• Title/Summary/Keyword: air current speed

Search Result 255, Processing Time 0.025 seconds

Design and Analysis of the Eddy Current Brake with the Winding Change

  • Cho, Sooyoung;Liu, Huai-Cong;Lee, Ju;Lee, Chang-Moo;Go, Sung-Chul;Ham, Sang-Hwan;Woo, Jong-Hyuk;Lee, Hyung-Woo
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.23-28
    • /
    • 2017
  • This paper is a study of the eddy current brake designed to replace the air brake of railway application. The eddy current brake has the advantage of being able to take a high current density compared to the other application because this brake is used for applying brakes to the rolling stock for a shorter amount of time. Also, this braking system has the merit of being able to take a high current density at low speed rather than at high speed, because the heat generated by the low speed operation is less than that of the high speed operation. This paper also presents a method of improving the output torque of the eddy current brake at low speed operation through a change of the winding as well as the basic design.

A Geothermal Model of Pit Area Using Computational Fluid Dynamics (CFD를 이용한 피트의 지중열 모델 구축에 관한 연구)

  • Min, Joon Ki;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.5
    • /
    • pp.11-16
    • /
    • 2008
  • This research has established CFD model on pit's cool-tube system through heat and air movement simulations, of which data was based on experimental and verification. This research work verified the effectiveness of the cool-tube system by analysing temperature, humidity and air current of the actually installed case. Also, we analysed heat transfer through air current simulation and the results are as followings. Firstly, we experiment on temperature, humidity and speed of air currents of the cool tube system with pit space during the month of May (spring). The average exterior temperature was $16.1^{\circ}C$, and $18.2^{\circ}C$ for the pit, $24.7^{\circ}C$ for the compressor room. Secondly, based on measured data of real case, we have analysed heat transfer through air current simulation and verified our proposed model. The actual measurement of average temperature of exhaust air of the pit's area is $19.7^{\circ}C$ with tolerance of $-0.33^{\circ}C{\sim}-0.6^{\circ}C$ compared to above simulations. Thirdly, having verified air current simulation model with formation of 260,000 and 1,000,000 cells, we could get reasonable near values with 260,000 cells. Lastly, the next step of research would be focused on proposing the best possible pit's cool-tube system after analysis of heat transfer of the air current simulation based on verified CFD model.

Measurements of Mixture Strength Using Spark Plug (스파크 플러그를 이용한 혼합기 농도 측정)

  • 조상현;임명택
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.4
    • /
    • pp.18-25
    • /
    • 2000
  • Ion current in an S.I engine cylinder is measured with the spark plug as a probe. The peak values are confirmed to show a fair correlation with local air-fuel ration and engine speed which implies that the ion current measured at the spark plug may provide a signal for the local mixture strength which is the key parameter in precise fuel control for future engines especially of gasoline direct-injected lean burn engines.

  • PDF

The question at issue of connector wire in High Speed Railway Catenary System of France (프랑스 고속철도 전차선로 시스템에서 균압선의 문제점)

  • 안영훈
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.636-651
    • /
    • 2000
  • In these days, SNCF replace the connector wire (M-T type) with a dropper has a equivalent role and function of the one in general lines of TGV, and change the connector wire (T-T-M-M-T-T, T-T-M-M-T type, etc) into a New one has more flexible cable in parallel lines (air section air joint, etc) of TGV. The Connector wire has many problems according to a flow of excessive circulation current (or traction current) and a sudden rise of temperature on catenary when electric locomotive is running in high speed. To solve the question at issue of the connector wire in high speed railway catenary system of Fiance, SNCF return their operating experience in TGV lines to design and execution of catenary system Therefore, we have to deal with the question in design and execution of catenary system for kyoungbu HSR line because we will spend a lot of time and more money for maintenance than for construction of that.

  • PDF

Analysis of the Magnetic Effect on the Tube Infrastructure for a Super Speed Tube Train

  • Lee, Hyung-Woo;Cho, Su-Yeon;Cho, Woo-Yeon;Lee, Ju;Kwon, Hyeok-Bin
    • International Journal of Railway
    • /
    • v.2 no.4
    • /
    • pp.170-174
    • /
    • 2009
  • Super speed tube train is introduced to increase the speed of ground transportation. The super speed tube train levitates magnetically and runs in a partial vacuum tube, which can reduce the air resistance significantly. However, the strong magnetic force enough to propel the massive train can affect to the tube infrastructure. In this paper, authors have analyzed the leakage flux patterns and induced eddy current on the tube by using 3-dimensional Finite Element Method. These effects are investigated, especially by varying the materials and diameters of the tube. From the simulation results, the aluminum tube with the diameter of 3[m] is needed to be concerned because the induced eddy current produces joule heat, raises the inside temperature of the tube, and might be able to lead to electro-chemical corrosion on the tube, consequently reduce the durability.

  • PDF

Research on the air data acquisition method using static pressure hole (정압력 홀을 적용한 초고속 유동 데이터 획득 방안에 관한 연구)

  • Choi, Jong-Ho;Yoon, Hyun-Gull
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.406-410
    • /
    • 2010
  • Current paper represents the air data acquisition and processing algorithm which can acquire the air data such as velocity and angle of attack by measuring the static pressure on the specific locations of a high speed aerial vehicle. Unlike the previous air data acquisition system, current system applied several pre-determined data obtained from computational fluid dynamic approach having enough sensor redundancy and fault detection ability. The verification of current algorithm was done by commercial software Matlab and Simulink.

  • PDF

An Experimental Study on Sealing Improvements of Non-Contact Type Seal for Oil Mist Lubrication

  • Na, Byung-Chul;Chun, Keyoung-Jin;Han, Dong-Chul
    • KSTLE International Journal
    • /
    • v.3 no.2
    • /
    • pp.79-83
    • /
    • 2002
  • Sealing an oil-air mixture plays important roles to have an enhanced lubrication for high speed spindle. High speed spindle requires non-contact type of sealing mechanism. Current work emphases on the investigation of the air jet effect on the protective collar type labyrinth seal. To improve the sealing capability of conventional labyrinth seal, air jet was injected against through the leakage flow, It has a combined geometry of a protective collar type and an air jet type. Both of a numerical analysis by CFD (Computational Fluid Dynamics) and experimental measurements are carried out to verify sealing improvement The sealing effects of the leakage clearance and the air jet magnitude are studied in various parameters. The results of pressure drop in the experiment match reasonably to those of the simulation by introducing a flow coefficient Effect of sealing improvement is explained as decreasing of leakage clearance by air jetting. Thus, sealing effect is improved by amount of air jetting even though clearance becomes larger.

PFC Bridge Converter for Voltage-controlled Adjustable-speed PMBLDCM Drive

  • Singh, Sanjeev;Singh, Bhim
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.215-225
    • /
    • 2011
  • In this paper, a buck DC-DC bridge converter is used as a power factor correction (PFC) converter for feeding a voltage source inverter (VSI) based permanent magnet brushless DC motor (PMBLDCM) drive. The front end of the PFC converter is a diode bridge rectifier (DBR) fed from single phase AC mains. The PMBLDCM is used to drive the compressor of an air conditioner through a three-phase voltage source inverter (VSI) fed from a variable voltage DC link. The speed of the air conditioner is controlled to conserve energy using a new concept of voltage control at a DC link proportional to the desired speed of the PMBLDC motor. Therefore, VSI operates only as an electronic commutator of the PMBLDCM. The current of the PMBLDCM is controlled by setting the reference voltage at the DC link as a ramp. The proposed PMBLDCM drive with voltage control-based PFC converter was designed and modeled. The performance is simulated in Matlab-Simulink environment for an air conditioner compressor load driven through a 3.75 kW, 1500 rpm PMBLDC motor. To validate the effectiveness of the proposed speed control scheme, the evaluation results demonstrate improved efficiency of the complete drive with the PFC feature in a wide range of speed and input AC voltage.

Magnetic Interference on the Infrastructure for a Super-speed Tube Train

  • Lee, Hyung-Woo;Jang, Seung-Yup;Kang, Bu-Byoung;Cho, Su-Yeon;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.364-368
    • /
    • 2011
  • The super-speed tube train was introduced to increase the speed of ground transportation. It levitates magnetically and runs in a partial vacuum tube, which significantly reduces air resistance. However, strong magnetic force sufficient to propel the massive train can affect the infrastructure. The induced eddy current produces joule heat, and raises the inside temperature of the girder, which might lead to electrochemical corrosion on the girder, thereby weakening its durability. In this paper, the authors analyzed the magnetic flux and induced eddy current in the reinforced concrete girder by using three-dimensional FEM, particularly by varying the number of reinforcing steels of the upper flange of the girder to the condition of almost the same flexural strength and reinforcing steel amount.

Hydrodynamic modeling of semi-planing hulls with air cavities

  • Matveev, Konstantin I.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.7 no.3
    • /
    • pp.500-508
    • /
    • 2015
  • High-speed heavy loaded monohull ships can benefit from application of drag-reducing air cavities under stepped hull bottoms. The subject of this paper is the steady hydrodynamic modeling of semi-planing air-cavity hulls. The current method is based on a linearized potential-flow theory for surface flows. The mathematical model description and parametric calculation results for a selected configuration with pressurized and open air cavities are presented.