• 제목/요약/키워드: aged material

검색결과 547건 처리시간 0.028초

DC Potential Drop Method for Evaluating Material Degradation

  • Seok, Chang-Sung;Bae, Bong-Kook;Koo, Jae-Mean
    • Journal of Mechanical Science and Technology
    • /
    • 제18권8호
    • /
    • pp.1368-1374
    • /
    • 2004
  • The remaining life estimation for the aged components in power plants as well as chemical plants are very important because mechanical properties of the components are degraded with in-service exposure time in high temperatures. Since it is difficult to take specimens from the operating components to evaluate mechanical properties of components, nondestructive techniques are needed to evaluate the degradation. In this study, test materials with several different degradation levels were prepared by isothermal aging heat treatment at $630^{\circ}C$. The DC potential drop method and destructive methods such as tensile and fracture toughness were used in order to evaluate the degradation of 1Cr-1Mo-0.25V steels. In this result, we can see that tensile strength and fracture toughness can be calculated from resistivity and it is possible to evaluate material degradation using DC potential drop method, non-destructive method.

사용중인 구조물의 보강효과에 대한 해석적 연구 (Numerical Analysis on External Strengthening Effects in Aged Structures)

  • 신승교;임윤묵;김문겸;박동철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.455-460
    • /
    • 2002
  • In this study, a numerical analysis that can effectively predict the effect of strengthening of cracked flexural members is developed using axial deformation link elements. Concrete and interface between concrete and repair material are considered as quasi-brittle material. Reinforcing bars and reinforcing steel plates are assumed to perform as elasto-plastic materials. Unloading behavior of axial deformation link element is implemented. In the developed numerical model, a flexural member is intentionally cracked by pre-loading, then, the cracked member is repaired using extra elements, and reloaded. The results from analysis of repaired flexural members agrees well with available experiment results. Also, it was shown that the effect of strengthening and the change of failure mode with respect to the time for strengthening and thickness of repair materials. Based on the results, it was determined that the developed numerical model has a good agreement for determining failure modes and effect of strengthening in cracked flexural members. By utilizing the developed numerical analysis, the time and dimension of external strengthening in an existing cracked flexural member with predition of failure mechanism can be determined.

  • PDF

발전기 고정자 권선에서 사용되는 마이카/에폭시의 열적 분석 (Thermal Analysis of Mica/Epoxy Composites used In Generator Stator Windings)

  • 김희동;김태완;김정훈
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 춘계학술대회 논문집
    • /
    • pp.330-333
    • /
    • 1997
  • The thermal impact of mica/epoxy paper(130${\mu}{\textrm}{m}$) is investigated using XRD, DSC and TGL X-ray diffraction(XRD) analysis was performed to know the position and structure of mica crystal in insulation materials. A differential scanning calorimeter(DSC) was used to measure glass transition temperature and excess enthalphy of the composite materials that had been subjected to thermal aging. The glass transition temperature(T$_{g}$) measured by DSC is observed at 95.43$^{\circ}C$ and 113.43$^{\circ}C$, respectively. The T$_{g}$ also increases with increased aging time. Measurements performed by TGA(thermogravimetric analysis) have showed that weight loss profile of sound specimens are lower than those aged.ged.

  • PDF

솔더범프와 TiW/Cu/electroplating Cu UBM 층과의 금속간 화합물 형성과 범프 전단력에 관한 연구 (A Study of the IMC Growth and Shear Strength of Solder Bump and TiW/Cu/electroplating Cu UBM)

  • 장의구;김남훈;김남규;엄준철
    • 한국전기전자재료학회논문지
    • /
    • 제17권3호
    • /
    • pp.267-271
    • /
    • 2004
  • The joint strength and fracture surface of Sn-Pb solder bump in photo diode packages after isothermal aging testing were studied experimentally. Cu/Sn-Pb solders were adopted, and aged for up to 900 hours at 12$0^{\circ}C$ and 17$0^{\circ}C$ to analyze the effect of intermetallic compound(IMC). In 900-hour aging experiments, the maximum shea strength of Sn-Pb solder decreased by 20% and 9%. The diffraction patterns of Cu$_{6}$Sn$_{5}$, scallop-shape IMC, and planar-shape Cu$_3$Sn were observed by Transmission Electron Microscopy (TEM).EM).

산성비 중 질산 성분에 의한 옥외용 실리콘고무 애자의 열화특성 연구 (An Experimental Investigation of a Effect of the Nitric Solution on the Aging Characteristics of the Outdoor Silicone Rubber Insulator)

  • 이정현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 기술교육위원회 창립총회 및 학술대회 의료기기전시회
    • /
    • pp.28-33
    • /
    • 2001
  • In this paper, aging characteristics of outdoor silicone rubber insulator resulting from the acid rain have been investigated with regards to nitrate ion ($NO^{-1}_{3}$ ). For this purpose, silicone rubber was aged by immersing into the nitric solutions with different level pH during 1500 hours and various tests (tracking, tan $\delta$, breakdown voltage, SEM, EDS, contact angle) were performed. It was observed that the degradation was increased to pH 2.5 slightly and at pH 1.5 highly. And thus, it could be expected that there is certain critical point between pH 1.5 and 2.5, which leads to throught degradation.

  • PDF

목모 세라믹 보드용 알루미노-실리케이트계 무기 바인더의 물리적 특성 향상에 관한 실험적 연구 (An experimental study for improvement in physical properties on the alumino-silicate binder for wood wool ceramic board)

  • 박동철;양완희;최해영;이세현;송태협;심종우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.625-628
    • /
    • 2006
  • It is known that cement production not only consumes large amount of energy but also contributes substantially to the green house gas emission. Therefore, there is a demand to develope a new technology to produce energy efficient and environmental conscious cements. The most recent, wood wool ceramic board is being applied in various building material field, for example thermal insulating and acoustic absorption material. This paper focused on improvement of alumino-silicate binder's physical properties for wood wool ceramic board. As the result of this experiment, what we could obtain best fitted alumino-silicate binder's properties such as initial setting time, flow and compressive strength of 3 days aged, was 58min, 110% and 66.0Mpa. This result can be applicable to commercial wood wool ceramic board.

  • PDF

알츠하이머 조기 진단을 위한 변형된 대식세포의 기초적 연구 (Primary Cellular Study of Phagocytosis for Alzheimer Disease Diagnosis)

  • 조정민;채철주;강재민;김관수;송기봉
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.280-280
    • /
    • 2010
  • Alzheimer disease is a progressive neurodegenerative disease of the aged, characterized by memory loss and dementia. For diagnosis of Alzheimer disease we have simply modified macrophage with amyloid beta bonded with different molecules. Modified Macrophage was observed with microscope for co-localization of amyloid beta molecule. For this experiment we used fluoroscene labeling substances. The macrophage was modified also with cell staining method. For cell staining method was used avidin-biotin reaction principles. All experiments were carried out on poly-L-lysine coated and sterilized glass substrates. In the presentation we will show the further investigations and applications with modified macrophage.

  • PDF

고압케이블의 절연열화 특성 (Characteristics of Insulation Aging in High Voltage Cables)

  • 김경열
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.88-88
    • /
    • 2010
  • High Voltage cross-linked polyethylene (XLPE) cables are widely used in a thermal power plant. These cables had been in service for 26 years. The insulation condition of six 6 kV XLPE cables was estimated by insulation diagnostic analyzer (IDA) with voltage amplifier. IDA was measured dissipation factor and capacitance of the whole cable as a function of frequency and voltage. This system measures in the frequency range from 0.1 to 10 Hz at each voltage level. Six XLPE cables are judged good condition, but three cables are analyzed at an aged condition.

  • PDF

에폭시 제진의 장기적인 특성연구 (A Study on the Long term Properties of Epoxy Resin)

  • 한만엽;송병표;이원창;연규석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.89-94
    • /
    • 1997
  • As the reinforced concrete structures are aged, repair and rehabilitation materials and techniques have ben developed. However, most of the repair materials and methods are imported from abroad and theoretical study and repairing techniques are also not well established yet. A specification for quality of repair materials should be established, in order to secure the stability and to improve the serviceability of the repaired structures. In this study, long term properties of repair materials such as thermal expansion coefficient, hardening shrinkage, creep, and chemical resistance have been tested. The material properties shows to be affected many actors such as curing period, temperatures, relative humidity, and etc. The repair material should be selected by considering the cause and shape of the defects, mix properties, workability, quality control of construction, and etc.

  • PDF

가속 열 열화에 따른 환경친화형 변압기 절연물의 전기적-기계적 특성 분석 (Analyses on Electrical-Mechanical Characteristics of Environment-friendly Transformer Insulating Material by Accelerated Thermal Aging)

  • 심명섭;안정식;최순호;정중일;이태호;허창수
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1832-1838
    • /
    • 2010
  • Aging of transformer insulating material in natural ester insulating oil is compared to that in conventional transformer oil. Aging of insulating paper and insulating oil have been studied by performing accelerated thermal aging test. Sealed aging test vessels containing cooper, laminated core, Kraft paper and insulating oil(natural oil or mineral oil) were aged at $140^{\circ}C$ for 500, 1000, 1500 and 2000 hours. Insulating oils after aging are investigated with total acid number, breakdown voltage and viscosity. Also, degradation of insulating paper after aging is determined using breakdown voltage and mechanical strength. Accelerated aging studies demonstrate a slower aging rate for natural ester insulating oil compared to the rate for conventional mineral oil.