• Title/Summary/Keyword: Zone model

Search Result 2,405, Processing Time 0.034 seconds

Trophic State Index (TSI), Spatial Gradient Characteristics and the Empirical Models for Eutrophication Evaluations in Daecheong Reservoir (대청호 수질오염 평가를 위한 부영양도 지수산정, 공간적 구배 특성 및 경험적 모델)

  • Kwon, Hyuk-Hyun;An, Kwang-Guk
    • Journal of Environmental Science International
    • /
    • v.23 no.9
    • /
    • pp.1537-1549
    • /
    • 2014
  • The objectives of this study were to analyze reservoir trophic state, based on Trophic State Index (TSI), spatial variation patterns of three zones (riverine, transition, and lacustrine zone), and empirical models through 20-years long-term data analysis. Trophic variables of TP and CHL-a were highest during the summer monsoon, and decreased along the main axis from the riverine to lacustrine zone. In the mean time, TN did not show the trend. Ratios of N:P and Secchi disc transparency (SD) increased from the riverine to lacustrine zone. The analysis of trophic state index (TSI) showed that mean TSI (TP) and TSI (CHL-a) were 62 and 57, respectively, and these values were highest in the transition zone during the summer. This zone should be managed well due to highest lake water pollution. The analysis of Trophic State Index Deviation (TSID) showed that algal growth was primarily limited by light penetration, and this was most pronounced in the monsoon season. The analysis of empirical models showed that the value of $R^2$, based on CHL-SD model, was 0.30 (p < 0.0001) in the transition zone and the $R^2$, based on TP-SD model, was 0.41 (p < 0.0001) in the transition zone.

Inherent Damage Zone Model for fatigue Strength Evaluation of Cracks and Notches (영역피해모델에 의한 균열 및 노치의 피로강도평가)

  • Kim Won-Beom;Paik Jeom-Kee;Fujimoto Yukio
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.43 no.4 s.148
    • /
    • pp.494-503
    • /
    • 2006
  • Inherent damage zone model is presented to explain the fatigue properties near the fatigue limit and the crack growth threshold consistently Inherent damage zone model assumes that the stress at a point which is located at a small distance, $r_0$, an inherent length of the material that represents the size of effective damage zone, from the crack initiation position governs the fatigue characteristics regardless of the geometric configuration of the specimen; smooth specimen, notched specimen or cracked specimens with short and long crack length. A special feature of the paper is using the exact stress distributions of notched and cracked specimens at the strength evaluations. Analytical elastic solutions by Neuber and Westergaard are employed for this purpose Relationship between fatigue limit of smooth specimen and threshold stress of cracked specimen, occurrence condition of non-propagating crack at the root of elliptic notch and circular hole and relationship between stress concentration factor and fatigue notch factor are discussed quantitatively based on the proposed model.

Reduced Quasi-Dimensional Combustion Model of the Direct Injection Diesel Engine for Performance and Emissions Predictions

  • Jung, Dohoy;Assanis, Dennis N.
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.865-876
    • /
    • 2004
  • A new concept of reduced quasi-dimensional combustion model for a direct injection diesel engine is developed based on the previously developed quasi-dimensional multi-zone model to improve the computational efficiency. In the reduced model, spray penetration and air entrainment are calculated for a number of zones within the spray while three zones with aggregated spray zone concept are used for the calculation of spray combustion and emission formation processes. It is also assumed that liquid phase fuel appears only near the nozzle exit during the breakup period and that spray vaporization is immediate in order to reduce the computational time. Validation of the reduced model with experimental data demonstrated that the new model can predict engine performance and NO and soot emissions reasonably well compared to the original model. With the new concept of reduced model, computational efficiency is significantly improved as much as 200 times compared to the original model.

A Study on the Application of Fire Modeling for Multiplex Cinema Theater (복합상영관 화재에 대한 화재모델링의 적용)

  • 허준호;김종훈;노삼규;김운형
    • Fire Science and Engineering
    • /
    • v.18 no.1
    • /
    • pp.42-48
    • /
    • 2004
  • The deterministic modeling techniques like Zone model and Field model are mainly used for thermal distribution and smoke flow at fire case in multi use facilities. While Zone model analyse fire simulation by dividing spaces by 2 section, the Field model dividing many cells. However, the difficultly follows to prove efficiency between the two models when it applys. Therefore new modeling development is required which in closes to real situation by verify number algorithm and related data for fire modeling. The paper analyses the efficiency of two different fire modeling at interior spaces of multiplex cinema theater. It is found that the zone model for average distribution and the field model for detail space phenomenon are relevant to apply. Also, Filed model is useful to the result that fire analysis and position of detector and review for smoke control system.

Evaluation of Stress Intensity Factors for an Electrostrictive Crack with an Electric Yielding Zone (전기적 항복영역을 갖는 전왜균열에 대한 응력강도계수 계산)

  • 범현규;정은도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.469-472
    • /
    • 2000
  • a crack with electrically impermeable surfaces in an electrostrictive material subjected to uniform electric loading is analysed. A strip yield zone model is employed to investigate the effect of electric yielding on stress intensity factor. complete forms of electric fields and elastic fields for the crack are derived by using complex function theory. /the stress intensity factors are obtained based on the strip yield zone model.

  • PDF

A Numerical Study of Smoke Movement by Fire In Atrium Space (화재 발생시 연기 거동에 대한 수치해석적 연구 - 아트리움 공간을 중심으로 -)

  • 노재성;유홍선;정연태
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.1
    • /
    • pp.70-76
    • /
    • 1998
  • The smoke filling process for the atrium space containing a fire source is simulated using two types of deterministic fire models : Zone model and Field model. The zone model used is the CFAST(version 1.6) model developed at the Building and Fire Research Laboratories, NIST in the USA. The field model is a self-developed fire field model based on Computational Fluid Dynamics(CFD) theories. This article is focused on finding out the smoke movement and temperature distribution in atrium space which is cubic in shape. A computational procedure for predicting velocity and temperature distribution in fire-induced flow is based on the solution, in finite volume method and non-staggered grid system, of 3-dimensional equations for the conservation of mass, momentum, energy, species and so forth. The fire model i. e. Zone model and Field model predicted similar results for the clear height and the smoke layer temperature.

  • PDF

A Study on Design for Anchorage Zone in PSC Box Girder Bridge Using Strut-Tie Model (스트럿-타이 모델을 이용한 PSC 박스거더교량의 정착부 설계 연구)

  • 이주하;윤영수;이만섭;김병석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.625-630
    • /
    • 2002
  • PSC box girder is widely used in a domestic bridge and overpass, etc., therefore, the design and construction technique for the PSC box girder is developing day by day. Even if it were so, however, the design for anchorage zone in PSC box girder has depended on common sense and empirical results. And it is the current situation that the designer has difficulty due to inadequacy of provisions in the domestic design code and lack of understanding for behavior of anchorage zone. Besides, the design based on Leonhardt's method is being done in general, but the design may be various even for the same structure because of the difference in a way of applying. In this paper, therefore, anchorage zone in PSC box girder bridge is analyzed and designed by using strut-tie model. Adequacy for the application of strut-tie model is verified by comparison with the way used in current design practice, and this study presents that strut-tie model can be a rational and an economical design than current design methods.

  • PDF

Analysis for Fracture Characteristics of Porous Materials by using Cohesive Zone Models (응집영역모델을 이용한 다공질 재료의 파괴 거동 연구)

  • Choi, Seung-Hyun;Ha, Sang-Yul;Kim, Ki-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.6
    • /
    • pp.552-559
    • /
    • 2009
  • The effect of porosity on the crack propagation is studied by using the cohesive zone model. Standard mode I fracture test were done by using compact tension specimens with various porosities. Load-load line displacement curves and ${\delta}_5$-crack resistance curves for various porosities were obtained from experiments. The cohesive zone model proposed by Xu and Needleman was employed to describe the crack propagation in porous media, and the Gurson model is used for constitutive relation of porous materials. These models were implemented into user subroutines of a finite element program ABAQUS. The fracture mode changes from ductile fracture to brittle fracture as the porosity increases. Numerical calculations agree well with experimental results.

A Knowledge Based Physical Activity Evaluation Model Using Associative Classification Mining Approach (연관 분류 마이닝 기법을 활용한 지식기반 신체활동 평가 모델)

  • Son, Chang-Sik;Choi, Rock-Hyun;Kang, Won-Seok
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.13 no.4
    • /
    • pp.215-223
    • /
    • 2018
  • Recently, as interest of wearable devices has increased, commercially available smart wristbands and applications have been used as a tool for personal healthy management. However most previous studies have focused on evaluating the accuracy and reliability of the technical problems of wearable devices, especially step counts, walking distance, and energy consumption measured from the smart wristbands. In this study, we propose a physical activity evaluation model using classification rules, induced from the associative classification mining approach. These rules associated with five physical activities were generated by considering activities and walking times in target heart rate zones such as 'Out-of Zone', 'Fat Burn Zone', 'Cardio Zone', and 'Peak Zone'. In the experiment, we evaluated the prediction power of classification rules and verified its effectiveness by comparing classification accuracies between the proposed model and support vector machine.

Plastic Zone Size in a Ductile Layer with an Interface Crack - Case Study for Dissimilar Substrates - (계면균열을 가진 연성접합재의 소성영역 크기 - 이종 모재의 경우 -)

  • Kim, Dong-Hak;Kang, Ki-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.6
    • /
    • pp.898-904
    • /
    • 2003
  • Using the modified Irwin model and the modified Dugdale model, the plastic zone size near the interface crack tip in a ductile layer bonding two dissimilar elastic substrates is predicted. Validity of the models is examined by finite element method. The effects of several factors such as the mode mixity, T-stress and material properties are explored. The plastic zone size significantly decreases with the Poisson's ratio of the ductile layer.