• Title/Summary/Keyword: X-ray 시스템

Search Result 499, Processing Time 0.027 seconds

A Multi Resolution Based Guided Filter Using Fuzzy Logic for X-Ray Medical Images (방사선 의료영상 잡음제거를 위한 퍼지논리 활용 다해상도 기반 유도필터)

  • Ko, Seung-Hyun;Pant, Suresh Raj;Lee, Joonwhoan
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.4
    • /
    • pp.372-378
    • /
    • 2014
  • Noise in biomedical X-ray image degrades the quality so that it might causes to decrease the accuracy of diagnosis. Especially the noise reduction techniques is quite essential for low-dose biomedical X-ray images obtained from low radiation power in order to protect patients, because their noise level is usually high to well discriminate objects. This paper proposes an efficient method to remove the noise in low-dose X-ray images while preserving the edges with diverse resolutions. In the proposed method, a noisy image is at first decomposed into several images with different resolutions in pyramidal representation, then the stable map of edge confidence is obtained from each of analyzed image using a fuzzy logic-based edge detector. This map is used to adaptively determine the parameter for guided filters, which eliminate the noise while preserving edges in the corresponding image. The filtered images in the pyramid are extended and synthesized into a resulted image using interpolation technique. The superiority of proposed method compared to the median, bilateral, and guided filters has been experimentally shown in terms of noise removal and edge preserving properties.

Synthesis of Single-Crystalline InSb Nanowires Using CVD Method and Study of Growth Mechanism in Open and Close System (CVD 방법을 이용한 단결정 InSb 나노와이어의 성장과 Open/Close 시스템에서의 반응 메커니즘 연구)

  • Kang, Eun Ji;Park, Yi-Seul;Lee, Jin Seok
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.6
    • /
    • pp.306-312
    • /
    • 2013
  • Single-crystalline InSb nanowire was synthesized on $SiO_2$ wafer via vapor-liquid-solid (VLS) mechanism using chemical vapor deposition method. According to the source container system (open or close) which contain InSb powder and $SiO_2$ wafer, the single-crystalline InSb nanowires have different growth mechanisms. Structural characterization of the InSb nanowires was examined by scanning electron microscope (SEM). Composition of the nanowires was investigated using x-ray diffraction (XRD) and energy dispersive x-ray spectroscopy (EDS). This study demonstrates that length and diameter of the InSb nanowires are long and thick using open-boat system by VLS and additional vapor-solid (VS) mechanisms, because open-boat system can carry a large amount of vapor-phase InSb precursor than close-boat system.

Numerical Analysis on the compressive behavior of closed-cell Al foam (닫힌 셀 구조 Al 발포 재료의 압축 거동에 대한 수치해석)

  • Jeon, In-Su
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1663-1666
    • /
    • 2007
  • The finite element method is applied to analyze the deformation mechanisms in the closed-cell Al foam under the compression. The modeling of the real cellular structure proceeds with the concept of the reverse engineering. First of all, the small, $10{\times}\;10{\times}\;10mm^3$ sized specimens of the closed-cell Al foam are prepared. The micro focus X-ray CTsystem of SHIMADZU Corp. is used to scan the full structures of the specimens. The scanned structures are converted to the geometric surfaces and solids through the software for 3-D scan data processing, RapidFormTMof INUS Tech. Inc. Then the solid meshes are directly generated on the converted geometric solids for the finite element analysis. The large elastic-plastic deformation and 3-D contact problems for the Al cellular material are considered. The clear and successful analysis for the deformation mechanisms in the closed-cell Al foam is carried out through the comparison of the numerical results in this research with the referred experimental ones.

  • PDF

Numerical analysis of fracture mechanisms for porous calcium phosphate (다공성 칼슘포스파이트에 대한 파괴분석)

  • Park, Jin-Hong;Bae, Ji-Yong;Shin, Jae-Bum;Jeon, In-Su
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1301-1302
    • /
    • 2008
  • In this study, the fracture strength for fracture mechanism porous calcium phosphate made from sintered with ${\beta}$-tricalcium phosphate obtained by wet precipitation procedure is analyzed using finite element method and experiment measurement. First, three $3{\times}3{\times}3mm^3$ and $5{\times}5{\times}5mm^3$ specimens are prepared and tomographic images of one $5{\times}5{\times}5mm^3$ specimen are obtained by micro focus X-ray CT. The compression tests using the specimens are carried out to measure the elastic modulus and fracture strength to analyze the fracture mechanism of porous calcium phosphate specimen. The tomographic images are reconstructed by 3D reconstruction program. The finite elements are directly built up in the reconstructed specimen. The numerical simulation for the compression tests is performed using the element. The mechanism of calcium phosphate of simulation are obtained by the compression tests using there cylindric specimen of height 19.5 mm and diameter 10 mm. From the results, the applicability of porous calcium phosphate is evaluated to care fracture and vacant bone of a patient as the reinforcement material.

  • PDF

A Design of Onboard Telemetry System for the Scientific Sounding Rocket KSR-420S (과학관측 로케트 KSR-420S의 탑재용 원격측정 시스템설계)

  • 이수진;이재득;조광래;류장수
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.5 no.2
    • /
    • pp.3-9
    • /
    • 1994
  • Telemetry system which is mounted on the scientific sounding rocket KSR-420S transmits the informations about the performance of flighting rocket - distribution of the strain and temperature, accleration, pressure, velocity,attitude etc. - , the status of onboard circuit operating and measured data for scientific research such as ozone, ionosphere, x-ray etc. In this paper, PCM / FM telemetry system which was mounted on the KSR-420S is described.

  • PDF

Analysis of the information capacity of digital radiograpy system (디지탈 X-선 촬영 시스템의 정보용량 분석)

  • 김종효;민병구;박광석;한만청
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.564-569
    • /
    • 1990
  • In this paper, the information capacity, the Integrate performance measure of digital radiography system has been quantitatively analyzed. The effect of various factors affecting the information capacity of the digital radiography system in multi-stage detection processes has been considered and analyzed In detail. The results show that the more Information capacity can be obtained with the smaller detector cell area, despite of the decreasing signal to noise ratio due to the reduced number of X-ray photons per detector cell. And also has been Indicated that the Increase of the information capacity may be severely lost by the addition of electric noise in final read-out stage.

  • PDF

구동 팬톰 시스템을 통한 내부 장기 움직임의 선량 평가

  • Kim, Jae-Gyun;Kim, Yun-Jong;Lee, Dong-Han;Lee, Dong-Hun;Kim, Mi-Suk;Jo, Cheol-Gu;Ryu, Seong-Ryeol;Yang, Gwang-Mo;Yu, Hyeong-Jun;Ji, Yeong-Hun
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.64-67
    • /
    • 2005
  • 본 연구의 목적은 호흡 운동에 영향을 받는 내부 장기의 움직임을 정량적으로 분석하고, 그 결과를 토대로 움직이는 내부 장기의 선량 분포를 측정하고 평가하는 것이다. 그리고 이전에 보고된 논문에서 개발된 움직임 감소 장치의 사용 유무에 따른 내부 장기의 선량 분포 또한 분석하는 것이다. 이를 위하여 1차원적으로 움직이는 구동 팬톰 시스템을 개발하였고, 6MV X-ray에서 Kodak X-omat V 필름을 사용하여 움직이는 내부 장기의 선량분포를 실험적으로 측정하였다. 이 결과로부터 호흡 운동으로 인한 움직이는 내부 장기 및 종양에 조사되는 선량의 부정확도를 평가할 수 있었고, 움직임 감소 장치를 사용했을 때 선량의 부정확도가 감소함을 확인할 수 있었다.

  • PDF

Spectroscopic Characterization of 400℃ Annealed ZnxCd1-xS Thin Films (400℃ 열처리한 삼원화합물 ZnxCd1-xS 박막의 분광학적 특성 연구)

  • Kang, Kwang-Yong;Lee, Seung-Hwan;Lee, Nam-Kwon;Lee, Jeong-Ju;Yu, Yun-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.1
    • /
    • pp.101-112
    • /
    • 2015
  • II~VI compound semiconductors, $Zn_xCd_{1-x}S$ thin films have been synthesized onto indium-tin-oxide(ITO) coated glass substrates using thermal evaporation technique. The composition ratio x($0{\leq}x{\leq}1$) was varied to fabricate different kinds of $Zn_xCd_{1-x}S$ thin films including CdS(x=0) and ZnS(x=1) thin films. Then, the deposited thin films were thermally annealed at $400^{\circ}C$ to enhance their crystallinity. The chemical composition and electronic structure of films were investigated by using X-ray photoelectron spectroscopy(XPS). The optical energy gaps of the samples were determined by ultra violet-visible-near infrared(UV-Vis-NIR) spectroscopy and were found to vary in the range of 2.44 to 3.98 eV when x changes from 0 to 1. Finally, we measured the THz characteristics of the $Zn_xCd_{1-x}S$ thin films using THz-TDS(time domain spectroscopy) system to identify the capability for electronic and optical devices in THz region.

Comparison of Image Quality of the Amorphous Silicon DR System and the Film-screen Systems (비정질 실리콘 디지털 방사선 촬영기와 X-ray film과의 영상질 비교 평가)

  • Youn, Je-Woong;Lee, Hyoung-Koo;Suh, Tae-Suk;Choe, Bo-Young;Shin, Kyung-Sub;Mun, In-K.;Kim, Hong-Kwon;Han, Yong-Woo;Nam, Seung-Bae
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.3
    • /
    • pp.161-170
    • /
    • 1999
  • System performances in terms of image quality between an amorphous silicon DR system and a conventional film-screen system were evaluated. Various aspects of image quality MTF (modulation transfer function), NPS (noise power spectrum), SNR(signal-to-noise ratio) and contrast were measured and calculated. The MTF of the DR system was comparable to the film-screen systems. The noise was mainly dominated by the quantum mottle in both systems and the electronic noise was found in the DR system. The contrast of the DR system was better than the film-screen systems by virtue of high sensitivity and image processing. Compared to the film-screen systems in general radiography, the DR system had similar resolution and showed better contrast with the same exposure condition after contrast manipulation. The results of this study provide some useful information about the performance of the DR system in connection with medical applications.

  • PDF

A Design and Implementation of MINI-PACS Employing the DICOM Converter on Web Environment (웹 상에서 DICOM 변환기를 이용한 MINI-PACS 설계 및 구현)

  • Ji, Youn-Sang;Rhee, Kang-Hyeon;Chung, Il-Yong;Lee, Sung-Joo
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.38 no.4
    • /
    • pp.39-49
    • /
    • 2001
  • Application of information system to hospital would bring innovative improvement on efficiency of business management and provide high quality services toward patients as well as the retrenchment of operating funds. PACS(Picture Archiving and Communication System) including X-ray film that manages the medical image information effectively, has drawn considerable attention to essential structural elements to the sophisticated information system for hospital. PACS system should be connected to the network after making a form of standard medical image file from different style of image information obtained from various medical instruments. In this paper, to solve this problem, we construct Mini-PACS that converts the form of Non-DICOM file to the form of standard file by designing the DICOM converter. This system is designed to be managed under Web environment. Comparing with the existed Mini-PACSs, consisting of the client and server module, our system is designed and implemented with integration of these functions in order to be strongly combine strongly between system.

  • PDF