• Title/Summary/Keyword: alpha-dual

Search Result 140, Processing Time 0.024 seconds

DSP BASED CONTROL OF HIGH POWER STATIC VAR COMPENSATOR USING NOVEL VECTOR PRODUCT PHASE LOCKED LOOP (새로운 벡터적 PLL를 이용한 대용량 무효전력 보상기(SVC)의 DSP 제어)

  • Jung, Gu-H.;Cho, Guk-C.;Chae, Cyun;Cho, Gyu-H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.262-264
    • /
    • 1996
  • This paper presents a new dual loop control using novel vector phase locked loop(VP-PLL) for a high power static var compensator(SVC) with three-level GTO voltage source inverter(VSI). Through circuit DQ-transformation, a simple dq-axis equivalent circuit is obtained. From this, DC analysis is carried out to obtain maximum controllable phase angle ${\alpha}_{max}$ per unit current between the three phase source and the switching function of inverter, and AC open-loop transfer function is given. Because ${\alpha}_{max}$ becomes small in high power SVC, this paper proposes VP-PLL for more accurate $\alpha$-control. As a result, the overall control loop has dual loop structure, which consists of inner VP-PLL for synchronizing the phase angle with source and outer Q-loop for compensating reactive power of load. Finally, the validity of the proposed control method is verified through the experimental results.

  • PDF

Function of the Tethered rec-eCG in Rat and Equine Receptors

  • Park, Jong-Ju;Jargal, Naidansuren;Yoon, Jong-Taek;Min, Kwan-Sik
    • Reproductive and Developmental Biology
    • /
    • v.33 no.4
    • /
    • pp.229-236
    • /
    • 2009
  • The glycoprotein hormone family represents a class of heterodimers, that includes the placental hormone equine chorionic gonadotropin (eCG) and the anterior pituitary hormones- follitropin (FSH), lutropin (LH), and thyrotropin (TSH). The 4 hormones are heterodimers, with a common $\alpha$-subunit and unique $\beta$-subunits. eCG is the most heavily glycosylated of the known pituitary and placental glycoprotein hormones. Recent observations using single chain glycoprotein hormone analogs in which, the $\beta$-and $\alpha$-subunits are linked, implied that heterodimeric-like quaternary configuration is not a prerequisite for receptor/signal transduction. To study the function and signal transduction of tethered rec-eCG, a single chain eCG molecule was constructed and rec-eCG protein was produced. Molecular mass of the single chain is about 45 kDa. All mice were ovulated by tethered rec-eCG treatment. The dual activity of tethered rec-eCG was determined in receptor cell lines of nonequid species; in fact, this dual activity was proven in species other than horse. Tethered rec-eCG in equids does not bind to FSH receptors, suggesting that eCG is primarily an LH-like hormone in the horse. Taken together, these data suggest that tethered rec-eCG has dual activity in nonequid species in vitro. However, it has only LH-like activity in equid species in vitro.

Effects of Stability and Volume Fraction of Retained Austenite on the Tensile Properties for Q&P and AM Steels (Q&P와 AM강의 잔류오스테나이트 분율과 안정도에 따른 인장특성 거동)

  • Byun, Sang-Ho;Oh, Chang-Suk;Nam, Dae-Geun;Kim, Young-Seok;Kang, Nam-Hyun;Cho, Kyung-Mox
    • Korean Journal of Materials Research
    • /
    • v.19 no.6
    • /
    • pp.305-312
    • /
    • 2009
  • The effects of Quenching and Partitioning (Q&P) and Annealed Martensite (AM) heat treatment on the microstructure and tensile properties were investigated for 0.24C-0.5Si-1.5Mn-1Al steels. The Q&P steels were annealed at a single phase ($\gamma$) or a dual phase (${\gamma}+{\alpha}$), followed by quenching to a temperature between $M_s$ and $M_f$. Then, enriching carbon was conducted to stabilize the austenite through the partitioning, followed by water quenching. The AM steels were intercritically annealed at a dual phase (${\gamma}+{\alpha}$) temperature and austempered at $M_s$ and $M_s{\pm}50^{\circ}C$, followed by cooling in oil quenching. The dual phase Q&P steels showed lower tensile strength and yieldyield strength than those of the single phase Q&P steels, and tThe elongation for the dual phase Q&P steel was partitioning 100s higher than that of that for the single phase Q&P steels as the partitioning time was less than 100s up to partitioning 100s. For AM steels, the tensile/yield strength decreased and the total elongation increased as the austempering temperature increased. The stability of the retained austenite controlled the elongation for Q&P steels and the volume fraction of the retained austenite controlled the elongation for AM steels.

WEAK AND STRONG CONVERGENCE TO COMMON FIXED POINTS OF NON-SELF NONEXPANSIVE MAPPINGS

  • Su, Yongfu;Qin, Xiaolong
    • Journal of applied mathematics & informatics
    • /
    • v.24 no.1_2
    • /
    • pp.437-448
    • /
    • 2007
  • Suppose K is a nonempty closed convex nonexpansive retract of a real uniformly convex Banach space E with P as a nonexpansive retraction. Let $T_1,\;T_2\;and\;T_3\;:\;K{\rightarrow}E$ be nonexpansive mappings with nonempty common fixed points set. Let $\{\alpha_n\},\;\{\beta_n\},\;\{\gamma_n\},\;\{\alpha'_n\},\;\{\beta'_n\},\;\{\gamma'_n\},\;\{\alpha'_n\},\;\{\beta'_n\}\;and\;\{\gamma'_n\}$ be real sequences in [0, 1] such that ${\alpha}_n+{\beta}_n+{\gamma}_n={\alpha}'_n+{\beta'_n+\gamma}'_n={\alpha}'_n+{\beta}'_n+{\gamma}'_n=1$, starting from arbitrary $x_1{\in}K$, define the sequence $\{x_n\}$ by $$\{zn=P({\alpha}'_nT_1x_n+{\beta}'_nx_n+{\gamma}'_nw_n)\;yn=P({\alpha}'_nT_2z_n+{\beta}'_nx_n+{\gamma}'_nv_n)\;x_{n+1}=P({\alpha}_nT_3y_n+{\beta}_nx_n+{\gamma}_nu_n)$$ with the restrictions $\sum^\infty_{n=1}{\gamma}_n<\infty,\;\sum^\infty_{n=1}{\gamma}'_n<\infty,\; \sum^\infty_{n=1}{\gamma}'_n<\infty$. (i) If the dual $E^*$ of E has the Kadec-Klee property, then weak convergence of a $\{x_n\}$ to some $x^*{\in}F(T_1){\cap}{F}(T_2){\cap}(T_3)$ is proved; (ii) If $T_1,\;T_2\;and\;T_3$ satisfy condition(A'), then strong convergence of $\{x_n\}$ to some $x^*{\in}F(T_1){\cap}{F}(T_2){\cap}(T_3)$ is obtained.

OPTIMALITY AND DUALITY IN NONDIFFERENTIABLE MULTIOBJECTIVE FRACTIONAL PROGRAMMING USING α-UNIVEXITY

  • Gupta, Rekha;Srivastava, Manjari
    • Journal of applied mathematics & informatics
    • /
    • v.32 no.3_4
    • /
    • pp.359-375
    • /
    • 2014
  • In this paper, a multiobjective nondifferentiable fractional programming problem (MFP) is considered where the objective function contains a term involving the support function of a compact convex set. A vector valued (generalized) ${\alpha}$-univex function is defined to extend the concept of a real valued (generalized) ${\alpha}$-univex function. Using these functions, sufficient optimality criteria are obtained for a feasible solution of (MFP) to be an efficient or weakly efficient solution of (MFP). Duality results are obtained for a Mond-Weir type dual under (generalized) ${\alpha}$-univexity assumptions.

MULTIOBJECTIVE SECOND-ORDER NONDIFFERENTIABLE SYMMETRIC DUALITY INVOLVING (F, $\alpha$, $\rho$, d)-CONVEX FUNCTIONS

  • Gupta, S.K.;Kailey, N.;Sharma, M.K.
    • Journal of applied mathematics & informatics
    • /
    • v.28 no.5_6
    • /
    • pp.1395-1408
    • /
    • 2010
  • In this paper, a pair of Wolfe type second-order nondifferentiable multiobjective symmetric dual program over arbitrary cones is formulated. Weak, strong and converse duality theorems are established under second-order (F, $\alpha$, $\rho$, d)-convexity assumptions. An illustration is given to show that second-order (F, $\alpha$, $\rho$, d)-convex functions are generalization of second-order F-convex functions. Several known results including many recent works are obtained as special cases.

Standard Calibration for Broadband and Narrowband Filters of KHAO 0.4 m Telescope

  • Ahn, Hojae;Jeong, Inhwan;Paek, Gregory S.H.;Lee, Sumin;Kim, Changgon;Pak, Soojong;Shim, Hyunjin;Im, Myungshin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.76.1-76.1
    • /
    • 2021
  • Maemi Dual Field Telescope System (MDFTS) is a dual telescope system located at Kyung Hee University. The system consists of 0.4 m telescope and 0.1 m telescope for wide-field observation. The 0.4 m telescope provides photometric observation which covers a field of view of 21'×16'. It has been used for various purposes with Johnson-Cousins UBVRI broadband filter system, e.g., SomangNet and Intensive Monitoring Survey of Nearby Galaxies. In this poster, we present the standard calibration result for our broadband filter system. Also, we suggest a new usage of the KHAO 0.4m telescope which is narrowband photometry by demonstrating the standard calibration of H-alpha filter. For flux calibration, not only R filter but also V filter is used for compensating the central wavelength discrepancy between R filter and H-alpha filter.

  • PDF

Accuracy of new implant impression technique using dual arch tray and bite impression coping

  • Lee, Shin-Eon;Yang, Sung-Eun;Lee, Cheol-Won;Lee, Won-Sup;Lee, Su Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.265-270
    • /
    • 2018
  • PURPOSE. The purpose of this in vitro study was to evaluate the accuracy of a new implant impression technique using bite impression coping and a dual arch tray. MATERIALS AND METHODS. Two implant fixtures were placed on maxillary left second premolar and first molar area in dentoform model. The model with two fixtures was used as the reference. The impression was divided into 2 groups, n=10 each. In group 1, heavy/light body silicone impression was made with pick up impression copings and open tray. In group 2, putty/light body silicone impression was made with bite impression copings and dual arch tray. The reference model and the master casts with implant scan bodies were scanned by a laboratory scanner. Surface tessellation language (STL) datasets from test groups was superimposed with STL dataset of reference model using inspection software. The three-dimensional deviation between the reference model and impression models was calculated and illustrated as a color-map. Data was analyzed by independent samples T-test of variance at ${\alpha}=.05$. RESULTS. The mean 3D implant deviations of pick up impression group (group 1) and dual arch impression group (group 2) were 0.029 mm and 0.034 mm, respectively. The difference in 3D deviations between groups 1 and 2 was not statistically significant (P=.075). CONCLUSION. Within limitations of this study, the accuracy of implant impression using a bite impression coping and dual arch tray is comparable to that of conventional pick-up impression.

A Study on vibration suppression of dual inertia system using controlling Parameter $\alpha$ of PID controller with 2-degree of freedom (2자유도 PID 제어기의 파라미터 $\alpha$ 추종을 이용한 2관성 시스템의 진동억제)

  • 박재현;추연규;김현덕;박연식
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.506-510
    • /
    • 2004
  • A torque transmission system composed of several gears and couplings is flexible. In order to get an exact response of motor, the torsional vibration due to an unexpected change of motor speed must be suppressed. Therefore, it is very important that motor control suppress vibration. Various methods to control it including dual inertia system are proposed. Specially, the method of vibration suppression is that vibration can be suppressed to fee㏈ack the estimated torsion torque via the disturbance observer filter being of normal filter. The suitable Proportional controller and coefficient parameter can be designed using CDM and the torsional vibration also be suppressed, but it has a low degree of adaptability to disturbance. The PID controller can be designed easily, but makes the excessive overshoot and oscillation for system response in the early period. To resolve these problems, simple and practical PID controller with two degree of freedom is proposed recently that it ran improve performance of obeying the reference unconcerned in any disturbance by changing the proportional gain by two degree of freedom parameter. But it has also the defect that parameter a must be changed to obtain the ideal Proportional parameter. On this paper, we design the controller which automatically adjusts parameter u using fuzzy Algorithm to overcome such defects. Also, we compare the proposed method with established one and evaluate them to confirm performance of the designed controller.

  • PDF

A NEW LOWER BOUND FOR THE VOLUME PRODUCT OF A CONVEX BODY WITH CONSTANT WIDTH AND POLAR DUAL OF ITS p-CENTROID BODY

  • Chai, Y.D.;Lee, Young-Soo
    • Honam Mathematical Journal
    • /
    • v.34 no.3
    • /
    • pp.403-408
    • /
    • 2012
  • In this paper, we prove that if K is a convex body in $E^n$ and $E_i$ and $E_o$ are inscribed ellipsoid and circumscribed ellipsoid of K respectively with ${\alpha}E_i=E_o$, then $\[({\alpha})^{\frac{n}{p}+1}\]^n{\omega}^2_n{\geq}V(K)V({\Gamma}^{\ast}_pK){\geq}\[(\frac{1}{\alpha})^{\frac{n}{p}+1}\]^n{\omega}^2_n$. Lutwak and Zhang[6] proved that if K is a convex body, ${\omega}^2_n=V(K)V({\Gamma}_pK)$ if and only if K is an ellipsoid. Our inequality provides very elementary proof for their result and this in turn gives a lower bound of the volume product for the sets of constant width.