Abstract
This research has been conducted to investigate the method of reducing patients' radiation exposure during X-ray imaging of Both Hip Ap examination by removing the grid. When using the grid with 60 kV and a non-filter, the Entrance Surface Dose was 4.77 mGy, and the result was highest and 34 times higher than the lowest measurement when removing the grid with 90 kV, and 0.3 mmCu filter. Based on the ICRP Pub. 60 at the level of 70 kV, the Effective Dose of testis and ovary was 0.255 mSv when using the grid, and that result was approximately 5.2 times higher than the 0.049 mSv when removing the grid. Based on the ICRP Pub. 103 at the level of 70 kV, the Effective Dose of testis and ovary was 0.090 mSv when using the grid, and that result was approximately 4.5 times higher than the 0.020 mSv when removing the grid. When using the grid, the range of Exposure Index was 671 to 782, and when removing the grid, the range of Exposure Index was 513 to 606, and both results were at optimal exposure conditions and valid diagnostic imaging after evaluations. Therefore, removing the grid during X-ray imaging of Both Hip Ap will help reduce patients radiation exposure.
Keywords
Both Hip Ap; Grid; Entrance Surface Dose; Effective Dose;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Ministry of Health and Welfare, Ministry of Food and Drug Safety, Korean Society of Radiology, The Korean Radiological Technologists Association, "Diagnostic Reference Level Guide-Line of Radiology Exam-Skull, Chest, Abdomen, Pelvis, Cervical-Spine, Thoracic-Spine, Lumbar-Spine, Radiation Safety," 30, 2012.
2 ICRP, "1990 Recommendations of the International Commission on Radiological Protection. Publication 60," Annals of the ICRP, Pergamon Press, Oxford, pp. 21, 1991.
3 ICRP, "Protection of the Patient in Diagnostic Radiology, Publication 34," Annals of the ICRP, Pergamon Press, Oxford," pp. 9, 1982.
4 ICRP, "Protection of the Patient in Diagnostic Radiology, Publication 34," Annals of of the ICRP, Pergam on Press, Oxford, pp. 137, 2007.
5 D. M. Kweon, S. S. Kim, Y. G. Kim, Analog & Digital, PACS, Daihakseolim, 2011.
6 K. L Bontrager, J. P. Lampignano, TEXTBOOK of Radiographic Positioning and Related Anatomy, Sixth Edition, Jungdam, 2009.
7 K. H. Lee, C. H. Lee, G. H. Jin, "Stationary and Moving Computed Radiography Grids : Comparative Observer's Perception," Journal of the Korean Society of Radiology, Vol. 9, No. 7, 2015.
8 Radiation Control Textbook Compilation Committee, Radiation Protection & Safety, Chung-Ku, 2014.
9 I. H. Go, Y. L. Kim, Y. J. Kim, T. H Kim, H. S. Kim, Y. S. Park, J. B. Park, C. W. Park, T. J Ji, Radiation Biology, Komoonsa, 2013.
10 Y. H. Kim "Methods for Measurement of Entrance Surface Dose and Roles of Radiation technologist", Journal of radiological science and technology, Vol. 28, No. 3, pp. 173-191, 2005.
11 http://www.mfds.go.kr/
12 http://www.wikiradiography.com/page/Exposure+Index/
13 IAEA, "International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources, Safety Series," 115, 1996.
14 Deutschalnd Bundesamt fur Strahlenschutz, "Diagnostic reference level that apply to radioactive examination and nuclear medicine examination," 2003.
15 NRPB, "Doses to Patients from Medical X-ray Examinations in the UK-2000 Review," 2002.
16 HPA, "Dose to Patient from Radiographic and Fluoroscopic X-ray imaging Procedures in the UK-2005 Review," 2007.
17 I. J. Lee, Y. B. Yeo, T. S. Lee, "Entrance Skin Dose and Image Quality Evaluation According to Use Grid Radiography for the Extremity in FPD System," Journal of radiological science and technology, Vol. 33, No. 4, pp. 341-348, 2010.
18 S. H. Choi, "A Study on Dose and Image Quality in DR System Evaluation According to Use of the Grid," Department of Radiological Science, The Graduate School of Health Promotion Hanseo University, 2012.