두부(頭部) X선촬영시(線撮影時) 산란선(散亂線)과 화질(畵質)에 관(關)한 검토(檢討) (A Study on the Image Quality and the Scattered Ray content in the Skull Radiography)

  • 허준;김창균;강홍석;이선숙;이인자
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제8권2호
    • /
    • pp.15-19
    • /
    • 1985
  • The seattered-ray have a bad effect to the image of x-ray film. Therefore, to obtain the better x-ray image, the most important point is to eliminate the scattered-ray, come from the patient, and the easiest method to eliminate the scattered-ray is to use a proper grid for tube voltages. Authors made an experiment on the scattered-ray contents and the image quality in skull radiography, and obtained the results as follows; 1. The scattered-ray content in skull radiography was 83%, but it could be reduced to 35%-50% by using grid. 2. The image contrast was most increased when the using grid ratio was 8:1. 3. The image quality was not influenced by the scattered-ray contents between 32% and 45%.

  • PDF

단일 비산란 그리드 및 다색광 x-선원 기반 위상대조 x-선 영상화 실험 연구 (Experimental Study for Phase-contrast X-ray Imaging Based on a Single Antiscatter Grid and a Polychromatic X-ray Source)

  • 박연옥;조효성;임현우;제의규;박철규;조희문;김규석;김건아;박소영
    • 한국의학물리학회지:의학물리
    • /
    • 제26권4호
    • /
    • pp.215-222
    • /
    • 2015
  • 본 연구에서는 단일 비산란 그리드 및 다색광 x-선원을 이용하여 위상대조 x-선 영상을 용이하게 구현할 수 있는 새로운 방법을 제안한다. 제안된 신기법의 개념 입증을 위해 집속형 선형 그리드(200 lines/inch 선 밀도), 마이크로 초점 x-선관(${\sim}5{\mu}m$ 초점크기), CMOS형 평판형 검출기($48{\mu}m$ 픽셀 크기)로 실험장치를 구성하였으며, 한 번의 x-선 촬영($90kV_p$, 0.1 mAs)으로 감약대조 x-선 영상과 향상된 가시성을 지진 산란 x-선 영상 및 차분 위상대조 x-선 영상을 Fourier변조복원 기법을 적용하여 성공적으로 분리 획득하였다. 더 나아가, 감약대조 x-선 영상과 산란 x-선 영상을 합성함으로써 일반 감약대조 x-선 영상에서는 명확하게 볼 수 없는 샘플의 미세 구조를 보다 선명하게 나타냄을 확인하였다. 본 논문에서 제안한 단일 비산란 그리드 기반 위상대조 x-선 영상화 기법은 실험 구성 및 절차가 단순하고 새로운 대조도에 기반한 산란 및 위상대조 x-선 영상을 동시에 제공하기 때문에 차세대 x-선 영상화 신기법으로 다양한 응용분야에서 용이하게 적용될 수 있을 것으로 전망한다.

X선 3차원 영상 시스템에서의 영상 왜곡 및 영상 좌표계 보정 (Correction of Image Distortion and Coordinate Calibration of the x-ray three dimensional imaging system)

  • 노영준;김재완;조형석;전형조;김형철;주효남
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.413-413
    • /
    • 2000
  • In this paper, we propose a series of calibrations f3r the x-ray three dimensional imaging system. In the developed x-ray system, a three dimensional inner and outer shape of an object can be reconstructed out of two dimensional transmitted x-ray image set, which are acquired by projecting x-ray to the object from different views. To achieve this, a reconstruction algorithm which estimates and updates the three dimensional volume from x-ray images is developed. The algorithm is named as uniform and simultaneous algebraic reconstruction technique(USART) which is an iterative method estimating a 3D volume based on its projected images. In this method, it is assumed that the imaging conditions that are the relative positions between the x-ray sources, object and the image planes are blown. Practically it is not easy to know the three dimensional coordinate of the components of the system, since the x-ray is not visible and the image distortions are present due to the optical components in the system. In this paper, methods of correcting image distortions are present firstly. Then the coordinates of the x-ray systems are calibrated from the x-ray images of the grid pattern. Some experimental results on these calibrations are present and discussed.

  • PDF

가상 그리드 소프트웨어를 위한 X-ray 영상 개선 기법 (An X-ray Image Enhancement Technique for Virtual Grid Software)

  • 문혁은;정예닮;서지수;김호준
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2017년도 추계학술발표대회
    • /
    • pp.915-916
    • /
    • 2017
  • 본 연구에서는 X-ray 영상에서 산란선의 영향을 보정하는 소프트웨어 기법을 제시한다. 영상에서 픽셀값과 에지 요소가 연관된 에너지함수를 정의하고 이를 최적화 하는 방법을 통하여 X-ray 영상을 개선한다. 영상개선 과정에서 추출하는 에지정보의 신뢰성은 응용의 특성과 연관하여 성능에 민감한 영향을 준다. 이에 본 연구에서는 기존의 에지 추출 기법을 통합한 에지 정보 개선 기법을 적용하였으며 실제 X-ray 영상을 사용한 실험결과로부터 제안된 이론의 타당성을 고찰하였다. 이는 X-ray를 사용한 의료진단에서 산란선 보정을 위한 하드웨어의 기능을 대치할 수 있는 방법으로서 의미를 갖는다.

X선 진단장치의 고압정류방식이 대조도 향상에 미치는 영향 (Effects of Contrast Improvement on High Voltage Rectification Type of X-ray Diagnostic Apparatus)

  • 이후민;윤준;김현주
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권3호
    • /
    • pp.187-193
    • /
    • 2014
  • 본 연구는 X선 진단장치의 고압정류방식이 그리드 성능을 측정하는 선택도(selectivity)와 대조도 향상능력(contrast improvement ability : K factor)에 미치는 영향을 분석하고자 산란선 함유율을 측정하였다. 정류방식이 서로 다른 X선발생장치를 대상으로 각 장치의 관전압과, 관전류량을 측정하여 출력선량의 정확도를 측정 및 교정한 후 각 장치별 노출조건을 동일하게 설정하고 형광량계를 이용하여 아크릴을 투과한 X선의 산란선 함유율을 측정하였다. Grid 미사용 시 피사체를 투과한 X선의 산란선 함유율 측정 결과는 단상정류방식장치에서 가장 낮은 함유율(34.158%)이 측정되었고, 인버터 정류방식(37.043%)과 삼상24피크 정류방식(37.447%)은 산란선 함유율이 증가하였다. 각 장치들의 산란선 함유율 차이는 최저 0.404%에서 최고 3.289%의 차이를 보였다. 8:1 Gird 사용 시 피사체를 투과한 X선의 산란선 함유율을 측정한 결과는 단상정류방식장치에서 가장 낮은 함유율(18.258%)로 측정되었고, 인버터정류방식(25.502%)과 삼상24피크정류방식에서 산란선 함유율(24.217%)이 증가하였다. 그리드 선택도에 따라 단상정류방식과 정전압(인버터와 삼상24피크)정류방식에서 산란선함유율의 차이는 최저 1.285%에서 최고 7.244%의 차이를 보였다. 통계분석 결과 단상정류방식 및 정전압정류방식에서 대조도 향상계수(K factor)에서도 유의한 차이를 보였다. 결론적으로 그리드 선택도와 대조도 향상계수는 정전압정류방식보다는 단상전파방식에서 모두 증가하여 그리드의 사용으로 선택도 향상과 대조도의 개선효과가 증가함을 알 수 있었다.

X선촬영에 있어서 관전압과 피사체가 선질 및 선량에 미치는 영향의 실험 (Influence of X-ray Tube Voltage and Object on X-ray Quality and Dose)

  • 허준;김창균;강홍석;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제7권1호
    • /
    • pp.41-46
    • /
    • 1984
  • Authors investigated an influence of x-ray tube voltage on x-ray quality and dose with using objects of various thickness, and obtained the results as follows: 1. Radiographic effects were influenced by tube voltages and objects. 2. Dose decrement rates hade more influence upon primary-rays than total x-rays at lower tube voltages. 3. The quality of transmitted x-rays was affected by tube voltages and thickness of objects. 4. Scattered-ray contents were proportional to tube voltages with using grid.

  • PDF

Contribution of Scattered X Rays to Signal Imaging with Anti-scatter Grids

  • Maeda, Koji;Arimura, Hidetaka;Morikawa, Kaoru;Kanamori, Hitoshi;Matsumoto, Masao
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.404-406
    • /
    • 2002
  • We have investigated the contribution of the scattered x rays to the signal imaging in the radiographs acquired with anti-scatter grids of several grid ratios by separating the line spread functions (LSFs) derived from the signal edge image into the primary and the scatter components. By using a 1.0-mm lead plate in the scattering material, the blurred signal edge images were acquired by use of an imaging plate at a tube voltage of 80 kV with the anti-scatter grids of grid ratios for 5:1, 6:1, 8:1, 10:1 and 12:1. The edge profiles of the signal images were scanned and those in relative exposure were differentiated to obtain the LSFs. To investigate the contribution of the scattered x rays to the signal imaging, we proposed a method for separating the LSFs derived from the signal images into the primary and the scatter components, where the scatter component was approximated with exponential function. Our basic approach is to separate the area of the LSFs by ratios of the scattered x-ray exposure to the primary x-ray exposure, which were obtained for the grid ratios by use of a lead disk method. The LSFs and the two components were Fourier transformed to obtain the modulation transfer functions (MTFs) and their two components. As the result, we found that, by using the anti-scatter grids, the scattered x rays were reduced, but the shape of the LSFs of the scatter component hardly changed. The contributions of the scatter component to the MTFs were not negligible (more than 10 %) for spatial frequencies lower than about 1.0 mm$\^$-l/ and that was greater as the grid ratio decreasing. On the other hand, for higher frequencies, the primary component was dominant compared with the scatter component.

  • PDF

소아 흉부검사 시 격자 사용에 따른 영상 화질 평가 (Evaluation of Image Quality When Using Grid During Child Chest X-Ray Examination)

  • 정성훈;한범희;정홍량
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권3호
    • /
    • pp.371-376
    • /
    • 2017
  • 소아의 경우 방사선의 감수성이 성인에 비하여 높고, 잠재적 피폭으로 인한 장해가 발생할 수 있으므로 피폭선량에 대해 관리가 요구된다. 이에 본 연구는 소아 흉부검사 시 산란선을 제거시켜주지만 피폭선량을 증가시키는 격자(Grid)의 사용 유, 무에 따른 영상과 거리와 조건의 변화에 따른 영상을 분석하여 소아 흉부검사에서 적정한 검사조건을 제시하고자 하였다. 연구방법은 Grid를 부착한 상태에서 100 cm, 180 cm에서 측정하였으며, kVp를 70. 90. 110으로 변화하여 측정하였다. 또한 Grid를 미부착한 상태에서 100 cm, 180 cm을 고정 시키고, 선량을 6, 8, 10 mAs로 변화시켜 측정하였으며, 측정항목은 신호 대 잡음비, 대조도 대 잡음비, J.J Vucich를 측정하였다. kVp를 고정시켜 측정한 결과 초점-이미지 수용체간 거리가 100 cm일 때 신호 대 잡음비, 대조도 대 잡음비, J.J Vucich가 모두 높게 나타났다. 또한, 선량(mAs)을 변화시켜 측정한 결과 신호 대 잡음비, 대조도 대 잡음비, J.J Vucich에서 초점-이미지 수용체 간 거리 100 cm에서 높게 나타났다. 현재 국내에서 흉부검사는 일반적으로 180 cm으로 시행하고 있지만 본 연구결과에서는 소아의 흉부 검사 시 초점-이미지수용체간 거리가 100 cm일 때 영상평가에서 화질이 높게 평가되었다.

산란선 제거를 위한 신개념 간접 평판형 검출기의 임상적용을 위한 최적 구조 : 입사 X선 각도에 따른 성능평가 (An Optimal Structure of a Novel Flat Panel Detector to Reduce Scatter Radiation for Clinical Usage: Performance Evaluation with Various Angle of Incident X-ray)

  • 윤용수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권4호
    • /
    • pp.533-542
    • /
    • 2017
  • 진단용 X선 영상에서 산란선은 화질을 열화시키는 주요한 원인이다. X선 장치는 필름/스크린을 사용한 아날로그 시스템부터 Imaging plate (IP) 및 평판 검출기(Flat panel detector; FPD)를 사용한 디지털 시스템으로 바뀌어 가고 있다. 그러나 산란 X선 제거를 위한 Grid는 아날로그 시대에 사용됐던 구조부터 큰 변화가 없다. 본 논문에서는 선행연구에서 고안된 산란선 제거율을 향상시키기 위한 간접변환형 평판검출기의 새로운 구조를 다양한 입사 X선을 사용하는 임상현장에서의 활용 가능성을 검토했다. 일반적으로 FPD는 3개의 층으로 구성되어 있다. 신호를 검출하는 화소와 화소 사이에는 전압을 거는 voltage line이나 데이터를 전달하는 data line과 같은 X선 불감영역이 존재한다. 선행연구에서는 이 불감영역에 정확히 맞추어 방사선 불 투과성의 납을 그물 모양으로 substrate layer에 삽입함으로서 검출기 자체가 산란선 제거 효과가 있도록 설계하였다. 새로운 구조의 임상 유용성을 평가하기 위해, 삽입된 그물 모양의 납을 입사 X선에 대해 가로, 세로성분으로 나누어 각각의 성능을 확인하였으며, 동시에 납의 높이를 변화시켜 납 높이가 성능에 미치는 영향을 영상 대조도와 grid 노출 인자를 통해 검토했다. 검출기면에 대해 대각선으로 입사한 X선($0^{\circ}$, $15^{\circ}$, $30^{\circ}$)에 대해서, 입사 X선에 대해 평행한 가로성분이 세로 성분에 비해 높은 영상 대조도와 낮은 그리드 노출 인자를 나타냈으며, 세로성분의 납 높이가 높을수록 본 연구에서 고안한 검출기에 악영향을 미치는 것을 확인했다. 그러므로 본 연구에서 고안한 새로운 FPD 시스템은 FPD의 구조를 방사선검사 조건과 목적에 맞추어 최적화함으로써 임상 의료현장에서의 사용 가능성이 확인되었다.

엉덩관절 정면 검사 시 환자 피폭 감소 (Reducing Radiation Exposure During X-ray Imaging of Both Hip AP)

  • 신성규;이효영
    • 한국방사선학회논문지
    • /
    • 제10권5호
    • /
    • pp.313-320
    • /
    • 2016
  • 본 연구는 엉덩관절 정면 검사 시 격자 제거와 관전압, Cu Filter의 조합을 이용하여 환자의 피폭을 감소하고자 시행하였다. 엉덩관절 정면 검사법을 대상으로 격자의 사용과 제거 상태에 따라 각각 관전압을 60~90 kV로 변화시키고 Cu Filter를 0.1~0.3 mm로 추가시켜 입사선량, 유효선량을 측정하고 영상의 진단적 가치를 평가하였다. 격자를 사용하고 관전압 60 kV, none filter에서 입사선량은 4.77 mGy로 가장 높은 측정치를 나타냈고 격자를 사용하지 않고 90 kV, 0.3 mm Cu filter 조건에서의 입사선량은 0.14 mGy로 가장 낮았으며 약 34배의 차이를 나타냈다. ICRP Pub. 60을 기준으로 70 kV에서 고환, 난소의 유효선량은 격자를 사용 했을 경우 0.255 mSv, 격자를 제거하였을 경우에는 0.049 mSv로 약 5.2배의 차이를 나타냈다. ICRP Pub. 103을 기준으로 70 kV에서 고환, 난소의 유효선량은 격자를 사용했을 경우 0.090 mSv 격자를 제거하였을 경우에는 0.020 mSv로 약 4.5배의 차이를 나타냈다. 격자를 사용하였을 경우의 노광지수는 671~782, 격자를 제거하였을 경우에는 513~606 사이로 적정 노출조건이었으며 영상평가결과 모두 진단적 가치가 있는 영상으로 나타났다. 따라서 엉덩관절 정면 검사 시 격자를 제거하고 관전압을 높이고 Cu Filter를 추가시켜 촬영하면 환자의 피폭을 줄일 수 있을 것이다.