• Title/Summary/Keyword: X-Ray structure

Search Result 3,699, Processing Time 0.033 seconds

Structure Study of Polycrystalline $Na_3YSi_3O_9$ and Its Substitutes Related to $Na_4CaSi_3O_9,\;Ca_3Al_2O_6$ Structure

  • Kim, Chy-Hyung;Banks, Ephraim
    • Bulletin of the Korean Chemical Society
    • /
    • v.8 no.1
    • /
    • pp.6-9
    • /
    • 1987
  • The study of the $Na_3YSi_3O_9$ structure, by x-ray diffraction and infrared spectrum, showed that $Na_3YSi_3O_9$ is similar to $Na_4CaSi_3O_9$ except for its being pseudo-cubic instead of cubic. The peaks in the x-ray diffraction pattern of $Na_3YSi_3O_9$ could therefore be indexed on the basis of the $Na_4CaSi_3O_9$ cell. Also, modified $Na_3MSi_3O_9$ (M = Lu, Yb, Tm, Er, Y, Ho, Dy, Gd, Eu, and Sm) type compounds were synthesized by introducing excess sodium, decreasing M(III) concentration, and substituting small amount of phosphorus for silicon. The unit cell parameters of the composition $Na_{3.2}M_{0.7}Si_{2.9}P_{0.1}O_{8.7}$ were estimated from x-ray powder diffraction patterns using the Cohen method.

Chemical and Electronic structures of $Co_{1-x}Ga_x$ alloys by X-ray Analyses (X-선을 이용한 $Co_{1-x}Ga_x$ 합금계의 화학구조와 전자구조)

  • 유권국;이주열;지현배;이연승
    • Journal of the Korean Vacuum Society
    • /
    • v.13 no.2
    • /
    • pp.86-91
    • /
    • 2004
  • Transiton-metal gallides attract wide interest as a candidate for high-temperature structural materials. In a wide composition range, in which it was known that Co-Ga alloy have CsCl (B2) crystallographic structure, a systematic study on the correlation between physical properties and electronic structures of Co-gallides was performed. $Co_{l-x}Ga$ $_{x}$ alloys ($0.35\leq$x$\leq0.55$) were prepared by arc-melting method and were annealed at $1000 ^{\circ}C$ for 48hour to increase the homogeneity. In this composition range all the prepared alloys have the CsCl (B2) structure. The chemical states and the electronic structure were studied by using x-ray photoemission spectroscopy (XPS), and x-ray absorption near-edge structure (XANES), and exhibit different physical properties depending on the composition. During the annealing, a significant oxidation has happened and all the oxygen atoms are incorporated with the Ga atoms to form a $Ga_2O_3$ phase. In a view point of electronic structure, the $Co_{l-x}Ga$ $_{x}$ alloys were formed by the Ga(p) - Co(d) hybridization.

The X-ray Detection Characteristic of vacuum evaporated CsI for Digital X-ray Image Sensor (디지털 X선 영상센서 적용을 위한 진공증착 CsI 특성평가)

  • Shin, Jung-Wook;Park, Ji-Koon;Choi, Jang-Yong;Seok, Dea-Woo;Kim, Jea-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.15-18
    • /
    • 2003
  • In recent years, there has been keen interest in phosphor materials responding X-ray. Cesium iodide of the materials is a material with a high $\gamma$-ray stopping power due to its relative high density and atomic number. CsI is noted for its high resistance to thermal and mechanical shock due to the absence of a cleavage plane. To design the structure of CsI detector, we analysed the structure with SEM and XRD and measured UV meter.

  • PDF

A Study on the Removal of Electrostatic using Transmitted Ions Generated Soft X-ray with Compressed Air (기류방출형 연X선 조사에 의한 정전기 제거 장치에 관한 연구)

  • Kwon, Sung-Yul;Lee, Dong-Hoon;Choi, Jae-Wook;Seo, Min-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.1
    • /
    • pp.27-31
    • /
    • 2010
  • It is a well known fact that the LCD and Semiconductor Devices are a central part of IT industry which is important in the present and the future. But the biggest problem of Semiconductor and LCD manufacturing is maintaining a cleaning room environment. For this reason, the soft X-ray type Ionizer was used as the electrostatic reducer device, which protects damage of the product against electrostatic discharge in the manufacturing process. Therefore it is a essential important factor during Semiconductor and LCD production process. But the soft X-ray has a intrinsic problem with harmful to human being in case of soft X-ray exposure. That's reason we have the research to solve above problem and made an apparatus that it was covered with shielding structure to protect X-ray radiation to outside. And besides, it has a possibility to eliminate the charged electrostatic in the narrow space through the slot for Ion emissions with dual soft X-ray sources on the both side. It is also not make the particles from itself when it has been operated.

Evaluation Method of Rock Characteristics using X-ray CT images (X-ray CT 이미지를 이용한 암석의 특성 평가 방안)

  • Kim, Kwang Yeom;Yun, Tae Sup
    • Tunnel and Underground Space
    • /
    • v.29 no.6
    • /
    • pp.542-557
    • /
    • 2019
  • The behavior of rock mass is influenced by its microscopic feature of internal structure generating from forming and metamorphic process. This study investigated a new methodology for characterization of rock based on the X-ray CT (computed tomography) images reflecting the spatial distribution characteristics of internal constituent materials. The X-ray image based analysis is capable of quantification of heterogeneity and anisotropy of rock fabric, size distribution and shape parameter analysis of rock mineral grains, fluid flow simulation based on pore geometry image and roughness evaluation of unexposed joint surface which are hardly acquired by conventional rock testing methods.

A Monochromatic X-Ray CT Using a CdTe Array Detector with Variable Spatial Resolution

  • Tokumori, Kenji;Toyofuku, Fukai;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.411-414
    • /
    • 2002
  • The CdTe semiconductor detector has a higher detection efficiency for x-rays and $\square$amma rays and a wider energy band gap compared with Si and Ge semiconductor detectors. Therefore, the size of the detector element can be made small, and can be operated at room temperature. The interaction between a CdTe detector and incident x-rays is mainly photoelectric absorption in the photon energy range of up to 100 keV. In this energy range, Compton effects are almost negligible. We have developed a 256 channel CdTe array detector system for monochromatic x-ray CT using synchrotron radiation. The CdTe array detector system, the element size of which is 1.98 mm (h) x 1.98 mm (w) x 0.5 mm (t), was operated in photon counting mode. In order to improve the spatial resolution, we tilted the CdTe array detector against the incident parallel monochromatic x-ray beam. The experiments were performed at the BL20B2 experimental hutch in SPring-8. The energy of incident monochromatic x-rays was set at 55 keV. Phantom measurements were performed at the detector angle of 0, 30 and 45 degrees against the incident parallel monochromatic x-rays. The linear attenuation coefficients were calculated from the reconstructed CT images. By increasing the detector angle, the spatial resolutions were improved. There was no significant difference between the linear attenuation coefficients which were corrected by the detector angle. It was found that this method was useful for improving the spatial resolution in a parallel monochromatic x-ray CT system.

  • PDF

Thermal behavior of the layered structure of decanesulfonate intercalated into the hydrated nickel compound (데칸술폰이 삽입된 니켈 화합물의 층상 구조의 열적 성질)

  • 허영덕;전태현;박용준
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.9 no.6
    • /
    • pp.580-584
    • /
    • 1999
  • The synthesis and characterization of intercalated compound of decansulfonate into hydrated nickel is presented. The compound shows a layered structure as determined by high temperature powder X-ray diffraction (HTXRD). The layer distance of the product is increased from 24.7 $\AA$ to 30.5 $\AA$ by increasing the temperature which is in turn accomplished by changing the structure of the intercalated nickel compound. From the X-ray diffraction data and the decanesulfonate size, the orientation of the decanesulfonate onto the nickel layer is determined. The molecular axis of the decanesulfonate with bilayer structure is tilted to the perpendicular of the nickel layer.

  • PDF

Development of X-ray Micro Computed Tomography and Applications (미세 X선 단층촬영 기법의 개발과 적용)

  • Kim, Seung-Gon;Lim, Jae-Hong;Kim, Bo-Heum;Lee, Eui-Jae;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.2
    • /
    • pp.45-50
    • /
    • 2010
  • The objective of this study is to elucidate the feasibility of synchrotron X-ray micro CT as a non-destructive imaging method to visualize the three-dimensional morphological structures of biological and non-biological samples. The experiments were conducted in 7B2 X-ray micro CT beamline in Pohang Accelerate Laboratory (PAL). A rotational 3-axis stage was specially designed for $0^{\circ}-180^{\circ}$ scanning of test samples. Preliminary tests were performed for opaque samples including a mosquito head, a plant seed and gas diffusion layer (GDL) of polymer electrolyte fuel cell to verify the feasibility of the X-ray micro CT. It visualized clearly the internal structure of all the test samples, supporting its usefulness.

Correlation between composition and structure of PtxNiy alloy nanodendrites

  • Lee, Young-Woo;Kwak, Da-Hee;Park, Kyung-Won
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.26 no.5
    • /
    • pp.165-170
    • /
    • 2016
  • We have synthesized $Pt_xNi_y$ alloy nanodendrites by a thermal decomposition method. The structure and composition of the as-prepared samples were characterized by field-emission transmission electron microscopy (FE-TEM), energy dispersive X-ray (EDX) spectroscopy, and X-ray diffraction (XRD). The growth mode of the $Pt_xNi_y$ alloy samples synthesized as a function of an intended atomic fraction of Ni was likely to be strongly affected by and reduction (or oxidation) potentials and surface energy.

Crystal Structure of $KD_2PO_4$: Neutron and X-ray Diffraction Studies ($KD_2PO_4$의 결정구조: 중성자와 X-선 회절에 의한 연구)

  • 김신애;심해섭;이창희
    • Korean Journal of Crystallography
    • /
    • v.11 no.3
    • /
    • pp.162-166
    • /
    • 2000
  • KD₂PO₄ single crystals were grown from D₂O with reagent KH₂PO₄ and the crystal structure was determined by X-ray and neutron diffraction methods. The crystals are tetragonal at room temperature, I42d, with lattice parameters of a=7.4633(7), c=6.9785(5) Å and Z=4. Intensity data were collected on an Enraf-nonius CAD4 diffractometer with a graphite monochromated MoK/sub α/ radiation (λ=0.7107Å) and on the neutron four circle single crystal diffractometer with Ge(331) monochromated neutron beam (λ=0.997Å). The structure was refined by full-matrix least-square to final R and wR values of 0.030 and 0.072, respectively, for 204 observed reflections with I>2σ(I) by X-ray diffraction and to final R=0.041 and wR=0.096 for 144 observed relfecdtions by neutron diffraction. The O…O distance of 2.516(4)Å obtained by X-ray diffraction is the same as that of 2.515(4)Å by neutron diffraction. On the other hand, the O-D/H distance of 0.84(4)Å by X-ray diffraction is considerably shorter than 1.029(7) Åby neutron diffraction. Hydrogen and deuterium can be readily distinguished by neutrons. In this crystal 66% of H-positions were substituted by D and the rest 34% occupied by H. The phase transition temperature of DKDP obtained with deuteration levels is f193K. This value agrees fairly well with the result of DSC measurement. The nuclear density distribution by neutron diffraction provides an observation of the disordered state of D/H in KD₂PO₄ at room temperature.

  • PDF