• Title/Summary/Keyword: Zero energy

Search Result 1,200, Processing Time 0.024 seconds

Fuel cell based CHP technologies for residential sector (연료전지와 마이크로 열병합 발전기술)

  • Son, Young Mok
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.251-258
    • /
    • 2016
  • This article reports current status of micro fuel cell-combined heat and power (${\mu}FC$-CHP) systems which utilize both power and heat generated by fuel cells. There are several options for constructing CHP systems and among them, fuel cells are the most useful and their total energy efficiency combining heat and power can reach up to about 90%. Fuel cells are classified as five types based on the electrolyte, but the most suitable fuel cell types for the ${\mu}FC$-CHP system are proton exchange membrane fuel cells (PEMFCs) and solid oxide fuel cells (SOFCs). ${\mu}FC$-CHP systems have several advantages such as decrease of the transmission-distribution loss, reduced costs of electricity due to distributed power generation, and environmental-friendliness owing to zero emission. The main drawback of the ${\mu}FC$-CHP systems is the high initial investment, however, it keeps decreasing as the technology development reduces production costs. Currently, Japan is the most leading country of the ${\mu}FC$-CHP market, however, Korea tries to expand the market by planning the deployment of 1 million units of ${\mu}FC$-CHP systems and governmental subsidiary supporting of half of the install price. In this report, integration technologies for connecting FC and CHP, and technology trends of leading countries are presented as well.

Effect of Graded Levels of Rice Mill Feed (RMF) Supplementation on Intake, Nutrient Digestibility, Microbial N Yield and Growth Rate of Native (Bos Indicus) Bulls Fed Rice Straw Alone

  • Chowdhury, S.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.10 no.5
    • /
    • pp.445-454
    • /
    • 1997
  • Rice bran commonly available in Bangladesh is a mixture of rice hulls (60%), bran (35%) and polishing (5%), referred here as rice mill feed (RMF). Dose response effect of RMF supplementation to a straw diet including a zero level was measured on the intake, digestibility, nitrogen balance, microbial N yield and growth rate of growing native (Bos indicus) bulls. Twelve bulls of 33 months old and $272{\pm}31.5kg$ weight were randomly allocated to diets having 0 (T1), 1 (T2) and 2 (T3) kg RMF in addition to 200 g wheat bran, 200 g molasses, 60 g salt and 30 g oyestershe\l powder. Concentrate intake was 5.5, 19.2 and 29.5% of the dietary intake for the T1, T2 and T3 treatment respectively. RMF supplementation had no significant effect on the straw DM intake. However, with the increasing levels of RMF supplementation, total DM & digestible OM intake and the whole gut digestibilities of DM, OM, N & ADF increased but in deminishig return. Total microbial N yield estimated from the urinary purine excretion were 15.35, 26.56 and 38.44 g/d for the treatment T1, T2 and T3 respectively. Both the N intake and the N balance increased linearly in response to increasing level of RMF. Supplementation of RMF linearly increased the energy intake and dietary energy concentration. Growth rate in the T1, T2 and T3 treatments were 112, 125 and 250 g/d respctively. The basal N excretion and the maintenance energy requirement of the experimental animals were estimated to be 615 mg/kg $W^{0.75}/d$ and 447 kJ/kg $W^{0.75}/d$ respectively. The estimated efficiency on N utilization was 0.83 mg/mg of N intake ($r^2=0.997$) while the efficiency of metabolizable energy utilization for growth was 0.15. Since animal refused higher levels of RMF, inclusion up to 2 kg level (about 25% of the total DM intake) appears to have no depressing effect on the performances of animal. However, RMF itself fail to meet the critical nutrient need of the rumen microbes. Therefore response of supplementing RMF after correcting the critical nutrient deficiency need to be studied.

The Benefit-Cost analysis for Korea Lithium-ion Battery Waste Recycling project and promotion plans (국내 중대형 이차전지 재활용 사업의 경제성 분석 및 발전방안 연구)

  • Mo, Jung-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.326-332
    • /
    • 2018
  • Korea faces major changes in energy policy, which include eco-friendly and zero-nuclear power. On the other hand, there are very few policies for the waste-management of mid- to large-sized lithium-ion batteries, such as electric car batteries and energy storage systems, which are expected to increase explosively due to such energy policy changes. Therefore, this study estimated the amount of mid- to large-sized lithium ion batteries waste and performed economics analysis of a middle and large sized secondary battery recycling project. Based on the results, a policy alternative for the revitalization of the related lithium-ion battery recycling industry is suggested. As a result, the B / C ratio of a domestic mid - to large - sized lithium ion battery recycling project is 1.06, in which the benefit is higher than the cost, so the business is economic feasible. Although the recycling project's economic efficiency is high, the recycling industry has not been activated in Korea because the domestic demand for rechargeable batteries recycling is very low. To solve this problem, this study proposes a plan to activate the industry by adding lithium secondary batteries to the EPR (Extended Producer Responsibility) items.

A Study for Recoverability of Iron Resource in Red Mud (레드머드 내 철 자원 회수 가능성 고찰)

  • Kim, Bong-Ju;Kwon, Jang-Soon;Koh, Yong-Kwon;Park, Cheon-Young
    • Economic and Environmental Geology
    • /
    • v.53 no.3
    • /
    • pp.297-306
    • /
    • 2020
  • The red mud generated from bauxite during the Bayer alumina production process has been regarded as an industrial waste due to the high alkaline property and high content of Na. Despite of its environmental problem, various studies for recovery of the valuable resources from red mud has been also carried out because of high content (25.7 wt.% as Fe2O3 in this study) of iron in red mud. In order to recover the iron resource in the red mud, microwave heating experiments were performed with adding of activated carbon and elemental sulfur to the red mud. Through the microwave heating the powdered red mud mixtures converted to porous and vitrified solid aggregates. The vitrified aggregates produced by microwave heating are composed of goethite, zero valent iron (Fe0), pyrrhotite and pyrite. And then, the microwave heating samples were dissolved in the aqua regia solution, and Fe precipitates were obtained as a Fe-chlorides by adding of NaCl salt in the aqua regia solution. The Fe recovery rates in the Fe-chloride precipitates showed differences depending on the experimental mixture conditions, and Fe grades of the end products are 49.0 wt.%, 58.0 wt.% and 59.5 wt.% under mixture conditions of red mud, red mud + activated carbon, and red mud + activated carbon + elemental S, respectively. The Fe content of 56.0 wt.% is generally known as the grade value of Fe in a iron ore for iron production, and the Fe grades of microwave heating samples with adding activated carbon and elemental S in this study are higher than the grade value of 56.0 wt.%.

Solar Energy Storage Effectiveness on Double Layered Single Span Plastic Greenhouse (2중 단동비닐하우스의 태양열 축열이용 효과)

  • Lee, Sung-Hyoun;Ryou, Young-Sun;Moon, Jong-Pil;Yun, Nam-Kyu;Kwon, Jin-Kyung;Lee, Su-Jang;Kim, Kyeong-Won
    • Journal of Biosystems Engineering
    • /
    • v.36 no.3
    • /
    • pp.217-222
    • /
    • 2011
  • This study was carried out in order to reduce the amount of underground water which is used in the double layered single span plastic greenhouse for retaining heat. For this research, two plastic green houses of the double layered single span plastic greenhouse were installed. There was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50 cm in diameter filled with subsurface water. The surplus solar energy in the greenhouse was stored in the water in the PVC duct. Four FCUs (Fan Coil Unit), which has the capacity of 8,000 kcal per hour, were installed in the middle of the house, and a circulation motor in heat storage water tank was operated from 10:30 a.m. to 16:00 p.m. in order to circulate water between the water tank and the FCUs. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of lower than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. To prevent the water freezing, mixing antifreezing liquid in the water or operating FCU continuously was needed. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Considering the amount of water used in the house with water-curtain-heating system is 150~200 ton per day, using the system mentioned in this research showed that reducing the underground water more than 80% in order to maintain the internal temperature as the level of 5 degree celsius at the extreme temperature of minus 5 degrees celsius.

Adaptive Discrete Wavelet Transform Based on Block Energy for JPEG2000 Still Images (JPEG2000 정지영상을 위한 블록 에너지 기반 적응적 이산 웨이블릿 변환)

  • Kim, Dae-Won
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.1
    • /
    • pp.22-31
    • /
    • 2007
  • The proposed algorithm in this paper is based on the wavelet decomposition and the energy computation of composed blocks so the amount of calculation and complexity is minimized by adaptively replacing the DWT coefficients and managing the resources effectively. We are now living in the world of a lot. of multimedia applications for many digital electric appliances and mobile devices. Among so many multimedia applications, the digital image compression is very important technology for digital cameras to store and transmit digital images to other sites and JPEG2000 is one of the cutting edge technology to compress still images efficiently. The digital cm technology is mainly using the digital image compression features so that those images could be efficiently saved locally and transferred to other sites without any losses. JPEG2000 standard is applicable for processing the digital images usefully to keep, send and receive through wired and/or wireless networks. The discrete wavelet transform (DWT) is one of the main differences to the previous digital image compression standard such as JPEG, performing the DWT to the entire image rather than splitting into many blocks. Several digital images m tested with this method and restored to compare to the results of conventional DWT which shows that the proposed algorithm get the better result without any significant degradation in terms of MSE & PSNR and the number of zero coefficients when the energy based adaptive DWT is applied.

  • PDF

Theoretical Study on the Hydrogen-Bonding Effect of H2On-H2Om (n=1-4, m=1-4) Dimers (H2On-H2Om (n=1-4, m=1-4) 이중합체의 수소결합에 따른 구조적 특성 및 결합에너지에 관한 이론 연구)

  • Song, Hui-Seong;Seo, Hyun-Il;Shin, Chang-Ho;Kim, Seung-Joon
    • Journal of the Korean Chemical Society
    • /
    • v.59 no.2
    • /
    • pp.117-124
    • /
    • 2015
  • The DFT and ab initio calculations have been performed to elucidate hydrogen interaction of hydrogen polyoxide dimers, $H_2O_n-H_2O_m$ (n=1-4, m=1-4). The optimized geometries, harmonic vibrational frequencies, and binding energies are predicted at various levels of theory. The harmonic vibrational frequencies of the molecules considered in this study show all real numbers implying true minima. The higher-order correlation effect were discussed to compare MP2 result with CCSD(T) single point energy. The binding energies were corrected for the zero-point vibrational energy (ZPVE) and basis set superposition errors (BSSE). The largest binding energy predicted at the CCSD(T)/cc-pVTZ level of theory is 8.18 kcal/mol for $H_2O_4-H_2O_3$ and the binding energy of water dimer is predicted to be 3.00 kcal/mol.

Economic Feasibility Analysis of Marine Ecosystem Restoration Technology Program (해양생태계 복원기술개발 사업의 경제적 타당성 분석)

  • Kwon, Young-Ju;Paik, Sang-Kyu;Yoo, Seung-Hoon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.2
    • /
    • pp.130-142
    • /
    • 2014
  • The Korean government is considering implementation of the marine ecosystem restoration technology program (MERTP) to analyze the current status of the marine ecosystems and causes for the ecosystem deterioration as well as to eventually establish a master strategic plan for restoring ecosystem functions and preventing ecosystem functional loss. In order to determine likelihood of successful implementation, it is essential to perform an analysis of the economic feasibility of the program. The present study assessed economic feasibility of the MERTP. To this end, the dichotomous choice contingent valuation (CV) method is used. In particular, dichotomous choice (DC) format is employed as a method of eliciting willingness-to-pay (WTP) response to incentive-compatible mechanisms. The study also employed the spike model to deal with zero WTP responses from the DC CV survey. This survey of 1,000 randomly selected households in accordance with the guidelines provided by the National Oceanic and Atmospheric Administration (USA) was carried out nationwide in 2013. And, the respondents were asked in person-to-person interviews about their WTP for implementing the MERTP. The results showed that the annual mean WTP was estimated to be 5,414 won per household. Consequently, the annual benefit from the MERTP would be about 98.6 billion won for the next five years. Economic feasibility assessment utilizing the MERTP investment cost and expansion cost of the value provided that net present value, benefit/cost ratio, and internal rate of return are 337.8 billion won, 5.20, and 65.9 %, respectively, which are bigger than 0, 1.0, and 5.5 %, and that the MERTP passes the cost-benefit analysis.

Metabolizable Energy Contents and Amino Acid Availability values in the Full-Fat Seeds, Oil Meals and Oils of Canola (Canola전지종실과 유박 및 기름의 대사에너지 함량과 아미노산 이용률)

  • 이규호;심정석
    • Korean Journal of Poultry Science
    • /
    • v.17 no.2
    • /
    • pp.101-107
    • /
    • 1990
  • Apparent and true metabolizable energy (AME and TME) contents and true amino acid availability (TAAA) values of full-fat seed, oil meal and oil of canola were assayed employing mature Single Comb white Leghorn roosters. For AME, test diets containing 30% level of canola full-fat seed, oil meal, oil meal plus oil or 10% level of oil were fed for a 3-day adaptation period, followed by a 4-day fecal collection period. For TME and TAAA, 30g test diets were force-fed and total excreta were collected for 48 hours, following a 24 hour fasting period. Metabolizable energy values were corrected to zero nitrogen balance(AMEn and TMEn), Canola contained 4,485, 1,984,8,275 and 5,655kcal/kg of AMEn and 4,577, 2,103, 8,487 and 5,630kcal/kg of TMEn for full-fat seed, oil meal, oil and mixture of meal plus oil, respectirely. The mixtures of oil meal plus oil had significantly higher available energy contents than the full-fat seeds (p<0.01) . In general, TAAA values of full-fat seed were higher than those of oil meal.

  • PDF

Demand Shifting or Ancillary Service?: Optimal Allocation of Storage Resource to Maximize the Efficiency of Power Supply (Demand Shifting or Ancillary Service?: 효율적 재생발전 수용을 위한 에너지저장장치 최적 자원 분배 연구)

  • Wooyoung Jeon
    • Environmental and Resource Economics Review
    • /
    • v.33 no.2
    • /
    • pp.113-133
    • /
    • 2024
  • Variable renewable energy (VRE) such as solar and wind power is the main sources of achieving carbon net zero, but it undermines the stability of power supply due to high variability and uncertainty. Energy storage system (ESS) can not only reduce the curtailment of VRE by load shifting but also contribute to stable power system operation by providing ancillary services. This study analyzes how the allocation of ESS resources between load shifting and ancillary service can contribute to maximizing the efficiency of power supply in a situation where the problems caused by VRE are becoming more and more serious. A stochastic power system optimization model that can realistically simulate the variability and uncertainty of VRE was applied. The analysis time point was set to 2023 and 2036, and the optimal resource allocation strategy and benefits of ESS by varying VRE penetration levels were analyzed. The analysis results can be largely summarized into the following three. First, ESS provides excellent functions for both load shifting and ancillary service, and it was confirmed that the higher the reserve price, the more limited the load shifting and focused on providing reserve. Second, the curtailment of VRE can be a effective substitute for the required reserve, and the higher the reserve price level, the higher the curtailment of VRE and the lower the required amount of reserve. Third, if a reasonable reserve offer price reflecting the opportunity cost is applied, ESS can secure economic feasibility in the near future, and the higher the proportion of VRE, the greater the economic feasibility of ESS. This study suggests that cost-effective low-carbon transition in the power system is possible when the price signal is correctly designed so that power supply resources can be efficiently utilized.