• 제목/요약/키워드: X-Ray Tomography

검색결과 804건 처리시간 0.028초

Does Simultaneous Computed Tomography and Quantitative Computed Tomography Show Better Prescription Rate than Dual-energy X-ray Absorptiometry for Osteoporotic Hip Fracture?

  • Ko, Jae Han;Lim, Suhan;Lee, Young Han;Yang, Ick Hwan;Kam, Jin Hwa;Park, Kwan Kyu
    • Hip & pelvis
    • /
    • 제30권4호
    • /
    • pp.233-240
    • /
    • 2018
  • Purpose: This study aimed to evaluate the efficacy of simultaneous computed tomography (CT) and quantitative CT (QCT) in patients with osteoporotic hip fracture (OHF) by analyzing the osteoporosis detection rate and physician prescription rate in comparison with those of conventional dual-energy X-ray absorptiometry (DXA). Materials and Methods: This study included consecutive patients older than 65 years who underwent internal fixation or hip arthroplasty for OHF between February and May 2015. The patients were assigned to either the QCT (47 patients) or DXA group (51 patients). The patients in the QCT group underwent QCT with hip CT, whereas those in the DXA group underwent DXA after surgery, before discharge, or in the outpatient clinic. In both groups, the patients received osteoporosis medication according to their QCT or DXA results. The osteoporosis evaluation rate and prescription rate were determined at discharge, postoperative (PO) day 2, PO day 6, and PO week 12 during an outpatient clinic visit. Results: The osteoporosis evaluation rate at PO week 12 was 70.6% (36 of 51 patients) in the DXA group and 100% in the QCT group (P<0.01). The prescription rates of osteoporosis medication at discharge were 70.2% and 29.4% (P<0.001) and the cumulative prescription rates at PO week 12 were 87.2% and 60.8% (P=0.003) in the QCT and DXA groups, respectively. Conclusion: Simultaneous CT and QCT significantly increased the evaluation and prescription rates in patients with OHF and may enable appropriate and consistent prescription of osteoporosis medication, which may eventually lead to patients' medication compliance.

Micro X-ray CT 촬영을 통한 동결 사질토 시료의 세립분 함유량에 따른 입자간 거리 분석 (Particle Spacing Analysis of Frozen Sand Specimens with Various Fine Contents by Micro X-ray Computed Tomography Scanning)

  • 채덕호;이장근;김광염;조완제
    • 한국지반환경공학회 논문집
    • /
    • 제18권1호
    • /
    • pp.31-35
    • /
    • 2017
  • Chae et al.(2015)에 따르면 동결 사질토의 역학적 거동은 동결온도와 세립분 함유량에 따라 크게 영향을 받는 것으로 나타났다. 이러한 원인으로 동결온도에 따른 부동수분의 차이일 것이라는 의견과 세립분 함유량 및 간극 내 얼음에 의해 사질토 입자들 이격거리 차이에 의한 것이라는 의견이 제시되었다. 제시된 두 가지 의견 중 사질토 입자들 이격거리의 확인을 위해 micro X-ray CT 촬영을 수행하였다. X-ray CT 촬영에 의한 비파괴 검사는 최근 지반공학 분야에서 진행되고 있는 다양한 융복합 연구 중 하나로 CT 촬영을 통하여 지반재료의 내부 구조를 마이크로미터 단위의 높은 해상도를 통해 평가할 수 있는 방법이다. 본 연구에서는 -5, -10, $-15^{\circ}C$의 동결온도에서 성형된 5, 10, 15%의 세립분을 포함하고 있는 동결 사질토 공시체에 대하여 micro X-ray CT 촬영을 수행하고 기존의 개발된 이미지 해석 기법을 적용하여 동결 사질토 내의 조립질 입자들의 최단거리 및 평균거리를 통하여 세립분 함유량 및 동결온도가 조립질 입자간의 거리에 미치는 영향을 파악하고자 하였다. X-ray CT 촬영 결과, 동결온도 및 세립분 함유량은 동결 사질토 내 입자간 거리에는 큰 영향을 미치지 않는 것으로 나타났다.

현장 적용이 가능한 X선 CT 시스템 개발 I - X선 촬영법을 이용한 목재의 밀도 측정 - (Development of Portable X-ray CT System I - Evaluation of Wood Density using X-ray Radiography -)

  • 김광모;이상준;이전제
    • Journal of the Korean Wood Science and Technology
    • /
    • 제34권1호
    • /
    • pp.15-22
    • /
    • 2006
  • 국내에서 문화재로 지정되어 관리되고 있는 많은 목조 고건축물들의 효과적인 보존 및 관리를 위해서는 목재의 내부 상태를 정확하게 평가할 수 있든 비파괴 검사법이 요구된다. 따라서 본 연구에서는 현장에서 적용 가능한 X선 CT 시스템을 개발하기 위한 연구의 일환으로, 먼저 휴대형 soft-X선 촬영 장치를 사용한 목재의 밀도측정 방법을 확립하고 그 적용 가능성을 확인하고자 하였다. 먼서 측정방법을 확립하기 위하여 X선 강도와 필름명도 사이의 상관관계를 분석하였으며, 또한 관전류와 관전압의 변화에 따른 X선 초기강도의 변화를 확인하여 정량화 하였다. 다음으로 목재의 밀도와 연륜각, 두께가 질량감쇠계수에 미치는 영향을 확인하고, 목재의 침량감쇠계수를 결정하여 Beer의 법칙에 적용함으로써 X선 측정결과로부터 목재의 밀도를 계산할 수 있는 식을 제시하였다. 마지막으로 X선 촬영법을 통해 측정한 밀도를 기존의 치수법에 의한 측정결과와 비교함으로써 앞에서 결정된 밀도측정 방법의 작용 가능성을 확인할 수 있었다. 이상의 결과는 앞으로 개발하고자 하는 X선 CT 시스템에서 입력값으로 요구되는 밀도를 측정하는 방법을 확립하는데 있어서 효과적으로 활용될 수 있을 것으로 기대된다.

X선 영상 장치를 이용한 핵연료 집합체 내 기포율 측정을 위한 선행 연구 (A Preliminary Study on Measuring Void Fraction in a Fuel Rod Assembly by using an X-ray Imaging System)

  • 이선영;오오성;이세호;이승욱
    • 한국방사선학회논문지
    • /
    • 제11권7호
    • /
    • pp.571-578
    • /
    • 2017
  • 원자로 내 사고발생 시 냉각수의 비등으로 기포가 발생하고, 기포율을 측정하기 위하여 열수력 안전 분야에서는 주로 Optical Fiber Probe(OFP)나 광학 카메라를 이용하여 측정하지만 기하학적 구조의 한계로 인해 $17{\times}17$ 배열의 봉 다발 내에 장비를 설치하는 것에는 어려움이 있다. 본 연구는 예비 연구로서 봉 다발에 적용하기 전 X선 시스템과 다양한 모사 팬텀을 이용하여 연구 가능성 평가를 수행하였다. 라디오그라피 및 토모그라피 실험을 통해 X선 발생 장치의 관전압 130 kVp, 관전류 1 mA가 적합하였다. 또한, 기포 해상도 팬텀을 통해 가시적으로 1 mm 크기의 구멍에 대해 측정이 가능하였으며 막대 팬텀을 이용한 대조도 평가의 경우 프레온 내부에서 대조도가 상대적으로 떨어짐을 확인할 수 있었다. 그러나 영상 재구성 시 일그러짐이 없는 좋은 영상을 획득할 수 있었다. 기포 발생 팬텀 실험을 통해 기포의 유동 방향 확인 및 단층 영상을 획득할 수 있었고, Image J 툴을 이용하여 하나의 단층영상에 대해 18 %의 기포율을 측정할 수 있었다. 본 연구는 핵연료 주변 기포율 측정을 위한 선행 연구를 수행하였고 지속적인 연구를 위한 기초 연구로서 활용할 수 있을 것이다.

양성자 전산화 단층 촬영 장치 개발에 관한 전산모사 연구 (Development of a Proton Computed Tomography System with Monte Carlo Simulation)

  • 서정민;김찬형
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권3호
    • /
    • pp.215-219
    • /
    • 2011
  • 양성자 치료에서 X선 영상정보가 직접적인 양성자의 저지능 정보를 제공할 수 없는 한계로 인한 자료의 오류를 피하기 위해, 양성자 빔을 이용한 전산화단층촬영 영상의 사용을 위한 전산모사 연구를 시행하고, 적절한 하드웨어 구성과 그 가능성을 연구하였다. GEANT4를 사용한 전산모사에서 두 개의 DSSD를 사용하여 입사되는 양성자 빔의 위치정보를 획득하고 LYSO 섬광검출기로 에너지를 측정하여 획득한 양성자 영상을 단층촬영 영상으로 재구성하여 사용할 수 있음을 확인하였다.

Basic principles and applications of $^{18}F$-FDG-PET/CT in oral and maxillofacial imaging: A pictorial essay

  • Omami, Galal;Tamimi, Dania;Branstetter, Barton F.
    • Imaging Science in Dentistry
    • /
    • 제44권4호
    • /
    • pp.325-332
    • /
    • 2014
  • A combination of positron emission tomography (PET) with $^{18}F$-labeled fluoro-2-deoxyglucose ($^{18}F$-FDG) and computed tomography ($^{18}F$-FDG-PET/CT) has increasingly become a widely used imaging modality for the diagnosis and management of head and neck cancer. On the basis of both recent literature and our professional experience, we present a set of principles with pictorial illustrations and clinical applications of FDG-PET/CT in the evaluation and management planning of squamous cell carcinoma of the oral cavity and oropharynx. We feel that this paper will be of interest and will aid the learning of oral and maxillofacial radiology trainees and practitioners.

PET/CT를 이용하여 진단한 구강암의 증례 (Oral cancer diagnosed using PET/CT: A case report)

  • 김영희;양병은;조영민;김성곤
    • Imaging Science in Dentistry
    • /
    • 제36권2호
    • /
    • pp.111-116
    • /
    • 2006
  • PET/CT is a new imaging technology that combines high-quality Positron Emission Tomography (PET) and Computed Tomography (CT). This imaging provides simultaneous anatomical and metabolic information. Therefore PET/CT is useful diagnostic modality for early detection of malignant tumor, accurate staging, decision on therapeutic plan, monitoring response to therapy and rapid detection of recurrence. We report oral and maxillofacial cancers diagnosed by using PET/CT and the usefulness of PET/CT in the evaluation of postoperative recurrence.

  • PDF

Cone beam형 전산화단층영상의 원리 (Basic principle of cone beam computed tomography)

  • 최용석;김규태;황의환
    • Imaging Science in Dentistry
    • /
    • 제36권3호
    • /
    • pp.123-129
    • /
    • 2006
  • The use of computed tomography for dental procedures has increased recently. Cone beam computed tomography (CBCT) systems have been designed for imaging hard tissues of the dentomaxillofacial region. CBCT is capable of providing high resolution in images of high diagnostic quality. This technology allows for 3-dimensional representation of the dentomaxillofacial skeleton with minimal distortion, but at lower equipment cost, simpler image acquisition and lower patient dose. Because this technology produces images with isotropic sub-millimeter spatial resolution, it is ideally suited for dedicated dentomaxillofacial imaging. In this paper, we provide a brief overview of cone beam scanning technology and compare it with the fan beam scanning used in conventional CT and the basic principles of currently available CBCT systems.

  • PDF

치과 분야 연구에서 미세전산화 단층촬영술의 이론: 치아우식증에 대한 적용 (Theory of X-ray microcomputed tomography in dental research: application for the caries research)

  • 박영석;배광학;장주혜;손원준
    • Restorative Dentistry and Endodontics
    • /
    • 제36권2호
    • /
    • pp.98-107
    • /
    • 2011
  • 치아우식증은 현대 사회에서 여전히 유병률이 높으며, 치과 분야의 주요 상병으로 자리잡고 있다. 치아우식증에 대한 연구에 매우 다양한 방법들이 동원되고 있으나, 최근 미세전산화 단층촬영은 비파괴적인 3차원 분석 기술로서 인기를 얻어 왔으며, 기존의 방법들에 비해 다양한 장점들을 가지고 있다. 미세전산화 단층촬영술은 X선원의 종류에 따라, 모노크로매틱 혹은 폴리크로매틱으로 나뉘어지고, 전자의 경우 몇몇 장점에도 불구하고, 고가의 장비를 요구하므로 후자가 훨씬 널리 사용된다. 투과방사선량의 감소에 따라 결정되는 미네랄 밀도의 차이가 기본 원리이며, 보다 좋은 이미지와 재현 가능한 측정을 위해서는 장비의 교정과 이미지 보정 작업등이 요구된다. 또한, 미세전산화 단층촬영술을 이용하면, 치아우식 병소의 3차원적인 재건이 가능하며, 병소의 내부 구조를 가시화할 수 있다. 최근 컴퓨터 기술의 발전과 더불어 다양한 응용이 시도되고 있는데, 자동화된 충치의 정량적 분석 알고리즘 등이 그 예에 해당된다.

Utility of the computed tomography indices on cone beam computed tomography images in the diagnosis of osteoporosis in women

  • Koh, Kwang-Joon;Kim, Kyoung-A
    • Imaging Science in Dentistry
    • /
    • 제41권3호
    • /
    • pp.101-106
    • /
    • 2011
  • Purpose : This study evaluated the potential use of the computed tomography indices (CTI) on cone beam CT (CBCT) images for an assessment of the bone mineral density (BMD) in postmenopausal osteoporotic women. Materials and Methods : Twenty-one postmenopausal osteoporotic women and 21 postmenopausal healthy women were enrolled as the subjects. The BMD of the lumbar vertebrae and femur were calculated by dual energy X-ray absorptiometry (DXA) using a DXA scanner. The CBCT images were obtained from the unilateral mental foramen region using a PSR-$9000N^{TM}$ Dental CT system. The axial, sagittal, and coronal images were reconstructed from the block images using $OnDemend3D^{TM}$. The new term "CTI" on CBCT images was proposed. The relationship between the CT measurements and BMDs were assessed and the intra-observer agreement was determined. Results : There were significant differences between the normal and osteoporotic groups in the computed tomography mandibular index superior (CTI(S)), computed tomography mandibular index inferior (CTI(I)), and computed tomography cortical index (CTCI). On the other hand, there was no difference between the groups in the computed tomography mental index (CTMI: inferior cortical width). Conclusion : CTI(S), CTI(I), and CTCI on the CBCT images can be used to assess the osteoporotic women.