• Title/Summary/Keyword: all inspection

Search Result 1,048, Processing Time 0.024 seconds

Development of Steam-Generator UT System and Experimental Verification (증기발생기 전열관 확관부의 초음파 검사장치 및 적용기술개발)

  • Park, Jae-Seok;Hong, Soon-Sin;Park, Chi-Seung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.5
    • /
    • pp.442-448
    • /
    • 2007
  • The ultrasonic inspection system for the expansion/transition area of steam generator tube was successfully developed. Variety of artificial flaw and real track specimen was tested using the UT system to verify the performance of the system. All artificial flaws of which through-wall depth larger than 10% was clearly detected by UT system. Measurement results of through-wall depth of flaws larger than 20% had good linearity and reproducibility with 3.27 of standard deviation. Results of real crack specimen test suggested that the detection limit of real crack strongly depends on the track morphology. A potential for measurement of PRL(percentage of remaining ligament) was recognized by the real crack specimen test.

Development of Real-Time TCP/COF Inspection System using Differential Image (차영상을 이용한 실시간 TCP/COF 검사 시스템 개발)

  • Lee, Sang-Won;Choi, Hwan-Yong;Lee, Dae-Jong;Chun, Myung-Geun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.1
    • /
    • pp.87-93
    • /
    • 2012
  • In this paper, we proposed a faulty pattern detection algorithm of TCP(Tape Carrier Package)/COF(Chip On Film), and implemented a real-time system for inspecting TCP/COF. Since TCP/COF has very high resolution having several micro meters, the human operator should visually inspect all the parts through microscope. In this work, we implement an inspection system to detect the faulty pattern, so the operator can visually inspect only the designated parts by the inspection system through the monitor. The proposed defects detection algorithm for TCP/COF packages is implemented by the pattern matching method based on subtracting the reference image from test image. To evaluate performance of the proposal system. we made various experiments according to type of CCD camera and light source as well as illumination projection method. From experimental results, it is confirmed that the proposed system makes it possible to detect effectively the defective TCP/COF film.

Automatic TFT-LCD Mura Defect Detection using Gabor Wavelet Transform and DCT (가버 웨이블렛 변환 및 DCT를 이용한 자동 TFT-LCD 패널 얼룩 검출)

  • Cho, Sang-Hyun;Kang, Hang-Bong
    • Journal of Broadcast Engineering
    • /
    • v.18 no.4
    • /
    • pp.525-534
    • /
    • 2013
  • Recently, mura defect inspection techniques are receiving attention in LCD production procedure since demands of TFT-LCD are growing. In this paper, we propose an automatic mura defect inspection method using gabor wavelet transform and DCT. First, we generate a reference panel image using DCT based method. For original panel image and generated reference panel image, we apply a gabor wavelet transform to eliminate texture information in images. Then, we extract mura defect regions from the difference image between gabor wavelet transform image of original panel and generated reference panel image. Finally, all mura defect regions are quantified to detect accurate mura defects. Experimental results show that our method is more accurate and efficient than previous methods.

Research on Sanitation Control for an HACCP Application for a Flatfish (Paralichthys olivaceus) Aquaculture Farm (넙치 양식장 HACCP 적용을 위한 위생관리에 대한 연구)

  • Jee, Bo-Young;Min, Jin-Gi;Kim, Tae-Jin;Choi, Jae-Suk;Park, Sun-Mee
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.25 no.5
    • /
    • pp.1179-1191
    • /
    • 2013
  • Many sanitation control problems due to aging facilities and equipment were identified when applying an HACCP system to a flatfish (Paralichthys olivaceus) aquaculture farm. Specifically, the major problems included a lack of awareness about worker hygiene, lack of management of the use of fish medicines, and vulnerability to secondary contamination by cross-contamination owing to a failure to separate breeding tools used for healthy and unhealthy fish. Therefore, the management standards on the farm regarding the surrounding environment, facilities and equipment, breeding tools, feed and medication, and the hygiene of practitioners must be improved. The hygiene management standards were divided into different procedures such as the management of farm hygiene and environmental sanitation, facilities and equipment, fish hygiene, feed, medications, water, and the stocking and shipping of fish. For each procedure, we established the management standards, inspection period, inspection procedures, and how to deal with errors that occur, to enable hygiene management by a small number of managers. Additionally, an inspection system and record form to implement an HACCP system were developed to maintain systematic management. The management and inspection of all aspects of the farm were designed to be easily managed by the supervisor.

Development of an Ultrasonic Inspection Technique for LP Turbine Rotor Disc (초음파를 이용한 저압 터빈 로타 디스크 검사 기술 개발)

  • Chang, H.K.;Cho, K.S.;Won, S.H.;Chung, M.H.;Cho, Y.S.;Hur, K.B.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.17 no.3
    • /
    • pp.174-183
    • /
    • 1997
  • Turbine rotor disc consists of disc, bore, keyway, hub, and rim in which the typical defects are located. And these part of disc has very complicated geometry, therefore proper transducer selection, wedge design, fabrication, classification and evaluation of the signal identification are required. In this research, test block with the artificial flaws at keyway and boresurface parts have been used in order to establish the ultrasonic inspection technique for flaw detectability on disc. The analysis of the signals from the test blocks was performed. The wedges were designed according to the curvature from the discs. All the ultrasonic signals were collected and identified for evaluation. The ultrasonic inspection technique for the flaw-detection was established from this research. And it is proved that the result of this research can be applicable in the field inspection.

  • PDF

A Film-Defect Inspection System Using Image Segmentation and Template Matching Techniques (영상 세그멘테이션 및 템플리트 매칭 기술을 응용한 필름 결함 검출 시스템)

  • Yoon, Young-Geun;Lee, Seok-Lyong;Park, Ho-Hyun;Chung, Chin-Wan;Kim, Sang-Hee
    • Journal of KIISE:Databases
    • /
    • v.34 no.2
    • /
    • pp.99-108
    • /
    • 2007
  • In this paper, we design and implement the Film Defect Inspection System (FDIS) that detects film defects and determines their types which can be used for producing polarized films of TFT-LCD. The proposed system is designed to detect film defects from polarized film images using image segmentation techniques and to determine defect types through the image analysis of detected defects. To determine defect types, we extract features such as shape and texture of defects, and compare those features with corresponding features of referential images stored in a template database. Experimental results using FDIS show that the proposed system detects all defects of test images effectively (Precision 1.0, Recall 1.0) and efficiently (within 0.64 second in average), and achieves the considerably high correctness in determining defect types (Precision 0.96 and Recall 0.95 in average). In addition, our system shows the high robustness for rotated transformation of images, achieving Precision 0.95 and Recall 0.89 in average.

Realization of Package Software Inspection Service for Software Asset Management (소프트웨어 자산관리를 위한 패키지소프트웨어 점검서비스 구현)

  • Cha, Tea-Won;Ahn, Jae-Kyoung
    • The KIPS Transactions:PartD
    • /
    • v.16D no.1
    • /
    • pp.123-132
    • /
    • 2009
  • Even support-and-management efforts by government are enforced with the growing international restrictions for complying with global standard, not a few private enterprises are still suffering software management problems from lack of understanding the software asset management and carelessness of the software management. This is due to the ambiguous scope of software asset management as well as characteristics of software property such as invisibility, easiness of copy and installation. In other words, it is not easy for software managers to comply all the information throughout the software life cycle; from purchasing, procurement. distribution, preservation to disposition. Therefore, Inspector which has been developed for resolving these problems are proposed in this study. The inspection service consists of search algorithms adapted for software characteristics, standardization of software right management information, and practical use of registry information. Inspection time for a PC by using inspector make the inspection time much shorter. It is also shown that effective software management enables the enterprise to curtail software acquisition cost and to help rationalizing its business management.

Systematic and Comprehensive Comparisons of the MOIS Security Vulnerability Inspection Criteria and Open-Source Security Bug Detectors for Java Web Applications (행정안전부 소프트웨어 보안 취약점 진단기준과 Java 웹 어플리케이션 대상 오픈소스 보안 결함 검출기 검출대상의 총체적 비교)

  • Lee, Jaehun;Choe, Hansol;Hong, Shin
    • Journal of Software Engineering Society
    • /
    • v.28 no.1
    • /
    • pp.13-22
    • /
    • 2019
  • To enhance effective and efficient applications of automated security vulnerability checkers in highly competitive and fast-evolving IT industry, this paper studies a comprehensive set of security bug checkers in open-source static analysis frameworks and how they can be utilized for source code inspections according to the security vulnerability inspection guidelines by MOIS. This paper clarifies the relationship be tween all 42 inspection criteria in the MOIS guideline and total 323 security bug checkers in 4 popular open-source static analysis frameworks for Java web applications. Based on the result, this paper also discuss the current challenges and issues in the MOIS guideline, the comparison among the four security bug checker frameworks, and also the ideas to improve the security inspection methodologies using the MOIS guideline and open-source static security bug checkers.

Comparison of X-ray computed tomography and magnetic resonance imaging to detect pest-infested fruits: A pilot study

  • Kim, Taeyun;Lee, Jaegi;Sun, Gwang-Min;Park, Byung-Gun;Park, Hae-Jun;Choi, Deuk-Soo;Ye, Sung-Joon
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.514-522
    • /
    • 2022
  • Non-destructive testing (NDT) technology is a widely used inspection method for agricultural products. Compared with the conventional inspection method, there is no extensive sample preparation for NDT technology, and the sample is not damaged. In particular, NDT technology is used to inspect the internal structure of agricultural products infested by pests. The introduction and spread of pests during the import and export process can cause significant damage to the agricultural environment. Until now, pest detection in agricultural products and quarantine processes have been challenging because they used external inspection methods. However, NDT technology is advantageous in these inspection situations. In this pilot study, we investigated the feasibility of X-ray computed tomography (X-ray CT) and magnetic resonance imaging (MRI) to identify pest infestation in agricultural products. Three kinds of artificially pest-infested fruits (mango, tangerine, and chestnut) were non-destructively inspected using X-ray CT and MRI. X-ray CT was able to identify all pest infestations in fruits, while MRI could not detect the pest-infested chestnut. In addition, X-ray CT was superior to the quarantine process than MRI based on the contrast-to-noise ratio (CNR), image acquisition time, and cost. Therefore, X-ray CT is more appropriate for the pest quarantine process of fruits than MRI.

Inspection of A Deteriorated Bridge Pier Cap Using Common Nondestructive and Destructive Test (파괴 및 비파괴 검사를 이용한 노후 교량의 교각 두부 조사)

  • Kim, Tae Wan;Hong, Sung Nam;Han, Kyoung Bong;Park, Sun Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.2
    • /
    • pp.91-102
    • /
    • 2008
  • Nondestructive testing techniques have been historically and commonly used to evaluate the quality of existing concrete structures. The techniques utilized included visual inspection, hammer sounding, Schmidt hammer rebounding, and ultrasonic pulse velocity testing including tomographic imaging. Results of the nondestructive tests were used to determine areas to be tested with local destructive tests. These tests included concrete compressive strengths, chloride testing, and petrographic testing. The overall results indicate that inside core of each of the pier caps are healthy. On all of the pier caps, extensive exterior concrete layer rehabilitation needs to be completed. This paper shows the application and interpretation of common nondestructive testing techniques and the consequent repair, rehabilitation, maintenance decisions and safety assesment.