• Title/Summary/Keyword: area of roof opening

Search Result 12, Processing Time 0.034 seconds

Thermal and Ventilative Characteristics of Single-Span Oak Mushroom Production Facility as Affected by Area of Roof Opening and Shading Rates (단동 표고재배시설의 천창면적과 차광율에 따른 온도 및 환기특성)

  • 손정익
    • Journal of Bio-Environment Control
    • /
    • v.9 no.2
    • /
    • pp.120-126
    • /
    • 2000
  • The quality of oak mushoom(Lentinus edodes(Berk) Sing) is sensitively affected by environmental factors, especially moisture by the rain during the growing period. To protect mushrooms from being wet, plastic-covered facilities with side openings are mostly being used. However, the indoor temperature and humidity f the facility without roof opening become higher due to its poor ventilation, and consequently reduce the productivity and quality as well. In this study, we analyzed the ventilation rates and indoor temperatures of improved facilities as affected by the area of roof opening and shading rate by the model. The indoor temperature decreased by more than 2.5$^{\circ}C$ as the shading rate increased from 50% to 90%, and especially the effect of wind speed on indoor temperature was significantly great under as low as 50% of shading rate. The ventilation rate became higher under wind speed of 1~2m.s-1 regardless of the shading rate. As the wind speed increased from 0m.s-1 to 2m.s-1, the indoor temperature decreased by more than 2.$0^{\circ}C$. Moreover, the indoor temperature became lower with increasing roof opening ratio, but showed no significant differences at more than 50% of roof opening ratio. At lower shading rate, the indoor temperature sensitively decreased with increasing area of roof opening. Additionally, we obtained the higher ventilation performance with the area of roof opening more or less equal to side opening, regardless of the wind speed and shading rate.

  • PDF

Stresses around an underground opening with sharp corners due to non-symmetrical surface load

  • Karinski, Y.S.;Yankelevsky, D.Z.;Antes, M.Y.
    • Structural Engineering and Mechanics
    • /
    • v.31 no.6
    • /
    • pp.679-696
    • /
    • 2009
  • The paper aims at analyzing the stress distribution around an underground opening that is subjected to non-symmetrical surface loading with emphasis on opening shapes with sharp corners and the stress concentrations developed at these locations. The analysis is performed utilizing the BIE method coupled with the Neumann's series. In order to implement this approach, the special recurrent relations for half plane were proven and the modified Shanks transform was incorporated to accelerate the series convergence. To demonstrate the capability of the developed approach, a horseshoe shape opening with sharp corners was investigated and the location and magnitude of the maximum hoop stress was calculated. The dependence of the maximum hoop stress location on the parameters of the surface loading (degree of asymmetry, size of loaded area) and of the opening (the opening height) was studied. It was found that the absolute magnitude of the maximum hoop stress (for all possible surface loading locations) is developed at the roof points when the opening height/width ratio is relatively large or when the pressure loading area is relatively narrow (compared to the roof arch radius), and contrarily, when the opening height/width ratio is relatively small or when the surface pressure is applied to a relatively wide area, the absolute magnitude of the maximum hoop stress is developed at the bottom sharp corner points.

Analysis of Wind Pressure Characteristics of Retractable Dome Roof by Opening Type Through Wind Tunnel Test (풍동실험을 통한 개폐 유형별 개폐식 돔 지붕의 풍압 특성 분석)

  • Cheon, Dong-jin;Lee, Jong-Ho;Kim, Yong-Chul;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.21 no.1
    • /
    • pp.41-49
    • /
    • 2021
  • In this study the characteristics of wind pressure that are depending on the open type of retractable dome roof were analyzed according to the wind pressure coefficient and wind pressure spectrum. The analysis results showed that the open type and shape of the roof both had a significant impact on the wind pressure changing. In case of the edge to center open type, the wind pressure has not changed much because of the complex turbulence of flow and open area. On the other hand, in case of the center to edge open type, it has confirmed that wind pressure increases due to the separation of flow in windward and open area.

Case Analysis of Open-Close Time of Retractable Building Structure and Design Wind Speed (개폐식 건축물의 개폐 시간 및 설계 풍속 사례 분석)

  • Song, Jin-Young;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.2
    • /
    • pp.79-87
    • /
    • 2017
  • The retractable roof structure is used in various fields and it is classified for steel retractable system and soft retractable system. For the domestic industry, it is in the initial phase now and the demand of the retractable roof structure is expected to increase in the future. Therefore, this paper is classified for steel retractable system and soft retractable system from the retractable roof structures in overseas to survey and analyze the cases of wind velocity on retractable roof structure in Japan that uses the same wind velocity criteria like Korea regarding the open-close time and average open-close time for retractable roof area.

Experimental Study on the Effect of a Metal Storage Cask and Openings on Flame Temperature in a Compartment Fire

  • Bang, Kyoung-Sik
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.3
    • /
    • pp.395-405
    • /
    • 2020
  • Compartment fire tests were performed using kerosene and Jet A-1 as fire sources to evaluate the relationship between flame temperature and opening size. The tests were performed for a fire caused by the release of kerosene owing to vehicle impact, and for a fire caused by the release of Jet-A-1 owing to airplane collision. The compartment fire tests were performed using a 1/3-scale model of a metal storage cask when the flame temperature was deemed to be the highest. We found the combustion time of Jet-A-1 to be shorter than that of kerosene, and consequently, the flame temperature of Jet-A-1 was measured to be higher than that of kerosene. When the opening was installed on the compartment roof, even though the area of the opening was small, the ventilation factor was large, resulting in a high flame temperature and long combustion. Therefore, the position of the opening is a crucial factor that affects the flame temperature. When the metal storage cask was stored in the compartment, the flame temperature decreased proportionally with the energy that the metal storage cask received from the flame.

A Study on Revitalization of Rooftop Garden by Assessing the Publicness : a Case of Mullae Roof Garden, Mullae-dong, Seoul (옥상텃밭의 공공성 평가에 따른 이용 활성화 방안 연구)

  • Kwang, Nae-Young
    • Journal of Korean Society of Rural Planning
    • /
    • v.22 no.3
    • /
    • pp.131-142
    • /
    • 2016
  • Urban agriculture, which can be defined as agriculture performed in a city, is suggested as an alternative solution to restore deserted community and expand green land in city area through cultivation activities. In Korea, 'Urban Agriculture Promotion and Support Act' was enforced from May 2012. In addition, in the same year, Seoul Metropolitan Government declared 'the beginning of urban agriculture era,' established municipal ordinance, and increased budget to actively support urban agriculture. As a result, urban agriculture practices have been increasing every year. Yet, the way of developing urban agriculture in a uniform way of expanding green land has led to difficulties of securing proper spaces. Accordingly, 'roof top' spaces have gained attention. This study analyzes rooftop garden, one of the spaces of carrying out urban agriculture, from the publicness perspective. The study selected a case study of a public rooftop garden in Mullae-dong, Yeongdeungpo-gu, investigated present conditions and usage features of the garden, and explored the conditions to be a 'public' roof top garden. Through theoretical analysis, both physical and non-physical indicators were derived for analysis framework; physical aspects- accessibility, locality, openness, comfortness, and non-physical aspects- subjectivity, cooperativeness, and a sense of community. The results of this study are as follows. First, openness and locality scores were the highest, and comfortness scored the lowest, in ensuring the publicness of Mullae roof top garden. Second, non-physical indicators had stronger effect than physical indicators on rooftop garden users' awareness on publicness and building a garden community. In conclusion, in order to vitalize roof top garden, users should be engaged from the very first planning stage of building a garden, opening hours should not be limited, and more importance should be put on users to subjectively manage the operation of rooftop garden than merely creating a physical environment.

Collapse of steel cantilever roof of tribune induced by snow loads

  • Altunisik, Ahmet C.;Ates, Sevket;Husem, Metin;Genc, Ali F.
    • Steel and Composite Structures
    • /
    • v.23 no.3
    • /
    • pp.273-283
    • /
    • 2017
  • In this paper, it is aimed to present a detail investigation related to structural behavior of laterally unrestrained steel cantilever roof of tribune with slender cross section. The structure is located in Tutak town in $A{\breve{g}}r{{\i}}$ and collapsed on October 25, 2015 at eastern part of Turkey is considered as a case study. This mild sloped roof structure was built from a variable I beam, and supported on steel columns of 5.5 m height covering totally $240m^2$ closed area in plan. The roof of tribune collapsed completely without any indication during first snowfall after construction at midnight a winter day, fortunately before the opening hours. The meteorological records and observations of local persons are combined together to estimate the intensity of snow load in the region and it is compared with the code specified values. Also, the wide/thickness and height/thickness ratios for flange and web are evaluated according to the design codes. Three dimensional finite element model of the existing steel tribune roof is generated considering project drawings and site investigations using commercially available software ANSYS. The displacements, principal stresses and strains along to the cantilever length and column height are given as contour diagrams and graph format. In addition to site investigation, the numerical and analytical works conducted in this study indicate that the unequivocal reasons of the collapse are overloading action of snow load intensity, some mistakes made in the design of steel cantilever beams, insufficient strength and rigidity of the main structural elements, and construction workmanship errors.

Daylighting Controls of Korean Traditional Houses built in Chosun Dynasty especially on examples located in northern Gyeongbuk province (경북북부지역 전통 양반가옥의 채광조절 기능에 관한 연구 -처마, 창호(窓戶), 창호지(窓戶紙)를 중심으로-)

  • Kim, Gon;Koo, Jae-Oh
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.79-85
    • /
    • 2004
  • There is something valuable in Korean traditional architecture that does not change even after more than a number of years. Each design element of traditional houses has its own role to embody natural, healthy, and environment-friendly architectural planning. With traditional already-built examples located in the northern area of Gyeongbuk province, this study attempts to untangle some of the daylighting control issues in opening design. By looking at more than just photometric materials, at some threshold level, the whole of daylighting control characteristics of their openings is being surveyed from the viewpoint of geometric relationship between their roof structures and windows. As a glazing material, in addition, Korean traditional window covering paper, Changhoji, is evaluated for its transmittal performance under artificial and real skies as well.

A Study on the Safety in the Application of B.T.R method (B.T.R공법의 적용 시 안전에 관한 연구)

  • Lee, Won-Hui;Jeong, Gwang-Mo;Bang, Myeong-Seok;Lee, Sang-Heon
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.11a
    • /
    • pp.67-74
    • /
    • 2011
  • In this study numerical analysis was performed to evaluate the safety of Built-in Timbering Roof Type Tunnelling Method(BTR) which is one of non-opening tunnel construction methods. For the upgrading of analytical precision was applied the discretion method which can separately model reinforcing elements of BTR and the homogeneity analysis considering the area ratio of elements was performed to compare both results. Comparing the displacement in this study with that of the homogeneity method, the efficiency of the discretion method was verified.

  • PDF

Analysis of the Air-flow for Natural Ventilation of Express Bus (고속버스 자연환기구의 기류패턴 분석)

  • Yoo, Ho-Chun;Noh, Kyoung-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.336-341
    • /
    • 2009
  • In express bus which has no window, the air quality inside the bus is very critical for the passengers who staying for an extended time. Air conditioning system using natural energy is expected to significantly improve the air quality while the bus runs the suburban area. But the express buses today usually attempt to ventilate using air conditioning system, rather than natural ventilation. In this study, analysis of existing ventilation opening and the new ventilation system on roof, using computer simulation. As a result, two cases using existing ventilation device was found to be effective for partial ventilation only, while the air in front remains standstill. The new system proved to have promoted more dynamic ventilation in most of space.

  • PDF