• 제목/요약/키워드: a frequency response

검색결과 4,789건 처리시간 0.038초

2차원 디지털 필터의 반복실현에 관한 연구 (A Study on the Iterative Implementation of 2-D Digital Filter)

  • 장태용;이윤현
    • 한국통신학회:학술대회논문집
    • /
    • 한국통신학회 1984년도 추계학술발표회논문집
    • /
    • pp.82-87
    • /
    • 1984
  • A 2-D digital filter with rational frequency response can be expanded into an infinite sequence of filterins operations. Each filtering operation can be implemented by convolution with a Low-order 20D finite-extent impulse response. If a convergence constraint is satisfied, the sequence of estimates will approach the desired output signal. In practice, as the number of iterations is finite, the frequency response implemented by iterative computations is an approximation to the desired rational frequency response.

  • PDF

다축 로드 시뮬레이터를 이용한 대형트럭 주요 시스템의 바운스와 롤 및 피치 주파수의 실험적 분석 (Experimental Analysis of Bounce, Roll and Pitch Frequencies of Major Systems of a Large Truck using a Multi-axial Road Simulator)

  • 문일동;오재윤
    • 한국정밀공학회지
    • /
    • 제22권8호
    • /
    • pp.128-135
    • /
    • 2005
  • This paper presents a scheme for experimentally analyzing bounce, roll and pitch frequencies of major systems of a large truck using a multi-axial road simulator. The excitation input (amplitude and frequency range) fur a frequency response test with the multi-axial road simulator is selected in order that bounce, roll and pitch modes are not coupled each other, the excitation amplitude can be reproduced in a specified excitation frequency range, and tires do not lose contact with posters. Three accelerometers, one gyroscope and four displacement meters are used in the frequency response test using the multi-axial road simulator. The reliability of the presented bounce mode frequency response test scheme is validated by comparing the result from a test using the multi-axial road simulator with the result from a road driving test. The road driving test is performed with velocities of 20km/h and 30km/h, and in an unladen state. The vertical accelerations at the cab and the front axle are measured in the road driving test. The roll and pitch mode frequency response tests are also performed with the presented frequency response test scheme. Roll and pitch frequencies of major systems of a large truck that are hard to acquire from a road driving test are analyzed as well as bounce frequency.

진동-음향 연성계의 모드특성에 대한 연구 (A Study on the Modal Characteristics of the Vibration-Acoustic Coupled System)

  • 김석현
    • 산업기술연구
    • /
    • 제16권
    • /
    • pp.239-245
    • /
    • 1996
  • Modal parameters determine the frequency response characteristics of vibration system or acoustic system. When the two systems are fully coupled, however, coupling changes the vibrational and acoustic model parameters into those of the coupled system. In this case, it is very difficult to obtain the modified model parameters and response characteristics. In this paper, coupling effect is analytically investigated on the natural frequency, mode and frequency response characteristics. The result can be applied to understand and to design the frequency response characteristics of the vehicle passenger compartment.

  • PDF

Effects of the Insulation Quality on the Frequency Response of Power Transformers

  • Abeywickrama Nilanga;Ekanayake Chandima;Serdyuk Yuriy V.;Gubanski Stanislaw M.
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권4호
    • /
    • pp.534-542
    • /
    • 2006
  • This paper presents results of frequency domain spectroscopy (FDS) measurements on oil-impregnated pressboard insulation, their analyses and use of the data for modeling high frequency response (FRA) of transformers. The dielectric responses were measured in a broad frequency range, i.e. from 0.1 mHz to 1 MHz, on model samples containing different amount of moisture. The responses were parameterized with terms representing dc conductivity, low frequency dispersion and Cole-Cole polarization mechanisms and they were thereafter used to model the FRA response of a three-phase transformer.

국내 지진센서의 저주파 응답의 신뢰성에 관한 고찰 (Review on the reliability of low frequency responses of locally operating sensors)

  • 박동희;연관희;장천중
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.35-42
    • /
    • 2002
  • Frequency responses for most of the local seismic sensors in Korea have been roughly checked by mutual comparison of Fourier spectra of seismic records from accelerometer and seismometer, both of which are installed at the same location. Especially, because the frequency content of the seismic energy is usually above 1 Hz for local earthquakes, the reliability of low frequency response could have not been evaluated. Fortunately a recent large earthquake, Ms=7.2 on 02/06/29 containing dominant low frequency energy makes it possible to check the low frequency response of the seismic sensors, especially EpiSensor and JC-V100. Considering two types of sensor pairs, (STS-2 and EpiSensor, JC-V100 and EpiSensor), the low frequency response of EpiSensor is confirmed first by comparison with STS-2 which has proved low frequency response. Second, reliable low frequency limit of instrumentally corrected seismic data from JC-V100 data is estimated to be about 0.03 Hz by comparison with EpiSensor data.

  • PDF

상부 돔구조와 하부구조간의 고유진동수비에 따른 동적응답특성 (Dynamic Response Property according to Natural Frequency Ratio between Dome Structure and Substructure)

  • 이영락;김광일;강주원
    • 한국공간구조학회논문집
    • /
    • 제15권2호
    • /
    • pp.113-120
    • /
    • 2015
  • This study investigate the dynamic response changes of rib dome structure according to property changes of Substructure. Eigenvalue analysis is conducted in first natural frequency of rib dome versus substructure and searched in the dominant mode of horizontal and vertical direction. Resonance frequency by each first natural frequency of the rib dome structure, substructure and total structure is applied for a seismic wave. That is analyzed about maximum displacement response ratio and maximum acceleration response ratio.

주파수영역방법에 의한 비선형 모델변수의 실험적 규명 (Experimental identification of nonlinear model parameter by frequency domain method)

  • 김원진
    • 대한기계학회논문집A
    • /
    • 제22권2호
    • /
    • pp.458-466
    • /
    • 1998
  • In this work, a frequency domain method is tested numerically and experimentally to improve nonlinear model parameters using the frequency response function at the nonlinear element connected point of structure. This method extends the force-state mapping technique, which fits the nonlinear element forces with time domain response data, into frequency domain manipulations. The force-state mapping method in the time domain has limitations when applying to complex real structures because it needd a time domain lumped parameter model. On the other hand, the frequency domain method is relatively easily applicable to a complex real structure having nonlinear elements since it uses the frequency response function of each substurcture. Since this mehtod is performed in frequency domain, the number of equations required to identify the unknown parameters can be easily increased as many as it needed, just by not only varying excitation amplitude bot also selecting excitation frequency domain method has some advantages over the classical force-state mapping technique in the number of data points needed in curve fit and the sensitivity to response noise.

부분 구조의 주파수 응답 함수를 이용한 봉의 치수 최적화 (Size Optimization of a Rod Using Frequency Response Functions of Substructures)

  • 윤홍근;이진우
    • 대한기계학회논문집A
    • /
    • 제41권10호
    • /
    • pp.905-913
    • /
    • 2017
  • 본 연구에서는 형상 정보가 주어지지 않은 부품과 형상 정보가 주어진 부품으로 구성된 봉의 고유 주파수를 최대화하는 치수 최적화 방법을 제시한다. 두 부품으로 구성된 봉의 진동 특성을, 각 부품의 형상 대신, 두 부품의 주파수 응답 함수들로부터 예측한다. 이를 위해, 실험 모달 해석 방법을 이용하여 각 부품의 등가 진동계를 구하고, 두 등가 진동계의 질량 행렬과 강성 행렬들로부터, 두 부품이 결합된 봉의 등가 질량 행렬과 강성 행렬을 도출한다. 몇 가지 수치 예제에서, 제시한 방법으로 얻어진 봉의 등가 진동계의 주파수 응답 함수를 실제 봉의 주파수 응답 함수와 비교하여, 등가 진동계를 이용한 고유 주파수 예측 방법의 유효성을 검증한다. 검증된 방법으로 얻어진 등가 진동계를 이용하여, 봉의 1차 고유 주파수를 최대화하기 위한 치수 최적화 문제를 정식화하고, 최적화 알고리즘을 사용하여 봉의 구조를 최적화한다.

On Power System Frequency Control in Emergency Conditions

  • Bevrani, H.;Ledwich, G.;Ford, J. J.;Dong, Z.Y.
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.499-508
    • /
    • 2008
  • Frequency regulation in off-normal conditions has been an important problem in electric power system design/operation and is becoming much more significant today due to the increasing size, changing structure and complexity of interconnected power systems. Increasing economic pressures for power system efficiency and reliability have led to a requirement for maintaining power system frequency closer to nominal value. This paper presents a decentralized frequency control framework using a modified low-order frequency response model containing a proportional-integral(PI) controller. The proposed framework is suitable for near-normal and emergency operating conditions. An $H_{\infty}$ control technique is applied to achieve optimal PI parameters, and an analytic approach is used to analyse the system frequency response for wide area operating conditions. Time-domain simulations with a multi-area power system example show that the simulated results agree with those predicted analytically.

Territory Defense Strategy of the Wrinkled Frog, Rana rugosa

  • Park, Shi-Ryong;Cheong, Seokwan
    • The Korean Journal of Ecology
    • /
    • 제25권1호
    • /
    • pp.25-28
    • /
    • 2002
  • The advertisement call of anurans functions to attract potential mates. The dominant frequency of an advertisement call is generally getting lower with increased snout-vent length (SVL) of the caller Rana rugosa has an advertisement call tilth a particularly high frequency modulation. We conducted a playback experiment to verify the function of frequency modulation, and investigated the territorial behavior of the frog. The frog has five types of territory defense strategy. Strategy choice depended on the caller's SVL. Small males became satellites or lowered the dominant frequency of their advertisement call, whereas large males actively defended their territory with encounter calls. In response to high frequency (1107 Hz) playback, the frogs lowered their advertisement call frequency, and towered them further in response to the low frequency (1028 Hz) playback. In addition, the number of pulses in a call was increased in response to the playback. These results indicate that the frog avoids physical conflict with competitors by selecting a territory defense strategy suitable for the caller's size, and by lowering its call frequency to disguise its SVL.