• Title/Summary/Keyword: X-ray inspection

Search Result 214, Processing Time 0.029 seconds

A Study of x-ray tube voltage, tube current and dose rate depeding on temperature (온도 변화에 따른 X-선진단장치의 관전압, 관전류, 조사선량에 관한 연구)

  • Chon, Ki-Hwan;Hwang, Min-Seon;Choi, Myeon-Woong;Lee, Song-Yi;Kim, Min-Ji;Yang, Dong-Il;Lee, Gwi-Yeol
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.2
    • /
    • pp.264-272
    • /
    • 2011
  • This study was function experiment or inspection of diagnosis x-ray unit at the hospital. It's how many changes tube voltage, tube current, DOSE value through the experiment depending on temperature increasing. The study want to know whether which parameter shown out of range or not how about image quality and so on. Increasing tube current and DOSE were not only too many radiation to the patient and radiation workers and make bad images but also the tube should be damaged by heat. This study was recommended proper exposure at intervals of seconds because passed inspection, reduced radiations for patient and the tube used long term. This results in the hospital`s finances will be very helpful.

The Convergence Application Example of Non-destructive Inspection System (비파괴 검사 시스템의 융합 적용 사례)

  • Lee, Jeong-Ick
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.3
    • /
    • pp.191-197
    • /
    • 2017
  • This development is for non-destructive machine using X-Ray source about detecting outline faults of below middle size products. The differentiation is product of research and development unspecialized small and medium-sized products using X-Ray light sources can check real time if the surface of an external fault of radiation dose reference, within the leakage. The speed control is possible by software solution. In addition, we're working on possibly block doors for worker safety and equipment at the same time that inner drive can be identified in the image. These principles, as a key enabler of the current inspection system such as the container is small to medium-sized parts - a long way from utilization level is possible. This research will give rise to major effects for other various non-destructive market industries except car-industry. The most important fact is that this developed non-destructive machine is controlled below $0.2micro-S{\mu}v$.

A Study on Image Resolution Increase According to Sequential Apply Detector Motion Method and Non-Blind Deconvolution for Nondestructive Inspection (비파괴검사를 위한 검출기 이동 방법과 논블라인드 디컨볼루션 순차 적용에 따른 이미지 해상도 증가 연구)

  • Soh, KyoungJae;Kim, ByungSoo;Uhm, Wonyoung;Lee, Deahee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.609-617
    • /
    • 2020
  • Non-destructive inspection using X-rays is used as a method to check the inside of products. In order to accurately inspect, a X-ray image requires a higher spatial resolution. However, the reduction in pixel size of the X-ray detector, which determines the spatial resolution, is time-consuming and expensive. In this regard, a DMM has been proposed to obtain an improved spatial resolution using the same X-ray detector. However, this has a limitation that the motion blur phenomenon, which is a decrease in spatial resolution. In this paper, motion blur was removed by applying Non-Blind Deconvolution to the DMM image, and the increase in spatial resolution was confirmed. DMM and Non-Blind Deconvolution were sequentially applied to X-ray images, confirming 62 % MTF value by an additional 29 % over 33 % of DMM only. In addition, SSIM and PSNR were compared to confirm the similarity to the 1/2 pixel detector image through 0.68 and 33.21 dB, respectively.

Amendment of the Inspection Standard for Diagnostic Radiation Equipment Applying IEC 60601-1-3: Medical Electrical Equipment - Part 1-3: General Requirements for Basic Safety and Essential Performance - Collateral Standard: Radiation Protection in Diagnostic X-ray Equipment (KS C IEC60601-1-3: 의료용 전기기기-제1-3부: 기본 안전 및 필수 성능에 관한 일반 요구사항-보조표준: 진단용 X선 장치의 방사선 방어를 적용한 진단용 방사선 발생장치의 검사기준 개선안)

  • Park, Hye-Min;Kim, Jung-Min;Kim, Jung-Su;Kim, Seong-Ok;Choi, Young-Min
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.493-504
    • /
    • 2018
  • The diagnostic radiation equipment is managed in accordance with the "Rules for Safety Management of Diagnostic Radiation Equipment" enacted in 1995. The equipments should be inspected before use and every three years after use in accordance with the [Appendix 1] of the same rule. The inspection standard has been maintained without particular revision since enacted. But, over the past two decades new types of equipments have been manufactured and used. So, it is necessary to revise [Appendix 1] by making inspection items and inspection standards. In this study, we revised the classification system of equipments and reviewed international standards of IEC 60601 series, IEC 61223 series and AAPM TG 18 On-line Report No.03. And identified the problem of current inspection standards. Through this, we revised, deleted and added the inspection items and inspection standard of each equipment to meet the domestic circumstances. As a result of the study, we reorganized the classification system of equipment which are current classified as 5 classes into 22 classes as X-ray system etc. (7 classes), CT system etc. (5 classes) and Dental X-ray system etc. (10 classes). And then, we developed 70 inspection items for 6 types of equipments according to the reorganized classification system of equipments. The inspection items and inspection standards derived from this study have been proposed to the KCDC and will be applied to the revision of the Rule's [Appendix 1]. Therefore, we expect to be used as reference materials for domestic medical center, inspection institutions, and equipment manufacturing import companies.

X-ray Image Denoising Agorithm Using Bilateral Weight (양방향 가중치를 이용한 x선 영상 잡음 제거 알고리즘)

  • Shin, Soo-Yeon;Suh, Jae-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.1
    • /
    • pp.137-143
    • /
    • 2017
  • X-ray image is a widely used to medical examination, airport security and cargo inspection. However, X-ray images contain many visual noise, which interrupt image analysis. Consequently, it is primary importance to reduce noises of X-ray image. In this paper, we present a improved denoise technique for x-ray image using pixel value and range weights. First, we denoise a x-ray image using bilateral filter. Next, we detect a edge region of the original x-ray image. If a denoised pixel belongs to the edge region, we calculate weighting values of original x-ray image and denoised x-ray image in $3{\times}3$ neighboring pixels and compute the cost value to determine the boundary pixel value. Finally, the pixel value having minimum cost is determined as the pixel value of the denoised x-ray image. Simulation results show that the proposed algorithm achieves good performance in terns of PSNR comparison and subjective visual quality.

A Robust Crack Filter Based on Local Gray Level Variation and Multiscale Analysis for Automatic Crack Detection in X-ray Images

  • Peng, Shao-Hu;Nam, Hyun-Do
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.1035-1041
    • /
    • 2016
  • Internal cracks in products are invisible and can lead to fatal crashes or damage. Since X-rays can penetrate materials and be attenuated according to the material’s thickness and density, they have rapidly become the accepted technology for non-destructive inspection of internal cracks. This paper presents a robust crack filter based on local gray level variation and multiscale analysis for automatic detection of cracks in X-ray images. The proposed filter takes advantage of the image gray level and its local variations to detect cracks in the X-ray image. To overcome the problems of image noise and the non-uniform intensity of the X-ray image, a new method of estimating the local gray level variation is proposed in this paper. In order to detect various sizes of crack, this paper proposes using different neighboring distances to construct an image pyramid for multiscale analysis. By use of local gray level variation and multiscale analysis, the proposed crack filter is able to detect cracks of various sizes in X-ray images while contending with the problems of noise and non-uniform intensity. Experimental results show that the proposed crack filter outperforms the Gaussian model based crack filter and the LBP model based method in terms of detection accuracy, false detection ratio and processing speed.

Material Discrimination Using X-Ray and Neutron

  • Jaehyun Lee;Jinhyung Park;Jae Yeon Park;Moonsik Chae;Jungho Mun;Jong Hyun Jung
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.4
    • /
    • pp.167-174
    • /
    • 2023
  • Background: A nondestructive test is commonly used to inspect the surface defects and internal structure of an object without any physical damage. X-rays generated from an electron accelerator or a tube are one of the methods used for nondestructive testing. The high penetration of X-rays through materials with low atomic numbers makes it difficult to discriminate between these materials using X-ray imaging. The interaction characteristics of neutrons with materials can supplement the limitations of X-ray imaging in material discrimination. Materials and Methods: The radiation image acquisition process for air-cargo security inspection equipment using X-rays and neutrons was simulated using a GEometry ANd Tracking (Geant4) simulation toolkit. Radiation images of phantoms composed of 13 materials were obtained, and the R-value, representing the attenuation ratio of neutrons and gamma rays in a material, was calculated from these images. Results and Discussion: The R-values were calculated from the simulated X-ray and neutron images for each phantom and compared with those obtained in the experiments. The R-values obtained from the experiments were higher than those obtained from the simulations. The difference can be due to the following two causes. The first reason is that there are various facilities or equipment in the experimental environment that scatter neutrons, unlike the simulation. The other is the difference in the neutron signal processing. In the simulation, the neutron signal is the sum of the number of neutrons entering the detector. However, in the experiment, the neutron signal was obtained by superimposing the intensities of the neutron signals. Neutron detectors also detect gamma rays, and the neutron signal cannot be clearly distinguished in the process of separating the two types of radiation. Despite these differences, the two results showed similar trends and the viability of using simulation-based radiation images, particularly in the field of security screening. With further research, the simulation-based radiation images can replace ones from experiments and be used in the related fields. Conclusion: The Korea Atomic Energy Research Institute has developed air-cargo security inspection equipment using neutrons and X-rays. Using this equipment, radiation images and R-values for various materials were obtained. The equipment was reconstructed, and the R-values were obtained for 13 materials using the Geant4 simulation toolkit. The R-values calculated by experiment and simulation show similar trends. Therefore, we confirmed the feasibility of using the simulation-based radiation image.

A Volume Reconstruction Algorithm and a Coordinate Calibration of an X-ray Three Dimensional Imaging System

  • Roh, Young-Jun;Cho, Hyung-Suck;Jeon, Hyoung-Jo;Kim, Hyeong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.63.3-63
    • /
    • 2001
  • Inspection and shape measurement of three-dimensional objects are widely needed in industries for quality monitoring and control. In this paper, we propose a three dimensional volume reconstruction method, which is an iterative method and as uniform and simulated algebraic reconstruction technique (USART). In this method, two or more x-ray images projected from different views are needed, and also the geometry of the imaging system need to be a priori identified well. That is to say, the relative locations between the x-ray source, imaging plane and the object should be determined exactly by calibration. To achieve this, we propose a series of coordinate calibration methods of the x-ray imaging system using grid pattern images. Some experimental results of these calibrations is presented and discussed in detail ...

  • PDF

duoPIXTM X-ray Imaging Sensor Composing of Multiple Thin Film Transistors in a Pixel for Digital X-ray Detector (픽셀내 다수의 박막트랜지스터로 구성된 듀오픽스TM 엑스선 영상센서 제작)

  • Seung Ik, Jun;Bong Goo, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.969-974
    • /
    • 2022
  • In order to maximize dynamic range and to minimize image lag in digital X-ray imaging, diminishing residual parasitic capacitance in photodiode in pixels is critically necessary. These requirements are more specifically requested in dynamic X-ray imaging with high frame rate and low image lag for industrial 2D/3D automated X-ray inspection and medical CT imaging. This study proposes duoPIXTM X-ray imaging sensor for the first time that is composed of reset thin film transistor, readout thin film transistor and photodiode in a pixel. To verify duoPIXTM X-ray imaging sensor, designing duoPIXTM pixel and imaging sensor was executed first then X-ray imaging sensor with 105 ㎛ pixel pitch, 347 mm × 430 mm imaging area and 3300 × 4096 pixels (13.5M pixels) was fabricated and evaluated by using module tester and image viewer specifically for duoPIXTM imaging sensor.

Nondestructive Measurement of the Coating Thickness in the Simulated TRISO-Coated Fuel Particle Using Micro-Focus X-ray Radiography (마이크로포커스 X-선 투과 영상을 이용한 모의 TRISO 핵연료 입자 코팅 층 두께 비파괴 측정)

  • Kim, Woong-Ki;Lee, Young-Woo;Park, Ji-Yeon;Park, Jung-Byung;Ra, Sung-Woong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.2
    • /
    • pp.69-76
    • /
    • 2006
  • TRISO(tri-isotropic)-coated fuel particle technology is utilized owing to its higher stability at a high temperature and Its efficient retention capability for fission products In the HTGR(high temperature gas-reeled reactor). The typical spherical TRISO fuel panicle with a diameter of about 1mm is composed of a nuclear fuel kernel and outer coating layers. The outer coating layers consist of a buffer PyC(pyrolytic carbon) layer, Inner PyC(1-PyC) layer, SiC layer, and outer PyC(O-PyC) layer Most of the Inspection Items for the TRTSO-coated fuel particle depend on destructive methods. The coating thickness of the TRISO fuel particle can be nondestructively measured by the X-ray radiography without generating radioactive wastel. In this study, the coaling thickness for the simulated TRISO-coated fuel particle with $ZrO_2$ kernel Instead of $%UO_2$ kernel was measured by using micro-focus X-ray radiography with micro-focus X-ray generator and flat panel detector The radiographic image was also enhanced by image processing technique to acquire clear boundary lines between coating layers. The coaling thickness wat effectively measured by applying the micro-focus X-ray radiography The inspection process for the TRISO-coated fuel particles will be improved by the developed micro-focus X-ray radiography and digital image processing technology.