• Title/Summary/Keyword: X선조사야

Search Result 478, Processing Time 0.034 seconds

Studies on the Normal Frequency and Effects of X-irradiation on Sex Chromatin of Neutrophil Leukocyte in the Rabbit (가토의 호중성백혈구 성염색질의 정상빈도와 X선조사에 대하여)

  • PARK, Tae-Kyu;KIM, Moo-Yun
    • The Korean Journal of Zoology
    • /
    • v.9 no.1
    • /
    • pp.16-20
    • /
    • 1966
  • The frequency of sex chromatin in neutrophil leukocyte of 14 female and 4 male normal, adult rabbits was examined and compared to those of single total X-ray irradiation. 1. The average frequency of of drumstck was 9 % in female and 0.1% in male, and that of sessile nodule was 3.35% in female and 0.9% in male , in normal condition rabbit . These results fairly determined sex ratio by sex chromatin in neutrophil leukocyte. 2. The drumstick frequency reduces to half after X-irradiaton but did not show any regular tendency or variation in morphologicla form, indicating the stability of chromatin to X-irradiation. 4. The chromatin satellite was found with a reasonable frequency in the some kinds of irradiated cells, polymorphonuclear neutrophil (above 7 lobes 0 and megakarycyte.

  • PDF

Effect of X-ray Exposure on Phase Separation of Lysozyme-Water Mixture (X선 쬐임이 단백질-물 상분리에 미치는 영향)

  • Cho, Chang-Ho;Sung, Syng-Hoon;Lee, Sang-Soo;Cho, Kun-woo
    • The Journal of Natural Sciences
    • /
    • v.11 no.1
    • /
    • pp.23-26
    • /
    • 1999
  • Phase separation temperature of lysozyme-water mixture increased with X-ray exposure on lysozyme and decreased with impurity of saponin. The intensity of light scattering in lysozyme-water mixture with X-ray exposure on lysozyme decreased as a function as a function of temperature, and decreased with impurity of saponin.

  • PDF

Analysis of Charred-Woods Excavated from the Daewoongjeon Hall of Youngguksa Temple (영국사 대웅전 출토 탄화목의 재질 분석)

  • Son, Byung Hwa;Park, Won-Kyu
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.1
    • /
    • pp.36-43
    • /
    • 2007
  • Elemental analysis, SEM-EDX, X-ray diffraction (XRD) and IR analysis were adopted to examine the quality of charred woods excavated from the underground of the Daewoongjeon Hall of Youngguksa Temple, Youngdong-gun, Chungbuk, Korea. A large amount of calcium was detected in SEM-EDX analysis. The analyses of chemical elements suggested that completely charred wood was carbonized at about $500^{\circ}C$. The XRD results indicated the destruction of cellulose crystalline region. The IR analysis exhibited that thermal degradation of wood component was different depending upon the carbonization temperature. It can be suggested from the results that PEG with different molecular weights should be used for the conservation of excavated charred woods.

Comparison of Center Error or X-ray Field and Light Field Size of Diagnostic Digital X-ray Unit according to the Hospital Grade (병원 등급에 따른 X선조사야와 광조사야 간의 면적 및 중심점 오차 비교)

  • Lee, Won-Jeong;Song, Gyu-Ri;Shin, Hyun-yi
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.245-252
    • /
    • 2020
  • The purpose of this study was intended to recognize the importance of quality control (QC) in order to reduce exposure and improve image quality by comparing the center-point (CP) of according to hospital grade and the difference between X-ray field (XF) and light field (LF) in diagnostic digital X-ray devices. XF and LF size, CP were measured in 12 digital X-ray devices at 10 hospitals located in 00 metropolitan cities. Phantom was made in different width respectively, using 0.8 mm wire after attaching to the standardized graph paper on transparent plastic plate and marked as cross wire in the center of the phantom. After placing the phantom on the table of the digital X-ray device, the images were obtained by shooting it vertically each field of survey. All images were acquired under the same conditions of exposure at distance of 100cm between the focus-detector. XF and LF size, CP error were measured using the picture archiving communication system. data were expressed as mean with standard error and then analyzed using SPSS ver. 22.0. The difference in field between the XF and LF size was the smallest in clinic, followed by university hospitals, hospitals and general hospitals. Based on the university hospitals with the least CP error, there was a statistically significant difference in CP error between university hospitals and clinics (p=0.024). Group less than 36-month after QC had fewer statistical errors than 36-month group (0.26 vs. 0.88, p=0.036). The difference between the XF and LF size was the lowest in clinic and CP error was the lowest in university hospital. Moreover, hospitals with short period of time after QC have fewer CP error and it means that introduction of timely QC according to the QC items is essential.

하부전극 물질에 따른 CdTe박막 증착과 그에 따른 전기적 특성 평가

  • Kim, Dae-Guk;Sin, Jeong-Uk;Lee, Yeong-Gyu;Kim, Seong-Heon;Lee, Geon-Hwan;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.327-328
    • /
    • 2012
  • 의료분야의 진단 방사선 장비는 초기의 필름방식 및 카세트에서 진보되어 현재는 디지털방식의 DR (Digital Radiography)이 널리 사용되며 이에 관한 연구개발이 활발히 진행 되고 있다. DR은 일반적으로 직접방식과 간접방식으로 나눌 수 있다. 직접방식의 원리는 X선을 흡수하면 전기적 신호를 발생 시키는 광도전체(Photoconductor)를 사용하여 광도전체 양단 전극에 전압을 인가하여 전기장을 유도한 가운데, X선을 조사하면 광도전체 내부에서 전자-전공쌍(Electron-hole pair)이 생성된다. 이것은 양단에 유도된 전기장의 영향으로 전자는 +극으로, 전공은 -극으로 이동하여 아래에 위치한 하부기판을 통하여 이미지로 변조된다. 간접방식은 X선을 흡수하면 가시광선으로 전환하는 형광체(Scintillator)를 사용하여 조사된 X선을 형광체에서 가시광선으로 전환하고, 이를 Photodiode와 같은 광변환소자로 전기적 신호로 변환하여 방사선을 검출하는 방식을 말한다. 본 연구에서는 직접방식에서 이용되는 광도전체 중 흡수효율이 높고 Mobility가 뛰어난 CdTe를 선정하여 PVD (Physical vapor deposition)방식으로 300 m의 두께를 목표로 하여 증착을 진행하였다. Chamber의 진공도가 $2.5{\times}10^{-2}$ Torr로 도달 시점부터, Substrate와 Boat에 열을 가하였다. Substrate온도는 $350^{\circ}C$, Boat온도는 $300^{\circ}C$도로 설정하여 11시간 동안 진행하였다. Substrate온도는 $303^{\circ}C$, Boat온도는 $297^{\circ}C$도부터 증착이 시작되어 선형적인 증가세 추이를 나타내어 Substrate 및 Boat온도가 설정 값에 도달 하였을 때, $25{\sim}34.4{\AA}/s$ 증착율을 나타내었다. 하부전극의 물질에 따른 CdTe증착 효율성 평가를 진행한 후, 그에 따른 전기적 특성을 알아보았다. 하부전극의 물질로는 ITO (Indium Tin Oxide), Parylene이 코팅 된 ITO, Au, Ag를 사용하였다. 하부전극의 물질 상단에 Thermal Evaporation System을 사용하여 CdTe를 증착한 후, Cdte 상단에 Au를 증착 시켜 민감도(Sensitivity)와 암전류(Dark current)를 측정하였다. 증착 결과 ITO와 Ag상단에 증착시킨 CdTe박막은 박리가 되었고, Au와 Parylene이 코팅 된 ITO에는 CdTe박막이 안정적이게 형성이 되었다. 이 두 샘플에 대하여 동일한 조건으로 민감도와 암전류를 측정 시, Parylene이 코팅된 ITO를 하부전극으로 사용한 CdTe박막은 0.1021 pA/$cm^2$의 암전류와 1.027 pC/$cm^2$의 민감도를 나타낸 반면, Au를 하부전극으로 사용한 CdTe박막은 0.0381 pA/$cm^2$의 암전류와 1.214 pC/$cm^2$의 민감도를 나타내어 Parylene이 코팅된 ITO보다 우수한 전기적 특성을 나타내었다. 따라서 Au는 CdTe박막 증착 시, 하부전극 기판으로서 뛰어난 특성을 나타내는 것을 알 수 있었다.

  • PDF

A Study on the Chest Indirect Radiography (흉부X선 간접촬영의 촬영조건과 화질에 관한 조사연구)

  • Kim, Hark-Sung;Lee, In-Ja;Kim, Sung-Soo;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.11-19
    • /
    • 2003
  • chest Indirect radiography were taken at 44 medical facilities in Seoul area. The results were as follows: 1. The average tube voltage was 98.2 kVp in case of 100 mm film and 91.3 kVp in case of 70 mm film. 2. The average tube current was 18.1 mAs in case of 100 mm film and 42.5 mAs in case of 70 mm film. 3. In the physical evaluation of chest Indirect radiographs, the density in case of 100 mm film was similar to that in case of 70 mm film. 4. In the visual evaluation of chest Indirect radiographs, the score of identification in case of 100 mm film was higher than that in case of 70 mm film. 5. The average dose of radiation into the skin was 1.38 mGy in case of 100mm film and 4.59 mGy in case of 70 mm film. In conclusion, the image quality of chests was excellent and the dose of radiation into the skin decreased in case of 100 mm film.

  • PDF

Patient Radiation Exposure Dose Evaluation of Whole Spine Scanography Due to Exposure Direction (Whole Spine Scanography의 검사방향에 따른 환자 선량 평가)

  • Kim, Jung-Su;Seo, Deok-Nam;Kwon, Soon-Mu;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Whole spine scanography (WSS) is a radiological examination that exposes the whole body of the individual being examined to x-ray radiation. WSS is often repeated during the treatment period, which results in a much greater radiation exposure than that in routine x-ray examinations. The aims of the current study were to evaluate the patient dose of WSS using computer simulation, image magnification and angulation of phantom image using different patient position. We evaluated the effective dose(ED) of 23 consecutive patients (M : F = 13:10) who underwent WSS, based on the automatic image pasting method for multiple exposure digital radiography. The Anterior-Posterior position(AP) and Posterior-Anterior position( PA) projection EDs were evaluated based on the PC based Monte Carlo simulation. We measured spine transverse process distance and angulation using DICOM measurement. For all patient, the average ED was 0.069 mSv for AP position and 0.0361 mSv for PA position. AP position calculated double exposure then PA position. For male patient, the average ED was 0.089 mSv(AP) and 0.050 mSv(PA). For female patient, the average ED was 0.0431 mSv(AP) and 0.026 mSv(PA). The transverse process of PA spine image measured 5% higher than AP but angulation of transverse process was no significant differences. In clinical practice, just by change the patient position was conformed to reduce the ED of patient. Therefor we need to redefine of protocol for digital radiography such as WSS. whole spine scanography, effective dose, patient exposure dose, exposure direction. protocol optimization.

The Effect of Body Mass Index on Entrance Surface Air Kerma in Abdominal X-ray Radiography Using Automatic Exposure Control (자동노출제어를 이용한 복부 일반 X선 검사에서 체질량지수가 입사표면공기커마에 미치는 영향)

  • Koo, No-Hyun;Yoon, Hee-Soo;Choi, Kwan-Woo;Lee, Jong-Eun;Kim, Jeong-Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.659-667
    • /
    • 2018
  • The purpose of this study was to determine the effect of body mass index (BMI) on entrance surface air kerma (ESAK) in abdominal X-ray radiography using automatic exposure control (AEC). This study included 321 patients who underwent abdominal X-ray using AEC, and we correlated ESAK with height, weight, BMI and compared mean ESAK according to BMI grades (Underweight, Normal, Overweight, Obese 1, Obese 2). As a result, Weight ($R^2=0.777$, p<.001) and BMI ($R^2=0.835$, p<.001) were positively associated with ESAK, but no significant association was found between height ($R^2=0.075$, p<.001) and ESAK. The mean ESAK with respect to BMI grades showed statistically significant difference and in the post-hoc analysis, the existence of 5 subgroups at the significance level of 0.05 indicated that there were differences in the ESAK in all BMI grades. Also, as the increment of ESAK between two neighboring BMI grades increases from Underweight to Obese 2, the exposure dose dramatically increased as the BMI increased. Thus, an excessive exposure dose due to increasing BMI when using AEC should be acknowledged and Efforts to reduce dose should be taken, such as: by fixing the exposure conditions.

Measurement of the Photon Fluence for the Evaluation of Photon Detection Efficiency of Photon Counting Sensor (광계수형 센서의 포톤계수효율 평가를 위한 포톤플루엔스 측정)

  • Park, Ji-Koon;Heo, Ye-Ji;Kim, Kyo-Tae;Noh, Si-Cheol;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • Recently, the various digital X-ray imaging devices using CCD and TFT LCD-based flat panel digital X-ray sensor are being used. In particular, a number of studies on photon counting sensor technique have been reported. In this study, the incident X-rays fluence on the photon counting sensor material was measured to estimate photon detection efficiency which is the quantitative performance evaluation factor of photon counting sensor. The result of measuring the photon fluence by using RQA-M2 Radiation beam quality of IEC 61223-1-2 recommendations, the incident photon fluence could be defined as about $4 photons/(0.01mm)^2{\cdot}{\mu}Gy$ within $10{\mu}m$ pin-hole area, and about $50photons/(0.03mm)^2{\cdot}{\mu}Gy$ within $30{\mu}m$ pin-hole area, and about $698photons/(0.1mm)^2{\cdot}{\mu}Gy$ within $100{\mu}m$ pin-hole area. Consequently, with the previously setup of the incident fluence, the measuring of actual photon counting efficiency by observing the output waveform of the photon counting sensor material was considered possible.

반도체 검출기의 절연 최적화를 위한 다층 절연막 평가

  • Park, Jeong-Eun;Myeong, Ju-Yeon;Kim, Dae-Guk;Kim, Jin-Seon;Sin, Jeong-Uk;Gang, Sang-Sik;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.372-372
    • /
    • 2014
  • 반도체 검출기는 입사되는 X선 에너지에 의하여 이온화되어 발생하는 전자 전공쌍을 수집함으로 방사선 정보를 확인하는 선량계로써 많은 연구와 활용이 이루어지고 있다. 하지만, X선 에너지에 의하여 반도체 검출기에서 발생하는 전기적 신호량이 높지 않기 때문에 누설 전류의 저감이 필수적이다. 누설 전류를 저감시키기 위한 방안으로 반도체 층과 전극 층의 Schottky Contact 구조의 설계, Insulating Layer의 사용, 높은 비저항의 반도체 물질 연구 등이 이루어지고 있다. 하지만, 기존에 누설 전류 저감을 위하여 Insulating Layer를 전극층과 반도체 층 사이에 형성하는 연구에 있어서 Insulating Layer와 반도체 층의 계면 사이에서 발생하는 Charge Trapping으로 인하여 생성되는 신호의 Reproducibility 저하, 동영상 적용의 제한 등의 문제점을 겪어왔다. 이에 본 논문에서는 누설 전류를 저감시킴과 동시에 Charge Trapping의 최소화를 이루기 위하여 Insulating Layer의 두께 최적화 연구를 수행하였다. 본 연구에서 사용한 Insulating Layer는 검출기 표면에 입사하는 X선 정보 손실을 최소화 시키는 동시에 누설 전류와 Charge Trapping을 최소화 시키는 방법으로써 CVD방법으로 검출기 표면에 균일하게 Insulating Layer를 코팅하였다. Insulating 물질은 Parylene을 사용하였으며, 그 중 온도, 습도 등 외부환경에 영향을 적게 받는 type C를 사용하였다. 증착에 사용한 장비의 진공도는 Torr로 설정하여 증착되는 Parylene의 두께가 약 $0.3{\mu}m$가 되게 하였으며, 실험에는 반도체 물질 PbO를 사용하였다. Parylene의 절연 특성은 Dark Current와 Sensitivity를 측정한 SNR을 이용하여 Parylene코팅이 되지 않은 동일 반도체 검출기와의 신호를 비교하였으며 또한 Parylene를 다층 제작한 검출기의 수집 신호량을 비교하였다. 제작한 검출기의 X선 조사 시의 수집 전하량 측정 결과, 100 kVp, 100mA, 0.03s의 X선 조건에서 $1V/{\mu}m$의 기준 시, Parylene를 코팅하지 않은 PbO 검출기의 Dark current는 0.0501 nA/cm2, Sensitivity는 0.6422 nC/mR-cm2, SNR은 12.184이었으며, Parylene단층의 두께인 $0.3{\mu}m$로 증착된 시편의 Dark current는 0.04097 nA/cm2, Sensitivity는 0.53732 nC/mR-cm2으로 Dark current가 감소되고 sensitivity도 감소하였지만 SNR은 13.1150으로 높아진 것을 확인할 수 있었다. Perylene이 $0.6{\mu}m$로 증착된 시편의 경우, Dark Current는 0.04064 nA/cm2, Sensitivity는 0.31473 nC/mR-cm2, SNR은 7.7443으로써 Insulating Layer가 없는 시편보다 SNR이 약 40% 낮아진 것을 확인할 수 있었다. Parylene이 $0.9{\mu}m$로 증착된 시편의 경우 Dark current는 0.0378 nA/cm2, Sensitivity 0.0461 nC/mR-cm2로 Insulating Layer가 없는 시편에 비해 SNR은 약 1/12배 감소한 1.2196이었고, Parylene이 $1.2{\mu}m$로 증착된 시편의 SNR은 1.1252로서 더 감소하였다. 따라서 Parylene을 다층 코팅한 검출기일수록 절연 효과의 영향이 커짐으로써 SNR 비교 시 수집되는 신호량이 줄어드는 것을 확인하였다. 반도체 검출기의 누설 전류를 저감시킴과 동시에 신호 수집율에 영향을 최소화시키기 위하여 Insulating Layer의 두께를 적절하게 설정하여 적용하면 Insulating Layer가 없는 검출기에 비해 누설전류를 최소한으로 줄일 수 있고 신호 검출효율이 감소하는 것을 방지할 수 있을 것이라 사료된다.

  • PDF