• 제목/요약/키워드: Yi Sun-Shin

검색결과 114건 처리시간 0.029초

Ordinary kriging approach to predicting long-term particulate matter concentrations in seven major Korean cities

  • Kim, Sun-Young;Yi, Seon-Ju;Eum, Young Seob;Choi, Hae-Jin;Shin, Hyesop;Ryou, Hyoung Gon;Kim, Ho
    • Environmental Analysis Health and Toxicology
    • /
    • 제29권
    • /
    • pp.12.1-12.8
    • /
    • 2014
  • Objectives Cohort studies of associations between air pollution and health have used exposure prediction approaches to estimate individual-level concentrations. A common prediction method used in Korean cohort studies is ordinary kriging. In this study, performance of ordinary kriging models for long-term particulate matter less than or equal to $10{\mu}m$ in diameter ($PM_{10}$) concentrations in seven major Korean cities was investigated with a focus on spatial prediction ability. Methods We obtained hourly $PM_{10}$ data for 2010 at 226 urban-ambient monitoring sites in South Korea and computed annual average $PM_{10}$ concentrations at each site. Given the annual averages, we developed ordinary kriging prediction models for each of the seven major cities and for the entire country by using an exponential covariance reference model and a maximum likelihood estimation method. For model evaluation, cross-validation was performed and mean square error and R-squared ($R^2$) statistics were computed. Results Mean annual average $PM_{10}$ concentrations in the seven major cities ranged between 45.5 and $66.0{\mu}g/m^3$ (standard deviation=2.40 and $9.51{\mu}g/m^3$, respectively). Cross-validated $R^2$ values in Seoul and Busan were 0.31 and 0.23, respectively, whereas the other five cities had $R^2$ values of zero. The national model produced a higher cross-validated $R^2$ (0.36) than those for the city-specific models. Conclusions In general, the ordinary kriging models performed poorly for the seven major cities and the entire country of South Korea, but the model performance was better in the national model. To improve model performance, future studies should examine different prediction approaches that incorporate $PM_{10}$ source characteristics.

Analytical Methods of Levoglucosan, a Tracer for Cellulose in Biomass Burning, by Four Different Techniques

  • Bae, Min-Suk;Lee, Ji-Yi;Kim, Yong-Pyo;Oak, Min-Ho;Shin, Ju-Seon;Lee, Kwang-Yul;Lee, Hyun-Hee;Lee, Sun-Young;Kim, Young-Joon
    • Asian Journal of Atmospheric Environment
    • /
    • 제6권1호
    • /
    • pp.53-66
    • /
    • 2012
  • A comparison of analytical approaches for Levoglucosan ($C_6H_{10}O_5$, commonly formed from the pyrolysis of carbohydrates such as cellulose) and used for a molecular marker in biomass burning is made between the four different analytical systems. 1) Spectrothermography technique as the evaluation of thermograms of carbon using Elemental Carbon & Organic Carbon Analyzer, 2) mass spectrometry technique using Gas Chromatography/mass spectrometer (GC/MS), 3) Aerosol Mass Spectrometer (AMS) for the identification of the particle size distribution and chemical composition, and 4) two dimensional Gas Chromatography with Time of Flight mass spectrometry (GC${\times}$GC-TOFMS) for defining the signature of Levoglucosan in terms of chemical analytical process. First, a Spectrothermography, which is defined as the graphical representation of the carbon, can be measured as a function of temperature during the thermal separation process and spectrothermographic analysis. GC/MS can detect mass fragment ions of Levoglucosan characterized by its base peak at m/z 60, 73 in mass fragment-grams by methylation and m/z 217, 204 by trimethylsilylderivatives (TMS-derivatives). AMS can be used to analyze the base peak at m/z 60.021, 73.029 in mass fragment-grams with a multiple-peak Gaussian curve fit algorithm. In the analysis of TMS derivatives by GC${\times}$GC-TOFMS, it can detect m/z 73 as the base ion for the identification of Levoglucosan. It can also observe m/z 217 and 204 with existence of m/z 333. Although the ratios of m/z 217 and m/z 204 to the base ion (m/z 73) in the mass spectrum of GC${\times}$GC-TOFMS lower than those of GC/MS, Levoglucosan can be separated and characterized from D (-) +Ribose in the mixture of sugar compounds. At last, the environmental significance of Levoglucosan will be discussed with respect to the health effect to offer important opportunities for clinical and potential epidemiological research for reducing incidence of cardiovascular and respiratory diseases.

심우주 지구 반사율 측정용 아몬라 가시광 채널의 광학 시스템 제조 및 성능 평가 (OPTICAL PERFORMANCE OF BREADBOARD AMON-RA IMAGING CHANNEL INSTRUMENT FOR DEEP SPACE ALBEDO MEASUREMENT)

  • 박원현;김성희;이한신;이현수;이재민;함선정;윤지연;김석환;양호순;최기혁;김진철
    • Journal of Astronomy and Space Sciences
    • /
    • 제24권1호
    • /
    • pp.79-90
    • /
    • 2007
  • 지구와 태양 사이의 중력 평형점에서 혜일로 궤도로 운용되며, 심우주 반사율(albedo)을 측정코자 하는 EARTHSHINE 미션의 과학적 목적에 최적화된 아몬라 가시광 채널의 성능 인증 모델용 광학 시스템 개발을 완료하였다. 아몬라 광학계 설계 요구사항에 부합하는 설계안과 공차분석 결과를 바탕으로 광학 시스템의 설계, 부품 제작, 결합, 정렬, 성능 검증까지의 전 공정을 순수 국내 개발하였으며 특히 측정된 부품들의 광파면 오차를 결합 및 성능 평가 공정에 역투입하는 신 공법에 의하여 성능 검증을 실시하였다. 최종 결합 및 정렬이 완료되어 측정한 아몬라 광학계의 광파면 오차는 중심 시야에서 RMS 0.091 wave(기준 파장: 632.8nin)이며, Ensquared Energy(EE) 성능은 61.7%($14{\mu}m$ 이내), 변조전달함수(MTF) 성능은 35.3%(기준 주파수: $35.7mm^{-1}$)이다. 위 결과들은 아몬라 가시광 채널의 요구사항을 모두 만족시킴으로써 개발된 아몬라 가시광 채널 광학계가 EARTHSHINE 미션의 과학목적을 완수할 수 있음을 증명하였다.

공연예술산업의 유통부문 지원 개선방안 (A Study on Improvement Plans of Public Support for Performing Arts Industry's Distribution)

  • 김선영;이의신
    • 한국산학기술학회논문지
    • /
    • 제18권11호
    • /
    • pp.176-186
    • /
    • 2017
  • 본 연구는 지원에 상당부분 의지하여야 하며 경제적으로 어려운 환경에 처해 있는 공연예술산업의 문제점들을 타개할 방안 또는 개선점을 찾고자 하는 목적으로 시작되었다. 그 과정에서 창제작-유통-소비 등으로 이루어진 공연예술산업의 가치사슬 중 유통부문이 상대적으로 소외되었음을 인식하고 유통 부문 발전 및 개선점을 찾기 위한 방안을 모색코자 하였다. 특히 정부 지원 중 공연 유통의 메인 플랫폼이라고 할 수 있는 공연장 중심의 지원 정책을 살펴봄으로써 유통 부문에 대한 정책적 지원의 개선점을 도출하였다. 이를 위해 공연예술산업과 동 산업의 가치사슬을 이론적으로 살펴보고, 공연예술산업 유통의 구조와 주체, 현황을 분석한 이후, 정부 등 공공의 유통부문 지원 규모와 지원 사업 현황을 분석하였다. 연구결과 건전한 공연예술 생태계가 되기 위해서는 가치사슬을 구성하는 각 주체의 균형 발전과 공진화가 필요하고, 2014년 기준 2.7%에 불과한 정부 및 공공의 유통 매개분야에 대한 지원이 확대되어야 함을 논하였다. 또한 기획사와 같은 유통 주체의 양성과 전문성 향상이 제고되어야 한다. 더불어 공연 영상 등 공연장 이외의 플랫폼 확대를 비롯한 유통의 다각화를 지원하는 방안 등을 제시하였다.

얼굴과 입 모양 인식을 이용한 지능형 휠체어 시스템 (Intelligent Wheelchair System using Face and Mouth Recognition)

  • 주진선;신윤희;김은이
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제36권2호
    • /
    • pp.161-168
    • /
    • 2009
  • 본 논문에서는 다양한 장애를 가진 사용자들을 위한 지능형 휠체어의 인터페이스를 제안한다. 제안된 시스템의 주된 목적은 전동휠체어의 조이스틱을 사용하기 힘든 장애인들에게 효율적인 인터페이스를 제공함으로써 그들의 안전한 이동성을 보장하여 독립적인 삶을 이끌어 나갈 수 있도록 하는 것이다. 이를 위해 제안된 시스템은 사용자의 얼굴 기울기를 인식하여 휠체어의 회전을 수행하고 입 모양을 인식하여 휠체어의 전진과 정지를 수행 한다. 이러한 얼굴 특징을 인식하기 위해 제안된 시스템은 얼굴 특징 검출기, 얼굴 특징 인식기, 전환기로 구성된다. 얼굴 특징 검출기는 Adaboost를 이용하여 얼굴 영역을 먼저 검출한 후 에지 정보를 이용하여 입 영역을 검출한다. 검출된 결과들은 얼굴 특징 인식기에저 statistical analysis와 K-means clustering을 이용하여 얼굴 각도와 입 모양을 인식한다. 전환기는 인식된 결과들을 휠체어의 모터를 제어하기 위한 명령어로 변환하여 사용자의 얼굴 및 입의 움직임으로 휠체어를 제어할 수 있도록 한다. 제안된 지능형 휠체어의 효율성을 증명하기 위하여 34명의 사용자를 대상으로 다양한 환경에서 실험한 결과 제안된 시스템은 전동 휠체어의 조이스틱을 사용 할 수 없는 장애인들에게 편리한 이동성을 제공하며, 보다 편리하고 친숙한 인터페이스로 사용 될 수 있음을 보여 주었다.

Effectiveness of Ultrasonographic Screening for Thyroid Cancer: Round-table Conference in the National Evidence-based Healthcare Collaborating Agency (NECA) in conjunction with the Korean Thyroid Association

  • Shin, Sangjin;Park, Sae Eun;Kim, Soo Young;Hyun, Min Kyung;Kim, Sun Wook;Kwon, Jin Won;Kim, Yeol;Kim, Won Bae;Na, Dong Gyu;Park, Hyun-Ah;Sheen, Seung Soo;Yi, Ka Hee;Chang, Hang-Seok;Cho, Jung Jin;Chung, Jae Hoon
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권12호
    • /
    • pp.5107-5110
    • /
    • 2014
  • Background: The incidence rate of thyroid cancer has been increasing worldwide in recent years, and it is also the most prevalent cancer when it comes to the number of patients among Korean women. With it, ultrasonographic screening test has also become very common. However, there is still controversy over the performance of this screening test. Therefore, the National Evidence-based Healthcare Collaborating Agency (NECA) organized a Round-table Conference on the issues regarding ultrasonographic screening for thyroid cancer in Korea. The objective of the conference was mainly about delivering worthwhile information reflecting social value for the current situation, which was based on evidence surrounding thyroid cancer screening that relevant experts investigated and agreed on. The significance of this Round-table Conference lies in the fact that we reviewed the current evidence, and we were able to discuss the social value and future direction for ultrasonographic screening in Korea.

Contrast reference values in panoramic radiographic images using an arch-form phantom stand

  • Shin, Jae-Myung;Lee, Chena;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • 제46권3호
    • /
    • pp.203-210
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate appropriate contrast reference values (CRVs) by comparing the contrast in phantom and clinical images. Materials and Methods: Phantom contrast was measured using two methods: (1) counting the number of visible pits of different depths in an aluminum plate, and (2) obtaining the contrast-to-noise ratio (CNR) for 5 tissue-equivalent materials (porcelain, aluminum, polytetrafluoroethylene [PTFE], polyoxymethylene [POM], and polymethylmethacrylate [PMMA]). Four panoramic radiographs of the contrast phantom, embedded in the 4 different regions of the arch-form stand, and 1 real skull phantom image were obtained, post-processed, and compared. The clinical image quality evaluation chart was used to obtain the cut-off values of the phantom CRV corresponding to the criterion of being adequate for diagnosis. Results: The CRVs were obtained using 4 aluminum pits in the incisor and premolar region, 5 aluminum pits in the molar region, and 2 aluminum pits in the temporomandibular joint (TMJ) region. The CRVs obtained based on the CNR measured in the anterior region were: porcelain, 13.95; aluminum, 9.68; PTFE, 6.71; and POM, 1.79. The corresponding values in the premolar region were: porcelain, 14.22; aluminum, 8.82; PTFE, 5.95; and POM, 2.30. In the molar region, the following values were obtained: porcelain, 7.40; aluminum, 3.68; PTFE, 1.27; and POM, - 0.18. The CRVs for the TMJ region were: porcelain, 3.60; aluminum, 2.04; PTFE, 0.48; and POM, - 0.43. Conclusion: CRVs were determined for each part of the jaw using the CNR value and the number of pits observed in phantom images.

구강검진의 효과 증진을 위한 파노라마방사선사진의 필요성에 관한 연구 (Usefullness of panoramic radiograph for the improvement of periodic oral examination)

  • 신민정;최보람;허경회;이원진;허민석;이삼선;최순철
    • Imaging Science in Dentistry
    • /
    • 제40권1호
    • /
    • pp.25-32
    • /
    • 2010
  • Purpose : This study was designed to evaluate the efficacy and utility of panoramic radiograph for the improvement of the periodic oral examinations. Materials and Methods : Clinical examinations and panoramic examinations were done for the 242 subjects of oral examinations. The results of panoramic radiograph interpretation were compared with the clinical findings. Two questionnaires were created. One was carried out before the panoramic examination and the other done afterwards, to find out the subjects' cognition and satisfaction for the clinical and panoramic examinations. Results : 1. Panoramic findings showed a higher detection rate of 31.9% for periodontal diseases, and 23.1% for dental caries than clinical findings. 2. The additional abnormalities detected through panoramic examinations were impacted tooth in 81 subjects (33.6%), maxillary sinus abnormalities in 28 subjects (11.6%), condylar abnormalities in 5 subjects (2.1%), congenital and acquired dental anormalies in 59 subjects (24.5%), and other miscellaneous abnormalities in 34 subjects (14.1%). 3. 164 subjects (67.8%) were satisfied with the current periodic oral examination, and 75 subjects (31.1%) hoped for better accuracy. 4. In the first and second questionnaire, 154 subjects (67.0%) and 163 subjects (70.6%) responded respectively that panoramic examination was necessary, and 193 subjects (83.2%) responded that it actually helped. Conclusion : The panoramic examination was revealed to improve the effectiveness of the periodic oral examination and to increase the satisfaction of the subjects of examination.

순환잔골재 및 플라이애시가 PVA 섬유보강 시멘트 복합체의 역학적 특성에 미치는 영향 (Effect of Recycled Fine Aggregates and Fly Ash on the Mechanical Properties of PVA Fiber-Reinforced Cement Composites)

  • 남의현;박완신;장영일;윤현도;김선우
    • 콘크리트학회논문집
    • /
    • 제29권2호
    • /
    • pp.149-157
    • /
    • 2017
  • 건설 폐기물 양이 증가하면서, 순환재료의 재사용은 건설 분야 중에서도 학문적으로 활발하게 연구되고 있는 분야로 자리 매김하고 있다. 이에 따라 순환재료를 사용한 모르타르 및 콘크리트 품질의 개선과 역학적 특성을 규명하고자 하는 연구는 활발하게 진행되고 있지만, 순환재료를 사용한 섬유보강 시멘트 복합체에 대한 연구는 많지 않다. 본 연구에서는 순환잔골재 및 플라이애시가 PVA 섬유보강 시멘트 복합체의 역학적 특성에 미치는 영향에 대해서 실험적으로 분석하고자 하였다. 순환잔골재 및 플라이애시 치환율은 25% 및 50%로 설정하였으며, 순환재료 치환율에 따른 10개의 PVA 섬유보강 시멘트 복합체의 휨, 압축 및 인장거동을 실험적으로 평가하였다. 실험결과 플라이애시 치환율이 증가함에 따라 휨, 압축, 직접인장강도가 감소하였다. 특히 순환잔골재 및 플라이애시를 각각 50% 치환하는 경우 강도가 가장 낮게 나타났다. 탄성계수는 재령 28일에서의 압축강도와 유사한 경향을 나타냈으며, 푸아송 비는 순환잔골재 및 플라이애시 치환율이 증가함에 따라 크게 나타났다.

SMART-ITL 1 계열 피동안전계통을 이용한 안전주입배관 파단 소형냉각재상실사고 모의에 대한 실험적 연구 (Experimental Study of SBLOCA Simulation of Safety-Injection Line Break with Single Train Passive Safety System of SMART-ITL)

  • 류성욱;배황;유효봉;변선준;김우식;신용철;이성재;박현식
    • 대한기계학회논문집B
    • /
    • 제40권3호
    • /
    • pp.165-172
    • /
    • 2016
  • 노심보충탱크(Core Makeup Tank, CMT), 안전주입탱크(SafetyInjection Tank, SIT)와 자동감압계통(Auto Depressurization System, ADS)로 구성된 1 계열의 SMART 피동안전주입계통의 주입특성을 파악하기 위한 소형냉각재상실사고(SBLOCA) 모의에 대한 실험적 연구가 수행되었다. SBLOCA의시험은 0.4 인치 안전주입수 배관파단에 대해 수행되었으며, 정상상태 조건은 실험요건서에 제시된 시험 초기 조건을 만족시키도록 746초 동안 운전되었다. 노심 출력 및 안전주입 유량 등의 경계 조건도 적절히 모의되었으며, 안전주입계통 배관에서의 파단, 히터 트립 및 잔열곡선 인가, 원자로냉각재펌프 관성서행(Coastdown), 급수 중단, CMT 및 SIT의 주입, ADS #1 개방이 SBLOCA 시나리오에 따라 적절히 모의되었다. 노심지지원통 내부의 액체환산수위는 파단 초반에 감소하다가 CMT와 SIT가 주입되면서 서서히 회복되었으며, 피동안전주입계통의 주입유량이 노심 수위를 회복하기에 충분한 것으로 판단할 수 있다.