• 제목/요약/키워드: amplitude modulation

검색결과 611건 처리시간 0.038초

Modulation of $Ca^{2+}-Activated$ Potassium Channels by cGMP-Dependent Signal Transduction Mechanism in Cerebral Arterial Smooth Muscle Cell of the Rabbit

  • Han, Jin;Kim, Na-Ri;Lee, Kwang-Bok;Kim, Eui-Yong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제4권6호
    • /
    • pp.445-453
    • /
    • 2000
  • The present investigation tested the hypothesis that the activation of protein kinase G (PKG) leads to a phosphorylation of $Ca^{2+}-activated$ potassium channel $(K_{Ca}\;channel)$ and is involved in the activation of $K_{Ca}$ channel activity in cerebral arterial smooth muscle cells of the rabbit. Single-channel currents were recorded in cell-attached and inside-out patch configurations of patch-clamp techniques. Both molsidomine derivative 3-morpholinosydnonimine-N-ethylcarbamide $(SIN-1,\;50\;{\mu}M)$ and 8-(4-Chlorophenylthio)-guanosine-3',5'-cyclic monophosphate $(8-pCPT-cGMP,\;100\;{\mu}M),$ a membrane-permeable analogue of cGMP, increased the $K_{Ca}$ channel activity in the cell-attached patch configuration, and the effect was removed upon washout of the drugs. In inside-out patches, single-channel current amplitude was not changed by SIN-1 and 8-pCPT-cGMP. Application of ATP $(100\;{\mu}M),$ cGMP $(100\;{\mu}M),$ ATP+cGMP $(100\;{\mu}M\;each),$ PKG $(5\;U/{\mu}l),$ ATP $(100\;{\mu}M)+PKG\;(5\;U/{\mu}l),$ or cGMP $(100\;{\mu}M)+PKG\;(5\;U/{\mu}l)$ did not increase the channel activity. ATP $(100\;{\mu}M)+cGMP\;(100\;{\mu}M)+PKG\;(5\;U/{\mu}l)$ added directly to the intracellular phase of inside-out patches increased the channel activity with no changes in the conductance. The heat-inactivated PKG had no effect on the channel activity, and the effect of PKG was inhibited by 8-(4-Chlorophenylthio)-guanosine-3',5'-cyclic monophosphate, Rp-isomer $(Rp-pCPT-cGMP,\;100\;{\mu}M),$ a potent inhibitor of PKG or protein phosphatase 2A (PP2A, 1 U/ml). In the presence of okadaic acid (OA, 5 nM), PP2A had no effect on the channel activity. The $K_{Ca}$ channel activity spontaneously decayed to the control level upon washout of ATP, cGMP and PKG, and this was prevented by OA (5 nM) in the medium. These results suggest that the PKG-mediated phosphorylations of $K_{Ca}$ channels, or some associated proteins in the membrane patch increase the activity of the $K_{Ca}$ channel, and the activation may be associated with the vasodilating action.

  • PDF

생쥐 소장 카할세포의 내향성 향도잡이 전압에 미치는 내소산의 억제효과에 관한 연구 (Inhibitory Effects of Naeso-san on Pacemaker Potentials in Interstitial Cells of Cajal of Murine Small Intestine)

  • 홍누리;안태석;박현수;채한;권영규;김병주
    • 동의생리병리학회지
    • /
    • 제28권6호
    • /
    • pp.630-635
    • /
    • 2014
  • The purpose of this study was to investigate the effects of Naeso-san in interstitial cells of Cajal (ICCs) in murine small intestine. First, we isolated ICCs from murine small intestine. After that, we cultured these cells for 1 days. The patch-clamp technique was applied on ICCs that formed network-like structures in culture (1 days). Spontaneous rhythms were routinely recorded from cultured ICCs under current-clamp conditions, and the ICCs within networks displayed more robust electrical rhythms (pacemaker potentials). To understand the relationship between Naeso-san and pacemaker activity in ICCs, we examined the effects of Naeso-san on pacemaker potentials of ICCs. In current clamp mode (I = 0), the addition of Naeso-san (10 mg/ml - 50 mg/ml) decreased the amplitude and frequency of the pacemaker potentials of ICCs in a dose dependent manner. However, these effects were blocked by intracellular $GDP{\beta}S$, a G-protein inhibitor, and glibenclamide, a specific ATP-sensitive K+ channels blocker. Pretreatment with SQ-22536, an adenylate cyclase inhibitor, did not block the Naeso-san induced effects, whereas pretreatment with ODQ, a guanylate cyclase inhibitor, or L-NAME, an inhibitor of nitric oxide (NO) synthase blocked the Naeso-san induced effects. Our findings provide insight into unraveling the modulation of Naeso-san in pacemaker potentials of ICCs and developing therapeutic agents against gastrointestinal motility disorders.

상진폭 특성을 가지는 새로운 3차원 16진 신호성상도의 설계 (Design of a New 3-D 16-ary Signal Constellation with Constant Envelope)

  • 최재철;강석근
    • 한국정보통신학회논문지
    • /
    • 제15권10호
    • /
    • pp.2149-2156
    • /
    • 2011
  • 본 논문에서는 디지털통신을 위한 새로운 3차원 16진 신호성상도의 설계방법을 제시하고 그 성능을 분석한다. 기존의 성상도와는 달리 새로운 성상도는 모든 신호점들이 구의 표면에 균일하게 분포하므로 상진폭과 대칭적 구조 특성을 동시에 만족한다. 신호성상도의 평균전력을 정규화시킨 경우 제시된 16진 신호성상도는 기존의 비상진폭(non-constant envelope) 성상도들에 비하여 최대 11.4% 가량 증가된 최소 유클리드 거리를 가지는 것으로 나타났다. 이로 인하여 가산성 백색 가우시안잡음 환경에서 제안된 신호성상도가 적용된 디지털 통신시스템의 심볼오율은 기존 성상도를 이용하는 시스템에 비하여 1.2dB 가량 향상됨을 확인할 수 있다. 유클리드 거리 측면에서 최적화된 기존 상진폭 신호성상도에서는 신호점들이 구의 표면에 균일하게 분포하지 않는 반면 새로운 성상도는 3차원 신호공간에서 완전 대칭인 신호점 분포를 가진다. 이와 함께 기존의 성상도에 비하여 제안된 성상도에서는 설계에 요구되는 연산복잡도가 거의 없는 장점도 있다. 따라서 제안된 3차원 16진 신호성상도는 편광편이키잉과 같이 상진폭 특성이 요구되는 디지털 통신시스템에 적합한 것으로 판단된다.

Dual Effect of $H_2O_2$ on the Regulation of Cholecystokinin-induced Amylase Release in Rat Pancreatic Acinar Cells

  • An, Jeong-Mi;Rhie, Jin-Hak;Seo, Jeong-Taeg
    • International Journal of Oral Biology
    • /
    • 제31권4호
    • /
    • pp.127-133
    • /
    • 2006
  • [ $H_2O_2$ ], a member of reactive oxygen species (ROS), is known to be involved in the mediation of physiological functions in a variety of cell types. However, little has been known about the physiological role of $H_2O_2$ in exocrine cells. Therefore, in the present study, the effect of $H_2O_2$ on cholecystokinin (CCK)-evoked $Ca^{2+}$ mobilization and amylase release was investigated in rat pancreatic acinar cells. Stimulation of the acinar cells with sulfated octapeptide form of CCK (CCK-8S) induced biphasic increase in amylase release. Addition of $30\;{\mu}M\;H_2O_2$ enhanced amylase release caused by 10 pM CCK-8S, but inhibited the amylase release induced by CCK-8S at concentrations higher than 100 pM. An ROS scavenger, $10\;{\mu}M$ Mn(III)tetrakis(4-benzoic acid)porphyrin chloride, increased amylase release caused by CCK-8S at concentrations higher than 100 pM, although lower concentrations of CCK-8S-induced amylase release was not affected. To examine whether the effect of $H_2O_2$ on CCK-8S-induced amylase release was exerted via modulation of intracellular $Ca^{2+}$ signaling, we measured the changes in intracellular $Ca^{2+}$ concentration $([Ca^{2+}]_i)$ in fura-2 loaded acinar cells. Although $30\;{\mu}M\;H_2O_2$ did not induce any increase in $[Ca^{2+}]_i$ by itself, it increased the frequency and amplitude of $[Ca^{2+}]_i$ oscillations caused by 10 pM CCK-8S. However, $30\;{\mu}M\;H_2O_2$ had little effect on 1 nM CCK-8S-induced increase in $[Ca^{2+}]_i$. ROS scavenger, 1 mM N-acetylcysteine, did not affect $[Ca^{2+}]_i$ changes induced by 10 pM or 1 nM CCK-8S. Therefore, it was concluded that $30\;{\mu}M\;H_2O_2$ enhanced low concentration of CCK-8S-induced amylase release probably by increasing $[Ca^{2+}]_i$ oscillations while it inhibited high concentration of CCK-8S-induced amylase release.

In0.5(Ga1-xAlx)0.5P/GaAs 이중 이종접합 구조의 Contactless Electroreflectance에 관한 연구 (Contactless Electroreflectance Spectroscopy of In0.5(Ga1-xAlx)0.5P/GaAs Double Heterostructures)

  • 김정화;조현준;배인호
    • 한국진공학회지
    • /
    • 제19권2호
    • /
    • pp.134-140
    • /
    • 2010
  • Metal-organic chemical vapour deposition (MOCVD)법으로 성장된 $In_{0.5}(Ga_{1-x}Al_x)_{0.5}P$/GaAs 이중 이종접합 구조의 특성을 contactless electroreflectance (CER) 분광법으로 조사하였다. CER 측정은 변조전압($V_{ac}$), 온도 및 dc 바이어스 전압($V_{bias}$)의 함수로 수행하였다. 상온에서는 5개의 신호가 관측되었는데, 이 신호들은 각각 GaAs, $In_{0.5}Ga_{0.5}P$, $In_{0.5}(Ga_{0.73}Al_{0.27})_{0.5}P$, $In_{0.5}(Ga_{0.5}Al_{0.5})_{0.5}P$$In_{0.5}(Ga_{0.2}Al_{0.8})_{0.5}P$ 전이에 관련된 것이다. CER 스펙트럼의 온도 의존성으로부터 Varshni 계수 및 평탄인 자를 구하였다. 그리고 인가전압에 따른 신호의 진폭은 순방향 바이어스 전압 인가시 점차로 감소하나, 역방향 바이어스 전압 인가시에는 반대의 경향을 보였다.

영업운행 전동차 객실형광등의 플리커(Flicker) 현상에 관한 분석 연구 (An analysis on Flicker Phenomenon of a Fluorescent lights for the commercial operating EMU)

  • 하종은;한성호;박재홍;이대원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.1240-1246
    • /
    • 2006
  • 일반적으로 전동차 보조전원장치의 출력전원 품질에 영향을 주는 주된 요인으로는 짧은 시간동안의 진폭변조로 인한 전압플리커 현상과 전동차 내부의 공기압축기 및 냉난방 환기장치 등 대용량 전동기의 반복적인 구동 등을 들 수 있다. 본 연구는 전동차내의 형광등의 전원과 관련된 플리커 현상에 대해 내장재 개조 후 형광등 32W와 개조 전 40W를 입력전원(AC220V)의 변동에 따른 광 출력(밝기) 로서 계측 비교하였다. 또한, 전압변동을 유발하는 부하변동의 주된 요인을 파악하기 위해 전동차 운행시간과 운행밀도를 고려하여 플리커 현상을 분석하였다. 연구결과, 개조 후 형광등 32W에 비해 40W 형광등이 입력전원의 변화에 대해 육안인식정도 측면에서는 20.26% 정도 덜 민감하게 반응함을 알 수 있었으며, 심한 플리커가 일어나는 전압의 경우도 19.9%로 더 낮게 측정되었다. 또한, 운행차량의 부하변동 영향에 있어서는 주로 영업차량의 운행밀도가 높고, 이용승객이 많은 혼합시간대에 보조전원장치(SIV)의 출력전압 변동으로 인한 객실형광등 플리커가 발생된다는 사실을 확인할 수 있었다. 더불어, 전동차 이용승객이 육안으로 형광등의 깜박임을 민감하게 느낄 수 있는 가능 주파수대역으로서 $8Hz{\sim}15Hz$ 임을 확인하였다.

  • PDF

남서해역에서 양식되는 방사무늬김(Porphyra yezoensis Ueda)의 Diving-PAM에 의한 광합성 특성 (Photosynthetic Characteristics of Porphyra yezoensis Ueda Measured in situ by Diving Pulse-Amplitude Modulated (PAM) Fluorometry on the Southwestern Coast of the Korean Peninsula)

  • 김정배;이원찬;김형철;최희구;박정임;조윤식;박환희
    • 환경생물
    • /
    • 제30권3호
    • /
    • pp.210-218
    • /
    • 2012
  • 일반적으로 많이 양식되는 방사무늬김(Porphyra yezoensis Ueda)에 대하여 방사무늬김 엽체의 형태적 특성, 탄소 및 질소 성분의 농도, 안정동위원소 비값, 광합성 효율을 방사무늬김 양식이 이루어 지고 있는 남서해역에서 조사를 하였다. 방사무늬김의 형태적 특성에 대해서 살펴보면 평균 엽장은 11.6~16.3 (13.8) cm, 평균 엽폭은 4.6~6.3 (5.4) cm이었고, 단위면적당 방사무늬김 엽체의 평균 엽중량은 $1.1{\sim}2.6(1.86)g\;DW\;m^{-2}$이었다. 단위면적당 Chl a 농도는 2.18~17.77 (평균 9.65) mg DW Chl a $m^{-2}$이었다. 방사무늬김의 탄소 농도는 $201{\sim}317(240)mg\;DW\;g^{-1}$이었고, 질소 농도는 $39.8{\sim}50.0(43.5)mg\;DW\;g^{-1}$이었으며, C/N비는 5.0~6.7 (5.5)이었다. 방사무늬김의 방사성 안정동위원소비 중에서 탄소 안정동위원소 비는 ${\delta}^{13}C$=-25.6‰ 에서 ${\delta}^{13}C$=-24.0‰ (평균 -24.7‰)의 값을 보였고, 질소 안정동위원소 비는 ${\delta}^{15}N$=1.3‰ 에서 ${\delta}^{15}N$=4.1‰ (평균 2.1‰)의 값을 보였다. PAM에 의한 해조류의 광합성 특성은 광합성 활동의 지시자로서 사용될 수 있다. 우리는 Diving-PAM을 이용하여 각 정점 해조류인 방사무늬김의 광합성율을 분석하였다. 최대양자수율은 0.46~0.55 (평균 0.52)로서 최대 양자수율의 변동은 정점간 큰 차이는 없었다. 최대상대전자전달률은 4.71~5.84 (평균 5.33) ${\mu}mol\;electrons\;m^{-2}\;s^{-1}$ 로서 최대양자수율과 비슷한 분포를 보였다. 기울기 (${\alpha}$)는 0.027~0.045 (평균 0.036)을 보였고, 전자전달을 위한 포화광은 지역에 따라서 일부 차이를 보였으나 $139{\sim}180(156){\mu}mol\;photons\;m^{-2}\;s^{-1}$이었다. 남서해역 방사무늬김 엽체의 탄소 및 질소 농도와 광합성 효율은 지역에 따른 큰 차이는 보이지 않았다. 광합성 특성은 낮은 최대양자수율과 최대 상대전자전달률로 인한 낮은 광합성 효율이 나타났다.

마이크로웨이브 레이더를 이용한 수역관측에 있어서의 수치 시뮬레이션 이용 (Use of Numerical Simulation for Water Area Observation by Microwave Radar)

  • 요시다타케로;임창규
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제15권3호
    • /
    • pp.208-218
    • /
    • 2012
  • 수면에서의 마이크로웨이브 후방산란 수치 시뮬레이션 기법을 개발하였다. 수치 시뮬레이션은 수조나 실해역 실험의 대체수단으로서, 수면에서의 마이크로웨이브 후방산란 과정의 이해, 마이크로웨이브 레이더를 이용한 수면 관측시스템과 관측방법의 평가에 이용된다. 이 논문에서는 다양한 수면 조건에 대한 수치 시뮬레이션의 적용 예와 수치 시뮬레이션의 유용성에 대해서 기술하였다. 적용 예로서, 고정안테나 펄스 도플러 레이더의 1) 도플러 이미지, 2) 레이더 조사폭 영향, 3) 하천 수위 관측과, 4) 합성 개구 레이더 (SAR) 의 해면 이미지를 보여준다. 해면으로부터의 마이크로웨이브 후방산란 수치 시뮬레이션을 통하여, 1) 파랑계측에 있어서 펄스 도플러 레이더의 주파수 변조 이미지가 진폭 변조 이미지에 비해서 유용함을 보였다. 2) 연속파 레이더를 이용한 파랑계측에 있어서의 레이더 해면 조사폭의 영향에 대한 Rheem[2008]의 보고와 관련해, 레이더 조사폭이 도플러 스펙트럼에 미치는 영향을 조사하여, 파랑계측에 적합한 레이더의 조사 조건을 보였다. 3) 펄스 도플러 레이더를 이용한 해면 조위관측 알고리듬을 하천의 유속과 수위 추정에 응용함에 있에서, 알고리듬의 적용성과 계측성능을 평가했다. 4) SAR 이미지 생성 메케니즘의 이해와 SAR 이미지를 이용한 해면 관측 알고리듬의 평가를 위해, 수치 시뮬레이션을 이용하여 해면의 SAR 이미지를 생성하였다.

2.7Gbps/1.62Gbps DisplayPort 송신기용 PLL 및 확산대역 클록 발생기의 설계 (A Design of PLL and Spread Spectrum Clock Generator for 2.7Gbps/1.62Gbps DisplayPort Transmitter)

  • 김영신;김성근;부영건;허정;이강윤
    • 대한전자공학회논문지SD
    • /
    • 제47권2호
    • /
    • pp.21-31
    • /
    • 2010
  • 본 논문에서는 DisplayPort용 전자기기 또는 클록 발생을 요구하는 다양한 회로에서 발생 할 수 있는 전자방해(EMI) 현상을 줄일 수 있는 위상 동기 루프와 확산 대역 클록 발생기를 구현 하였다. 이 시스템은 기본적으로 송신용 위상 동기 루프와 확산 대역 클록 발생기 구현을 위한 전하펌프2 와 기준주파수 분주기 등으로 구성된다. 본 논문에서는 2.7Gbps/1.62Gbps DisplayPort 응용 회로에 적합 하도록 10개의 다중 위상 신호를 출력 할 수 있는 270MHz/162MHz 듀얼 모드 위상 동기 루프를 설계 하였고 추가적으로 1.35GHz/810MHz의 위상 동기 루프를 설계하여 지터를 크게 감소시킬 수 있는 구조를 제안하였다. 270MHz/162MHz 위상 동기 루프와 5:1 시리얼라이저 2개, 그리고 1.35GHz 위상 동기 루프와 2:1 시리얼라이저를 연동함으로써 지터 성분을 크게 줄일 수 있다. 위상 동기 루프에서 사용 된 주파수 전환 다중위상 전압제어 발진기와 더불어 DisplayPort 규격에 맞는 주파수 전환이 가능 하도록 분주기를 공유하고 50% duty ratio를 보장할 수 있는 주파수 분주기 구조를 제안 하였다. 또한, 지터를 줄이기 위해서 출력전류 오차를 크게 줄일 수 있는 전하펌프 구조를 제안 하였다. 0.13 um CMOS 공정을 사용하여 설계 하였으며, 270MHz/162MHz PLL의 칩 면적은 $650um\;{\times}\;500um$ 이고, 1.35GHz/810MHz PLL의 칩 면적은 $600um\;{\times}\;500um$ 이다. 270MHz/162MHz 위상 동기 루프 전압제어 발진기의 조절 범위는 330MHz이고, 위상 잡음은 1MHz 오프셋에서 -114cBc/Hz, 확산대역 클록 발생기의 확산 진폭도 는 0.5%이고, 변조 주파수는 31kHz이다. 전체 전력 소모는 48mW이다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF