• 제목/요약/키워드: annulus

검색결과 492건 처리시간 0.024초

소 대동맥 판막륜을 가진 대동맥판막 협착증 치험 1례 보고 (Aortic Valve Replacement with Patch Enlargement of Aortic Annulus in Aortic Stenosis with small aortic Annulus.)

  • 권오춘
    • Journal of Chest Surgery
    • /
    • 제18권4호
    • /
    • pp.663-666
    • /
    • 1985
  • Whatever a surgeon choose aortic prosthesis in aortic stenosis, it will always provoke some degree of obstruction to flow due to its smaller effective orifice area to tissue annulus. Occasionally, we meet small aortic annulus to his or her body surface area in aortic valve replacement. The small annulus remains a problem in that both tissue and mechanical prosthesis have significant pressure gradients between LV and aorta in resting or exercising states. In these circumstances, diverse surgical procedures, such as tilting disc prosthesis, supraannular position of aortic prosthesis, and enlargement of aortic root [including aortoventriculoplasty, translocation of aortic valve, & double outlet of LV by valved conduit], were applied. We experienced one case of aortic stenosis with small aortic annulus. Systolic pressure gradients between LV & aorta were 90 mmHg. Diameter of annulus was 19 mm. So we performed patch enlargement of aortic root by Manouguian and AVR with St. Jude medical valve 23 mm.

  • PDF

Effects of Pool Subcooling on Boiling Heat Transfer in an Annulus

  • Kang, Myeong-Gie
    • Nuclear Engineering and Technology
    • /
    • 제36권5호
    • /
    • pp.460-474
    • /
    • 2004
  • Effects of liquid subcooling on pool boiling heat transfer in an annulus with an open bottom have been investigated experimentally. A tube of 19.1mm diameter and the water at atmospheric pressure have been used for the fest. Up to $50^{\circ}C$ of liquid subcooling has been tested and experimental data of the annulus have been compared with the data of a single unrestricted tube. Temperatures on the heated tube surface fluctuate only slightly regardless of the heat flux in the annulus, whereas high variation is observed on the surface of the single tube. An increase in the degree of subcooling decreases heat transfer coefficients greatly both for the single tube and the annulus. Heat transfer coefficients increase suddenly at ${\Delta}T_{sub}\;{\le}\;10^{\circ}C$ and much greater change in heat transfer coefficients is observed at the annulus. To obtain effects of subcooling on heat transfer quantitatively, two new empirical equations have been suggested, and the correlations predict the empirical data within ${\pm}30\%$ error bound excluding some data at lower heat transfer coefficients.

POOL BOILING HEAT TRANSFER IN A VERTICAL ANNULUS WITH A NARROWER UPSIDE GAP

  • Kang, Myeong-Gie
    • Nuclear Engineering and Technology
    • /
    • 제41권10호
    • /
    • pp.1285-1292
    • /
    • 2009
  • The effects of the narrowed upside gap on nucleate pool boiling heat transfer in a vertical annulus were investigated experimentally. For the study, a stainless steel tube with a diameter of 25.4 mm and saturated water that kept an atmospheric condition were used. The ratio between the gaps measured at the upper and the lower regions of the annulus ranged from 0.18 to 1. Two different lengths of the modified gap also were investigated. The change in heat transfer due to the modified gap became evident as the gap ratio decreased and the length of the gap increased. As the gap ratio became less than 0.51, a significant decrease in heat transfer was observed compared to the plain annulus. The longer gap size resulted in an additional decrease in heat transfer. The major cause for the tendency was attributed to the formation of lumped bubbles around the upper region of the annulus followed by the increased flow friction between the fluid and the surface around the modified gap.

하부폐쇄 환상공간의 외부 튜브길이가 풀비등에 미치는 영향 (Effects of Outer Tube Length on Pool Boiling in an Annulus with Closed Bottoms)

  • 강명기
    • 대한기계학회논문집B
    • /
    • 제30권8호
    • /
    • pp.749-755
    • /
    • 2006
  • To improve pool boiling heat transfer in an vertical annulus with closed bottoms, the length of an outer tube has been changed from 0.2m to 0.6m. For the test, a heated tube of 19.1mm diameter and water at atmospheric pressure have been used. Annular conditions are made using glass tubes fabricated around the heated tube. The gap size of the annulus is 3.65mm. To elucidate effects of the outer tube length on heat transfer results of the annulus are compared with the data of a single unrestricted tube and the annulus with wider gap size of 6.35mm. Throughout the tests much higher heat transfer coefficients are observed for the annulus of 3.65mm gap size comparing to the other two cases. The change in the outer tube length results in much variation in heat transfer coefficients. Moreover, with shortening the length of outer tube the possibility of the CHF occurrence can be removed.

Flow-forming 공법을 이용한 annulus gear 제조 기술 연구 (Study on the manufacturing technology of the annulus gear by using flow-forming method)

  • 이성민;김봉준;변원용;김태덕;박은수;권용남
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.261-262
    • /
    • 2011
  • Conventional automatic transmission system includes a hydrodynamic torque converter to transfer engine torque from an engine crank shaft to a rotatable input members, which are of complex design permitting them to serve several functions. These are clutches or brakes which couple the rotatable input member to member of a planetary gear set. The annulus gear for an automatic transmission is a monolithic gear having a set of gear teeth formed on an inner surface which is coupling with a set of planetary gear. In this study, the flow forming method is applied to the manufacturing of the annulus gear. This cold forming is proper method in order to manufacture dimensionally precise and round hollow components such as annulus gear. By pre-calculated amount of wall thickness reduction, the seamless tube of SAE1026 is compressed above its yield strength, plastically deformed and made to flow in several roll passes. According to this study, the desired geometry of the annulus gear can be achieved when the outer diameter and the thickness of the tube are properly decreased by compressed roll passes and the available material volume is easily forced to flow longitudinally over the shape of mandrel.

  • PDF

일정 온도 벽면을 갖는 수평 환형공간 내의 유체의 자연 대류에서의 삼중해 (TRIPLE SOLUTIONS IN NATURAL CONVECTION OF A FLUID IN A HORIZONTAL ANNULUS WITH CONSTANT TEMPERATURE WALLS)

  • 유주식
    • 한국전산유체공학회지
    • /
    • 제22권1호
    • /
    • pp.110-115
    • /
    • 2017
  • Natural convection of a fluid with the Prandtl number of 7(water) in a horizontal annulus with constant temperature walls is numerically investigated. The inner cylinder is hotter than the outer cylinder. The flows are classified by the number of eddies in a half annulus. It is found that dual or triple solutions exists above a critical Rayleigh number for an annulus with a aspect ratio $D_i/L=4$. Transitions of $3{\rightarrow}1$ and $2{\rightarrow}1$ eddy flow occur with decrease of Rayleigh number. However, reverse transitions of $1{\rightarrow}3$ and $1{\rightarrow}2$ eddy flow do not occur with increase of Rayleigh number, and no hysteresis phenomenon is observed. In the regime of triple solutions, the 3 eddy flow has the largest mean Nusselt number value and the 1 eddy flow has the smallest value.

발포 알루미늄이 삽입된 환형관에서의 압력손실 및 강제대류 열전달 (Pressure Loss and Forced Convective Heat Transfer in an Annulus Filled with Aluminum Foam)

  • 노주석;이계복;이충구
    • 설비공학논문집
    • /
    • 제17권9호
    • /
    • pp.855-862
    • /
    • 2005
  • An experimental investigation has been carried out for aluminum foam heat sink inserted into the annulus to examine the feasibility as a heat sink for high performance forced water cooling in the annulus. The local wall temperature distribution, inlet and outlet pressures and temperatures, and heat transfer coefficients were measured for heat flux of 13.6, 18.9, 25.1, 31.4 $kw/m^2$ and Reynolds number ranged from 120 to 2000. Experimental results show that the friction factor is higher than clear annulus without aluminum foam, while the significant augmentation in Nu is obtained. This technique can be used for the compactness of the heat exchanger.

모든 색을 커버하는 최소 두께 직사각형 고리를 계산하는 알고리즘 (An Algorithm for Computing a Minimum-Width Color-Spanning Rectangular Annulus)

  • 배상원
    • 정보과학회 논문지
    • /
    • 제44권3호
    • /
    • pp.246-252
    • /
    • 2017
  • 이 논문에서는 모든 색을 커버하는 최소 두께를 갖는 축에 평행한 직사각형 고리를 계산하는 알고리즘을 최초로 제안한다. 직사각형 고리란 임의의 직사각형과 그 오프셋 사이의 닫힌 영역을 말하며, 따라서 두 개의 직사각형으로 정해진다. 이 때, 두 직사각형을 각각 외부 및 내부 직사각형이라 부른다. 직사각형 고리의 두께는 그것을 결정하는 외부 및 내부 직사각형 사이의 거리로 정의된다. 평면 위에 k개의 색깔을 가지는 n개의 점이 주어질 때에, 임의의 직사각형 고리가 각 색깔 별 점을 적어도 하나 이상 포함하게 되면, 그것이 모든 색을 커버한다고 말한다. 이전에는 모든 색을 커버하는 최소 두께 직사각형 고리를 계산하는 알고리즘이 알려진 바 없다. 따라서 우리는 이 문제에 대한 최초의 알고리즘을 제시한다. 시간 복잡도는 $O((n-k)^3nlogn)$ 이다.

경사각이 좁은 틈새를 가지는 환상공간 내부 풀비등 열전달에 미치는 영향 (Effect of Orientation on Pool Boiling Heat Transfer in Annulus with Small Gap)

  • 강명기
    • 대한기계학회논문집B
    • /
    • 제35권3호
    • /
    • pp.237-244
    • /
    • 2011
  • 경사각이 대기압하의 포화상태인 물의 풀비등에 미치는 영향을 조사하기 위해 실험을 통한 연구를 수행하였다. 연구를 위하여 5mm의 틈새간격을 가지는 하부유로개폐 상태인 환상공간을 고려하였다. 환상공간의 내부에 설치된 튜브를 가열하였으며 튜브의 직경과 길이는 각각 25.4mm와 500mm이다. 경사각은 수평부터 수직까지 변경하였다. 본 실험의 결과를 틈새간격이 더 큰 환상공간 및 단일튜브에 대한 결과와 서로 비교하였다. 작은 틈새간격을 가지는 환상공간의 경우 경사각이 열전달에 미치는 영향은 그다지 크지 않음을 확인하였다. 그러나 환상공간이 수평상태인 경우 80kW/$m^2$에서 임계열유속이 관찰되었다. 액체 교란의 정도와 기포군집형성이 환상공간 내부 풀비등의 주된 열전달 기구로 이해된다.

자동차용 환상형 소음기에 관한 실험적 연구 (An Experimental Study on Annulus Muffler of Automobile)

  • 김병삼;송규근;심상철;정병국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.217-222
    • /
    • 2006
  • Internal combustion engine is the main source of environmental pollutants and therefore advanced technology is required to reduce harmful elements from the exhaust gases all over the world. Especially, when the exhaust gas is released front the automotive muffler, exhaust noise has many bad influence on the surrounding environment. In order to reduce the exhaust noise, it is necessary that automotive muffler must be designed for best exhaust efficiency. The sound insulation room was installed for the analysis of an acoustics characteristics of the noise from automotive muffler, in this study. Exhaust gas noise, noise distribution characteristics, pressure and temperature of exhaust gas were investigated with the change of annulus temperature of air cooled annulus automotive muffler and cooled annulus automotive muffler. The following results were obtained with this study. From the frequency analysis of automotive muffler, high noise distribution was observed in the range $100{\sim}2000Hz$. It means that the noise in this range has an dominate influence for the overall noise. Noise reduction of automotive muffler was affected by the temperature of annulus. It is caused the result that the high temperature and pressure of exhaust gas are changed lower by the drop of annulus temperature. The tendencies of noise, the temperature and pressure of exhaust gas are similar to the performance curve of engine. Exhaust gas pressure is determined by the r.p.m. of engine and affected by the cooling performance of automotive muffler.

  • PDF