Browse > Article
http://dx.doi.org/10.5516/NET.2009.41.10.1285

POOL BOILING HEAT TRANSFER IN A VERTICAL ANNULUS WITH A NARROWER UPSIDE GAP  

Kang, Myeong-Gie (Department of Mechanical Engineering Education, Andong National University)
Publication Information
Nuclear Engineering and Technology / v.41, no.10, 2009 , pp. 1285-1292 More about this Journal
Abstract
The effects of the narrowed upside gap on nucleate pool boiling heat transfer in a vertical annulus were investigated experimentally. For the study, a stainless steel tube with a diameter of 25.4 mm and saturated water that kept an atmospheric condition were used. The ratio between the gaps measured at the upper and the lower regions of the annulus ranged from 0.18 to 1. Two different lengths of the modified gap also were investigated. The change in heat transfer due to the modified gap became evident as the gap ratio decreased and the length of the gap increased. As the gap ratio became less than 0.51, a significant decrease in heat transfer was observed compared to the plain annulus. The longer gap size resulted in an additional decrease in heat transfer. The major cause for the tendency was attributed to the formation of lumped bubbles around the upper region of the annulus followed by the increased flow friction between the fluid and the surface around the modified gap.
Keywords
Pool Boiling; Vertical Annulus; Upside Flow Area; Gap; Tube; Heat Transfer;
Citations & Related Records

Times Cited By Web Of Science : 0  (Related Records In Web of Science)
Times Cited By SCOPUS : 0
연도 인용수 순위
  • Reference
1 M. G. Kang, “Pool Boiling Heat Transfer on a Vertical Tube with a Partial Annulus of Closed Bottoms,” Int. J. Heat Mass Transfer, 50, 423 (2007)   DOI   ScienceOn
2 Y. H. Hung and S. C. Yao, “Pool Boiling Heat Transfer in Narrow Horizontal Annular Crevices,” ASME J. Heat Transfer, 107, 656 (1985)   DOI
3 Y. Fujita, H. Ohta, S. Uchida, and K. Nishikawa, “Nucleate Boiling Heat Transfer and Critical Heat Flux in Narrow Space between Rectangular Spaces,” Int. J. Heat Mass Transfer, 31, 229 (1988)   DOI   ScienceOn
4 M.G. Kang, “Pool Boiling Heat Transfer in a Vertical Annulus as the Bottom Inflow Area Changes,” Int. J. Heat Mass Transfer, 51, 3369 (2008)   DOI   ScienceOn
5 J. C. Passos, F. R. Hirata, L. F. B. Possamai, M. Balsamo, and M. Misale, “Confined Boiling of FC72 and FC87 on a Downward Facing Heating Copper Disk,” Int. J. Heat Fluid Flow, 25, 313 (2004)   DOI   ScienceOn
6 J. Bonjour and M. Lallemand, “Flow Patterns During Boiling in a Narrow Space between Two Vertical Surfaces,” Int. J. Multiphase Flow, 24, 947 (1998)   DOI   ScienceOn
7 W.M. Rohsenow, “A Method of Correlating Heat-transfer Data for Surface Boiling of Liquids,” ASME J. Heat Transfer, 74, 969 (1952)
8 M. H. Chun and M. G. Kang, “Effects of Heat Exchanger Tube Parameters on Nucleate Pool Boiling Heat Transfer,” ASME J. Heat Transfer, 120, 468 (1998)   DOI   ScienceOn
9 M. Shoji, “Studies of Boiling Chaos: a Review,” Int. J. Heat Mass Transfer, 47, 1105 (2004)   DOI   ScienceOn
10 M. G. Kang and Y. H. Han, “Effects of Annular Crevices on Pool Boiling Heat Transfer,” Nuclear Engineering and Design, 213, 259 (2002)   DOI   ScienceOn
11 S. C. Yao and Y. Chang, “Pool Boiling Heat Transfer in a Confined Space,” Int. J. Heat Mass Transfer, 26, 841 (1983)   DOI
12 H.W. Coleman and W.G. Steele, Experimentation and Uncertainty Analysis for Engineers, $2^{nd}$ Ed., John Wiley & Sons (1999)