Calibration-free real-time organic film thickness monitoring technique by reflected X-Ray fluorescence and compton scattering measurement

  • Park, Junghwan;Choi, Yong Suk;Kim, Junhyuck;Lee, Jeongmook;Kim, Tae Jun;Youn, Young-Sang;Lim, Sang Ho;Kim, Jong-Yun
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1297-1303
    • /
    • 2021
  • Most thickness measurement techniques using X-ray radiation are unsuitable in field processes involving fast-moving organic films. Herein, we propose a Compton scattering X-ray radiation method, which probes the light elements in organic materials, and a new simple, non-destructive, and non-contact calibration-free real-time film thickness measurement technique by setting up a bench-top X-ray thickness measurement system simulating a field process dealing with thin flexible organic films. The use of X-ray fluorescence and Compton scattering X-ray radiation reflectance signals from films in close contact with a roller produced accurate thickness measurements. In a high-thickness range, the contribution of X-ray fluorescence is negligible, whereas that of Compton scattering is negligible in a low-thickness range. X-ray fluorescence and Compton scattering show good correlations with the organic film thickness (R2 = 0.997 and 0.999 for X-ray fluorescence and Compton scattering, respectively, in the thickness range 0-0.5 mm). Although the sensitivity of X-ray fluorescence is approximately 4.6 times higher than that of Compton scattering, Compton scattering signals are useful for thick films (e.g., thicker than ca. 1-5 mm under our present experiment conditions). Thus, successful calibration-free thickness monitoring is possible for fast-moving films, as demonstrated in our experiments.

디스플레이용 PDP의 X-ray에 대한 반응특성 평가

  • Yun, Min-Seok;Jo, Seong-Ho;Gang, Sang-Sik;Cha, Byeong-Yeol;Kim, So-Yeong;Son, Dae-Ung;Heo, Seung-Uk;Nam, Sang-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.531-531
    • /
    • 2007
  • 현재 널리 사용되고 있는 X선 영상 검출기의 문제점을 해결하기 위해 새로운 연구가 활발히 진행되고 있다. 본 논문에서는 새로운 X선 검출기로써의 가능성 제시를 위해 Display용 PDP(Plasma Display panel)를 디지털 X-ray Detector로 적용하기 위한 기본적인 X-ray에 대한 반응성을 검증하였다. PDP의 X-ray Detector로의 사용 가능성을 보기 위하여, 실험에 사용된 panel은 상용화된(commercial) Display용 PDP의 기본적인 구조와 똑같은 구조의 sample을 제작하여 사용하였다. 제작된 panel은 상판에 Substrate glass와 유전체층, 투명전극을 형성하고, 버스 전극층과 MgO층을 형성하였다. 하판에는 격벽을 제작하고 형광체(R.G.B)층을 형성하고, 어드레스 전극을 형성하여 기존의 Display용 PDP와 똑같은 구조를 지니게 하였다. 이렇게 제작된 panel의 X-선 검출기로서의 전기적 특성물 조사하기 위해 누설전류(Dark current), X선 민감도(X-ray sensitivity), 그리고 선형특성(Linearity)을 측정하였다. 측정 결과, 누설전류가 낮고 X-선 검출기로서의 가능성이 충분한 민감도를 보이며, 선형적 특성 또한 우수한 결과를 보이는 등 안정된 전기적 동작특성을 보였다. 이러한 결과로부터 기존에 사용되어오던 디스플레이용 PDP의 구조적 변경을 통하여 상용화된 PDP룰 디지털 X-선 검출기로서의 적용 가능성을 확인할 수 있었다.

  • PDF

The characteristic study of hybrid X-ray detector using CdTe and Zns:AgCl phosphor (CdTe 와 ZnS:AgCl phosphor를 이용한 Hybrid형 X선 검출기의 특성연구)

  • Seok, Dae-Woo;Kang, Sang-Sik;Kim, Jin-Young;Park, Ji-Koon;Mun, Chi-Woong;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.71-74
    • /
    • 2003
  • Photoconductor for direct detection fiat-panel imager present a great materials challenge, since their requirement include high X-ray absorption, ionization and charge collection, low leakage current and large area deposition, CdTe is practical material. We report studies of detector sensitivity, That is an CdTe with $5{\mu}m$ thickness on glass. That is hybrid layer of depositting ZnS:AgCl phosphor with $100{\mu}m$ on CdTe. The leakage current of hybrid is similar to it of a-Se, but photocurrent is larger than a-Se. Both of them have high spatial resolution, but hybrid has higher sensitivity than a-Se at comparable bias voltage.

  • PDF

Diagnostic Value of Thoracography in Pneumothorax (기흉에서 흉강조영술(Thoracography)의 진단적 가치)

  • 박영식;한재열;장지원
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.730-734
    • /
    • 1998
  • Background: It is important to know the location, number, size and shape of bullae before thoracotomy or VATS bullectomy. Chest X-ray and chest CT may be used but with some limitation. The purpose of this study was to compare the diagnostic value of thoracography with that of chest X-ray in preoperative detection of bullae. Meterial and Method: Thoracography was performed by injection of non-ionic water-soluble dye into pleural space in 22 primary spontaneous pneumothoraces, which underwent thoracotomy or VATS bullectomy. Chest X-ray and thoracography were compared through operative finding. Results: Sensitivity and accuracy of thoracography(75% and 72.7%) were higher than those of chest X-ray(30% and 36.4%). However, specificity of thoracography(50%) was lower than that of chest X-ray (100%). There were no complications during or after thoracography. Conclusion: Thoracography is a safer and more useful method for preoperative detection of bullae when compared with chest X-ray.

  • PDF

Investigation of CdTe thick films for direct conversion type X-ray detector (CdTe 후막을 이용한 직접변환방식 X-선 검출기 물성평가)

  • Kim, Min-Je;Song, Pung-Geun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.05a
    • /
    • pp.113-113
    • /
    • 2015
  • 본 연구에서는 thermal evaporation법을 이용하여 제작한 CdTe 후막의 미세구조, 전기적 특성 및 X-선 조사에 따른 특성을 비교분석하였다. 기판온도를 $370{\sim}450^{\circ}C$로 변화시키며 증착하였으며, CdCl2 첨가에 따른 미세구조 변화를 관찰하였다. CdTe 막의 상 하부에 전극을 형성하여 I-V 특성을 평가하고, 실제 X-ray를 샘플에 조사하여 sensitivity를 측정하였다. 박막형성 초기에는 기판온도가 증가함에 따라 grain size가 증가하였지만, grain uniformity는 감소하였다. X-ray 특성향상을 위해서는 grain size와 uniformity 모두 중요한 인자이기 때문에 uniformity 향상을 위해 Cl을 첨가하였다. 미량의 Cl 첨가에서는 큰 변화를 보이지 않았지만 더 많은 양의 Cl 첨가 시, grain size 와 uniformity 모두 증가되는 것을 확인하였으며, 그에 따라 I-V, X-ray 조사 특성 모두 개선되는 것을 확인할 수 있었다.

  • PDF

The Study on Composition ratio of Iodine in Hybrid X-ray Sensor (혼합형 X선 센서에서 a-Se 의 Iodine 첨가비 연구)

  • Gong, Hyung-Gi;Park, Ji-Koon;Choi, Jang-Yong;Moon, Chi-Wung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.366-369
    • /
    • 2002
  • At present, the study of direct digital X-ray detector and indirect digital X-ray detector proceed actively. But it needs high thickness and high voltage in selenium for high ionization rate. Therefore, we carried out the study of electric characteristics of a-Se with additive ratio of Iodine in drafting study for developing Hybrid X -ray Sensor for complementing direct digital X -ray detector and indirect digital X-ray detector in this paper. On this, there are formed Amorphous selenium multi-layers by sticking phosphor layer$(Gd_{2}O_{2}S(Eu^{2+}))$ using optical adhesives of EFIRON Co. Amorphous selenium multi-layers having dielectric layer(parylene) has characteristics of low dark-current, high X-ray sensitivity. So we can acquired a enhanced signal to noise ratio. We make Amorphous selenium multi-layers with $30{\mu}m$ thickness on glass.

  • PDF

Effect of Dopping Conditions on a-Se Thin-Films : Microstructural and I-V Study (비정질 박막에 대한 도핑 조건의 영향 및 미세구조와 I-V 연구)

  • 박성광;박지군;강상식;공현기;김진섭;남상희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.492-496
    • /
    • 2001
  • Due to their better photosensitivity in X-ray, the amorphous selenium based photoreceptor is widely used on the X-ray conversion materials. It was possible to control the charge carrier transport of amorphous selenium by suitably alloying a-Se with other elements(e,g. As, Cl). In this paper, We investigated dopants(As, Cl) composition rate to improve dark resistivity and transport properties of charge carrier in amorphous selenium using by direct X-ray conversion material. Alloying a-Se with As inhibits the recrystallization of a-Se but introduces undesirable deep hole traps. then doping with Cl(in the ppm range) compensates for the deep hole traps. We investigated their composition rate in various doping conditions and then obtained optimum dopant composition rate. The result was Se-As 0.3%-Cl 30 ppm and X-ray Sensitivity was 0.57 pc/pixel$.$mR at 137 $\mu\textrm{m}$ x 137 $\mu\textrm{m}$ Pixel area.

  • PDF

BREEDING EXPERIMENT ON MUTATION INDUCTION BY IRRADIATION (2) Effects of X-ray and Thermal Neutron Irradiation on Dry Seeds of Chinese Cabbage and Radish.

  • Kim, Dawng Woo;Kim, Yang Choon;Cho, Mi Kyung
    • Journal of Plant Biology
    • /
    • v.5 no.1
    • /
    • pp.1-6
    • /
    • 1962
  • 1) Germination rate was rather irregular than decreasing as increasing dose of radiation and there were no differences between Kyong-Sam and Chuong-Bang of Chinese cabbage. 2) In R1 generation, abnormal leaves from seedling of irradiated seeds were observed. These were more apparent in X-ray irradiation than in thermal neutron. 3) Seedling height was inhibited with increasing dose of X-ray and thermal neutrons. Growth inhibition was more remarkable in X-ray than in thermal neutron. Kyong-Sam demonstrated more sensitivity than Chyong-Bang in both X-ray and thermal neutron. 4) Seedling height produced from seeds subjected to thermal neutrons showed small variation around its mean value, while in X-irradiation there was a greater deviaton from the mean value. 5) Fertility was decreased as increasing with dose, while the frequency of abortive pollen was increased. There were variability of the fertility and frequency of abortive pollen among plants or branches of a plant. 6) The mutants were obtained more in thermal neutron irradiation than in X-ray. The types of mutations obtained in Chinese radish of R2 generation were abnormal leaf, densely glowing leaf, degeneration in growing point and dwarf. The maximum frequency of phenotypic mutations was abnormal leaf mutation.

  • PDF

Analysis of the Signal Properties of Polycrystalline $HgI_2$ Film Detector under Radiographic Irradiation Condition (X-선촬영 조사 조건하에서 다결정 요오드화수은 박막검출기의 신호특성 분석)

  • Kim, Jong-Eon
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.289-294
    • /
    • 2010
  • The purpose of this study is an evaluation of the performance of a detector under radiographic irradiation condition by fabricating the polycrystalline $HgI_2$ film detector. The polycrystalline $HgI_2$ film detectors with thickness of 210 and $320\;{\mu}m$ were fabricated by screen print technology. Measurements of X-ray sensitivity and dark current were performed for two detectors. And measurements of the linearity of X-ray response and reproducibility were performed for the detector of thickness $320\;{\mu}m$. For applied electric field strengths from 0.05 to $2\;V/{\mu}m$ to the detector of thickness $320\;{\mu}m$, the X-ray sensitivities were measured from 233 to $1,408{\times}106\;electrons/mR{\cdot}mm^2$. And the dark currents were measured from 3.2 to $118\;pA/mm^2$. Compared with values reported by Zhong Su et al., the X-ray sensitivities exhibit about two times larger than the X-ray sensitivities measured by Zhong Su et al. And the dark currents exhibit about nine times larger than the dark currents measured by Zhong Su et al. The linearity of X-ray response acquired 0.988 as a coefficient of correlation (r). Reproducibility acquired 0.002 as a coefficient of variation. This study provides the performance data of fabricated polycrystalline $HgI_2$ film detector available for an active matrix flat panel imager under radiographic irradiation condition.

Study for Enhancement of the Detection Sensitivity in Hand-Held X-Ray Fluorescence Device (휴대용 XRF 장치의 검출감도 향상에 관한 연구)

  • Kim, Sung-Soo;Lee, Youn-Seoung;Kim, Do-Yun;Ko, Dong-Seob
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.6
    • /
    • pp.409-415
    • /
    • 2011
  • The method to improve the detection sensitivity of Hand-held XRF (X-Ray Fluorescence) device currently being developed is discussed. To minimize the loss of the intensity due to atmospheric gas molecules, the vacuum module, which can be filled with atmospheric or He gas, between the sample and the detector was installed. And the change of the detection sensitivity was measured in a vacuum and in the He gas-filled state. As a result, the following three important results were obtained; Firstly, XRF intensity was increased 2~4 times in the low energy range (3~4 keV). It is a very important result because the enhancement of the detection sensitivity means shortening of the detection time in Hand-held XRF device. Secondly, the possibility of detection of the elements less than 3 keV in emission energy was confirmed. Thirdly, the absorption by atmospheric gas molecules can be minimized without vacuum- sealed vessel in Hand-held XRF device, if the vacuum module filled with He gas is used. We concluded that all of three results are very meaningful in the development of a Hand-held XRF device.