• Title/Summary/Keyword: X2 test

Search Result 4,239, Processing Time 0.037 seconds

Factors associated with Pediatric Delirium in the Pediatric Intensive Care Unit (소아중환자실 입원 아동의 섬망 발생 관련 요인)

  • Kim, Hyo Jin;Kim, Dong Hee
    • Child Health Nursing Research
    • /
    • v.25 no.2
    • /
    • pp.103-111
    • /
    • 2019
  • Purpose: This study aimed to investigate incidence of delirium in the pediatric intensive care unit (PICU) and to analyze associated risk factors. Methods: The participants were 95 patients, newborn to 18 years, who were admitted to the PICU. The instruments used were the Richmond Agitation Sedation Scale (RASS), and the Cornell Assessment of Pediatric Delirium. Data analysis was performed using the descriptive, $x^2$ test, t-test, and logistic regression analyses. Results: The incidence of delirium in children admitted to the PICU was 42.1%. There were significant differences according to age ($x^2=14.10$, p=.007), admission type ($x^2=7.40$, p=.007), use of physical restraints ($x^2=26.11$, p<.001), RASS score ($x^2=14.80$, p=.001), need for oxygen ($x^2=5.31$, p=.021), use of a mechanical device ($x^2=9.97$, p=.041), feeding ($x^2=7.85$, p=.005), and the presence of familiar objects ($x^2=29.21$, p<.001). Factors associated with the diagnosis of delirium were the use of physical restraint (odds ratio [OR]=13.82, 95% confidence interval [CI]=4.16~45.95, p<.001) and the presence of familiar objects (OR=0.09, 95% CI=0.03~0.30, p=.002). Conclusion: Periodic delirium assessments and intervention should be actively performed. The use of restraints should be minimized if possible. The caregiver should surround the child with familiar objects and ensure a friendly hospital environment that is appropriate for the child.

Effects of Sexual Knowledge and Consciousness on Sexuality Course on University Students (성관련 강좌가 대학생들의 성지식에 미치는 효과)

  • Kim, Young-Seon;Son, Su-Gyeong
    • Journal of the Korean Society of School Health
    • /
    • v.18 no.1
    • /
    • pp.83-93
    • /
    • 2005
  • Purpose: The purpose of this study was to confirm the effects of lectures on sexuality and investigate changes in students' sexual knowledge and consciousness. Method: The subjects in this study were 50 students at K University in Busan, and the research period was from the $8^{th}$ of March to the $7^{th}$ of June 2004. This study was designed to be one-group pretest-posttest. Data were analyzed by frequencies, percentages, means, standard deviations, paired t-test and $x^2$-test using the SPSS 10.0 program. Results: 1. The score of sexual knowledge increased from 14.48 before the education to 15.70 after and the difference was statistically significant (t=3.926, p<.001). 2. Significant differences of sexual consciousness were observed in 'the extent of sexual behavior' ($x^2$=12.584, p<.05), 'the meaning of intercourse' ($x^2$=46.014, p<.001), 'the self attitude of premarital purity' ($x^2$=84.686, p<.001), 'the premarital intercourse' ($x^2$=75.323, p<.001), 'the definition of purity' ($x^2$=23.770, p<.001), 'the general premarital purity attitude' ($x^2$=32.305, p<.001), 'the conception of love, sex and marriage' ($x^2$=38.452, p<.001) and 'the premarital sex experiences' ($x^2$=50.210, p<.001). Conclusions: This study showed that a sexuality course has effects on increasing sexual knowledge and changing the consciousness in university students.

Effect of surface treatment of FRC-Post on bonding strength to resin cements (FRC-포스트의 표면처리가 레진시멘트와의 접착력에 미치는 영향)

  • Park, Chan-Hyun;Park, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.2
    • /
    • pp.125-131
    • /
    • 2011
  • Objectives: The purpose of this study was to evaluate the effect of surface treatment of FRC-Post on bonding strength to resin cements. Materials and Methods: Pre-surface treated LuxaPost (DMG), Rely-X Fiber Post (3M ESPE) and self adhesive resin cement Rely-X Unicem (3M ESPE), conventional resin cement Rely-X ARC (3M ESPE), and Rely-X Ceramic Primer (3M ESPE) were used. After completing the surface treatments of the posts, posts and resin cement were placed in clear molds and photo-activation was performed. The specimens were sectioned perpendicular to the FRC-Post into 2 mm-thick segments, and push-out strength were measured. The results of bond strength value were statistically analyzed using independent samples t-test and oneway ANOVA with multiple comparisons using Scheffe's test. Results: Silanization of posts affect to the bond strength in LuxaPost, and did not affect in Rely-X Fiber Post. Rely-X ARC showed higher value than Rely-X Unicem. Conclusions: Silanization is needed to enhance the bond strength between LuxaPost and resin cements.

The Research for Skin Condition Related with Physiological Phenomenon (여성의 생리적인 현상에 따른 피부상태와의 상관성 관련 요인에 관한 연구)

  • Lee, Jun-Cheol
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.2
    • /
    • pp.207-216
    • /
    • 2021
  • This study was conducted on 315 women in their 20s and 40s living in Changwon, South Gyeongsang Province, and recorded in a self-recorded format using the questionnaire survey method. In this study, the skin type according to the skin condition was not applied for 30 minutes after washing and checking the cheek area through the examination method to distinguish it by intelligence, neutral, dryness and boredom to see the interaction with each condition. The X2-test was conducted to find out the relevance between each factor and the data processing was done using PC/SAS. We reached at following conclusions. We can find some connections between skin condition and age, job, marriage by statistics(p<0.01). Each value of X2-TEST was 42.961(p<0.001) and 7.345(p<0.05). The pimples are shown after stress on cheek, chin and around neck easily. We also find some connections between skin trouble reaction and the beginning of pimple shown time(p<0.01).

Testing for $P(X_{1}\;<\;X_{2})$ in Bivariate Exponential Model with Censored Data (중단자료를 갖는 이변량 지수 모형에서 $P(X_{1}\;<\;X_{2})$에 대한 검정)

  • Park, Jin-Pyo;Cho, Jang-Sik
    • Journal of the Korean Data and Information Science Society
    • /
    • v.8 no.2
    • /
    • pp.143-152
    • /
    • 1997
  • In this paper, we obtain maximum likelihood estimators for $P(X_{1}\;<\;X_{2})$ in the Marshall and Olkin's bivariate exponential model with bivariate censored data. The asymptotic normality of the estimator is derived. Also we propose approximate testing for $P(X_{1}\;<\;X_{2})$ based on the M.L.E. We compare the test powers under vsrious conditions through Monte Carlo simulation.

  • PDF

On Two-Piece Double Exponential Distribution

  • Lingappaiah, G.S.
    • Journal of the Korean Statistical Society
    • /
    • v.17 no.1
    • /
    • pp.46-55
    • /
    • 1988
  • Two-piece double exponential distribution (TPDE) with one piece $(X \leq 0)$ having the scale parameter $\theta_1$ while the other piece (X>0) having $\theta_2$ is considered here. Distribution of the sum of n-independent variables from such a distribution is obtained. Special cases of this distribution are also treated. Next, distribution of the ratio of two independent (TPDE) variables is derived. As an extension, distribution of $x_1/x_2x_3$ is expressed terms of hypergeometric functions. A small table gives the power of the test regarding double exponential against (TPDE).

  • PDF

Effects of Wet Chemical Treatment and Thermal Cycle Conditions on the Interfacial Adhesion Energy of Cu/SiNx thin Film Interfaces (습식표면처리 및 열 사이클에 따른 Cu/SiNx 계면접착에너지 평가 및 분석)

  • Jeong, Minsu;Kim, Jeong-Kyu;Kang, Hee-Oh;Hwang, Wook-Jung;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.1
    • /
    • pp.45-50
    • /
    • 2014
  • Effects of wet chemical treatment and thermal cycle conditions on the quantitative interfacial adhesion energy of $Cu/SiN_x$ thin film interfaces were evaluated by 4-point bending test method. The test samples were cleaned by chemical treatment after Cu chemical-mechanical polishing (CMP). The thermal cycle test between Cu and $SiN_x$ capping layer was experimented at the temperature, -45 to $175^{\circ}C$ for 250 cycles. The measured interfacial adhesion energy increased from 10.57 to $14.87J/m^2$ after surface chemical treatment. After 250 thermal cycles, the interfacial adhesion energy decreased to $5.64J/m^2$ and $7.34J/m^2$ for without chemical treatment and with chemical treatment, respectively. The delaminated interfaces were confirmed as $Cu/SiN_x$ interface by using the scanning electron microscope and energy dispersive spectroscopy. From X-ray photoelectron spectroscopy analysis results, the relative Cu oxide amounts between $SiN_x$ and Cu decreased by chemical treatment and increased after thermal cycle. The thermal stress due to the mismatch of thermal expansion coefficient during thermal cycle seemed to weaken the $Cu/SiN_x$ interface adhesion, which led to increased CuO amounts at Cu film surface.

Surface Analysis of Ni-Cr and Co-Cr Alloys with Addition of Ti and Mo for Dental CAD/CAM Use (Ti 및 Mo 첨가에 따른 치과 CAD/CAM용 Ni-Cr 및 Co-Cr합금의 표면분석)

  • Moon, Dae-Sun;Choe, Han-Cheol
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.3
    • /
    • pp.139-148
    • /
    • 2018
  • In this study, surface analysis of Ni-Cr and Co-Cr alloys with addition of Ti and Mo for dental CAD/CAM use has been researched experimentally. The surface characteristics of the alloys were examined by Vickers hardness test, bonding strength test, surface roughness test, field-emission scanning electron microscopy, energy dispersive X-ray spectroscopy, and X-ray diffraction spectroscopy. The shrinkage of the sintered Ni-Cr alloy alloy was slightly larger than that of Ni-Cr-Ti alloy, and larger than Co-Cr alloy. Also, the addition of Mo showed a tendency to decrease shrinkage somewhat. From the result of XRD analysis, NiCr, $Ni_3Cr$ and $Ni_3Ti$ were observed in the sintered Ni-13Cr-xTi and Ni-13Cr-xMo alloys. In addition, ${\sigma}-CrCo$, $Co_2Mo_3$ and $TiCo_2$ were formed in the sintered Co-Cr-xTi and Co-Cr-xMo alloys. Surface hardness of Ti and Mo added alloy was higher than those of Ni-Cr and Co-Cr alloy. The bond strength between sintered alloy and porcelain was $16.1kgf/mm^2$ for Ni-13Cr alloy, $17.8kgf/mm^2$ for Ni-13Cr-5Ti alloy, and $8.2kgf/mm^2$ for Ni-13Cr-10Ti alloy, respectively.

Antibacterial property and characterization of CuSn thin films deposited by RF magnetron co-sputtering method

  • Gang, Yu-Jin;Park, Ju-Yeon;Kim, Dong-U;Kim, Hak-Jun;Gang, Yong-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.360.2-360.2
    • /
    • 2016
  • CuSn thin films were fabricated by rf magnetron co-sputtering method on the Si(100) substrate for evaluation of the antibacterial effect. The co-sputtering process was performed with different rf powers and sputtering times to regulate the thickness of the films and relative atomic ratio of Cu to Sn. The physicochemical properties of the CuSn thin films were characterized by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), X-ray induced Auger electron spectroscopy (XAES), Optical microscope (OM), 4-point probe, and antibacterial test. An antibacterial test was conducted with Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus) as changing contact times between CuSn fillms and bacteria suspension. We compared to the crystalline structures of films before sterilization and after sterilization by XRD measurement. The changes of oxidation states of Cu and Sn and the chemical environment of films before and after antibacterial test were investigated with high resolution XPS spectra in the regions of Cu 2p, Cu LMM, and Sn 3d. After antibacterial test, the morphology of the films was checked with an OM images. The electrical properties of the CuSn films such as surface resistance and conductivity were measured by using 4-point probe.

  • PDF

Medical Clinics' quality Management of X-ray Units in Gyeongbuk Area (경북 지역 의원급의 X선 발생장치 정도관리 실태)

  • Park, Jeong-Kyu
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.9
    • /
    • pp.267-275
    • /
    • 2010
  • Quality management of an x-ray unit drastically differs according to the type of establishment of medical institutions. Many primary medical institutions have it, but they do not pay much attention to quality management. In the study, Gyeongbuk area has been divided into four zones from January 4, 2010 to September 3, 2010, and four places were designated by city. Among medical institutions located at a total of 16 sites, the target was 8 places with X-ray emission equipment 10 years or more in use as well as 8 places with X-ray emission equipment less than 10 years in use. The 5 essential items of quality control were tested. In the test that checked for equipment it was found that sites with X-ray emission equipment 10 years or more in use didn't have ground connection (6.25%) while all of them passed the current leak test. In the exposure dose reproducibility test 4 sites with X-ray emission equipment 10 years or more in use (25%) and 1 site with X-ray emission equipment less than 10 years in use didn't pass the test. In the KVp accuracy test 5 sites with X-ray emission equipment 10 years or more in use (31.25%) and 2 sites with X-ray emission equipment less than 10 years in use (12.5%) didn't pass the test. In the tube current and tube current amount test 3 sites with X-ray emission equipment 10 years or more in use (18.75%) and 1 site with less than 10 years in use (6.25%) didn't pass the test. According to the findings of the present research, quality control at medical institutions with X-ray equipment 10 years or more in use was poorer than medical institutions with X-ray equipment less than 10 years in use. In this regard, administrative and technical measures need to be taken as soon as possible. In addition, owners of medical clinics or unit managers need to raise awareness, and it is necessary to revise a regular test cycle every year or every two years if they have old equipment or if the equipment is not used on a frequent basis. And it is also important to provide regular educational programs for quality management.