• Title/Summary/Keyword: Xenon lamp

Search Result 112, Processing Time 0.025 seconds

Pulse Density Modulated Zero Voltage Soft-Switching High-Frequency Inverter with Single Switch for Xenon Gas Dielectric Barrier Discharge Lamp Dimming

  • Sugimura, Hisayuki;Suh, Ki-Young;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.391-394
    • /
    • 2006
  • This paper presents soft switching zero voltage switching high frequency inverter for rare gas fluorescent lamp using dielectric-barrier discharge phenomenon. The simple high-frequency inverter can completely achieve stable zero voltage soft switching (ZVS) commutation for wide its output power regulation ranges and load variations under its constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operating principle is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZVS operation commutation, together with its output effective power regulation characteristics-based on the high frequency PDM strategy. The experimental operating performances of this high frequency Inverter are illustrated as compared with computer simulation results and experimental ones. Its light dimming characteristics due to power regulation scheme are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliance implemented here is proven from the practical point of view.

  • PDF

Study on the Design of a High Condensing LED Searchlight

  • Kim, Tae-Seong;Kim, Jin-Wook;Kim, Sun-Jae;Kil, Gyung-Suk
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.4
    • /
    • pp.201-205
    • /
    • 2015
  • This paper dealt with the condensing technology of an LED light source that uses a parabolic reflector to replace a searchlight equipped with a xenon lamp. A ray-tracing simulation was conducted to analyze the influence of the diameter of the reflector and the size of the light source on light condensing. The combination of a parabolic reflector with a diameter of 620 mm and a focal distance of 220 mm, and a 9 mm multi-chip package (MCP) with a luminous flux of 7,000 lm showed the narrowest beam angle. The luminous intensity at the center was measured at 7.7×106 cd. The distance between the light source and the point where the illuminance was 1 lx was calculated to be 2.8 km. The power consumption of the system was 95 W, which is only 9.5% of that of the 1 kW xenon searchlight, and the beam angle was 1.03°. In a site experiment, it was confirmed that the light ray reflected from the LED searchlight proceeds forward without any diffusion because of the narrow beam angle.

The Influence of Weathering Conditions on the Outer Membrane of Biogas with Plasticized PVC : A Study using Non-destructive Tests

  • Kim, Changhwan;Ki, Wootae;Kim, SangMyung;Shin, Jinyong
    • Journal of the Korean institute of surface engineering
    • /
    • v.47 no.2
    • /
    • pp.57-62
    • /
    • 2014
  • The biogas holder is composed of an outer membrane and an inner membrane which are subject to outdoor exposure and gas exposure respectively. The influence of weathering conditions on the photo-degradation of a biogas holder was investigated. Tests were performed under three different methods - outdoor exposure tests (Seosan, Arizona), accelerated tests (Xenon-are lamp) with the outer-membrane of biogas. Moreover, the changes in the aging process were monitored using color difference, gloss, the contact angle and an optical microscope. Changes in physical properties, such as decrease reduction in gloss, decrease in the contact angle, increase in color difference were observed in the aging process. The comparison between membrane 3B, 4B and membrane 5B under xenon-arc were discussed. Membrane 5B was very sensitive to ultraviolet (UV) ray. There were many difficulties in the outdoor exposure test due to acid rain, dust, and stain resistance.

Hazards Caused by UV Rays of Xenon Light Based High Performance Solar Simulators

  • Dibowski, Gerd;Esser, Kai
    • Safety and Health at Work
    • /
    • v.8 no.3
    • /
    • pp.237-245
    • /
    • 2017
  • Background: Solar furnaces are used worldwide to conduct experiments to demonstrate the feasibility of solar-chemical processes with the aid of concentrated sunlight, or to qualify high temperature-resistant components. In recent years, high-flux solar simulators (HFSSs) based on short-arc xenon lamps are more frequently used. The emitted spectrum is very similar to natural sunlight but with dangerous portions of ultraviolet light as well. Due to special benefits of solar simulators the increase of construction activity for HFSS can be observed worldwide. Hence, it is quite important to protect employees against serious injuries caused by ultraviolet radiation (UVR) in a range of 100 nm to 400 nm. Methods: The UV measurements were made at the German Aerospace Center (DLR), Cologne and Paul-Scherrer-Institute (PSI), Switzerland, during normal operations of the HFSS, with a high-precision UV-A/B radiometer using different experiment setups at different power levels. Thus, the measurement results represent UV emissions which are typical when operating a HFSS. Therefore, the biological effects on people exposed to UVR was investigated systematically to identify the existing hazard potential. Results: It should be noted that the permissible workplace exposure limits for UV emissions significantly exceeded after a few seconds. One critical value was strongly exceeded by a factor of 770. Conclusion: The prevention of emissions must first and foremost be carried out by structural measures. Furthermore, unambiguous protocols have to be defined and compliance must be monitored. For short-term activities in the hazard area, measures for the protection of eyes and skin must be taken.

Design of the self-oscillation UV flash lamp power supply and the characteristic of its operation using self-resonance of the transformer (트랜스포머의 자가 공진(Self-Resonance)특성을 이용한 자가 발진(Self-Oscillation) UV(Ultra Violet) 발생 플래시램프 전원장치설계 및 그 동작 특성)

  • Kim, Shin-Hyo;Cho, Dae-Kweon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.48-55
    • /
    • 2014
  • These Xenon flashlamp power supply for Ultra Violet has converter with high voltage conversion ratio. General model is composed of transformer with high voltage conversion ratio and voltage doubler rectifier circuit. Purpose of power supply leads dielectric breakdown of Xenon flashlamp and passes current rapidly. When passing current, it has to limit current to avoid over-heat, damage of electrode and acceleration of gas oxidation which are cause of performance degradation of lamps. Generally, inductors and resistors, which are called as "Ballast," are used to limit currents. Generally, Transformer has high turn ratio to make high voltages. But we can get high voltages using the transformer with low turn ratio which is driven with self resonance. Also, an advantage of self resonance is to make a circuit simply through impedance of transformer in resonance frequency which filters output voltage. As using an unique impedance of transformer, the circuit does not need other impedance elements like the ballast. So the power supply assures high efficiency of the arc discharge.

Control of the Photo-induced Discoloration of the Handmade Korean Paper with Polyethylene Glycol (Polyethylene Glycol에 의한 수록한지(手漉韓紙)의 광(光) 변색(變色) 억제(抑制))

  • Cheon, Cheol;Park, Soo-Ahn
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.2
    • /
    • pp.161-166
    • /
    • 2000
  • Classified handmade Korean paper which has been commonly used as the material for the paper cultural assets divide into four classes. We irradiated xenon arc lamp, which has almost the same spectrum distribution as natural sunlight, to test photo-induced of discoloration according to PEG molecular weight and concentration. So, we reach the followings. 1) Unbleached handmade Korean paper with PEG showed rapid decrease of brightness for 10 hours after photo-irradiation, regardless of molecular weight of PEG, but, after 10 hours, it showed gradual increase of brightness. From this, it proved that there was an effect of preventing discoloration of photo-irradiation. 2) Chemical bleached handmade Korean paper showed increase of brightness after 20 hours. Though time was delayed in increase of brightness, there was also an effect of preventing discoloration of photo-irradiation in chemical bleached paper. 3) Handmade Korean paper made with abet-mosk showed the lowest of brightness when it was tested on 400-20% PEG. Before photo-irradiation, the brightness of paper, applied it, was the lowest, but it showed the least difference of brightness after photo-irradiation. From this, it proved that there was the greatest effect of preventing discoloration in this paper. 4) Preventing yellowish, the first phenomena by photo-irradiation ageing with applying PEG was proved that there was the decrease of value of $b^*$ +, and increase value of $L^*$, which could fairly prevent decrease of brightness.

  • PDF

Photodegradation of Cellulosics(Part II) - Chemical Properties of Irradiated Cotton - (Cellulose의 광분해에 관한 연구(II) - 광조사된 면섬유의 화학적 성질을 중심으로 -)

  • 전경숙
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.18 no.1
    • /
    • pp.15-22
    • /
    • 1994
  • The formation of carbonyl group was dominant to other functional groups. Concentrations of both carboxyl and peroxide groups were found to rapidly reach low steady state values that increased slightly with increa-sing temperature and relatice humidity. Since the deg-radation of cellulose samples was in the initial stage and the conversion of glycosidic bonds and hydroxyl groups were very small, it was found that changes in the physical and chemical properties could be fitted to a first-order reaction model.

  • PDF

Development of a precision smoke particle detector to sense a fire in early state (초기화재 감지를 위한 정밀한 연기 입자 감지 장치 개발)

  • 김희식;김영재;이호재
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1734-1737
    • /
    • 1997
  • The conventional fire detection devices are operated after a processed fire phase, which are sensing only a high density of somke level or high temperature heat. They are not so precision to detect a fire in the early phase to protect the facility form the fire. We need to develope a new high precision smoke detection system to keep expensive industrial facilities most reliably form fire. A new optical precision smoke detection system was developed. It monitors very low level density of smoke particles in the air. It is operated continously through many years without a stop or any malfunction. The developed precision smoke detection system will be installed in important industrial facilities, such as power plants, underground common tunnel, main control rooms, computer rooms etc.

  • PDF

Solar Steam Reforming of Methane utilizing Solar Simulator (Solar Simulator를 이용한 메탄의 수증기 개질 반응)

  • Do, Han-Bin;Han, Gui-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.186-189
    • /
    • 2008
  • Solar simulator를 이용한 메탄의 수증기 개질은 집광된 태양에너지를 이용하기 위한 목적으로 수행되었다. 본 연구에서는 이와 같은 태양열에너지의 화학적 축열을 실시하기 위해 Solar Simulator를 이용한 메탄의 수증기 개질을 연구하였다. 태양열 모사 램프로 1.2kW급 Xenon-arc lamp를 사용하였다. 반응기는 앞면의 Quartz Window와 촉매지지층으로 구성되어 있다. 램프의 빛은 Quartz Window를 통하여 촉매층에 직접적으로 방사되고, 방사된 빛으로 촉매지지층에서 흡열반응이 일어난다.메탄의 수증기개질 반응은 고온에서 일어나기 때문에 촉매지지체를 열에 강한 SiC로 만들어진 Ceramic foam을 사용하였다. 이 촉매지지체에 촉매를 Wash-coat하여 사용하였으며, 담지된 촉매는 Ni을 활성성분으로 하는 ICI 46-6을 사용하였다. 반응기는 318 SUS 재질로 제작되었으며, 반응기 외부는 Insulation을 하여 열손실을 감소시켰다. 실험은 온도와 공간속도에 따른 Solar Steam reforming의 반응특성을 분석하였다.

  • PDF

A Study on the Extraction of Soluble Colorants of the Gardenia jasminoides Ellis (수용성 치자 색소의 추출에 관한 연구)

  • Kim, Kwang Soo;Kim, Yeon Joong
    • Textile Coloration and Finishing
    • /
    • v.9 no.3
    • /
    • pp.10-17
    • /
    • 1997
  • The study was performed to obtain the optimum extraction conditions for crocin from gardenia fructus. Generally crocin is unstable on heat, light, acid and base solution. The extraction efficiency of crocin from gardenia depended upon the extraction time, extraction temperature, pH in the extraction bath and the optimum conditions of crocin extraction were determined as 60 minutes of extraction time, 4$0^{\circ}C$ of extraction temperature, pH 7 of extraction bath. The molar extinction coefficient of crocin was 12,515 and the color yield of purified crocin was about six times higher than that of non-purified crocin. The heat-stability at extraction temperature and lightstability in irradiation with xenon lamp for one hour of the purified crocin were higher than those of non-purified crocin. Intensity of &{\lambda}_{max}&of crocin was decreased by irradiation for one hour but UV-Vis. spectra of crocin was not changed. The colors of purified and non-purified crocin dissolved wit methanol was evaluated by means of CIE L* a* b* system.

  • PDF