• 제목/요약/키워드: Z.-M. 방법

검색결과 297건 처리시간 0.028초

Production of Carpet Sod Using Seed and Runner of Zoysiagrass (Zoysia spp.) (한국잔디(Zoysia spp.)의 종자 및 영양체를 이용한 carpet 잔디 생산)

  • 최준수;양근모;김동섭
    • Asian Journal of Turfgrass Science
    • /
    • 제15권2호
    • /
    • pp.39-50
    • /
    • 2001
  • This research was designed to develop the rapid propagation technology of zoysiagrass using carpet production and to provide turf-growing farmers with efficient cultivation methods thor carpet production. Turfgrass cultivar tested in cadet production by seeding was Z. japonica cv. Zenith. Since the surface coverage rate reached to 85% in 2 months after seeding at the rate 6g/$m^2$ in the early part of July, carpet production using ‘Zenith’seeds would be possible to produce within within the same year. Thrfgrasses tested in carpet production by vegetative propagation were Z. japonica, medium type Z. matrella, fine type Z. matrella, and medium type Z. japonica. Planting rates of vegetative parts (sprigs) were 1.2L/$m^2$, 2.4L/$m^2$, 2.5L/$m^2$, and 5L/$m^2$. Two different sizes of sprig were used; 1~2 nodes and 3~4 nodes. Surface coverage rate was 90% in one year after planting at the rate of 2.5L sprigs of medium type Z. japonica. Therefore, the use of sprigs with 3~4 nodes at the planting rate of 2.5L would be suitable for the carpet prodcution. Three months old zoysiagrass carpet (Zenith) was overseeded with Kentucky bluegrass, perennial ryegrass, and tall fescue at two different overseeding rate. Surface coverage rate was the highest (80%) at the plot overseeded with perennial ryegrass that showed the earliest germination. Suitable overseeding species for the rapid sod formation at the early stage of establishment were tall fescue and perennial ryegrass and desirable overseeding time was from early to middle of September.

  • PDF

Measurement of Thermal Diffusivity and the Optical Properties of a Carbon Nanotube Dispersion by Using the Thermal Lens Effect (열렌즈 효과를 이용한 탄소 나노 튜브 분산액의 열확산도와 광학적 특성 측정)

  • Park, Hyunwoo;Kim, Hyunki;Kim, Sok Won;Lee, Joohyun
    • New Physics: Sae Mulli
    • /
    • 제68권11호
    • /
    • pp.1167-1172
    • /
    • 2018
  • Carbon nanotubes (CNTs) are structures of carbon atoms bonded together in hexagonal honeycomb shapes, with multi-walled CNTs having a very high thermal conductivity of $3000W/m{\cdot}K$ and single-walled CNTs having a conductivity of $6000W/m{\cdot}K$. In this work, the transmittance and the thermal diffusivity of a multi-walled carbon nanotube dispersion with a concentration of 1.5 M were measured using a single beam method, a dual beam method, and the thermal lens effect. The nonlinear optical coefficients were obtained by using the z-scan method, which moved the sample in the direction of propagation of the single laser beam, propagation and the thermal diffusivity was measured using a double laser beam. As a pump beam, a diode-pumped solid state (DPSS) laser with a wavelength of 532 nm and an intensity of 100 mW was used. As the probe beam, a He-Ne laser having a wavelength of 633 nm and an intensity of 5 mW was used. The experimental result shows that when the concentrations of the sample were 9.99, 11.10, 16.65, and 19.98 mM, the nonlinear absorption coefficients were 0.046, 0.051, 0.136 and 0.169 m/W, respectively. Also, the nonlinear refractive indices were 0.20, 0.51, 1.25 and $1.32{\times}10^{-11}m^2/W$, respectively, and the average thermal diffusivity was $1.33{\times}10^{-6}m^2/s$.

Determination of Arsenic in Water by ICP-DRC/MS (ICP-DRC/MS를 이용한 수중의 비소 측정)

  • Jeong, Gwan-Jo;Kim, Dok-Chan;Park, Hyeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제28권6호
    • /
    • pp.620-625
    • /
    • 2006
  • In this investigation, an ICP-DRC/MS method to measure arsenic with ultra-trace concentration without any interference by the compounds such as $^{40}Ar^{35}Cl^+\;and\;^{40}Ca^{35}Cl^+$, which disturb the precise measurement of arsonic was described. Thus, the oxgen was introduced into the dynamic reaction cell as reaction gas and reacted with arsenic ion created in plasma gas, $AsO^+$ was formed and detected with m/z of 91 by ICP-MS. It resulted in better detection limit than the old method with m/z of 75($As^+$). The optimum condition for oxygen supply as the reaction gas was 0.5 mL/min. The analytical features of the method are as follows: detection limit of $0.02{\mu}g/L$, precision(RSD) of 3.4%, and recovery of 96%. Arsenic in the water samples from the tributary streams to the Han River and the main stream of Paldang were analyzed with this method to identify the characteristics in its distribution. The concentration of As ranged from 0.53 to $1.26{\mu}g/L$. We could measure As with very low concentration, less than $1.0{\mu}g/L$, with excellent reproducibility. The method developed is expected to be applied to analyze As of the samples from sea water, food, and domestic and industrial waste water which have high concentration of Cl and/or Ca.

Isolation and Purification of Decursin and Decursinol Angelate in Angelica gigas Nakai (참당귀(Angelica gigas Nakai) 중 Decursin 및 Decursinol Angelate의 분리 및 정제)

  • Kim, Kang-Min;Jung, Jae-Yeon;Hwang, Sung-Woo;Kim, Myo-Jeong;Kang, Jae-Seon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • 제38권5호
    • /
    • pp.653-656
    • /
    • 2009
  • This paper is intended as an investigation of the method of extraction and the analysis by high-performance liquid chromatography mass spectroscopy of decursin and decursinol angelate in the dried root of Angelica gigas Nakai. The extracted decursin and decursinol angelate were the purity of >95% using 60% ethanol at $-20^{\circ}C$ for 12 hours by HPLC analysis. Decursin and decursinol angelate were efficiently isolated using recycling HPLC. The purity of isolated decursin and decursinol angelate was identified as 99.97 and 99.40% by HPLC analysis, respectively. The molecular weights of Decursin and decursinol angelate were also identified as m/z=329 ($[M+H]^+$) and m/z=351 ($[M+Na]^+$) by mass spectroscopy.

Assessment of Early Dental Caries by Using Optical Coherence Tomography (Optical Coherence Tomography를 이용한 초기 치아우식 검사)

  • Min, Ji-Hyun
    • Journal of dental hygiene science
    • /
    • 제16권4호
    • /
    • pp.257-262
    • /
    • 2016
  • The purpose of this study was to assess the correlation between integrated mineral loss (volume % mineral${\times}{\mu}m$, ${\Delta}Z_{TMR}$) determined using transverse microradiography (TMR) and integrated reflectivity ($dB{\times}{\mu}m$, ${\Delta}R_{OCT}$) determined using optical coherence tomography (OCT) for detecting early dental caries with lesion depth more than $200{\mu}m$. Sixty tooth specimens were made from sound bovine teeth. They were immersed in a demineralized solution for 20, 30, and 40 days. The ${\Delta}R_{OCT}$ was obtained from the cross-sectional OCT image. The ${\Delta}Z_{TMR}$ was obtained from the TMR image. The correlation between ${\Delta}R_{OCT}$ and ${\Delta}Z_{TMR}$ was examined using Pearson correlation. The Bland-Altman plot was constructed using the ${\Delta}R_{OCT}$ and ${\Delta}Z_{TMR}$ values. A significant correlation between ${\Delta}R_{OCT}$ and ${\Delta}Z_{TMR}$ was confirmed (r=0.491, p=0.003). Moreover, most of the difference between ${\Delta}R_{OCT}$ and ${\Delta}Z_{TMR}$ was included in the error section of the Bland-Altman plot. Therefore, OCT could be used as a substitute for TMR when analyzing mineral loss in early dental caries.

Process of Digital Elevation Model Using RC Helicopter Surveying System (무선조정 헬리콥터 사진측량시스템을 이용한 수치표고모형 작성)

  • Jang, Ho-Sik
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • 제26권2호
    • /
    • pp.111-116
    • /
    • 2008
  • The study installed non metric camera which was a 10 Mega Pixel camera in RC Helicopter. And the study controlled images hotographed in air on land, considering their overlap. The study could express DEM by abstracting TIN from the acquired images through image registration. Also, the study compared and examined accuracy between reference point and check point observed by Total Station which was a conventional type of survey. As the results, the study could get errors of $-0.194{\sim}0.224\;m$ on X axis, $-0.088{\sim}0.180\;m$ on Y axis and $-0.286{\sim}0.285\;m$ on Z axis. Expressing an error's RMSE in the checkpoint, the study could get of 0.021388 m on X axis, 0.015285 m on Y axis and 0.041872 m on Z axis. It is judged that the above photographing and analyzing technique are better than the existing Total Station to acquire more terrain elevation data.

Synthesis and Isolation of Monoacetyl-DCB and Diacetyl-DCB from 3,3대-dichlorobenzidine(DCB) (디클로로벤지딘으로부터 대사물질의 합성과 분리방법에 대한 연구)

  • Lee, Jin-Heon;Lee, Beom-Gyu
    • Journal of Environmental Health Sciences
    • /
    • 제29권2호
    • /
    • pp.50-55
    • /
    • 2003
  • 3,3-dichlorobenzidine is suspected to be cancinogenic in experimental animal and human. Several studies have investigated excretion of metabolites in urine, hemoglobin adduction and cancer incidence among workers occupationally exposed to 3,3'-dichlorobenzidine. In these researches, metabolites of 3,3'-dichlorobenzidine had a very important role, and were required as highly purity. The purpose of this study was synthesis and isolation of its metabolites from 3,3'-dichlorobenzidine. 3,3'-dichlorobenzidine was partially dissolved in benzene, ether, ethanol and methanol, and completely dissolved in 70% acetic acid on mixtures of citric acid containing less than 1% DCB, pyridine, a mixture of 0.5N NaOH and toluene(1:2), and phenol saturated with 20 mM TRIZA base. DCB, monoacetyl-DCB and diacetyl-DCB were measured by using gas chromatography/mass spectrometry(GC/MS). Detection for checking them was nitrogen phosphorous detection mode(NPD), and for identifying them was selected ion monitoring mode(SIM). The base peaks were 252 m/z in DCB, 252, and 294 m/z in monoacetyl-DCB, and 252, 294 and 336 m/z in diacetyl-DCB, respectively. Diacetyl-DCB was synthesized by titrating DCB solution of pyridine with sufficient acetyl chloride. Precipitation was diacetyl-DCB, which was purity of 98.7%. And its supernatant was composed of DCB, monoacetyl-DCB and diacetyl-DCB. By using acetic acid as controller of acetylation, monoacetyl-DCB was isolated from diacetyl-DCB . And residual pyridine was removed by using acetone. The purity of monoacetyl-DCB was 98.8%.

The Enhanced Off-Diagonal Magneto-Impedance Effect in Cu/Ni80Fe20 Core-Shell Composite Wires Fabricated by Electrodeposition under Torsional Strain (비틀림 스트레인 하에서 전기도금으로 만든 Cu 코어/Ni80Fe20 쉘 복합 와이어에서 비대각 자기임피던스(Off-diagonal Magneto-Impedance) 효과의 증대)

  • Kim, Dong Young;Yoon, Seok Soo;Lee, Sang Hun
    • Journal of the Korean Magnetics Society
    • /
    • 제27권4호
    • /
    • pp.135-139
    • /
    • 2017
  • The magneto-impedance effect (MI effect) has been investigated in metal core/soft magnetic shell composite wires fabricated by electrodeposition of $Ni_{80}Fe_{20}$ on Cu wire (diameter $190{\mu}m$). The diagonal impedances $Z_{zz}$ and $Z_{{\theta}{\theta}}$ in cylindrical coordinate showed strong MI effect for the magnetic field applied along z-axis, while the off-diagonal impedance $Z_{{\theta}z}$ showed very weak MI effect. We have tried to develop the Cu $core/Ni_{80}Fe_{20}$ shell composite wire having strong MI effect in off-diagonal impedance by electrodeposion under torsional strain. The core/shell composite wire electrodeposited under torsional angles above $270^{\circ}$ showed significantly enhanced MI effect in the off-diagonal impedance. The maximum MI effect was observed in the composite wire electrodeposited under torsional angle of $360^{\circ}$. The developed method to enhance off-diagonal MI effect is expected to increase the applicability of the core/shell composite wire to magnetic sensor material.

The Crystallograpic and Magnetic Properties of EuFeO3 Doped with in ions (In 이온을 첨가한 $EuFeO_{3}$의 결정구조 및 자기적 성질)

  • 김정기;서정철;한은주
    • Journal of the Korean Magnetics Society
    • /
    • 제4권4호
    • /
    • pp.335-339
    • /
    • 1994
  • The crystallograpic and magnetic properties of $Eu(Fe_{1-x}In_{x})O_{3}$ (x=0, 0.03과 0.05) have been studied by the methods of X-ray diffraction, $M\"{o}ssbauer$ spectroscopy, and magnetic hysteresis measurement at room temperature. The X-ray results show that the samples have a crystal structure of orthorhombic and unit cell volume of the crystal with the exception of the sample of x=0 increases as increasing the In concentration. In the analysis assuming two sets of six-line of $M\"{o}ssbauer$ spectra, it is found that the magnetic hyperfine field in each of sets decreases increasing x. The linewidth of the absorption lines for the samples increased as increasing x. This implies that the data involve a sum of several hyperfine patterns which have intensity being proportional to $_{n}P_{z}(x)$, the probability of an environment with z such Fe neighbors. The magnetic hysteresis curves show decrease of $M_{s}$ and increase of $H_{c}$ of the samples with increasing x.

  • PDF

Comparison Radiation Dose of Z-Axis Automatic Tube Current Modulation Technique with Fixed Tube Current Multi-Detector Row CT Scanning of Lower Extremity Venography (하지 정맥조영술 MDCT에서 고정 관전류 기법과 Z-축 자동 관전류 변동 제어에 의한 선량 비교)

  • Yoo, Beong-Gyu;Lee, Jong-Seok;Jang, Keun-Jo;Jeon, Sang-Hwan;Kim, Yong-Soo;Kweon, Dae-Cheol
    • Journal of Radiation Protection and Research
    • /
    • 제32권3호
    • /
    • pp.123-133
    • /
    • 2007
  • Z-axis automatic tube current modulation technique automatically adjusts tube current based on size of body region scanned. The purpose of the current study was to compare noise, and radiation dose of multi-detector row CT (MDCT) of lower extremity performed with Z-axis modulation technique of automatic tube current modulation with manual selection fixed tube current. Fifty consecutive underwent MDCT venography of lower extremity with use of a MDCT scanner fixed tube current and Z-axis automatic tube current modulation technique (10, 11 and 12 HU noise index, $70{\sim}450\;mA$). Scanning parameters included 120 kVp, 0.5 second gantry rotation time, 1.35:1 beam pitch, and 1 mm reconstructed section thickness. For each subject, images obtained with Z-axis modulation were compared with previous images obtained with fixed tube current (200, 250, 300 mA) and with other parameters identical. Images were compared for noise at five levels: iliac, femoral, popliteal, tibial, and peroneal vein of lower extremity. Tube current and gantry rotation time used for acquisitions at these levels were recorded. All CT examinations of study and control groups were diagnostically acceptable, though objective noise was significantly more with Z-axis automatic tube current modulation. Compared with fixed tube current, 2-axis modulation resulted in reduction of CTDIvol (range, $-6.5%{\sim}-35.6%$) and DLP (range, $-0.2%{\sim}-20.2%$). Compared with manually selected fixed tube current, 2-axis automatic tube current modulation resulted in reduced radiation dose at MDCT of lower extremity venography.