• Title/Summary/Keyword: accidental fire

Search Result 65, Processing Time 0.029 seconds

A Study on the Establishment of the Framework Apportion Ratio in Calculating Damages due to Accidental Fires (화재의 실화배상책임액 산정을 위한 프레임워크 수립에 관한 연구)

  • Song, Kwang-Suk;Park, Chung-Hwa
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.190-203
    • /
    • 2019
  • Since the amendment of the Accidental Fire Liability Act in 2009, interested parties in accidental fire liability contracts have settled issues associated with the estimation of each other's liability amounts through lawsuits. As fire accidents are complex in nature, it is difficult to distinguish between direct and additional damages caused by extended combustion while calculating liability amounts for accidental fires. Additionally, there is an increasing need for establishing and using a framework that includes validity and reliability. To establish such a framework for estimating the liability amounts in case of an accidental fire, this study suggests a novel categorization of fires to be applied to the framework. This will be organized by the subjects of the liability of accidental fires, and quantified and probabilistic processed qualitative items through the methods applied to quantification (AMEA/FTA) based on the fire statistics data published by the government and the previous researchers' research application data and results.

A Study on the methodology analyzing the the role of the fire extinguisher (소화기의 역할 고찰을 통한 활용 방안 연구)

  • Baek, Myoung-Gi;Sun, Eun-Su;Song, Jae-Soo;Cho, Won-Cheol;Lee, Tae-Shik
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.518-521
    • /
    • 2007
  • The paper is to show the methodology that they have a new understanding of a fire extinguisher's function and utilization through a deeper look. This new approach method will help to extinguish a accidental fire practically

  • PDF

A study on fire design accidental loads for aluminum safety helidecks

  • Kim, Sang Jin;Lee, Jin;Paik, Jeom Kee;Seo, Jung Kwan;Shin, Won Heaop;Park, Joo Shin
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.6
    • /
    • pp.519-529
    • /
    • 2016
  • The helideck structure must satisfy the safety requirements associated with various environmental and accidental loads. Especially, there have been a number of fire accidents offshore due to helicopter collision (take-off and/or landing) in recent decades. To prevent further accidents, a substantial amount of effort has been directed toward the management of fire in the safety design of offshore helidecks. The aims of this study are to introduce and apply a procedure for quantitative risk assessment and management of fires by defining the fire loads with an applied example. The frequency of helicopter accidents are considered, and design accidental levels are applied. The proposed procedures for determining design fire loads can be efficiently applied in offshore helideck development projects.

A Study on Enhancing Institutionalization on the Fire Analysis of the Warehouse at Icheon City (이천 냉동창고 화재분석을 통한 제도개선방안 연구)

  • Jung, Tae-Ho;Park, Sang-Hyun;Kim, Hee-Kyu
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.80-84
    • /
    • 2008
  • This research has been carried out in order to provide countermeasure plans, fire prevention, improving institutional plans through analyzing accidental causes and investigating the situation of damage from the fire incident of the cold storage at Icheon. By the analysis of the incident, which is organized the process; for incidence, firstly a field investigation, next the overview of related laws, finally the analysis of problems and deducting suggestions, it was possible to find out the causes of casualties. We also suggested improving plans through finding out several problems such as safety management system and safety regulations, the permit on the completion of the cold storage and the completion examination of fire facilities as institutional problems and fireproof construction and the selection of finishing materials.

  • PDF

A Case of Sprinkler Non-Working by Programming Error (프로그래밍 오류에 의한 스프링클러 미작동 사례)

  • Seo, Young-Il;Cho, Young-Jin;Moon, Byung-Seon;Park, Jong-Jin;Park, Jong-Chan;Park, Nam-Kyu
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.116-120
    • /
    • 2008
  • According to the Fire Services Act revised in 2005, it has been required to set up sprinkler systems to all floors to the newly builded apartments having above 11 floors. But, according to the Fire Services Act before 2005, it had been required to set up sprinkler systems from 16 floors to the top floors to the apartments having above 16 floors. This case is the accident that a victim was dead by the fire which is inferred as an accidental fire by a cigarette butt in a 17th floor apartment unit in an apartment having 17th floors and that the bereaved family called in question why the sprinklers non worked at the fire. Through the field investigation, we checked that the sprinklers worked well when the fire detectors at the 16th floor of the apartment were operated and that the sprinklers non worked when the fire detectors at the 17th floor of the apartment were operated. We made clear that the cause of the sprinkler non-working at the 17th floor is the programming error of the sprinkler controller.

Structural Response of Offshore Plants to Risk-Based Blast Load

  • Heo, YeongAe
    • Architectural research
    • /
    • v.15 no.3
    • /
    • pp.151-158
    • /
    • 2013
  • Offshore oil and gas process plants are exposed to hazardous accidents such as explosion and fire, so that the structural components should resist such accidental loads. Given the possibilities of thousands of different scenarios for the occurrence of an accidental hazard, the best way to predict a reasonable size of a specific accidental load would be the employment of a probabilistic approach. Having the fact that a specific procedure for probabilistic accidental hazard analysis has not yet been established especially for explosion and fire hazards, it is widely accepted that engineers usually take simple and conservative figures in assuming uncertainties inherent in the procedure, resulting either in underestimation or more likely in overestimation in the topside structural design for offshore plants. The variation in the results of a probabilistic approach is determined by the assumptions accepted in the procedures of explosion probability computation, explosion analysis, and structural analysis. A design overpressure load for a sample offshore plant is determined according to the proposed probabilistic approach in this study. CFD analysis results using a Flame Acceleration Simulator, FLACS_v9.1, are utilized to create an overpressure hazard curve. Moreover, the negative impulse and frequency contents of a blast wave are considerably influencing structural responses, but those are completely ignored in a widely used triangular form of blast wave. An idealistic blast wave profile deploying both negative and positive pulses is proposed in this study. A topside process module and piperack with blast wall are 3D FE modeled for structural analysis using LS-DYNA. Three different types of blast wave profiles are applied, two of typical triangular forms having different impulse and the proposed load profile. In conclusion, it is found that a typical triangular blast load leads to overestimation in structural design.

Simulation and Damage Analysis of an Accidental Jet Fire in a High-Pressure Compressed Pump Shelter

  • Jang, Chang Bong;Choi, Sang-Won
    • Safety and Health at Work
    • /
    • v.8 no.1
    • /
    • pp.42-48
    • /
    • 2017
  • Background: As one of the most frequently occurring accidents in a chemical plant, a fire accident may occur at any place where transfer or handling of combustible materials is routinely performed. Methods: In particular, a jet fire incident in a chemical plant operated under high pressure may bring severe damage. To review this event numerically, Computational Fluid Dynamics methodology was used to simulate a jet fire at a pipe of a compressor under high pressure. Results: For jet fire simulation, the Kemeleon FireEx Code was used, and results of this simulation showed that a structure and installations located within the shelter of a compressor received serious damage. Conclusion: The results confirmed that a jet fire may create a domino effect that could cause an accident aside from the secondary chemical accident.

Application and evaluation of machine-learning model for fire accelerant classification from GC-MS data of fire residue

  • Park, Chihyun;Park, Wooyong;Jeon, Sookyung;Lee, Sumin;Lee, Joon-Bae
    • Analytical Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.231-239
    • /
    • 2021
  • Detection of fire accelerants from fire residues is critical to determine whether the case was arson or accidental fire. However, to develop a standardized model for determining the presence or absence of fire accelerants was not easy because of high temperature which cause disappearance or combustion of components of fire accelerants. In this study, logistic regression, random forest, and support vector machine models were trained and evaluated from a total of 728 GC-MS analysis data obtained from actual fire residues. Mean classification accuracies of the three models were 63 %, 81 %, and 84 %, respectively, and in particular, mean AU-PR values of the three models were evaluated as 0.68, 0.86, and 0.86, respectively, showing fine performances of random forest and support vector machine models.

A study on the burned pattern of plastic wastebasket by reconstruction (플라스틱 휴지통의 연소 재현 실험을 통한 발화지점 축소 방법)

  • An, Seong-Il
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.3 no.1
    • /
    • pp.38-42
    • /
    • 2003
  • There are many origins of fire which are offered by many path, such as cigarette-butt, light of match, playing with fire, arson, and other, in and around wastebasket. Because of above-mentioned thing and the quality of the plastic, it is very difficult to discriminate the difference of burned pattern between in and around wastebasket, between an accidental fire and arson in oder to investigate the point of fire. In this study, the wastebaskets filled up with 2/3 combustibles, and then, in and around wastebasket using the gas lighter by ignitor, and we observe how the fire spread. As a result, if wastebaskets are burned inside the limit 50%, we discriminate the difference of burned pattern between in and around wastebasket. But, if wastebaskets are burned more thant 50%, it is impossible to discriminate the difference of burned pattern between in and around wastebasket.

  • PDF

Strategy about Support System for Victims of Fire Cases through the Analysis of A Fire Cases (화재사례분석을 통한 화재피해자 지원체계 구축방안)

  • Cha, Jong-Ho
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.4
    • /
    • pp.196-202
    • /
    • 2018
  • There have been more than 40,000 cases of fires in Korea in the last three years. However, as 'Accidental Fire Liability Act' was judged to be non-conform to the Constitution in 2007, the damages by light mistakes should be compensated. Accordingly, disputes such as compensation claims, litigations and indemnification cases of the victims of fire increased. However, it is so difficult for victims of fire cases to take proper action. So, this study is to help victims of fire cases in the disputes and compensation claims of the victims, and to find actual and practical support system based on the analysis of compensation status. To help victims of fire cases, we need to survey about victims of fire cases with multiple victims. That survey is analyzed to find support plan for victims. Furthermore, to find support plan the current law is needed to be analyzed and reviewed to revision. It is also tried to identify problems in the operation of the Center for victims of Fire currently operated by fire stations and to find countermeasures. In addition, the status of subscription and problem of fire insurance for the compensation for the victims and the method to increase fire insurance subscription rate will be studied.