• Title/Summary/Keyword: X-factor

Search Result 2,440, Processing Time 0.038 seconds

Sintering and Microwave Dielectric Properties of Zn2-2xSi1+xO4 Ceramics (Zn2-2xSi1+xO4 세라믹스의 소결 및 마이크로파 유전 특성)

  • Yoon, Sang-Ok;Kim, Yun-Han;Kim, So-Jung;Jo, So-Ra;Kim, Shin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.7
    • /
    • pp.428-432
    • /
    • 2015
  • Sintering and microwave dielectric properties of $Zn_{2-2x}Si_{1+x}O_4$ (x=0~0.10) ceramics were investigated. The secondary phase of ZnO was observed in the specimen for x=0 whereas $SiO_2$ was detected in that for x=0.05. The composition of $Zn_2SiO_4$ might be close to x=0.02, i.e., $Zn_{1.96}Si_{1.02}O_4$; the ratio of Zn/Si is 1.922. The insufficient grain growth was observed in the specimen of x=0. For the specimens of $x{\geq}0.05$, the grain growth sufficiently occurred through the liquid phase sintering. The value of quality factor of all specimens was dependent on the x value, i.e., the ratio of Zn/Si, whereas that of dielectric constant was independent. Relative density, dielectric constant, and quality factor ($Q{\times}f$) of the specimen for x=0.05, i.e., $Zn_{1.9}Si_{1.05}O_4$, sintered at $1,400^{\circ}C$ were 96.5%, 6.43, and 115,166 GHz, respectively.

Out-of-Plane Effective Length Factor of X-Bracing System (X-브레이싱의 면외 유효 좌굴길이 계수)

  • Moon, Ji Ho;Yoon, Ki Yong;Lee, Hak Eun
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.1
    • /
    • pp.129-137
    • /
    • 2007
  • In this study, the elastic out-of-plane buckling load and the effective length factor of X-bracing systems were studied. Points of the intersection of diagonals were modeled as a rigid connection or a pinned connection depending on the connection method of diagonals. The boundary condition of the intersection influences the buckling load of X-bracing systems. For each boundary condition of the intersection, effective out-of-plane length factors of X-bracing systems were derived as a function of the length ratio of tension and compression diagonals $L_P$/$L_T$, the applied force ratio of tension and compression diagonals T/P, and the Euler buckling load ratio of tension and compression diagonals $P_{ET}$/$P_{EP}$. The proposed effective out-of-plane length factors of X-bracing systems were compared with the results of previous researchers and those of the finite element analysis and their properties were verified. Finally, the effects of the boundary condition of the intersection on the out-of-plane buckling load of X-bracing systems were investigated.

Research on Optimizing Luminosity Factor Through Color Filter $Y_{1-X}G_X$, $Y_{1-X}P_X$ ($Y_{1-X}G_X$, $Y_{1-X}P_X$ 칼라필터를 통한 시감도 최적화 연구)

  • Kim, YongGeun;Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.47-56
    • /
    • 2009
  • Purpose: To find optimized luminosity factor of color from light transmission filter. Methods: To make $Y_{1-x}G_{x}$, $Y_{1-x}P_{x}$ by using CR-39 compound within dipping method, mixing up Y(Yellow), G(green) and P(pink) for optimize eye sensitivity. Modeling for relative luminous efficiency(relative sensitivity) curves in Luminose transmission, it could be resolved by Multiplying sensitivity of eye within transmission rate of Lens ($P_f({\lambda}=T({\lambda}){\cdot}P({\lambda}).)$.). To evaluate Wavelength between 400~700 nm, relative luminous efficiency curve in Area and Height value is being used. Results: In color filter of $Y_{1-x}G_{x}$ position of x equals to 0.04, 0.1, 0.08, 0.12, 0.14, 0.5 at ${\beta}=S_1/S_0{\cdot}100$ each consist value of 76.1, 77.9, 80.7, 81.6, 80.2, 18.6 In color filter of $Y_{1-x}P_{x}$ position of x equals to 1.00, 0.2, 0.6, 0.8 at ${\beta}=S_1/S_0{\cdot}100$ each consist value of 74.3, 74.0, 70.5, 33.0 The result from experiment $Y_{1-x}P_{x}$ value less than $Y_{1-x}G_{x}$, from evaluating luminous efficiency curve and test was successfully optimized. Conclusions: Optimized relative luminous efficiency curve result have value of X=0.12-0.14 at $Y_{1-x}G_{x}$.

  • PDF

A Study on the X-ray Diffraction Analysis and the Fatigue Crack Growth Behavior for the Gas Piping Material (가스배관재의 X-선 회절분석과 피로균열거동에 관한 연구)

  • 임만배;윤한기;박원조
    • Journal of Ocean Engineering and Technology
    • /
    • v.16 no.3
    • /
    • pp.54-58
    • /
    • 2002
  • This study investigates a relationship between fracture mechanics parameters (Stress Intensity Factor Range: ΔK, Maximum Stress Intensity Factor; Kmax) and X-ray parameters (residual stress:$\sigma$r half-value breadth: B) for SG365 steel at elevated temperature up to 30$0^{\circ}C$. The fatigue crack propagation test were carried out and X-ray diffraction technique according to the direction of crack length was applied to fatigue fractured surface. The residual stress on the fracture surface was found to increase at low ΔK region, to reach a maximum value at a certain value of Kmax or ΔK and then to decrease. Residual stress was independent of stress ratio by arrangement of ΔK and half value breadth were independent of the arrangement of Kmax. The equation of $\sigma$r-ΔK was established by the experimental data. therefore, fracture mechanics parameters could be estimated by the measurement of X-ray parameters.

A Study on Measurement of Output Dose in X-ray Unit (X-선장치에서 출력선량 측정에 관한 연구)

  • Kim, Jong Eon;Lee, Sang Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.289-294
    • /
    • 2020
  • In order to control the quality of X-ray images and patient exposure, it is necessary to document the output dose(air absorption dose(mGy)) output from the X-ray unit from the measurement. The purpose of this study is to find an equation that can calculate the output dose from the measurement of the output dose and output factor(Of) of the X-ray Unit. The output dose and output factors of the X-beam irradiated from the X-ray unit were measured using an XR multi-detector. The output dose calculation formula was obtained by fitting the measured output dose divided by the tube current-exposure time product(mAs) and the set tube voltage with Allometric1. The final output dose calculation formula was obtained by multiplying this formula with the output factor. It is considered that the obtained final output dose calculation formula will be useful for all tube voltages, tube currents, exposure times, field sizes, and distances.

Validation of the Korean Version of the Posttraumatic Growth Inventory-Expanded (외상 후 성장 척도 확장판(The Posttraumatic Growth Inventory-Expanded: PTGI-X)의 한국판 타당화 연구)

  • Kim, Si Hyeong;Lim, Sujeong;Shin, Jiyoung;Lee, Deok Hee;Lee, Dong Hun
    • Korean Journal of Culture and Social Issue
    • /
    • v.26 no.3
    • /
    • pp.195-220
    • /
    • 2020
  • The purpose of this study was to validate the Korean version of the post-traumatic growth inventory-expanded(K-PTGI-X), which has been widely used to assess posttraumatic growth. The PTGI-X is a measure of the addition of the items to measure the existential growth as the need for modification to the factors of the 'increase of spiritual interest' in the existing PTGI is suggested. We examined the factor structure, reliability, and validity of a Korean version of the PTGI-X among 625 Korean adults who have experienced trauma events. First, EFA confirmed the appropriate PTGI-X factor structure and found that the 4-factor structure was the most appropriate. Next, as a result of CFA, it was found that the model to which correlation between items was added to the 4-factor model was good. Next, testing internal consistency, CR, and AVE of the K-PTGI-X showed that PTGI-X's items are reliable. Also, we tested the concurrent validity and discriminative validity. All of the K-PTGI-X scales significantly correlated with measures of deliberate rumination and core-belief except for the intrusive rumination. Finally, to add an understanding of K-PTGI-X, t-test according to demographic variables was conducted. Recommendations for future research and implications were discussed.

Dielectric Properties of Strontium-substituted Lead Magnesium Tungstate up to Microwave Frequencies

  • Kim, J.H.;Choo, W.K.
    • The Korean Journal of Ceramics
    • /
    • v.4 no.4
    • /
    • pp.394-398
    • /
    • 1998
  • $Pb_{1-x}Sr_x(Mg-{1}2}W_{1}2})O_3$$ ceramics for application in the microwave frequency range were investigated by dielectric constant and X-ray diffraction measurements. The dielectric constant curves showed two concentration dependent characteristics in the $$Pb(Mg-{1}2}W_{1}2})O_3$-rich$ region. As the Sr constant further increases to x=0.3 the dielectric curve levels off. In the concentration range between x=0.4 and x=1 in which dielectric constant dependence on temperature is negligible, it decreases and Qf value increases in the microwave frequency with increasing Sr. The temperature coefficient (${\tau}_{\varepsilon} $) of the dielectric constant changes from the negative to positive value between x=0.9 and x=1. The dielectric constant, Qf and $\tau\varepsilon$ are correlated with tolerance factor(t). From the X-ray diffraction results for $0.1{\le}x{\le}1$ the cell parameter is found to decrease as x increases and B-site ordering is observed in all the composition ranges.

  • PDF

비납계 $(1-x)(Bi_{0.5}K_{0.5})TiO_3-xBiFeO_3$ 세라믹의 유전 및 압전 특성

  • Kim, Jeong-Min;Seong, Yeon-Su;Song, Tae-Gwon;Kim, Myeong-Ho
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.33.2-33.2
    • /
    • 2009
  • Dielectric and piezoelectric properties of Lead-free $(1-x)(Bi_{0.5}K_{0.5})TiO_3-xBiFeO_3$ceramics prepared by a conventional solid state reaction method were investigated in the range of x = 0~10 mol%. Piezoelectric coefficient was increased from 31 pC/N at x = 0 mol% to 64 pC/N at x = 6 mol% then decreased with increasing x. Electromechanical coupling factor ($K_p$) was increased up to 0.18 at x = 10 mol%. On the other hand, mechanical quality factor ($Q_m$) was decreased. Grain size was not much changed with various x and a single perovskite with tetragonal symmetry was maintained at all compositions forming a solid solution between $(Bi_{0.5}K_{0.5})TiO_3$ and $BiFeO_3$. Depolarization temperature ($T_d$) was gradually decreased with increasing x from $302^{\circ}C$ at x = 0 to $245^{\circ}C$ at x = 10 mol%.

  • PDF

The Correlation Analysis and Correction factor of BMD in Forearm and Lumbar with DXA (DXA를 이용한 전완부와 요추부 골밀도 검사의 보정계수 및 상관관계 연구)

  • Han, Man-Seok
    • Journal of Digital Convergence
    • /
    • v.11 no.12
    • /
    • pp.551-556
    • /
    • 2013
  • The Forearm and the lumbar spine bone mineral density bone mineral density values obtained through, T-score and Z-score correlation between numerical and calibration function obtained as a result of any one part to another part of the results is intended to infer. Groups of 66 patients, 11 patients by age 20-70 were composed of patients measured with the forearm and lumbar spine bone mineral density T-score and Z-score of the survey for each of the three factors that correlated to assess the correlation Find the correction factor to obtain the relationship. Bone mineral density of the correlation coefficient R = 0.769 correction factor is Y = 1.541X + 0.133. T-score of correlation coefficient R = 0.768 and the correction factor Y = 0.715X - 0.4 is Z-score of the correlation coefficient R = 0.635 correction factor Y = 0.751X - 0.162. It is regarded that there will be a clinical availability which can analogize the result of a part by using the result of the other part.