• 제목/요약/키워드: and resonance

검색결과 10,515건 처리시간 0.043초

Extraforaminal Extrusion of Intervertebral Disc Misdiagnosed as Neurogenic Tumor: a Case Report

  • Chun, Se-Woong;Park, Young-Seop;Heo, Won;Baek, Kyeonghee;Moon, Jin Il
    • Investigative Magnetic Resonance Imaging
    • /
    • 제21권2호
    • /
    • pp.109-113
    • /
    • 2017
  • A 55-year-old male presented with dysesthesia of the right anteromedial thigh. A magnetic resonance image revealed a globular mass at the right extraforaminal area of the L3/4 level. Based on the diagnosis of neurogenic tumor, surgical excision was performed. The surgical impression and pathology confirmed extrusion of intervertebral disc. In a retrospective review of the magnetic resonance image, we noticed a fibrillary pattern directed from the intervertebral disc space to the lesion, and disrupted annulus fibrosus and indentation caused by the ring apophysis. We suggest aforementioned features, indicative of intervertebral disc lesions, to be checked when interpreting mass lesions around the intervertebral foramen.

초음파원자현미경 캔틸레버의 동특성 해석과 탄성특성 평가 (Evaluation of Elastic Properties and Analysis of Contact Resonance Frequency of Cantilever for Ultrasonic AFM)

  • 박태성;곽동열;박익근;김정석;장경영
    • 비파괴검사학회지
    • /
    • 제31권2호
    • /
    • pp.174-180
    • /
    • 2011
  • 본 연구에서는 초음파원자현미경을 이용하여 비파괴적인 표면탄성이미지 분석과 나노표면에서의 기계적 물성 평가를 연구하였다. 이를 위해 접촉역학 특성에 따른 캔틸레버의 공진주파수 변화를 이론적으로 해석하고 실험적으로 측정하였다. 스프링-질량 모델과 Herzian 이론을 이용하여 계산한 이론적인 접촉공천주파수는 초음파원자현미경 캔틸레버의 실험적인 접촉 공진주파수의 변화와 매우 유사하였다. 결과적으로, 초음파원자현미경의 표면 높이 이미지와 진폭이미지를 성공적으로 얻을 수 있었고 진폭신호를 통하여 시료표면에서의 탄성특성을 정성적으로 평가하였다.

Resonance Characteristic Improvement of ZnO-Based FBAR Devices Fabricated on Thermally Annealed Bragg Reflectors

  • Yim, Mun-Hyuk;Kim, Dong-Hyun;Linh Mai;Giwan Yoon
    • Journal of information and communication convergence engineering
    • /
    • 제1권4호
    • /
    • pp.199-204
    • /
    • 2003
  • In this paper, we present the thermal annealing effects of the W/$SiO_2$ multi-layer reflectors in ZnO-based FBAR devices with cobalt (Co) electrodes in comparison with those with aluminum (Al) electrodes. Various thermal annealing conditions have been implemented on the W/$SiO_2$ multi-layer reflectors formed on p-type (100) silicon substrates. The resonance characteristics could be significantly improved due to the thermal annealing and were observed to depend strongly on the annealing conditions applied to the reflectors. Particularly, the FBAR devices with the W/$SiO_2$ multi- layer reflectors annealed at $400^{\circ}C$/30min have shown superior resonance characteristics in terms of return loss and quality-factor (Q-factor). In addition, the use of Co electrodes has resulted in further improvement of the resonance characteristics as compared with the Al electrodes. As a result, the combined use of both the thermal annealing and Co electrodes seems very useful to more effectively improve the resonance characteristics of the FBAR devices with the W/$SiO_2$ multi-layer reflectors.

음향 공명 제거 및 과도 상태 전류를 제한시킨 고출력 메탈 헬라이드 램프용 전자식 안정기 설계 (The Electronic Ballast Design of Acoustic Resonance Free and Transient Over Current Limit for High Power MHL)

  • 김기남;박종연;최영민
    • 전기학회논문지
    • /
    • 제59권5호
    • /
    • pp.904-911
    • /
    • 2010
  • This paper presents the design of acoustic resonance free and over current limit during transient state consideration electronic ballast for 1.5kW Metal-Halide Lamp(MHL) that employs frequency modulation (FM) technique. The proposed ballast consists of a Full-Bridge(FB) rectifier, a passive power factor correction (PFC) circuit, a full-bridge inverter, an ignitor using LC resonance and a control circuit for frequency modulation. The frequency modulation technique is the most effective solution to eliminate acoustic resonance among other technique. It spreads power spectrum of lamp to reduce the supplied power spectrum under the energy level of eigen-value frequency. Moreover, the proposed ballast is simple and cost effective above conventional ballast. A new PFC circuit is proposed which combines with LCD type and PCSR filter. A new PFC circuit has higher PF and lower THD than conventional LCD type and secure high reliability. Finally, to protected switching components in transient state, the surge current into ballast is limited by increase the switching frequency. Performance of the proposed ballast was validated through computer simulation using Pspice, experimentation and by applying it to an electronic ballast for a prototype 1.5kW MHL.

27Al and 87Rb Nuclear Magnetic Resonance Study of the Relaxation Mechanisms of RbAl(CrO4)2·2H2O Single Crystals

  • Kim, Jae Sung;Lim, Ae Ran
    • 한국자기공명학회논문지
    • /
    • 제16권2호
    • /
    • pp.111-121
    • /
    • 2012
  • The spin-lattice relaxation times, $T_1$, and spin-spin relaxation times, $T_2$, of the $^{27}Al$ and $^{87}Rb$ nuclei in $RbAl(CrO_4)_2{\cdot}2H_2O$ crystals were investigated. The presence of only one resonance line for the $^{27}Al$ nuclei indicates that the results in a dynamical averaging of the crystal electric field that produces a cubic symmetry field. The changes in the temperature dependence of $T_1$ are related to variations in the symmetry of the octahedra of water molecules surrounding $Al^+$ and $Rb^+$. The $T_1$ values for the $^{27}Al$ and $^{87}Rb$ nuclei are different due to differences in the local environments of these ions. We also compared these $^{27}Al$ and $^{87}Rb$ NMR results with those obtained for $RbAl(CrO_4)_2{\cdot}2H_2O$ crystals. The relaxation mechanisms of $RbAl(XO_4)_2{\cdot}nH_2O$ (X=Cr and S) crystals are characterized by completely different NMR behaviors.

레이저 관성항법장치에서 링레이저 자이로 디더 운동에 의한 가속도계 공진이 자체 정렬/항법 성능에 미치는 영향 분석 (Self-Alignment/Navigation Performance Analysis in the Accelerometer Resonance State Generated by Dither Motion of Ring Laser Gyroscope in Laser Inertial Navigation System)

  • 김천중;임경아;김선아
    • 한국군사과학기술학회지
    • /
    • 제24권6호
    • /
    • pp.577-590
    • /
    • 2021
  • In this paper, we theoretically analyzed the self-alignment/navigation performance in the accelerometer resonance state generated by dither motion of ring laser gyroscope in LINS and verified it through simulation. As a result of analysis, it is confirmed that the amplitude of the accelerometer measurement amplified in the accelerometer resonance state is decreased in the process of sampling per the navigation calculation period and that frequency is changed by the aliasing effect too. It was also analysed that the attitude error in self-alignment is determined by the amplitude/frequency of the accelerometer measurement, the gain of the self-alignment loop, and the velocity and position error in the navigation is determined by the amplitude/frequency/phase error of the accelerometer measurement. This analysis and simulation results show that the self-alignment and navigation performance is not be degraded only when the amplification factor of the accelerometer measurement in the accelerometer resonance state is 3 or less

Resonance frequency and stability of composite micro/nanoshell via deep neural network trained by adaptive momentum-based approach

  • Yan, Yunrui
    • Geomechanics and Engineering
    • /
    • 제28권5호
    • /
    • pp.477-491
    • /
    • 2022
  • In the present study, the effects of thermal loading on the buckling and resonance frequency of graphene platelets (GPL) reinforced nano-composites are examined. Functionally graded (FG) material properties are considered in thickness direction for the thermal responses of the composite. The equivalent material properties are obtained using Halphin-Tsai nano-mechanical model for composite layers. Moreover, the effects of nano-scale sizes are taken into account, employing functionally modified couple stress (FMCS) parameter. In this regard, for the first time, it is demonstrated that at certain values of GPL weight fraction, thermal buckling occurs. In obtaining results of vibrational behavior, both analytical solution and deep neural network (DNN) methods are used. The DNN method needs low computational costs to predict the resonance behavior. A comprehensive parametric study is conducted to indicate the effects of several geometrical, material, and loading conditions on the vibrational and buckling behavior of cylindrical shell structures made of GPL-nanocomposites. It is shown that the effect of temperature change on the occurrence of buckling is vital while it has a negligible impact on the resonance frequency of the structure. Moreover, the size-dependency of the results is demonstrated, and it cannot be neglected in nano-scales.

Resonant response of spar-type floating platform in coupled heave and pitch motion

  • Choi, E.Y.;Cho, J.R.;Jeong, W.B.
    • Structural Engineering and Mechanics
    • /
    • 제65권5호
    • /
    • pp.513-521
    • /
    • 2018
  • In this paper, the resonance response of spar-type floating platform in coupled heave and pitch motion is investigated using a CPU time-effective numerical method. A coupled nonlinear 2-DOF equation of motion is derived based on the potential wave theory and the rigid-body hydrodynamics. The transient responses are solved by the fourth-order Runge-Kutta (RK4) method and transformed to the frequency responses by the digital Fourier transform (DFT), and the first-order approximation of heave response is analytically derived. Through the numerical experiments, the theoretical derivation and the numerical formulation are verified from the comparison with the commercial software AQWA. And, the frequencies of resonance arising from the nonlinear coupling between heave and pitch motions are investigated and justified from the comparison with the analytically derived first-order approximation of heave response.

Cobalt (Co) Electrode FBAR Devices Fabricated on Seven-Layered Bragg Reflectors and Their Resonance Characteristics

  • Mai Linh;Yim, Mun-Hyuk;Yoon, Gi-Wan;Kim, Dong-Hyun
    • Journal of information and communication convergence engineering
    • /
    • 제1권3호
    • /
    • pp.129-132
    • /
    • 2003
  • In this paper, cobalt (Co)-electrode FBAR devices fabricated on seven-layered Bragg Reflectors are presented along with their resonance characteristics. ZnO films are used as the resonating material in FBAR devices where the Co electrode is 3000${\AA}$ thick. All processes are preformed in an RF magnetron sputtering system. As a result of characterization, the resonance characteristics are observed to depend strongly on the quality of ZnO film and Bragg Reflectors. In addition, the FBAR devices with W/$SiO_2$ reflectors show good resonance characteristics in term of return loss and quality-factor (Q-factor).