• Title/Summary/Keyword: active pressure

Search Result 954, Processing Time 0.028 seconds

Application of Gas to Particle Conversion Reaction to increase the DeSOx/DeNOx Efficiency under Pulsed Corona Discharge (DeSOx/DeNOx 효율 개선을 위한 펄스 코로나 방전하에서 기체미립자 전환반응의 적용)

  • Choi, Yu-ri;Kim, Dong-Joo;Kim, Kyo-Seon
    • Journal of Industrial Technology
    • /
    • v.18
    • /
    • pp.249-258
    • /
    • 1998
  • In this paper, we investigated the post-combustion removal of nitrogen oxide($NO_x$) and sulfur oxide($SO_x$) which is based on the gas to particle conversion process by the pulsed corona discharge. Under normal pressure, the pulsed corona discharge produces the energetic free electrons which dissociate gas molecules to form the active radicals. These radicals cause the chemical reactions that convert $SO_x$ and $NO_x$ into acid mists and these mists react with $NH_3$ to form solid particles. Those particles can be removed from the gas stream by conventional devices such as electrostatic precipitator or bag filter. The reactor geometry was coaxial with an inner wire discharge electrode and an outer ground electrode wrapped on a glass tube. The simulated flue gas with $SO_x$ and $NO_x$ was used in the experiment. The corona discharge reactor was more efficient in removing $SO_x$ and $NO_x$ by adding $NH_3$ and $H_2O$ in the gas stream. We also measured the removal efficiency of $SO_x$ and $NO_x$ in a cylinder type corona discharge reactor and obtained more than 90 % of removal efficiency in these experimental conditions. The effects of process variables such as the inlet concentrations of $SO_x$, $NH_3$ and $H_2O$, residence time, pulse frequencies and applied voltages were investigated.

  • PDF

Formation of Ultra fine Particle by the Polonium-218 Ions under Different Humidity Conditions (다른 습도조건하에서 Po-218 이온들의 극소입자형성에 관한 연구)

  • Yoon, Suk-Chul;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.17 no.1
    • /
    • pp.1-10
    • /
    • 1992
  • A number of investigators have reported the formation of the radiolytic ultrafine particles produced by the interaction of ionizing radiation with water vapor. Previous studies have suggested that a very high localized concentration of the OH radical produced by the radiolysis of water can react with trace gas like organic vapors and produce lower vapor pressure compounds that can then nucleate. In order to determine water vapor dependence of the active, positively charged, first radon daughter(Po-218), an experiment was conducted using a well-controlled radon chamber. The activity size distribution of the radon daughter in the range of 0.5-100nm was measured using the parallel graded wire screens system. Measurements were taken for different relative humidity. The resultant activity size distributions were analyzed. The addition of water vapor to the radon carrier gases resulted in the formation of ultrafine particles by OH radicals formed by radon radiolysis. It may be due to the neutralization of charged Po-218 ion with water vapor through the radio lysis.

  • PDF

Comparison of Clinical Development and Evaluation of Triple Antihypertensive Therapy in Advanced Foreign Countries (항고혈압 약물 3종 복합제에 대한 선진 외국의 임상자료 심사사례 비교)

  • Wang, So Young;Shon, Soo Jung;Um, Jung Yoon;Lim, Hwa Kyung;Lim, Sook;Kang, Seung Ho;Lee, Sun Hee
    • Korean Journal of Clinical Pharmacy
    • /
    • v.23 no.3
    • /
    • pp.239-247
    • /
    • 2013
  • Background: Fixed drug combinations are formulations containing two or more active ingredients in a single dosage form. Such combination therapies are commonly applied to improve efficacy, reduce adverse events and replace co-administration, etc. National and international guidelines for hypertension treatment recommend addition of other classes of antihypertensive drugs rather than incremental dose of mono-therapy, when blood pressure is not adequately controlled. Thus, many dual combinations of antihypertensive drugs have been approved and pharmaceutical companies are recently interested in developing antihypertensive triple combinations. Clinical trial designs for the fixed combinations are various depending on the target patients, dosage and clinical endpoints. Thereby, further discussions for the clinical trials of antihypertensive triple therapies are required regarding the indication claimed. Conclusion: This article provides a review for the assessment of the label and medical reports of the clinical trials on antihypertensive triple therapies in advanced foreign countries.

A Trial for Improvement of Energy Efficiency of Plasma Reactor by Superposing Two Heterogeneous Discharges - Characteristics of Surface and Corona Discharge Combined Plasma Reactor - (이종방전 중첩에 의한 방전 플라스마반응기의 효율개선의 시도 - 연면.직류코로나 방전 중첩형 반응기의 특성 -)

  • ;Mizuki Yamaguma
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.3
    • /
    • pp.66-70
    • /
    • 2000
  • In order to cope with environmental problems caused by harmful gases emitted from various industrial sources, a new technology which employs discharge plasma formed in ordinary atmospheric pressure has been intensively investigated in many industrialized nations. Although a plenty of useful outcomes and suggestions have been made public by scientists in this field, few commercial products which effectively decompose pollutant gases have appeared as yet. This is partly because that the energy efficiency of a most effective plasma reactor has not reached a satisfactory level in comparison with those of devices using conventional technologies. In an attempt to solve the problem mentioned above, we noticed to combine heterogeneous electrical discharges. This concepts is based on that each plasma reactor has its specific spatial region in which chemical reaction are active and by electrically affected with another reactor of different type, the activated region would increase - which may lead to cutting down the energy consumption. To prove this concept experimentally, two different discharge equipments, a plane ceramic-based surface discharge electrode and a corona electrode with tungsten needle may, are selected and combined to fabricate a hybrid plasma reactor. The results are summarized as follows; (1) Ozone concentration generated in the plasma region drastically increases when the positive corona discharge is added to the surface discharge. The rate of increase of ozone depends on the frequency of the surface discharge. The negative corona, however, does not contribute to the improvement of the ozone generation. (2) NO(nitrogen monoxide) decomposition rate also improves by simultaneously applying the surface and the positive corona discharges. The effect of the corona superposition is more evident when the level of the surface discharge is moderate. (3) By adjusting the corona level, the net energy efficiency during NO decomposition improves in comparison with the simple surface discharge reactor.

  • PDF

Local Heat Transfer Coefficients for Reflux Condensation Experiment in a Vertical Tube in the Presence of Noncondensible Gas

  • Moon, Young-Min;No, Hee-Cheon;Bang, Young-Seok
    • Nuclear Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.486-497
    • /
    • 1999
  • The local heat transfer coefficient is experimentally investigated for the reflux condensation in a countercurrent flow between the steam-air mixture and the condensate, A single vertical tube has a geometry which is a length of 2.4m, inner diameter of 16.56mm and outer diameter of 19.05mm and is made of stainless steel. Air is used as a noncondensible gas. The secondary side has a shape of annulus around vertical tube and the lost heat by primary condensation is transferred to the coolant water. The local temperatures are measured at 11 locations in the vertical direction and each location has 3 measurement points in the radial direction, which are installed at the tube center, at the outer wall and at the coolant side. In three different pressures, the 27 sets of data are obtained in the range of inlet steam flow rate 1.348∼3.282kg/hr, of inlet air mass fraction 11.8∼55.0%. The investigation of the flooding is preceded to find the upper limit of the reflux condensation. Onset of flooding is lower than that of Wallis' correlation. The local heat transfer coefficient increases as the increase of inlet steam flow rate and decreases as the increase of inlet air mass fraction. As an increase of the system pressure, the active condensing region is contracted and the heat transfer capability in this region is magnified. The empirical correlation is developed by 165 data of the local heat transfer. As a result, the Jacob number and film Reynolds number are dominant parameters to govern the local heat transfer coefficient. The rms error is 17.7% between the results by the experiment and by the correlation.

  • PDF

Safety Evaluation of LB20304, a New Quinolone Antibiotic

  • Kim, Seong-Il;Kim, Hee-Jin;Kwak, Jin-Hwan;Kim, In-Chull;Lee, Chang-Ho
    • Biomolecules & Therapeutics
    • /
    • v.3 no.4
    • /
    • pp.322-326
    • /
    • 1995
  • General pharmacology of LB20304, a quinolone antibiotic, were examined in terms of general behaviour, cardiovascular, and central nervous system. LB20304 at oral dose of 2,000 mg/kg did not induce significant behavioural changes in mice. In contrast with ciprofloxacin, LB20304 at dose of 20 mg/kg, iv. did not show any observable effects on the blood pressure in rats. Displacement of [$^3$H]muscimol binding to the rat brain synaptic membranes was measured. LB20304 was shown to be about five times less potent than ciprofloxacin in specific GABA receptor binding. Drug interaction between LB20304 and 4-biphenyl acetic acid, an active metabolite of fenbufen, was assessed in mice by measuring convulsion and/or subsequent death. A single oral pretreatment with 4-BPA at 400 mg/kg increased the incidence of convulsion and death after oral administration of ciprofloxacin at the doses of 25, 50, and 100 from zero of five to three of five, two of five, and four of five, respectively, whereas LB20304 alone or combination with 4-BPA caused neither convulsions nor death at the doses of 12.5, 25, 50, and 100 mg/kg, respectively. Quinolones-induced epileptogenic activities were assessed by a direct intracerebral injection of test articles. The CD$_{50}$ values (nmole) are as follows; 169.47, 35.36, 105.29, and 88.67 for LB20304, ciprofloxacin, of loxacin, and lomefloxacin, respectively. From these data, LB 20304 at therapeutic doses seems to be much more safe than any other quinolones tested.d.

  • PDF

The Prevalence, Awareness, Treatment, and Control of Hypertension, and Related Factors in Rural Korea (농촌 지역의 고혈압 유병률, 관리 양상 및 그 관련요인)

  • Ha, Yong-Chan;Chun, Hyun-Ju;Hwang, Hae-Kyoung;Kim, Byung-Sung;Kim, Jang-Rak
    • Journal of Preventive Medicine and Public Health
    • /
    • v.33 no.4
    • /
    • pp.513-520
    • /
    • 2000
  • Objectives : To estimate the prevalence of hypertension, rates of awareness, treatment modalities, and control of hypertension, and also to identify factors in rural Korea that are related to these aspects of hypertension. Methods : A cross-sectional survey, including blood pressure(BP) measurements and interviews, investigating the variables in the health belief model was peformed from August to November, 1999 on 1,426 (79.4%) study subjects out of 1,797 registered residents over 30 years old in Ibansong-Myun, Chinju City. A second survey was peformed from January to March, 2000 on 376 (80.0%) subjects out of 470 hypertensive (or suspected hypertensive) subjects found in the first survey. Two BP readings were taken in each survey using a standard mercury sphygmomanometer. Hypertension was defined as either a BP reading $\geq$ 140/90 mmHg in both surveys, or as subjects on oral hypertensive medication. Results : Estimated hypertension prevalence was 24.9% for men, and 30.4% for women. Rates of hypertension awareness, treatment (the regular use of oral hypertensives), and control (reduction of BP to <140/90 mmHg) were 52.5%, 34.4%, and 12.9%, respectively. The factors related to lower hypertension awareness in the logistic regression analysis were male gender, farming occupation, and higher perceived barrier to medical treatment (those for whom visiting health professionals is a burden). Conclusions : To improve the low awareness, treatment, and control of hypertension, a more active and out-reaching hypertension control program, including routine BP measurements for every visitor to primary care facilities, is needed in rural Korea.

  • PDF

A Parameter Study on the Frequency Characteristics of the Structural-acoustic Coupled System (구조-음향 연성계의 경계값 변화에 따른 방사음 변화)

  • 김양한;서희선
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.7
    • /
    • pp.604-611
    • /
    • 2004
  • It is well known that wall impedance essentially determines how sound wave transmits from one place to another. The wall impedance is related with its dynamic properties : for example, the mass, stiffness, and damping characteristics. It is noteworthy, however, that the wall impedance is also function of spatial characteristics of two spaces that is separated by the wall. This is often referred that the wall is not locally reacting. In this paper, we have attempted to see how the acoustic characteristics of the two spaces is affected by various structure parameters such as density, applied tension, and a normalized length of the wall. Calculations are conducted for two different modally reacting boundary conditions by modal expansion method. The variation of the Helmholtz mode and the structural-dominated mode are analyzed as the structure parameters vary. The displacement distribution of the structure, pressure and active intensity of the inside and outside cavity are presented at the Helmholtz mode and the structure-dominated mode. It is shown that the frequency characteristics are governed by both structure-and fluid-dominated mode. The results exhibit that the density of the structure is the most sensitive design parameter on the frequency characteristics for the coupling system as we could imagine in the beginning. The Helmholtz mode frequency decrease as density increases. However. it increases as applied tension and an opening size increase. The bandwidth of the Helmholtz mode is mainly affected by density of the structure and its opening size.

A Study of Design of Hollow Fiber Membrane Modules for using in Artificial Lung by the PZT Actuator

  • Kim, Gi-Beum;Kim, Seong-Jong;Hong, Chul-Un;Lee, Yong-Chul;Kim, Min-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.4
    • /
    • pp.143-153
    • /
    • 2006
  • The purpose of this work was to assess and quantify the beneficial effects of gas exchange, while testingto the various frequencies of the sinusoidal wave that was excited by the PZT actuator, for patients suffering from acute respiratory distress syndrome (ARDS) or chronic respiratory problems. Also, this paper considered a simulator to design a hollow type artificial lung, and a mathematical model was used to predict a behavior of blood. This simulation was carried out according to the Montecarno's simulation method, anda fourth order Runge-Kutta method was used to solve the equation. The experimental design and procedure are then applied to the construction of a new device to assess the effectiveness of the membrane vibrations. As a result, the vibration method is very effective in the increase of gas transport. The gas exchange efficiency for the vibrating intravascular lung assist device can be increased by emphasizing the following design features: consistent and reproducible fiber geometry, and most importantly, an active means of enhancing convective mixing of water around the hollow fiber membranes. The experimental results showed the effective performance of the vibrating intravascular lung assist device. Also, we concluded that important design parameters were blood flow rates, fiber outer diameter and oxygen pressure drop. Based on the present results, it was believed that the optimal level of blood flow rates was 200$cm^3$/min.

Electrical and Optical Properties of Amorphous ITZO Deposited at Room Temperature by RF Magnetron Sputtering (RF 마그네트론 스퍼터링법으로 상온 증착된 비정질 ITZO 산화물의 전기적 및 광학적 특성)

  • Lee, Ki Chang;Jo, Kwang-Min;Lee, Joon-Hyung;Kim, Jeong-Joo;Heo, Young-Woo
    • Journal of the Korean institute of surface engineering
    • /
    • v.47 no.5
    • /
    • pp.239-243
    • /
    • 2014
  • The electrical and optical properties of amorphous In-Tin-Zinc-Oxide(ITZO) deposited at room temperature using rf-magnetron sputtering were investigated. The amorphous ITZO thin films were obtained at the composition of In:Sn:Zn = 6:2:2, 4:3:3, and 2:4:4, but the ITZO (8:1:1) showed a crystalline phase of bixbyite structure of In2O3. The resistivity of ITZO could be controlled by oxygen pressure in the sputtering ambient. The resistivity of post-annealed ITZO thin films exhibited the dependence on the amount of Indium. Optical energy band gap and transmittance increased as the amount of indium in ITZO increased. For the device application with ITZO, the bottom-gated thin-film transistor using ITZO as a active channel layer was fabricated. It showed a threshold voltage of 1.42V and an on/off ratio of $5.63{\times}10^7$ operated with saturation field-effect mobility of $14.2cm^2/V{\cdot}s$.