• Title/Summary/Keyword: a feasibility

Search Result 10,411, Processing Time 0.043 seconds

Study on Amenity and Economical Efficiency of Multi-functionality on the Grassland (초지형 축산의 어메니티 및 경제성 평가에 관한 연구)

  • Cheon, D.W.;Lee, S.Y.;Park, M.S.;Park, H.S.;Hwang, K.J.;Yun, S.H.;Ko, M.S.
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.27 no.4
    • /
    • pp.297-312
    • /
    • 2007
  • This study is conducted to evaluate economical value of Jeju grassland and validity of its preservation, and draw up several measures to support. To measure its economical value, this study examined its environmental value and social and cultural value. For environmental value, this study used replacement method while it applied CVM method, a widely used method, to assess social and cultural value and two-level two-best choice selection method, which ask questions by assuming virtual circumstances to avoid reflecting some biased opinions. Jeju grassland has multiple functions-environmental functions such as preventing soil corrosion and flood, handling animal excrement, and purifying air, and social and cultural functions such as promoting physical and mental health and providing recreation places. From the results of the feasibility study, Jeju grassland's annual multiple functions are assessed to have a total $397,115{\sim}418,995$ million won worth. In addition, it is found that Jeju visitors recognize Jeju grassland for its functions to contribute to public interests. That is, they think it can provide attractive views and educational and recreational places and promote emotional development. Especially, many people presented their ideas that it be continuously preserved since it is worthwhile for us and our next generations. To preserve grassland's cultural resource, which create a huge economic value like this, the Government has to support a certain amount of financial aid for turning to a better grassland environment and its maintenance to realize environment-friendly livestock farming on Jeju Island and promote its tourism industry and consequently, add more value to Jeju.

A Comparative Study on the Measurement Model of Anti-Corruption Index : Anti-Corruption Index and CCEJ's Corruption Index (부패지수 측정모형에 대한 비교연구 : 서울시 시정청렴성지수 측정모형과 경실련 부패지수 측정모형을 중심으로)

  • Park, Yong-Chie;Lee, Chung-Min
    • Survey Research
    • /
    • v.6 no.1
    • /
    • pp.1-38
    • /
    • 2005
  • Considering the importance of corruption index measurement model and the diffusion of popular awareness about the importance of anti-corruption, this research compared and analyzed existing corruption index measurement models. This paper has selected "Anti-Corruption Index model(ACI model)" that was developed by Seoul Development Institute and "CCEJ's Corruption Index model" which is under use by the Citizens' Coaltion for Economic Justice. These two models were analyzed in terms of appropriateness of 'the indicator and index choice method', 'the research design' and 'the use of statistical data'. This analysis shows that two models have some problems. First, at the level of indicator and index choice method, the indicators of CCEJ's corruption index model is too atomized and redundant. As not putting weight of indicator, it did not consider importance of each indicator. Citizens who evaluated the level of corruption didn't participate in the weight evaluation team, which results in failure of the model to reflect the citizens' opinion. Also, because the question about Seoul Metropolis' corruption level is not included, it is not detected difference between real corruption level and perceptive corruption level. Second, in terms of appropriateness of research design, the sample of the CCEJ' corruption index model is too small to get credibility. The objectivity of research method seems to be low because survey was performed by exit interview. In addition, 38 items are overfull in the questionnire of CCEJ's corruption index model compare to 13 items in ACI model. Also, in making up questions, the terms are redundant and unobvious. Third, in regarding with feasibility of the statistical data, the CCEJ's corruption index model uses regulation data for disciplinary punishment of 25 local governments in Seoul from 1995 to 1999. But, it is common ideas of scholars that statistical data indicates the tip of an iceberg in corruption. So for using a statistical data, it needs a data of enough quantity and has a high level credibility. In addition, objective method of giving weight is not developed. In this point of view, the use of statistical data has some limits. To solve this problem, ① objective data should be included in the indicators, ② various indicators should be developed and ③ a method of giving weight should be improved.

  • PDF

SOFT TISSUE PROFILE CHANGE PREDICTION IN MAXILLARY INCISOR RETRACTION BASED ON CEPHALOMETRICS (두부방사선 분석에 의한 상악전치부 후방이동시 연조직 변화 예측에 대한 연구)

  • Choi, Jin-Hee;Lee, Jin-Woo;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.65-78
    • /
    • 1997
  • This study was carried out in order to determine soft tissue response to incisor movement and mandibular repositioning and to determine feasibility of predicting vertical and horizontal changes in soft tissue with hard tissue movement. For this study, cephalometric records of 41 orthodontically treated adult females who had Angle's Class II division 1 malocclusion were selected and stepwise multiple regression analysis was employed. Following conclusions were obtained by analysing the changes of soft tissue and hard tissue before and after treatment. 1. Hard tissue measurements that showed significant changes before and after treatment were horizontal and angular changes of maxillary incisor, horizontal,vertical and angular changes of mandibular incisor, overjet, overbite, interincisal angle, mandibular repositioning, A,B, skeletal convexity and soft tissue measurements that showed significant changes were horizontal, thickness and angular changes of upper lip, horizontal and angular changes of lower lip, interlabial angle, nasolabial angle labiomental angle, Sri, Ss, Si and soft tissue convexity(P<0.05). 2. All Soft tissue measurements changed significantly before and after treatment had between one and four hard tissue independent variables at statistically significant level, indicating that all soft tissue changes were direct relationship with hard tissue changes 3. Ova jet, horizontal change of maxillary incisor, horizontal change of maxillary root apex and horizontal change of pogonion entered into prediction equations most frequentely indicating that they were more significant variables in prediction of vertical and horizontal changes in the soft tissue with treatment, but vertical changes of mandibular incisor not entered any prediction equations, indicating that it was not considered a good predictor for soft tissue changes with maxillary incisor retraction. 4. Horizontal and vertical changes in subnasale were found to have most independent variables, significant at the 0.05 level in prediction-equations(${\Delta}$Sn(H):Ur, Is(H), Pg(H), UIA,${\Delta}$Sn(V): Is(H), Pg(H), overjet, A), indicating that subnasale changes are influenced by complex hard tissue interaction. 5. Multiple correlation coefficient($R^2$) of the soft tissue prediction equations ranges from 0.2-0.6.

  • PDF

An Economic Analysis of the Effluent Heat Supply from Thermal Power Plant to the Farm Facility House (화력발전소 온배수열 활용 시설하우스 열공급 모형 경제성분석 연구)

  • Um, Byung Hwan;Ahn, Cha Su
    • Korean Chemical Engineering Research
    • /
    • v.56 no.1
    • /
    • pp.6-13
    • /
    • 2018
  • Utilizing the heat of cooling water discharge of coal-fired power plant, pipeline investment costs for businesses that supply heat to agricultural facilities near power plants increase in proportion to installation distance. On one hand, the distance from the power plant is a factor that brings difficulties to secure economic efficiency. On the other, if the installation distance is short, there is a problem of securing the heating demands, facility houses, which causes economical efficiency to suffer. In this study, the economic efficiency of 1km length of standard heat pipeline was evaluated. The sensitivity of the heat pipe to the new length variation was analyzed at the level of government subsidy, amount of heating demand and the incremental rate of pipeline with additional government subsidy. As a result of the analysis, it was estimated that NPV 131 million won and IRR 15.73%. The sensitivity analysis showed that NPV was negative when the length of heat pipe facility exceeded 2.6 km. If the government supports 50% of the initial investment, the efficiency is secured within the estimated length of 5.3 km, and if it supports 80%, the length increases within 11.4 km. If the heat demand is reduced to less than 62% at the new length of the standard heat pipe, it is expected economic efficiency is not obtained. If the ratio of government subsidies to initial investment increases, the elasticity of the new bloc will increase, and the fixed investment, which is the cost of capital investment for one unit of heating demand, will decrease. This would result in a reduction in the cost of production per unit, and it would be possible to supply heat at a cheaper price level to the facility farming. Government subsidies will result in the increased economic availability of hot plumbing facilities and additional efficiencies due to increased demand. The greater government subsidies to initial investment, the less farms cost due to the decrease in the price per unit. The results of the study are significant in terms of the economic evaluation of the effectiveness of the government subsidy for the thermal power plant heat utilization project. The implication can be applied to any related pilot to come.

Is a Fast-track Critical Pathway Possible in Gastric Cancer Surgery? (위암 수술 후 조기회복을 위한 임상진료 지침서의 활용이 가능한가?)

  • Yi, Jeong-Min;Hur, Hoon;Kim, Sung-Keun;Song, Kyo-Young;Chin, Hyung-Min;Kim, Wook;Park, Cho-Hyun;Park, Seung-Man;Lim, Keun-Woo;Jeon, Hae-Myung
    • Journal of Gastric Cancer
    • /
    • v.9 no.1
    • /
    • pp.18-25
    • /
    • 2009
  • Purpose: The postoperative hospital stay after gastric cancer surgery is usually 8 to 14 days. The main reason for a prolonged hospital stay may be the 3 to 4 day period of postoperative starvation. The aim of this study is to investigate the feasibility of a critical pathway for early recovery after gastric cancer surgery, and this pathway included early postoperative feeding. Materials and Methods: One hundred three consecutive patients who underwent gastric resection and reconstruction for gastric cancer from October 2007 to June 2008 at St. Mary's Hospital were prospectively enrolled in a fast-track critical pathway. The pathway included minimal preoperative procedures, optimal pain relief, proper fluid administration, early mobilization and early enteral nutrition at postoperative 1 day. The exclusion criteria were determined preoperatively, intraoperatively and postoperatively. Results: Of the 103 patients, 19 patients were excluded for preoperative (5), intraoperative (7) and postoperative (7) reasons. Eighty-four patients (81.6%) were included in the fast-track critical pathway. Sixty-eight (88.6%) of 84 patients were discharged at the planned 8 day after surgery during the initial period of the study, and the postoperative hospital stay was shortened up to 6 days during the more recent period. Postoperative complications occurred in 22 patients (26.2%), and these were gastrointestinal track-related complications in 6 cases (3 cases of ileus, 1 case of stasis and 2 cases of leakage) and infection-related complications in 8 cases. There was no statistical difference in the incidence of morbidity according to the clinic-operative features that included age, gender, stomach resection and lymphadenectomy. Conclusion: The fast-track critical pathway with using the available exclusion criteria was a valid option for patients who underwent gastric cancer surgery.

  • PDF

Arsenic Removal Using Iron-impregnated Ganular Activated Carbon (Fe-GAC) of Groundwater (철침착 입상활성탄(Fe-GAC)을 이용한 지하수 내 비소 제거기술)

  • Yoon, Ji-Young;Ko, Kyung-Seok;Yu, Yong-Jae;Chon, Chul-Min;Kim, Gyoo-Bum
    • Economic and Environmental Geology
    • /
    • v.43 no.6
    • /
    • pp.589-601
    • /
    • 2010
  • Recently it has been frequently reported arsenic contamination of geologic origin in groundwater. The iron-impregnated ranular activated carbon (Fe-GAC) was developed for effective removal of arsenic from groundwater n the study. Fe-GACs were prepared by impregnating iron compounds into a supporting medium (GAC) with 0.05 M iron nitrate solution. The materials were used in arsenic adsorption isotherm tests to know the effect of iron impregnation time, batch kinetic tests to understand the influence of pH, and column tests to evaluate for the preliminary operation of water treatment system. The results showed that the minimum twelve hours of impregnation time were required for making the Fe-GAC with sufficient iron content for arsenic removal, confirmed by a high arsenic adsorption capacity evaluated in the isotherm tests. Most of the impregnated iron compounds were iron hydroxynitrate $Fe_4(OH)_{11}NO_3{\cdot}2H_2O$ but a mall quantity of hematite was also identified in X-ray diffraction(XRD) analysis. The batch isotherms of Fe-GAC for arsenic adsorption were well explained by Langmuir than Freundlich model and the iron contents of Fe-GAC have positive linear correlations on logarithmic plots with Freundlich distribution coefficients ($K_F$ and Langmuir maximum adsorption capacities ($Q_m$. The results of kinetic experiments suggested hat Fe-GAC had he excellent arsenic adsorption capacities regardless of all pH conditions except for pH 11 and could be used a promising adsorbents for groundwater arsenic removal considering the general groundwater pH range of 6-8. The pseudo-second order model, based on the assumption that the ate-limiting step might be chemisorption, provided the best correlation of the kinetic experimental data and explained the arsenic adsorption system f Fe-GAC. The column test was conducted to valuate the feasibility of Fe-GAC use and the operation parameters in arsenic groundwater treatment system. The parameters obtained from the column test were the retardation actor of 482.4 and the distribution coefficient of 581.1 L/mg which were similar values of 511.5-592.5 L/mg acquired from Freundlich batch isotherm model. The results of this study suggested that Fe-GAC could be used as promising adsorbent of arsenic removal in a small groundwater supply system with water treatment facility.

Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study (동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발)

  • Lee Suk;Lee Sang Hoon;Shin Dongho;Yang Dae Sik;Choi Myung Sun;Kim Chul Yong
    • Radiation Oncology Journal
    • /
    • v.22 no.4
    • /
    • pp.316-324
    • /
    • 2004
  • Purpose : In radiotherapy of tumors in liver, enough planning target volume (PTV) margins are necessary to compensate breathing-related movement of tumor volumes. To overcome the problems, this study aims to obtain patients' body movements by using a moving phantom and an ultrasonic sensor, and to develop respiration sating techniques that can adjust patients' beds by using reversed values of the data obtained. Materials and Methods : The phantom made to measure patients' body movements is composed of a microprocessor (BS II, 20 MHz, 8K Byte), a sensor (Ultra-Sonic, range $3\~3$ m), host computer (RS232C) and stepping motor (torque 2.3 Kg) etc., and the program to control and operate it was developed. The program allows the phantom to move within the maximum range of 2 cm, its movements and corrections to take place In order, and x, y and z to move successively. After the moving phantom was adjusted by entering random movement data (three dimensional data form with distance of 2 cm), and the phantom movements were acquired using the ultra sonic sensor, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using guinea pigs, the real-time respiration gating techniques were drawn by operating the phantom with the reversed values of the data. Results : The result of analyzing the acquisition-correction delay time the three types of data values and about each value separately shows that the data values coincided with one another within $1\%$ and that the acquisition-correction delay time was obtained real-time $(2.34{\times}10^{-4}sec)$. Conclusion : This study successfully confirms the clinic application possibility of respiration gating techniques by using a moving phantom and an ultrasonic sensor. With ongoing development of additional analysis system, which can be used in real-time set-up reproducibility analysis, it may be beneficially used in radiotherapy of moving tumors.

Investigation of ground condition charges due to cryogenic conditions in an underground LNG storage plant (지하 LNG 저장 시험장에서 극저온 환경에 의한 지반상태 변화의 규명)

  • Yi Myeong-Jong;Kim Jung-Ho;Park Sam-Gyu;Son Jeong-Sul
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.67-72
    • /
    • 2005
  • To investigate the feasibility of a new concept of storing Liquefied Natural Gas (LNG) in a lined hard rock cavern, and to develop essential technologies for constructing underground LNG storage facilities, a small pilot plant storing liquid nitrogen (LN2) has been constructed at the Korea Institute of Geoscience and Mineral Resources (KIGAM). The LN2 stored in the cavern will subject the host rock around the cavern to very low temperatures, which is expected to cause the development of an ice ring and the change of ground condition around the storage cavern. To investigate and monitor changes in ground conditions at this pilot plant site, geophysical, hydrogeological, and rock mechanical investigations were carried out. In particular, geophysical methods including borehole radar and three-dimensional (3D) resistivity surveys were used to identify and monitor the development of an ice ring, and other possible changes in ground conditions resulting from the very low temperature of LN2 in the storage tank. We acquired 3D resistivity data before and after storing the LN2, and the results were compared. From the 3D images obtained during the three phases of the resistivity monitoring survey, we delineated zones of distinct resistivity changes that are closely related to the storage of LN2. In these results, we observed a decrease in resistivity at the eastern part of the storage cavern. Comparing the hydrogeological data and Joint patterns around the storage cavern, we interpret this change in resistivity to result from changes in the groundwater flow pattern. Freezing of the host rock by the very low temperature of LN2 causes a drastic change in the hydrogeological conditions and groundwater flow patterns in this pilot plant.

Suitability of Migration Testing for Food Packaging Materials Using Tenax® (Tenax®를 이용한 식품포장재의 용출 실험의 적합성)

  • Kim, Hyeong-Jun;Bang, Dae Young;Kim, Min Ho;Lee, Keun Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.24 no.3
    • /
    • pp.97-106
    • /
    • 2018
  • This study aimed at examining the suitability of $Tenax^{(R)}$ for the migration testing of food packaging materials, which is currently approved in the EU as a dry food simulant. The results are used as a basis to examine the feasibility of introducing $Tenax^{(R)}$ to Korean regulation. The OMVs of test specimen into various solvents (diethyl ether, ethanol, pentane, and acetone) after exposure to $100^{\circ}C$ for 1 hr were compared. Diethyl ether showed the highest OMV ($1.33mg/dm^2$) among the solvents tested. When the tests were conducted with different amounts of $Tenax^{(R)}$ of 2, 4, or 8 g per specimen, the OMVs were 0.75, 1.33 and $1.40mg/dm^2$, respectively. The OMV obtained with a closed system after wrapping with aluminum foil showed a significantly higher OMV ($1.61mg/dm^2$) than that without aluminum wrapping ($1.318mg/dm^2w$) and an open system without lid ($1.06mg/dm^2$). The specific migration rates of surrogates spiked in the polyethylene test film and paper samples into $Tenax^{(R)}$ were compared with those into liquid food simulants including 95% ethanol and n-heptane, and actual foods such as starch, skim milk, and sugar. In general, the specific migration levels of surrogates into $Tenax^{(R)}$ were similar compared with n-heptane, however those were significantly higher than into actual foods. These results suggest that $Tenax^{(R)}$ may be used as a food simulant for the long-term preservation of dried foods and paper products. However, more studies need to be conducted to investigate the factors influencing the migration into $Tenax^{(R)}$, such as the types of foods and packaging materials tested, migration conditions, and surrogates properties etc.

A Study on Wintering Microclimate Factors of Evergreen Broad-Leaved Trees, in the Coastal Area of Incheon, Korea (인천해안지역의 난온대성 상록활엽수 겨울철 생장에 영향을 미치는 미기후 요인)

  • Kim, Jung-Chul;Kim, Do-Gyun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.47 no.5
    • /
    • pp.66-77
    • /
    • 2019
  • This study investigated the feasibility of wintering evergreen broad-leaf trees in the Incheon coastal area through a climate analysis. The coldest monthly mean air temperature ranged from $-2.9^{\circ}C{\sim}-1.6^{\circ}C$. The warmth index of the coastal area of Incheon ranged from $98.89^{\circ}C{\cdot}month-109.03^{\circ}C{\cdot}month$, while the minimum air temperature year ranged from $-13.9^{\circ}C{\sim}-3.6^{\circ}C$. This proved that the Incheon coastal area was not suitable for evergreen broad-leaf trees to grow as the warmth index ranges from $101.0^{\circ}C{\cdot}month{\sim}117.0^{\circ}C{\cdot}month$, and the temperature year-round is $-9.2^{\circ}C$ or higher. This suggests the coastal areas of Incheon is not suitable for the growth of evergreen broad-leaf trees, however some evergreen broad-leaf trees lived in some parts of the area. Wind speed reduction and temperature effect simulations were done using Landschaftsanalyse mit GIS program. As a result of the simulations of wind speed reduction and temperature effects affecting the evergreen broad-leaf trees, it was discovered that a coastal wind velocity of 8.6m/sec was alleviated to be 5m/sec~7m/sec when the wind reached the areas where evergreen broad-leaf trees were present. It was also discovered that species that grew in contact with buildings benefited from a temperature increase of $1.1^{\circ}C{\sim}3.4^{\circ}C$ due to the radiant heat released by the building. Simulation results show that the weather factors affecting the winter growth damages of evergreen broad-leaved trees were wind speed reduction and local warming due to buildings. The wind speed reduction by shielding and local warming effects by buildings have enabled the wintering of evergreen broad-leaved trees. Also, evergreen broad-leaved trees growing in the coastal area of Incheon could be judged to be gradually adapting to low temperatures in winter. This study reached the conclusion that the blockage of wind, and the proximity of buildings, are required for successfully wintering evergreen broad-leaf trees in the coastal area of Incheon.