• 제목/요약/키워드: adaptive protection

검색결과 157건 처리시간 0.031초

풍력발전기의 출력변화에 따른 적응형 과전류계전기 (An Adaptive Overcurrent Relay for a Wind Power Generator Having Variable Outputs)

  • 최동민;권영진;이동규;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.99-101
    • /
    • 2005
  • This paper presents an adaptive overcurrent relay applied to interconnecting wind generators in distribution networks. When a fault occurs in the case of the decreasing the wind power generator output, the conventional overcurrent relay can't detect the fault. The suggested adaptive overcurrent relay can detect. An adaptive overcurrent relay improves reliability and security of the power system protection with distributed generator APSCAD/EMTDC simulation results have shown effectiveness of the proposed method.

  • PDF

New Adaptive Linear Combination Structure for Tracking/Estimating Phasor and Frequency of Power System

  • Wattanasakpubal, Choowong;Bunyagul, Teratum
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권1호
    • /
    • pp.28-35
    • /
    • 2010
  • This paper presents new Adaptive Linear Combination Structure (ADALINE) for tracking/estimating voltage-current phasor and frequency of power system. To estimate the phasors and frequency from sampled data, the algorithm assumes that orthogonal coefficients and speed of angular frequency of power system are unknown parameters. With adequate sampled data, the estimation problem can be considered as a linear weighted least squares (LMS) problem. In addition to determining the phasors (orthogonal coefficients), the procedure estimates the power system frequency. The main algorithm is verified through a computer simulation and data from field. The proposed algorithm is tested with transient and dynamic behaviors during power swing, a step change of frequency upon islanding of small generators and disconnection of load. The algorithm shows a very high accuracy, robustness, fast response time and adaptive performance over a wide range of frequency, from 10 to 2000 Hz.

자율적응형 과전류계전기 에이전트의 통신을 위한 ACL모듈 개발 (Development of ACL Modul For Agent Communication in Auto-Adaptive OCR Agent)

  • 오태욱;이승재;최면송;김기화;임성일;민병운;이한웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.193-195
    • /
    • 2002
  • In this paper, a communication module is proposed to be applied to communication between over current relay (OCR) agents in multi agent protection system. A multi agent system can achieve a global goal beyond the ability of each individual agent by working together, in which it is the prerequisite for each agent to be able to exchange or share information or processing status with other agent. The proposed communication module is purposed to enable not only each agent to bring about its own goal, but also the whole protective system to provide much improved coordinated protection. It is applied to a self adaptive protection system for a distribution network using multi agent concept to show its effectiveness.

  • PDF

치매환자용 기능성 의류개발 (A Study on the Development of Adaptive Clothing for the Dementia Patients)

  • 이승민;이경옥
    • 한국의류산업학회지
    • /
    • 제16권6호
    • /
    • pp.849-859
    • /
    • 2014
  • This study developed adaptive clothing to increase psychological comfort and protection for dementia patients. Our research method and data collection were as follows. The author selected and interviewed 10 caregivers and nurses to understand dementia patient behavior. The author collected eight pieces of clothing designed for dementia patients that are sold in Korean and overseas markets. We then analyzed garment details, open systems, close systems, and expected functions. Adaptive clothing for dementia patients were developed based upon our research. The results are as follows. First, dementia patients' behavior differed by dementia patient symptoms. Second, all items sold in Korean and overseas markets were jump suits designed to prevent behavior characteristic of dementia patients. Third, the author designed and manufactured five pieces of adaptive clothing for dementia patients that included two for mild dementia patients and three for moderate dementia patients. A panel of 50 caregivers gave high marks to developed clothing in regards to functionality, hygiene, patient human rights and aesthetics. The adaptive clothing of dementia patients from this research will increase the psychological and emotional satisfaction of dementia patients.

신경회로망을 이용한 UPFC가 연계된 송전선로의 거리계전기에 관한 연구 (A Study on Distance Relay of Transmission UPFC Using Artificial Neural Network)

  • 이준경;박정호;이승혁;김진오
    • 조명전기설비학회논문지
    • /
    • 제18권6호
    • /
    • pp.37-44
    • /
    • 2004
  • 전력계통분야의 복합 대형화에 유연한 대처와 전력조류의 최적화 도모를 위해 사용되는 FACTS(Flexible AC Transmission System)기기 중 가장 유용한 UPFC(Unified Power Flow Controller)는 선로의 전압을 임의의 크기와 위상을 갖도록 제어하여 선로로 전송되는 유ㆍ무효전력을 총체적으로 보상하는 기능을 갖는다. 이런 UPEC가 계통에 연계되어 운영된다면 송전선로 매개변수가 변하기 때문에 계통의 영향을 많이 받는 거리계전기는 불필요한 오동작이 발생하게 된다. 즉 거리계전기에서 바라본 임피던스 영역(Impedance Zone)이 송전선로에 UPFC 연계시 각각의 보상 값에 의해 상당한 변화를 보임으로, 기존의 방식으로 정정된 Relay Setting Zone과 Adaptive Setting Zone은 현저한 오차가 발생하게 된다. 그러므로 계통에 연계된 UPFC의 운전 조건을 고려한 거리계전기 보호구간의 재설정이 필요하게 된다. 따라서 본 논문의 목적은 학습이 가능한 신경회로망(ANN)을 이용하여 거리계전기 동작의 신속성(Speed)을 기본으로 전력계통의 다양한 환경에 대해 거리계전기 응동 특성을 향상시키는데 있다. 학습 방법으로는 정적 및 동적인 비선형 시스템의 인식과 다변수 시스템에 적용 가능한 역전파 알고리즘(Back-propagation Algorithm)을 사용했다.

전력용 변압기 보호를 위한 IED (Intelligent Electronic Device for Power Transformer Protection)

  • 박철원;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.365-367
    • /
    • 2005
  • This paper proposes a hardware of IED for power transformer protection that is well constructed using DSP chip and MPU chip. The performance of the adaptive relaying algorithm, by real-time testing in a prototype of it, has been verified. And test results indicate the proposed relaying of the IED was proven to be faster and more reliable.

  • PDF

An Adaptive Setting Method for the Overcurrent Relay of Distribution Feeders Considering the Interconnected Distributed Generations

  • Jang Sung-Il;Kim Kwang-Ho;Park Yong-Up;Choi Jung-Hwan;Kang Yong-Cheol;Kang Sang-Hee;Lee Seung-Jae;Oshida Hideharu;Park Jong-Keun
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권4호
    • /
    • pp.357-365
    • /
    • 2005
  • This research investigates the influences of distributed generations (DG), which are interconnected to the bus by the dedicated lines, on the overcurrent relays (OCR) of the neighboring distribution feeders and also proposes a novel method to reduce the negative effects on the feeder protection. Due to the grid connected DG, the entire short-circuit capacity of the distribution networks increases, which may raise the current of the distribution feeder during normal operations as well as fault conditions. In particular, during the switching period for loop operation, the current level of the distribution feeder can be larger than the pickup value for the fault of the feeder's OCR, thereby causing the OCR to perform a mal-operation. This paper proposes the adaptive setting algorithm for the OCR of the distribution feeders having the neighboring dedicated feeders for the DG to prevent the mal-operations of the OCR under normal conditions. The proposed method changes the pickup value of the OCR by adapting the power output of the DG monitored at the relaying point in the distribution network. We tested the proposed method with the actual distribution network model of the Hoenggye substation at the Korea Electric Power Co., which is composed of five feeders supplying the power to network loads and two dedicated feeders for the wind turbine generators. The simulation results demonstrate that the proposed adaptive protection method could enhance the conventional OCR of the distribution feeders with the neighboring dedicated lines for the DG.

LDPC 부호화 고차 변조 시스템을 위한 신뢰성 기반의 적응적 비트 매핑 기법 (Adaptive Bit-Reliability Mapping for LDPC-Coded High-Order Modulation Systems)

  • 주형건;홍송남;신동준
    • 한국통신학회논문지
    • /
    • 제32권12C호
    • /
    • pp.1135-1141
    • /
    • 2007
  • 본 논문에서는 LDPC 부호화 고차 변조 시스템의 비트 레벨 체이스 결합 (Chase combining)을 위한 신뢰성 기반의 적응적 비트 매핑 기법을 제안한다. 정보 (혹은 패리티) 비트를 더 신뢰도가 높은 (혹은 신뢰도가 낮은) 비트 위치에 할당하는 기존의 비트 매핑 기법에 비해, 제안한 기법은 부호의 특성과 고차 변조 신호를 구성하는 비트들의 보호 (Protection) 레벨 차이를 동시에 고려하여 부호어 비트를 최적의 비트 위치에 할당한다. 연접 지그재그 (CZZ) 부호에 대하여 제안된 매핑 기법을 심볼 레벨 체이스 결합 기법, 신호 성상도 재배치 비트 매핑 기법과 비교하여, 전체 시스템 복잡도를 동일하게 유지한 경우 $FER=10^{-3}$에서 각각 $0.7{\sim}1.3$ dB와 $0.1{\sim}1.0$ dB 성능 이득을 보임을 모의 실험으로 확인하였다. 그리고 다양한 환경에 대한 적응적 비트 매핑 기준을 유도하고 이를 모의 실험을 통해 검증하였다.

An Adaptive Watermark Detection Algorithm for Vector Geographic Data

  • Wang, Yingying;Yang, Chengsong;Ren, Na;Zhu, Changqing;Rui, Ting;Wang, Dong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권1호
    • /
    • pp.323-343
    • /
    • 2020
  • With the rapid development of computer and communication techniques, copyright protection of vector geographic data has attracted considerable research attention because of the high cost of such data. A novel adaptive watermark detection algorithm is proposed for vector geographic data that can be used to qualitatively analyze the robustness of watermarks against data addition attacks. First, a watermark was embedded into the vertex coordinates based on coordinate mapping and quantization. Second, the adaptive watermark detection model, which is capable of calculating the detection threshold, false positive error (FPE) and false negative error (FNE), was established, and the characteristics of the adaptive watermark detection algorithm were analyzed. Finally, experiments were conducted on several real-world vector maps to show the usability and robustness of the proposed algorithm.

전압파형의 THD를 이용한 영구/일시고장 판별 적응형 재폐로 기법 (An Adaptive Reclosing Algorithm to Discriminate between Permanent Fault and Transient Fault using THD of Voltage Waveform)

  • 이철문;김철환
    • 전기학회논문지
    • /
    • 제59권8호
    • /
    • pp.1347-1352
    • /
    • 2010
  • This paper presents a new adaptive single-phase auto reclosure (SPAR) algorithm to discriminate between a permanent fault and a transient fault and to minimize a protection dead time. The algorithm precisely detects the extinction of the secondary arc, based on THD's profiles on the faulted phase voltage waveform. The EMTP/ATPDraw program was used to simulate the single phase grounding fault for evaluating the proposed algorithm. And the simulation results show that the proposed algorithm is performing well.