• Title/Summary/Keyword: active state control

Search Result 567, Processing Time 0.024 seconds

Energy-saving optimization on active disturbance rejection decoupling multivariable control

  • Da-Min Ding;Hai-Ma Yang;Jin Liu;Da-Wei Zhang;Xiao-Hui Jiang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.850-860
    • /
    • 2023
  • An industrial control process multiple-input multiple-output (MIMO) coupled system is analyzed in this study as an example of a Loss of Coolant Accident (LOCA) simulation system. Ordinary control algorithms can complete the steady state of the control system and even reduce the response time to some extent, but the entire system still consumes a large amount of energy after reaching the steady state. So a multivariable decoupled energy-saving control method is proposed, and a novel energy-saving function (economic function, Eco-Function) is specially designed based on the active disturbance rejection control algorithm. Simulations and LOCA simulation system tests show that the Eco-function algorithm can cope with the uncertainty of the multivariable system's internal parameters and external disturbances, and it can save up to 67% of energy consumption in maintaining the parameter steady state.

Active Control of Structures Using Lattice Probabilistic Neural Network (격자 확률신경망 기법을 이용한 구조물의 능동 제어)

  • Kim, Dong-Hyawn;Chang, Seong-Kyu;Kwon, Soon-Duck;Kim, Doo-Kie
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.7 s.124
    • /
    • pp.662-667
    • /
    • 2007
  • A new neuro-control scheme for active control of structures is proposed. It utilizes lattice pattern of state vector as training data of probabilistic neural network(PNN). Therefore. it is the so-called lattice probabilistic neural network(LPNN). PNN makes control forces by using all the training patterns. Therefore, it takes much time to obtain a control force in application. This inevitably may delay the control action. However. control force of LPNN is calculated by using only the adjacent information of LPNN input. So, the response of LPNN is greatly faster than PNN. The proposed control algorithm is applied for three story building under California and El Centro earthquakes. Also, control results of the LPNN are compared with those of the conventional PNN. The structural responses have been suppressed effectively by the proposed algorithm.

Vibration Control of a Rotating Cantilevered Beam Using Piezoceramic Actuators (압전 세라믹 작동기를 이용한 회전 외팔 보의 진동 제어)

  • 박종석;최승복;정재천
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.255-259
    • /
    • 1996
  • This paper presents active vibration control of a rotating cantilevered beam using piezoceramic actuators. A governing equation of motion is obtained by the Hamilton's principle and expressed in the state space representation. Subsequently, an H$_{\infty}$ control which is robust to system uncertainties is synthesized through the loop shaping design procedure. Computer simulations for the steady-state vibration control are undertaken in order to demonstrate the effectiveness and robustness of the proposed control methodology..y.

  • PDF

Design of Active Disturbance Rejection Control for Inductive Power Transfer Systems

  • Wang, Yanan;Dong, Lei;Liao, Xiaozhong;Ju, Xinglong;Xiao, Furong
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1434-1447
    • /
    • 2018
  • The control design of inductive power transfer (IPT) systems has attracted a lot of attention in the field of wireless power transmission. Due to the high-order resonant networks and multiple loads in IPT systems, a simplified model of an IPT system is preferred for analysis and control design, and a controller with strong robustness is required. Hence, an active disturbance rejection control (ADRC) for IPT systems is proposed in this paper. To realize the employment of ADRC, firstly a small-signal model of an LC series-compensative IPT system is derived based on generalized state-space averaging (GSSA), then the ADRC is implemented in the designed IPT system. The ADRC not only provides superior robustness to unknown internal and external disturbances, but also requires few knowledge of the IPT system. Due to the convenient realization of ADRC, the designed IPT system retains its simple structure without any additional circuits. Finally, a frequency domain analysis and experimental results have validated the effectiveness of the employed ADRC, especially its robustness in the presence of frequency drifts and other common disturbances.

Model Predictive Control for Shunt Active Power Filter in Synchronous Reference Frame

  • Al-Othman, A.K.;AlSharidah, M.E.;Ahmed, Nabil A.;Alajmi, Bader. N.
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.405-415
    • /
    • 2016
  • This paper presents a model predictive control for shunt active power filters in synchronous reference frame using space vector pulse-width modulation (SVPWM). The three phase load currents are transformed into synchronous rotating reference frame in order to reduce the order of the control system. The proposed current controller calculates reference current command for harmonic current components in synchronous frame. The fundamental load current components are transformed into dc components revealing only the harmonics. The predictive current controller will add robustness and fast compensation to generate commands to the SVPWM which minimizes switching frequency while maintaining fast harmonic compensation. By using the model predictive control, the optimal switching state to be applied to the next sampling time is selected. The filter current contains only the harmonic components, which are the reference compensating currents. In this method the supply current will be equal to the fundamental component of load current and a part of the current at fundamental frequency for losses of the inverter. Mathematical analysis and the feasibility of the suggested approach are verified through simulation results under steady state and transient conditions for non-linear load. The effectiveness of the proposed controller is confirmed through experimental validation.

Active Control of Earthquake Responses Using Fuzzy Supervisory Control Technique (퍼지관리제어기법을 이용한 지진응답의 능동제어)

  • 박관순;고현무;옥승용
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.4
    • /
    • pp.75-81
    • /
    • 2001
  • Fuzzy supervisory control method is studied for the active control of earthquake excited structures. The proposed algorithm supervises and tunes previously designed control gains by evaluating the state of a structure through the fuzzy inference mechanism, which uses the information of relative displacements and velocities. Example designs and numerical simulations of earthquake exited three degrees of freedom structures are performed to prove the validity of the proposed control algorithm. Comparative results with conventional LQR method show that the proposed method is effective for the vibration suppression of earthquake excited structures.

  • PDF

A Study on the Stability Characteristics of Actively Controlled Externally Pressurized Air Journal Bearing (능동 제어되는 외부 가압 공기 베어링의 안정 특성에 관한 연구)

  • Lee, Jeong-Bae;Kim, Gyeong-Ung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.3 s.174
    • /
    • pp.543-549
    • /
    • 2000
  • Results of theoretical investigations of the stability characteristics of an actively controlled externally pressurized air journal bearing are presented. Proportional control and derivative control are used for the control algorithm of active air bearing. The stability characteristics of the actively controlled bearing operating at zero steady-state eccentricity is investigated with the step jump method. The speed at onset of instability is raised for both proportional control and derivative control of bearing. Proportional control increased the stability threshold without affecting the whirl ratio. But for derivative control of bearing, stability threshold increase is accompanied by a parallel reduction of the whirl ratio. Results show active control of bearing can be adopted for the stability improvement of air journal bearing.

Experimental Study on the Vibration Control for Building Structures using LQG Compensator (LQG 보상기를 이용한 건물의 진동제어 실험)

  • 민경원
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.04a
    • /
    • pp.202-216
    • /
    • 1999
  • To control the motion of building structures under earthquakes their response should be measured first by various sensors and transformed into the control forces using some control algorithms. Of many control algorithms linear quadratic control is widely used as it is easy to implement and analyze. However the algorithms has the disadvantage that it needs the real-time measurements of all state variables(i.e, building's displacements and velocities) which are difficult to achieve for the building structures under earthquakes. Thus the practical algorithms employing output feedback are developed. In this paper LQG algorithm is used for the control of the building model with an active mass driver. The building's acceleration is used to obtain the control gain and the Kalman filter gain. The LQG control strategy is verified with the experimental study on the one-storybuilding model equipped with the active mass driver. This paper demonstrates experimentally the efficacy of the LQG algorithm based on the active mass driver system in reducing the response of seismically excited buildings.

  • PDF

A Parallel Operation System of the Z-Source Active Power Filter with Fuel Cells System (연료전지 Z-소스 능동전력필터의 병렬운전 시스템)

  • Oum, J.H.;Jung, Y.G.;Lim, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.372-375
    • /
    • 2006
  • This paper proposes a parallel operation system of the Z-source active power filter using one fuel cells(FC) system. The proposed system is composed of two Z-source inverters operating in parallel only one PEM(Polymer Electrolyte Membrane)FC system. Also, as the control algorithm of the active power filter, a single phase P-Q theory and PI control are adopted. The effectiveness of the proposed the system is verified by the PSIM simulation in the steady state and the transient state.

  • PDF

Effects of Oxygen Scavenging Package on the Quality Changes of Processed Meatball Product

  • Shin, Yang-Jai;Shin, Joong-Min;Lee, Youn-Suk
    • Food Science and Biotechnology
    • /
    • v.18 no.1
    • /
    • pp.73-78
    • /
    • 2009
  • Processed meatball products were packaged in a passive package without oxygen scavenger as 1 control and 3 active packages of which have PP-based oxygen scavenger master batch materials (OSMB) of 40, 80, and 100%(w/w) in the middle layer and stored at 23 and $30^{\circ}C$ up to 9 months. Quality changes of packaged products were evaluated by measuring the oxygen concentration of the headspace in containers, thiobarbituric acid (TBA), color, and flavor. The oxygen concentration of the package having 100% OSMB was lower than those of 40 and 80%. The color changes and TBA values of the meat ball in the package containing 100% OSMB were the least among the treatments. Using principal component analysis (PCA), the control showed more flavor change than the packages containing oxygen scavenger. As a result, all active packages could extend the shelf life of the meatball products compared with that of the passive package.