• Title/Summary/Keyword: alternating method

Search Result 434, Processing Time 0.023 seconds

Development of Titanium Metal Surface Anodizing Equipment (티타늄 금속 표면 양극산화장치 개발)

  • Yang, Keun-Ho;Min, Byung-Woon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.9
    • /
    • pp.1307-1312
    • /
    • 2013
  • In this paper, alkaline or acidic solution, in particular the principle of electrolysis to oxidize the metal surface to form a device isolation film is developed. In the past, mainly in the form of pulse voltage is applied to the anode only a unipolar method, but in this paper by using the H-bridge to the amount of the positive (+) voltage and the negative supply voltage, alternating voltage polarity devices were fabricated according to the characteristics of metal specimens with different electrical conditions to form an oxide film on the device was developed. Supply current variable was used for the PWM modulation, (+) and (-) polarity change of the H-bridge bipolar pulse voltage to supply the was that. As a result, a more uniform pores with unipolar film was formed.

A Evaluation on the Characteristics of Electrical Power System for the Station Blackout Events (원전 완전전원상실 사고에 대한 전력계통 특성평가)

  • Oh, S.H.;Zoo, O.P.;Ryu, B.H.;Chung, Y.H.;Kim, D.I.;Lim, C.H.;Kim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.140-143
    • /
    • 1993
  • Station Blackout(SBO) event means the complete loss of alternating current(AC) electrical power to the essential & nonessential switchgear buses in a nuclear power plants. Since many safety systems in nuclear power plants depend upon alternative current power, the SBO event could be an important contributor to damage of reactor core. Therefore, the SBO events have been considered as a very important safety issues in a nuclear power plants. In this paper, as evaluating the design characteristics of offsite & emergency power systems, an acceptable minimum SBO duration is calculated. And it is presented that the design method for alternative AC(AAC) sources to cope with the SBO events.

  • PDF

A Study on Characterization of Thick Film used as Superconducting Fault Current Limiter (고온 초전도 전류제한기용 후막의 특성 연구)

  • 조동언;박경국;김동원;정길도;한병성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.12
    • /
    • pp.1139-1145
    • /
    • 1998
  • In this paper, to fabricate a superconducting fault current limiter(FCL) of thick film type, $YBa_2Cu_3O_X superconducting thick films were fabricated by surface diffusion process using the screen printing method. Powder mixture of $3BaCuO_2$+2CuO was screen printed on $Y_2BaCuO_5$(d=15mm). And critical current densities of the thick films were observed as the sintering temperature(92$0^{\circ}C$~95$0^{\circ}C$) and holding time(2h~10h). Based on experimental data, the thick films for superconducting FCL were sintered at $940^{\circ}C$ in 2 hours. The superconducting FCL with a current limiting area of 1mm wide and 66mm long was prepared on $Y_2BaCuO_5$ substrate. To measure the characterization of the fabricated FCL, an alternating voltage (60Hz) was applied to the FCL in 77K liquid nitrogen. At an applied voltage of 4V, the FCL was limited from 20A into 0.6A not farther than 0.5ms.

  • PDF

Brushless DC Motor Electromagnetic Torque Estimation with Single-Phase Current Sensing

  • Cham, Chin-Long;Samad, Zahurin Bin
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.866-872
    • /
    • 2014
  • The purpose of this paper was to find an effective method for measuring electromagnetic torque produced by a brushless DC motor with single-phase current sensing in real-time. A torque equation is derived from the theory of brushless DC motor. This equation is then validated experimentally with a motor dynamometer. A computer algorithm is also proposed to implement the electromagnetic torque estimation equation in real-time. Electromagnetic torque is a linear function of phase current. Estimating the electromagnetic torque in real-time using single-phase current is not appropriate with existing equations, however, because of the rectangular alternating-pulse nature of the excitation current. With some mathematical manipulation to the existing equations, the equation derived in this paper overcame this limitation. The equation developed is simple and so it is computationally efficient, and it takes only motor torque constant and single-phase current to evaluate the electromagnetic torque; no other parameters such as winding resistances, inductances are needed. The equation derived is limited to the three-phase brushless DC motor. It can, however, easily be extended to the multiphase brushless DC motor with the technique described in this paper.

A Techno-Economic Feasibility Analysis on LVDC Distribution System for Rural Electrification in South Korea

  • Afamefuna, David;Chung, Il-Yop;Hur, Don;Kim, Ju-Yong;Cho, Jintae
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1501-1510
    • /
    • 2014
  • Low voltage direct current (LVDC) distribution system is a suitable techno-economic candidate which can create an innovative solution for distribution network development with respect to rural electrification. This research focuses on the use of LVDC distribution system to replace some of KEPCO's existing traditional medium voltage alternating current (MVAC) distribution network for rural electrification in South Korea. Considering the technical and economic risks and benefits involved in such project, a comparative techno-economic analysis on the LVDC and the MVAC distribution networks is conducted using economic assessment method such as the net present value (NPV) on a discounted cash flow (DCF) basis as well as the sensitivity analysis technique. Each would play a role in an economic performance indicator and a measure of uncertainty and risk involved in the project. In this work, a simulation model and a computational tool are concurrently developed and employed to aid the techno-economic analysis, evaluation, and estimation of the various systems efficiency and/or performance.

A Study on Prediction of Treeting Breakdown in XLPE Cable According to Method of Acoustic Emission Detection (음향방출 계측법에 따른 가교폴리에틸렌 케이블의 트리잉 파괴 예지에 관한 연구)

  • 김재환;박재준
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.4
    • /
    • pp.26-33
    • /
    • 1993
  • The acoustic emission automatic detection system is developed to observe tree deterioration phenomena. Applying an alternating voltage of 15(kVnns) toXLPE tree specimens, many pulses of small amplitude are detected when the bush type tree developes branch type and a few pulses of high amplitude prcxluced as branch type propagated to bush type tree. Therefore, it is known that pulses having small amplitude operates as a destructive factor. It is observed that the skewness of the amplitude and the number of average pulses as distribution tendency of three dimension are characteristic quantity of AE pulses. As the trajectory of skewness is farther from the origin on the S-plane, it is more likely to breakdown.

  • PDF

Characteristics and Measurement Method of the Underwater Electromagnetic Signature Emitted from a Naval Ship (함정 발생 수중 전자기장 신호의 특성 및 측정 기법)

  • Yang, Chang-Seob;Chung, Hyun-Ju;Shin, Seung-Je
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.11-19
    • /
    • 2006
  • The underwater electromagnetic signatures of a naval ship are mainly generated from three sources which are the permanent and induced magnetic field in the ship's hull and other ferrous components, the cathodic current electromagnetic field established by the Impressed Current Cathodic Protection(ICCP) system or the Sacrificial Anode and the stray electromagnetic fields generated by onboard equipment. These signatures can be minimized by certain design methods or installation of signature reduction equipment. In this paper, we represented the characteristic of the underwater electromagnetic signature and the signature reduction techniques for a naval ship. Also, we measured the electromagnetic field changes emitted from the real ship using the Electric and Magnetic field Measurement System(EMMS). We found that the underwater electromagnetic signature for a naval ship can be used as input or trigger signal in a surveillance system and an influence mine.

Loss Analysis and Air-Cooled Design for a Cascaded Electrical Source Transmitter

  • Xue, Kai-Chang;Wang, Shuang;Lin, Jun;Li, Gang;Zhou, Feng-Dao
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.530-543
    • /
    • 2015
  • Air-cooling method is adopted on the basis of the requirements for the thermal stability and convenient field use of an electrical source transmitter. The power losses of the transmitter are determined after calculating the losses of the alternating current (AC)-direct current (DC) power supply, the constant-current circuit, and the output circuit. According to the analysis of the characteristics of a heat sink with striped fins and a fan, the engineering calculation expression of the Nusselt number and the design process for air-cooled dissipation are proposed. Experimental results verify that the error between calculated and measured values of the transmitter losses is 12.2%, which meets the error design requirements of less than 25%. Steady-state average temperature rise of the heat sink of the AC-DC power supply is $22^{\circ}C$, which meets the design requirements of a temperature rise between $20^{\circ}C$ and $40^{\circ}C$. The transmitter has favorable thermal stability with 40 kW output power.

Characteristics of the Photoinduced Anisotropy(PA) in Ag/AsGeSeS Multilayer Thin Films (Ag/AsGeSeS 다층박막의 광유기 이방성(PA) 특성)

  • Yeo, Cheol-Ho;Na, Su-Woong;Shin, Kyung;Park, Jeong-Il;Chung, Hong-Bay
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.2
    • /
    • pp.144-150
    • /
    • 2003
  • The chalcogenide glasses of thin films have the superior property of photoinduced anisotrophy(PA). In this study, we observed the linear dichroism using the irradiation with Polarized He-Ne laser light in the Ag/As$_{40}$ Ge$_{10}$Se$_{15}$ S$_{35}$ multi-layer. Multilayer structures were formed by alternating metal(Ag) and chalcogenide(As$_{40}$ Ge$_{10}$Se$_{15}$ S$_{35}$) thin film. The Ag Polarized photodoping result in reducing the time of saturation anisotropy and increasing the sensitivity of linearly anisotropy intensity As the results, the Ag polarized photodoping will be have a capability of new method that suggests more improvement of photoinduced anisotropy property in the thin films of chalcogenide.ogenide.ide.

H2S Micro Gas Sensor Based on a SnO2-CuO Multi-layer Thin Film

  • Kim, Sung-Eun;Choi, Woo-Chang
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.1
    • /
    • pp.27-30
    • /
    • 2012
  • This paper proposes a micro gas sensor for measuring $H_2S$ gas. This is based on a $SnO_2$-CuO multi-layer thin film. The sensor has a silicon diaphragm, micro heater, and sensing layers. The micro heater is embedded in the sensing layer in order to increase the temperature to an operating temperature. The $SnO_2$-CuO multi layer film is prepared by the alternating deposition method and thermal oxidation which uses an electron beam evaporator and a thermal furnace. To determine the effect of the number of layers, five sets of films are prepared, each with different number of layers. The sensitivities are measured by applying $H_2S$ gas. It has a concentration of 1 ppm at an operating temperature of $270^{\circ}C$. At the same total thickness, the sensitivity of the sensor with multi sensing layers was improved, compared to the sensor with one sensing layer. The sensitivity of the sensor with five layers to 1 ppm of $H_2S$ gas is approximately 68%. This is approximately 12% more than that of a sensor with one-layer.