Analysis of the Signal Properties of Polycrystalline $HgI_2$ Film Detector under Radiographic Irradiation Condition  

Kim, Jong-Eon (Department of Radiological Science, Kaya University)
Publication Information
Journal of radiological science and technology / v.33, no.3, 2010 , pp. 289-294 More about this Journal
Abstract
The purpose of this study is an evaluation of the performance of a detector under radiographic irradiation condition by fabricating the polycrystalline $HgI_2$ film detector. The polycrystalline $HgI_2$ film detectors with thickness of 210 and $320\;{\mu}m$ were fabricated by screen print technology. Measurements of X-ray sensitivity and dark current were performed for two detectors. And measurements of the linearity of X-ray response and reproducibility were performed for the detector of thickness $320\;{\mu}m$. For applied electric field strengths from 0.05 to $2\;V/{\mu}m$ to the detector of thickness $320\;{\mu}m$, the X-ray sensitivities were measured from 233 to $1,408{\times}106\;electrons/mR{\cdot}mm^2$. And the dark currents were measured from 3.2 to $118\;pA/mm^2$. Compared with values reported by Zhong Su et al., the X-ray sensitivities exhibit about two times larger than the X-ray sensitivities measured by Zhong Su et al. And the dark currents exhibit about nine times larger than the dark currents measured by Zhong Su et al. The linearity of X-ray response acquired 0.988 as a coefficient of correlation (r). Reproducibility acquired 0.002 as a coefficient of variation. This study provides the performance data of fabricated polycrystalline $HgI_2$ film detector available for an active matrix flat panel imager under radiographic irradiation condition.
Keywords
Polycrystalline $HgI_2$ film detector; X-ray sensitivity; Dark current; Reproducibility; Linearity;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Schieber M, Hermon H, Zuck A, at al.: Theoretical and Experiment Ssensitivity to X-rays of Single and Polycrystalline $HgI_{2}$ Compared with Different Single-Crystal Detectors, Nucl. Instr. Meth. Phys. Res. A, 458, 41-46, 2001   DOI   ScienceOn
2 Breen BN, Dagan O,Melekhov L, at al.: Characterization of Mercuric Iodide Photoconductor for Radiographic and Fluoroscopic Medical Imagers, Proc. of the SPIE-Hard X-Ray and Gamma-Ray Detector Physics V, 5198, 134-143, 2003
3 Schieber M, Hermon H, Zuck A, at al.: Thick films of X-ray Polycrystalline Mercuric Iodide Detectors, J. Cryst. Growth, 225, 118-123, 2001   DOI   ScienceOn
4 Zhong Su, Antonuk LE, El-Mohri Y, et al.: Systematic Investigation of the Signal Properties of Polycrystalline HgI2 Detectors under Mammographic, Radiographic, Fluoroscopic and Radiotherapy Irradiation Conditions, Phys. Med. Biol., 50, 2907-2928, 2005   DOI   ScienceOn
5 IEC CD 62220-1.: Medical Electrical Equipment- Characteristics of Digital X-ray Imaging Devices : Determination of the Detective Quantum Efficiency, 2000
6 Kasap SO, Rowlands JA.: Direct-Conversion Flat-Panel X-ray Image Detectors, IEEE Proc. Circuits Devices Syst., 149(2), 85-96, April 2002   DOI   ScienceOn
7 Kasap SO, Rowlands JA.: Direct-Conversion Flat-Panel X-ray Image Sensors for Digital Radiography, Proceeding of the IEEE, 90(4), 591-604, April 2002   DOI   ScienceOn
8 Kasap SO, Zahangir Kabir M, Rowlands JA.: Recent Advances in X-ray Photoconductors for Direct Conversion X-ray Image Detectors, Current Applied Physics, 6, 288-292, 2006   DOI   ScienceOn
9 Kasap SO, Rowlands JA.: Review X-ray Photoconductors and Stabilized a-Se for Direct Conversion Digital Flat-Panel X-ray Image Detectors, Journal of Materials Science: Materials in Electronics, 11, 179-198, 2000   DOI   ScienceOn
10 Schieber M, Hermon H, Street RA, at al.: Radiological X-ray Response of Polycrystalline Mercuric Iodide Detectors, Proc. of the SPIEMI, 3977, 48-55, 2000
11 Zentai G, Partain L, Pavlyuchkova R, at al.: Mercuric Iodide Medical Imagers for Low Exposure Radiography and Fluoroscopy, Proc. of the SPIE-MI, 5368, 200-300, 2004