation in order of somatosensory system (high-medium frequency), central nervous system (high frequency), peripheral vestibular system (low-medium frequency), and visual system (low frequency). Conclusions: The visual information by uncorrected oblique astigmatism may disturb the normal functions of all sensory organs maintaining body balance, consequently, the body stability can be reduced. Therefore, optimal correction of astigmatism can play an important role for reducing the instability of body balance.

The Study of Abnormal Refraction Eye on Women Population of University Students in South-East Korea (한국 동남지역 여대생들의 굴절이상 눈에 대한 연구)

  • Choi, Hoe-Sung;Jung, Su-Ja;Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.125-129
    • /
    • 2008
  • Purpose: To research the study of abnormal refraction eye on women population of university students in South - East Korea. Methods: Between March 2007 and October 2007, the refraction test of eye glasses wearer was evaluated on women population (367 students, aged 19~22 years) of university in living on Kyung-Nam and Pusan province. Data was analysed with T-test. Results: On the abnormal refraction status, Compound Myopic Astigmatism was 76.72%, simple myopia was 10.90%, mixed astigmatism was 6.27%, respectively. On the prevalence of myopic power, low was 59.57%, moderate was 24.93%, high was 15.49%, respectively. On the myopic equivalent power, the right eye had more increase to compare to left eye. but these was not a statically significant correlation (p<0.5) between the right and left eyes. On the anisometropia of spherical equivalents and cylinder power, most subjects was under 1.0 diopter. On the other hand, the type of astigmatic axis was with-the rule (70.79%), against -the rule (18.41%), and oblique (10.80%). Conclusions: This study identify that the refraction status of abnormal refraction eye on women population in university students in South-East Korea have been more increased prevalence the myopia and astigmatism.

  • PDF