Search Result 123, Processing Time 0.023 seconds

Effect of Fluoride Treatment after Bleaching with Hydrogen Peroxide exposed to Plasma Arc (고농도 과산화수소와 플라즈마 아크를 이용한 미백 치료에 있어서 불소의 효과)

  • Chung, Sun-Young;Lee, Young-Eun;Ahn, Sang-Hun;Yang, Hae-Young;Jeon, Eun-Suk;Choi, Youn-Hee;Song, Keun-Bae
    • Journal of dental hygiene science
    • /
    • v.11 no.4
    • /
    • pp.375-380
    • /
    • 2011
  • This study evaluated whether fluoride treatment can affect recovery of the irregularity of enamel surface after tooth whitening with a high concentration of hydrogen peroxide (HP) activated by plasma arc light. A total of 36 bovine teeth stained with coke were used in this experiment. The specimens were classified into following three groups (two different commercial plasma arc groups and a control group without light curing source): (1) 35% HP gel only, (2): 35% HP gel and Plasma arc A, and (3) 35% HP gel and Plasma arc B. To measure color changes and surface morphologies before and after the bleaching, colorimeter and scanning electron microscopy were used, respectively. When the specimens were bleached with hydrogen peroxide and plasma arc lights, the bleaching effect was greater than when only hydrogen peroxide gels were used (Kruskal-Wallis test, p<0.05). In addition, plasma arc B showed the more color changes than plasma arc A (Bonferroni post-hoc test, p<0.05). The surfaces of the teeth treated with fluoride gel after the whitening treatment came to be smooth. Therefore, the results of this study suggested that the fluoride application for patients who got tooth whitening therapy with a high concentration of hydrogen peroxide gels activated by plasma arc light will be effective to recover rough enamel surfaces.

Development of Prediction of Electric Arc Risk using Object Dection Model (객체 탐지 모델을 활용한 전기 아크 위험성 예측 시스템 개발)

  • Lee, Gyu-bin;Kim, Seung-yeon;An, Donghyeok
    • Smart Media Journal
    • /
    • v.9 no.1
    • /
    • pp.38-44
    • /
    • 2020
  • Due to the high dependence on electric energy, electric fires make up a significant portion of fires in Korea. Electric arcs by short circuits or poor contact cause three of four electrical fires. An electric arc is a discharge phenomenon of electrical current between the insulators, which instantaneously produces high temperature. In order to reduce the fire due to electric arc, this study aims to predict the electric arc risk. We collected arc data from the arc detectors and converted into graphs based on temporal arc data. We used machine learning for training converted graph with different number of temporal arc data. To measure the performance of the learning model, we use the test data. In the results, when the number of temporal arc data was 20, the prediction rate was high as 86%.

Insights on the rotation measure of the M87 jet on arc-second scales

  • Algaba, Juan-Carlos;Asada, Keiichi;Nakamura, Masanori
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.73.2-73.2
    • /
    • 2014
  • We investigate the rotation measure (RM) of the nearby low luminosity AGN M87 by using archival polarimetric VLA data at 8, 15, 22 and 43 GHz. For the first time, the RM properties of its jet are resolved at at arc-second scales. The distribution of the RM appears to be a gaussian with a mean value of ~200rad/m2 and the power spectrum follows a power law with index -2.5. A simple Kolmogorov model assuming a random turbulent magnetic fields extrinsic to the jet appears not to be adequate to explain the observed RM power spectra. On the other hand, underlying RM gradients possibly connected with the jet could be a possible interpretation.

  • PDF

A Study of Weld Pool width Control in Gas Tungsten Arc Welding Using the Digital Image Processing (화상처리에 의한 Gas Tungsten Arc 용접에서의 용융지폭제어에 관한 연구)

  • Kim, Dong-Cheol;Rhee, Sehun;Um, Ki-Woan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.9
    • /
    • pp.2760-2769
    • /
    • 1996
  • The feedback control systems of welding process using visual information can improve weld qualities. However, it is very difficult to get the visual information of weld pool since the light intensity of welding arc is much stronger than that of the weld pool. To explore the possibility of extending the capability of automatic welding machines, a study of a closed loop controlled welding system consisted of a GTA welding machine, a vision system, a stepping motor system and a digital computer was undertaken. Particularly, in this system, a CCD camera with a long wavelength pass filter was used to get a better weld pool image. Subsequently, an image analysis technique has been developed to measure the weld pool width. Using this weld pool width measurement, a colsed loop control system adjusted welding speed to maintain a constant weld pool width.

A Didactical Analysis on Circular Measure (호도법에 관한 교수학적 고찰)

  • Kang, Mee-Kwang
    • The Mathematical Education
    • /
    • v.50 no.3
    • /
    • pp.355-365
    • /
    • 2011
  • The purpose of this study is to provide mathematical knowledge for supporting the didactical knowledge on circular measure and radian in the high school curriculum. We show that circular measure related to arcs can be mathematically justified as an angular measure and radian is a well defined concept to be able to reconcile the values of trigonometric functions and ones of circular functions, which are real variable functions. Radian has two-fold intrinsic attributes of angular measure and arc measure on the unit circle, in particular, the latter property plays a very important role in simplifying the trigonometric derivatives. To improve students's low academic achievement in trigonometry section, the useful advantage and the background over the introduction of radian should be preferentially taught and recognized to students. We suggest some teaching plans to practice in the class of elementary and middle school for enhancing teachers' and students' understanding of radian.

Comparison of characteristics of MgO films deposited by vacuum arc method with other methods. (진공아크 증착법과 다른 공정에 의해 증착된 MgO 박막 특성 비교)

  • 이은성;김종국;이성훈;이건환
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.2
    • /
    • pp.112-117
    • /
    • 2003
  • MgO films is widely used in plasma display panel (PDP) technology. In this work, structural and optical properties of the MgO films deposited by e-beam evaporation, reactive magnetron sputtering, which are commercially used, and arc deposition were compared. MgO thin films were deposited on glass substrates by vacuum arc deposition equipment using a magnesium metal target at various oxygen gas flows. In order to investigate the packing density by ellipsometer, to measure reasonable erosion-rates of the MgO protective layers, we introduced an acceleration test method, namely, Ar+ ion beam induced erosion test. Also, XPS and UV test were adopted to examine the effect of the moisture on the optical transmittance of the MgO protective layers, which showed that these of MgO films by arc deposition method sustained more 90% and were insensitive to effect of the moisture. XRD and AFM have been also used to study behaviors of the structure and surface morphology.

A Historical and Mathematical Analysis on the Radian (라디안 개념의 역사적 분석과 수학적 분석)

  • Yoo, Jaegeun;Lee, Kyeong-Hwa
    • Journal of Educational Research in Mathematics
    • /
    • v.27 no.4
    • /
    • pp.833-855
    • /
    • 2017
  • This study aims to reinvestigate the reason for introducing radian as a new unit to express the size of angles, what is the meaning of radian measures to use arc lengths as angle measures, and why is the domain of trigonometric functions expanded to real numbers for expressing general angles. For this purpose, it was conducted historical, mathematical and applied mathematical analyzes in order to research at multidisciplinary analysis of the radian concept. As a result, the following were revealed. First, radian measure is intrinsic essence in angle measure. The radian is itself, and theoretical absolute unit. The radian makes trigonometric functions as real functions. Second, radians should be aware of invariance through covariance of ratios and proportions in concentric circles. The orthogonality between cosine and sine gives a crucial inevitability to the radian. It should be aware that radian is the simplest standards for measuring the length of arcs by the length of radius. It can find the connection with sexadecimal method using the division strategy. Third, I revealed the necessity by distinction between angle and angle measure. It needs justification for omission of radians and multiplication relationship strategy between arc and radius. The didactical suggestions derived by these can reveal the usefulness and value of the radian concept and can contribute to the substantive teaching of radian measure.

Electron density measurment in arc discharge using Mach-Zenhder interferometer (Mach-Zenhder 간섭계를 이용한 아크방전 중의 전자밀도 측정)

  • Cho, J.H.;Roh, Y.S.;Lee, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1898-1900
    • /
    • 1996
  • The Laser aided diagnostic method makes it possible to diagnose plasma characteristics which have never been done by other one. The aim of this study is to measure the electron density profile of an arc plasma by Mach-Zenhder interferometer. The two laser beams (He-Ne and Argon Lasers), which are different in wavelength, pass across an arc plasma and meet a change of refractivity which makes fringe shifts. From this effects we could find densities of electron and neutral particle.

  • PDF

A Study on Wear Resistance of TiN Films Prepared by Arc Vapor Ion Deposition Process (Arc Vapor Ion Deposition 법으로 제조된 TiN 피막의 내마모성에 관한 연구)

  • 신현식;한전건;장현구;고광진
    • Journal of the Korean institute of surface engineering
    • /
    • v.27 no.1
    • /
    • pp.36-44
    • /
    • 1994
  • The TiN films were deposited on the stainless substrates using arc vapor ion deposition process to in-vestigated the wear resistance. Pin-on-disc tests were performed to measure the volume wear loss of TiN films. The substrate bias voltages and nitrogen flow rates were selected as the deposition parameters of TiN films. It was found that the wear resistance of TiN films was enhanced with increasing bias voltages(0~-300 V) and nitrogen flow rates(220~380 SCCM). The volume wear loss TiN films were about 9.5~2.1$\times$$10^{-3}mm^3$ and 3.5~2.2$\times$$10^{-3}mm^3$ with bias voltages and nitrogen flow rates, respectively.

  • PDF

Understanding of Degree and Radian by Measuring Arcs (호의 측도로 도(Degree)와 라디안 이해하기)

  • Choi, Eun Ah;Kang, Hyangim
    • School Mathematics
    • /
    • v.17 no.3
    • /
    • pp.447-467
    • /
    • 2015
  • The purpose of this study is to examine how the learning experience understanding degree and radian as the measurement of arc affects the conceptual understanding of radian and measuring angle. For this purpose, we investigated pre-service teachers' understanding about measurement of angle using a length of arc, and then conducted a teaching experiment with two middle school students. The results of analyzing pre-service teachers' and students' response are as follows. Students' experience interpreting the concept of degree into measurement of arc had a positive effect on understanding of radian and students' learning process in which they got measurement of angle as measurement of arc enabled conceptual understanding of 'linear measuring'. Also a circle context and a strategy dividing by arc operated as effective strategies for solving various problems about an angle. Finally, we confirmed that providing direct manipulative activities as a chance to explore relationships between an angle and arc measure can help students' conceptual understanding of measuring angle.