• Title/Summary/Keyword: acid detection

Search Result 1,327, Processing Time 0.032 seconds

Effect of Pre-treatments on the Content of Heavy Metals in Packaging Paper

  • Jo, Byoung-Muk;Jeong, Myung-Joon
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2006.06b
    • /
    • pp.465-469
    • /
    • 2006
  • Pre-treatment methods to determine various heavy metal contents in packaging papers were investigated by ICP-ES (Inductively Coupled Plasma Emission Spectrometry) analysis. Pre-treatment methods utilized in this study include dry ashing and decomposition methods ($HNO_{3-}HClO_{4-}HF,\;HNO_{3},\;and\;H_{2}SO_{4-}HNO_{3}$). They were compared with the conventional extraction (water) and migration (3% acetic acid) methods. The five representative heavy metals (Cd, As, Pb, Cr and Hg) were analyzed. For Cd, Hg, and As, the results were below detection limit of the instrument. In case of Cr and Pb, the migration test is considered to be a better method compared to the extraction test, but all pretreated methods showed much higher detection efficiency than the extraction or migration test. However, the detection ratio between the migration test and decomposition methods was different. Among all decomposition methods, the nitric acid - perchloric acid - hydrofluoric acid treatment brought a slightly higher detection value than others, but there was no significant difference among them except sulfuric acid - nitric acid method. Concerning Pb, the sulfuric acid - nitric acid method showed a low detection efficiency compared to other decomposition methods. The sulfuric acid - nitric acid method is, thus, not considered to be a suitable analysis method for Pb in packaging papers.

  • PDF

Review on CNT-based Electrode Materials for Electrochemical Sensing of Ascorbic Acid

  • P Mary Rajaitha;Runia Jana;Sugato Hajra;Swati Panda;Hoe Joon Kim
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.131-139
    • /
    • 2023
  • Ascorbic acid plays a crucial role in the regulation of neurotransmitters and enzymes in the central nervous system. Maintaining an optimal level of ascorbic acid, which is between 0.6-2 mg/dL, is vital for preventing oxidative stress and associated health conditions, such as cancer, diabetes, and liver disease. Therefore, the detection of ascorbic acid is of the utmost importance. Electrochemical sensing has gained significant attention among the various detection methods, owing to its simplicity, speed, affordability, high selectivity, and real-time analysis capabilities. However, conventional electrodes have poor signal response, which has led to the development of modified electrodes with better signal response and selectivity. Carbon nanotubes (CNTs) and their composites have emerged as promising materials for the electrochemical detection of ascorbic acid. CNTs possess unique mechanical, electrical, and chemical properties that depend on their structure, and their large surface area and excellent electron transport properties make them ideal candidates for electrochemical sensing. Recently, various CNT composites with different materials and nanoparticles have been studied to enhance the electrochemical detection of ascorbic acid. Therefore, this review aims to highlight the significance of CNTs and their composites for improving the sensitivity and selectivity of ascorbic acid detection. Specifically, it focuses on the use of CNTs and their composites in electrochemical sensing to revolutionize the detection of ascorbic acid and contribute to the prevention of oxidative stress-related health conditions. The potential benefits of this technology make it a promising area for future research and development.

Sample Preparation and Nucleic Acid-based Technologies for the Detection of Foodborne Pathogens (식중독균의 검출을 위한 시료전처리 및 핵산기반의 분석기술)

  • Lim, Min-Cheol;Kim, Young-Rok
    • Food Engineering Progress
    • /
    • v.21 no.3
    • /
    • pp.191-200
    • /
    • 2017
  • There have been great efforts to develop a rapid and sensitive detection method to monitor the presence of pathogenic bacteria in food. While a number of methods have been reported for bacterial detection with a detection limit to a single digit, most of them are suitable only for the bacteria in pure culture or buffered solution. On the other hand, foods are composed of highly complicated matrices containing carbohydrate, fat, protein, fibers, and many other components whose composition varies from one food to the other. Furthermore, many components in food interfere with the downstream detection process, which significantly affect the sensitivity and selectivity of the detection. Therefore, isolating and concentrating the target pathogenic bacteria from food matrices are of importance to enhance the detection power of the system. The present review provides an introduction to the representative sample preparation strategies to isolate target pathogenic bacteria from food sample. We further describe the nucleic acid-based detection methods, such as PCR, real-time PCR, NASBA, RCA, LCR, and LAMP. Nucleic acid-based methods are by far the most sensitive and effective for the detection of a low number of target pathogens whose performance is greatly improved by combining with the sample preparation methods.

Development of a nucleic acid detection method based on the CRISPR-Cas13 for point-of-care testing of bovine viral diarrhea virus-1b

  • Sungeun Hwang;Wonhee Lee;Yoonseok Lee
    • Journal of Animal Science and Technology
    • /
    • v.66 no.4
    • /
    • pp.781-791
    • /
    • 2024
  • Bovine viral diarrhea (BVD) is a single-stranded, positive-sense ribonucleic acid (RNA) virus belonging to the genus Pestivirus of the Flaviviridae family. BVD frequently causes economic losses to farmers. Among bovine viral diarrhea virus (BVDV) strains, BVDV-1b is predominant and widespread in Hanwoo calves. Reverse-transcription polymerase chain reaction (RT-PCR) is an essential method for diagnosing BVDV-1b and has become the gold standard for diagnosis in the Republic of Korea. However, this diagnostic method is time-consuming and requires expensive equipment. Therefore, Clustered regularly interspaced short palindromic repeats-Cas (CRISPR-Cas) systems have been used for point-of-care (POC) testing of viruses. Developing a sensitive and specific method for POC testing of BVDV-1b would be advantageous for controlling the spread of infection. Thus, this study aimed to develop a novel nucleic acid detection method using the CRISPR-Cas13 system for POC testing of BVDV-1b. The sequence of the BVD virus was extracted from National Center for Biotechnology Information (NC_001461.1), and the 5' untranslated region, commonly used for detection, was selected. CRISPR RNA (crRNA) was designed using the Cas13 design program and optimized for the expression and purification of the LwCas13a protein. Madin Darby bovine kidney (MDBK) cells were infected with BVDV-1b, incubated, and the viral RNA was extracted. To enable POC viral detection, the compatibility of the CRISPR-Cas13 system was verified with a paper-based strip through collateral cleavage activity. Finally, a colorimetric assay was used to evaluate the detection of BVDV-1b by combining the previously obtained crRNA and Cas13a protein on a paper strip. In conclusion, the CRISPR-Cas13 system is highly sensitive, specific, and capable of nucleic acid detection, making it an optimal system for the early point-of-care testing of BVDV-1b.

A Facile Electrochemical Fabrication of Reduced Graphene Oxide-Modified Glassy Carbon Electrode for Simultaneous Detection of Dopamine, Ascorbic Acid, and Uric Acid

  • Yu, Joonhee;Kim, Tae Hyun
    • Journal of Electrochemical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.274-281
    • /
    • 2017
  • This paper describes the simple fabrication of an electrode modified with electrochemically reduced graphene oxide (ERGO) for the simultaneous electrocatalytic detection of dopamine (DA), ascorbic acid (AA), and uric acid (UA). ERGO was formed on a glassy carbon (GC) electrode by the reduction of graphene oxide (GO) using linear sweep voltammetry. The ERGO/GC electrode was formed by subjecting a GO solution ($1mg\;mL^{-1}$ in 0.25 M NaCl) to a linear scan from 0 V to -1.4 V at a scan rate of $20mVs^{-1}$. The ERGO/GC electrode was characterized by Raman spectroscopy, Fourier transform infrared spectroscopy, contact angle measurements, electrochemical impedance spectroscopy, and cyclic voltammetry. The electrochemical performance of the ERGO/GC electrode with respect to the detection of DA, AA, and UA in 0.1 M PBS (pH 7.4) was investigated by differential pulse voltammetry (DPV) and amperometry. The ERGO/GC electrode exhibited three well-separated voltammetric peaks and increased oxidation currents during the DPV measurements, thus allowing for the simultaneous and individual detection of DA, AA, and UA. The detection limits for DA, AA, and UA were found to be 0.46, 77, and $0.31{\mu}M$ respectively, using the amperometric i-t curve technique, with the S/N ratio being 3.

Synthesis of 5-Aminolevulinic Acid (ALA) and Its t-Butyl Ester for the Fluorescence Detection of Early Cancer

  • Kang Min-Seok;Kim Dong-Myung;Kim Jeong Sook;Jeong Jin-Hyun
    • Archives of Pharmacal Research
    • /
    • v.28 no.10
    • /
    • pp.1111-1113
    • /
    • 2005
  • 5-Aminolevulinic acid and its derivatives, which are known to affect the early diagnosis and treatment of cancer, have been synthesized. Simple methods for the synthesis of 5-aminole-vulinic acid (ALA), a precursor of porphyrins, have been developed in our laboratory for use in studies on the biosynthesis of porphyrins.

Inhibitory Effects of Organic Acids against Pectinolytic Yeasts Isolated from Decayed Citrus (연부현상이 발생한 감귤로부터 분리한 효모에 대한 유기산의 생육 저해 효과)

  • Park, Eun-Jin;Kim, Soyeon
    • Korean journal of food and cookery science
    • /
    • v.31 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • Organic acids are known as natural sanitizers. We examined the sanitizing effects of five organic acids (acetic acid, propionic acid, citric acid, malic acid, and lactic acid) and their persistence on three pectinolytic yeast strains isolated from decayed citrus, and the persistence of their sanitizing effects was determined during storage at $4^{\circ}C$ and $16^{\circ}C$. The 7~8 log CFU/mL of the mixed three yeast mixture was exposed to various concentrations of each organic acid for 1 min. The yeast mixtures decreased under detection limit(1 log CFU/mL) in 1% of acetic acid, followed by in 3% of propionic acid with the reduction of 5 log CFU/mL. The citric acid, malic acid, and lactic acid decreased the number of yeasts under detection limit at 7.5%. When treated with deionized water and 1~5% of organic acids were treated on the surfaces of citrus contaminated by yeasts, total numbers of the yeasts decreased under detection limit(3 log CFU) at 5% of acetic acid and 4 log CFU/piece at 5% propionic acid compared with deionized water. When treated with acetic acid and propionic acid on the stem ends of the contaminated citrus, total numbers of the yeasts significantly decreased 0.5 log CFU/piece at 3% of both organic acids. During storage at $4^{\circ}C$ and $16^{\circ}C$ for 20 days, total number of yeasts significantly decreased at 2% acetic acid compared with deionized water. This study suggested that organic acids could be used to sanitize microbial contaminants from citrus for storage and transportation.

Simple Electrochemical Immunosensor for the Detection of Hippuric Acid on the Screen-printed Carbon Electrode Modified Gold Nanoparticles

  • Choi, Young-Bong;Tae, Gun-Sik
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.1
    • /
    • pp.44-49
    • /
    • 2011
  • This paper describes an electrochemical immunosensor for simple, fast and quantitative detection of a urinary hippuric acid which is one of major biological indicator in toluene-exposed humans. The feature of this electrochemical system for immunoassay of hippuric acid is based on the direct conjugation of ferrocene to a hippuric acid. With the competition between the ferrocene-hippuric acid complex and hippuric acid for binding to the anti-hippuric acid monoclonal antibody coated onto gold nanoparticles, the electrical signals are turned out to be proportional to urinary hippuric acid in the range of 0.01-10 mg/mL, which is enough to be used for the point-of-care. The proposed electrochemical method could extend its applications to detect a wide range of different small molecules of antigens in the health care area.

Quantitative Analysis of Heavy Metals in Packaging Papers

  • Jo, Byoung-Muk;Jeong, Myung-Joon
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.39 no.5
    • /
    • pp.45-51
    • /
    • 2007
  • This study was carried out to investigate various heavy metal contents in packaging papers by pre-treatments for ICP-ES (Inductively Coupled Plasma Emission Spectrometry) analysis. Pre-treatment methods of heavy metals in this study include extraction, migration and decomposition methods (dry ashing, $HNO_3-HClO_4-HF,\;HNO_3,\;and\;H_2SO_4-HNO_3$). Test results were compared with conventional extraction (water) and migration (3% acetic acid) methods. The five representative heavy metals (Cd, As, Pb, Cr and Hg) were analyzed. For Cd, Hg, and As, the results were below detection limit of the instrumental technique. It was considered that the migration test was a better method compared to extraction test, but all the decomposition methods showed much higher detection values than the extraction or migration test. In case of recycled corrugated containers, 3% acetic acid solution extracted about 25% of chromium and 30% of lead compared to the content by decomposition methods. Among all decomposition methods, the nitric acid - perchloric acid - hydrofluoric acid treatment brought a slightly higher detection value than others, but there was no significant difference among them except sulfuric acid - nitric acid method.

Development of Indocyanine Green and 5-Aminolevulinic Acid Detection System for Surgical Microscope (수술현미경용 다중형광 관측 시스템 연구)

  • Kim, Hong Rae;Lee, Hyun Min;Yoon, Woong Bae;Kim, Young Jae;Kim, Seok Ki;Yoo, Heon;Joo, Jae Young;Kim, Kwang Gi;Lee, Seung-Hoon
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.1
    • /
    • pp.16-21
    • /
    • 2015
  • Indocyanine green(ICG) and 5-aminolevulinic acid(5-ALA) have been widely used to mark blood vessels or tumors. However, fluorescent dye detection systems were designed to use one type of dyes only. In this study, we proposed a detection system capable of detecting Indocyanine green and 5-aminolevulinic acid. Multiple filters and light sources are integrated into a single system. In this study, we performed analysis of fluorescent dyes and configured a detection system. During the analysis, it was found that Indocyanine green and 5-aminolevulinic acid have the maximum intensity at $40{\mu}M$. We designed light source for fluorescent dyes and conducted compatibility test using a commercial surgical microscope. The fluorescent dye detection system was configured based on the experimental results. The developed system successfully detects Indocyanine green and 5-aminolevulinic acid. Therefore, more efficient surgical operations can be achieved using both fluorescent dyes at the same time. We expect that the developed system can increase the survival rate of patients.